OCSL

Mini Type Crane Scale


User’s Guide
1 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide
TABLE OF CONTENTS

1. Introduction 3

2. Specifications 3
Features 3
Specifications 4
Capacities & Resolution 4
Schematic Diagram 5
Dimensions 5

3. Operation Guide 6
Power On 6
Power Off 6
Tare 6
Hold 7
Unit Switch 7
Zero 7
Settings 8

4. Troubleshooting 9

5. Calibration 10

2 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


1. Introduction

Note: Before using the scale, please read this guide and keep this for future
reference.

For good performance and precise measurement on daily operation, observe


the following safety guides and maintenance recommendations:

o Do NOT overload the scale. This may damage the load cell and will void
the warranty.
o Do NOT leave the load hanged on the scale for too long. This will
decrease scale’s accuracy and shorten the load cell’s life span.
o Inspect the shackle and hook before using. Check clips, pins and screws
properly fitted and installed.
o Check battery frequently. When scale drained its battery, charge the
battery with its dedicated charger or replace it with a new one
o Avoid rotating the scale, this may damage the load cell
o Do NOT use scale under thunder or rain.
o Do NOT attempt to repair the scale by yourself. Contact your local
dealer or to the Technical Support.

2. Specifications

FEATURES

This scale is a combination of sound and proven mechanical design, with


nowadays’ most advanced electronics to provide a superb feature sets. It is
versatile, reliable, accurate and easy to operate.

o Superb Quality. Strictly in accordance with OIML R76, Chinese


GB/T11883‐2000 certified quality system.
o Great Safety. Quality stainless steel load receptor and
Aluminum‐casting case to provide high safety level.
o Newest. 20mm LCD, visual distance can go to more than 10m
o Design. Demountable hook
o Leading Technology. SMT technology, quality integrated circuit and
dedicated weighing load cell and ensures long time stability.
o Smart Power Saving. 3*AA battery with low power consumption design
o Portable. Different color options. Easy to carry.

3 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


SPECIFICATIONS

Accuracy Class Chinese GB/T 11883‐2002 Class III


Equivalent to OIML R76
Tare Range 100% F.S.
Auto Zero ±50% F.S.
Manual Zero ±2% F.S.
Zero Tracking 0.5e/s
Reading Stable ≤10 seconds
Time
Auto‐sleep When stable and no activities within 3 sec.
Auto‐off When stable and no activities within 3 min.
Overload 100% F.S. + 9e
Max. Safety Load 120% F.S.
Ultimate Load 300% F.S.
Battery Life >150 hours
Temp. (Op.)
‐ 10℃ ~ + 40℃
Humidity (Op.)
≤90% at 20℃
Display 0.7 inch (17.78mm) numerical
Net Weight 620g

CAPACITIES & RESOLUTION

model max. cap. min. cap. resolution


(kg/lb) (kg/lb)
OCS‐003‐L 30/60 0.01/0.02 3,000
OCS‐005‐L 50/100 0.02/0.05 2,000
OCS‐006‐L 60/120 0.02/0.05 3,000
OCS‐01‐L 100/200 0.05/0.1 2,000
OCS‐012‐L 120/240 0.05/0.1 2,400
OCS‐015‐L 150/300 0.05/0.1 3,000
OCS‐02‐L 200/400 0.1/0.2 3,000
OCS‐03‐L 300/600 0.1/0.2 3,000

4 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


SCHEMATIC DIAGRAM

DIMENSIONS

5 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


3. Operation Guide

POWER ON

Press for 1 second to initialize boot up


and battery test.

o Screen will show detection message


while detecting its load and processing
auto‐zero.

POWER OFF

Press for 1 second to power off the scale.

o Display will show power‐off message.

TARE

Press to store the weight as tare.

o “TARE” will appear and weight reading


will turn to zero.
o If weight is greater than 100%F.S. or
lesser than 0, taring is not allowed.
o If weight reading is not stable or been held, taring is not
allowed.
o Taring will reduce the scale’s apparent overloading range.
For example, if a 10kg container is tared to a 50kg maximum
capacity scale, the new overload weight shall be at 40.18kg
(5000 – 1000 + 9 divisions).

6 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


HOLD

Press to lock the weight reading.

o “HOLD” will appear and reading in the


display will be frozen.
o Press again to unlock and scale
will read the actual load.

o “HOLD” will hide and weight


reading will resume.

UNIT SWITCH

Press for 1 second to switch measuring


unit between kg, lb and N.

o If scale is in tare or in hold, unit


switching is not allowed.

ZERO

Press for 1 second to zero the scale.

o “ZERO” will appear and weight reading


will turn to zero.
o If scale is in tare or load is not stable or
in hold, zeroing is not allowed.
o If the weight exceeds the Manual‐Zero
range, zeroing is not allowed.

7 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


SETTINGS

Hold and press and keys simultaneously


for 1 second to enter Settings Mode. SETUP should
appear in the display.

Press to enter Auto-off options and press


to select Auto-off option.

o Auto‐Off can be set to 0 (disabled), 5 (5min),


15 (15min), 30 (30min) and 60 (60min).

Press to enter Auto-Zero options and press


to select Auto-Zero option.
o Auto‐Zero can be set to 0 (disabled), 2
(2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.),
50 (50%F.S.).

Press to enter Manual-Zero options and


press to select Manual Zero option.
o Manual‐Zero can also be set to 0 (disabled),
2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20
(20%F.S.), 50 (50%F.S.)

Press to enter Backlight options and press

to select Backlight option.

o Backlight can be set to off (disabled), 5


(5sec), 15 (15sec), 30 (30sec), 60 (60sec) and on (never).
o When Backlight is set to 5, 15, 30, or 60, the scale will turn off the
backlight if the scale is stable and no activities within the set
parameters (enumerated above).
o When Backlight is set to off, the backlight is disabled and will never
turn on.

8 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


o When Backlight is set to on, the scale’s backlight will never turn off
even if it is stable and no activities on it.

o Press to exit the Settings mode

4. Troubleshooting

Symptoms Possible Causes Solutions


blank display when discharged battery replace battery
On/Off is pressed defective battery
defective ON/OFF key press ON/OFF key
for longer period
no action defective TARE or HOLD clean TARE or HOLD
taken after key key
TARE or
HOLD is
pressed
unstable readings scale in motion stabilize the load and
scale
scale is damped dry the scale
dust on PCB board clean PCB board
reading is not in zero unstable system power longer warm‐up time
without load load‐cell was hang the scale
stressed too much in storage
or too long
large error in weight scale is not zeroed keep the scale
reading before loading unloaded and reboot
re‐calibration needed re‐calibrate the scale
wrong unit switch to correct unit

9 | ANYLOAD OCSL Mini Type Crane Scale User’s Guide


5. Calibration

Options Display Operations Notes


Enter Hold and press [HOLD] and Enter Setup Mode
Calibration [TARE] simultaneously, keep (At this stage set the unit of
measurement you are going to
Mode pressing until SETUP
calibrate, hold & press
displays. the[HOLD/UNIT] to switch unit)
SETUP Press [ON/OFF], [HOLD] and Enter Calibration
[TARE] simultaneously, keep Mode
pressing until SCALE
displays.
SCALE Press [TARE].
Full Scale _XXXX Press [HOLD] to change For example, if you set
Full Scale and press [TARE] the unit at kg and setting
to save setting. the parameter here to
600 then the full scale
should be 600kg else if it
was set to lb then the full
scale shall be equivalent
to 600lb.
Resolution E X Press [HOLD] to change 1/2/5
Resolution and press
[TARE] to save setting.
Decimal Pt X Press [HOLD] to change 0: XXXXX
Point Decimal Point and press 1: XXXX.X
[TARE] to save setting. 2: XXX.XX
3: XX.XXX
Zero Press [TARE] to start zero Set the scale to no load
Calibration LoAd0 calibration. status and must be at stable
----- state.
Load1 Press [HOLD] to change 1st If using test weight
Calibration _XXXX Calibration Weight value. equivalent to full scale
Load the actual weight then (FULL), the calibration shall
----- press [TARE] to start span be finished at this stage.
calibration.
nd nd
Load2 Load the 2 test weight If 2 test weight is not
Calibration _FULL then press [TARE] to finish needed, you can skip this
the calibration. stage by pressing the
----- [ON/OFF] to finish and exit
the Calibration.
_End_