TMP - 1
TMP - 1
TMP - 1
Shop Number: ING ALEJANDRO NARVAEZ Address: Calle 12 # 6 - 38, Pasto, Nariño
Odometer
Model 1'/116i_N13 77686
Mileage
Technician notes
Daño electrico: terminal 15N_2 corto circuito a tierra. Se sospecha daño en DME. Inspeccion caja de fusibles OK.
Afectacion desempeño sensor MAF, VANOS INT EXH, BLOW OFF, TERMOSTATO.
Vehiculo solo diagnostico. NINGUNA ACCION CORRECTIVA EFECTUADA.
Scan report
System Status
DTC
System Codes Description Status
DME (Engine-Digital 1B5302 Supply, terminal 15N_2: Short circuit to ground Permanent
Motor Electronics)
DME (Engine-Digital 102A01 Mass air flow sensor, signal: Electrical fault Intermittent
Motor Electronics)
instagram.com/obd2.col Page 1
MaxiSys VEHICLE DIAGNOSTIC REPORT
DME (Engine-Digital Exhaust VANOS solenoid valve, activation: Short
130202 Intermittent
Motor Electronics) circuit to ground
DME (Engine-Digital 122002 Blow-off valve, activation: Short circuit to ground Intermittent
Motor Electronics)
DME (Engine-Digital 102A01 Mass air flow sensor, signal: Electrical fault Permanent
Motor Electronics)
DME (Engine-Digital 122002 Blow-off valve, activation: Short circuit to ground Permanent
Motor Electronics)
FEM (Front Electronic 804181 Side lights, front, right faulty Permanent
Module)
instagram.com/obd2.col Page 2