Cable Designation (P101)
Application Standard
- Design guide : NEK-606& IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%↓
Communication Cable
- Cold bend / impact : CSA 22.2 No.03 (-40℃/-35℃)
Instrumentation &
- Mud / Oil resistant : NEK-606 (Category a, b, c, d)
0.6/1kV RFOU
VFD Cable
- Insulated cores shall be cabled
Cabling - Flame retardant & non-hygroscopic fillers may be used
- Suitable tape(s) may be applied on the cabled core
- A Filler may be applied to obtain a circular Cable
Inner covering F - Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O)
O
Armor - Option : Bronze wire braid (B) /galvanized steel wire braid (C)
(B,C)
- A suitable separator tape(s) may be applied under/over the armor
HCF Cable
Offshore Cable 23
Halogen free & Mud resistant Offshore cable
24 Offshore Cable
LV Power & Lighting Cable • ● • • • •
HV Power Cable
wires dia. covering covering (Max.) (Min.)
No. mm2 EA mm mm mm mm mm mm mm ±mm Ω/km ㏁-km V/5min. kg/km
1.5 7 1.7 1.0 1.0 9.8 0.3 1.2 13.7 0.8 12.2 1,320 3,500 320
2.5 7 2.2 1.0 1.0 10.6 0.3 1.3 14.7 0.9 7.56 1,110 3,500 380
4 7 2.7 1.0 1.0 11.7 0.3 1.3 15.8 0.9 4.70 940 3,500 460
6 7 3.3 1.0 1.0 13.0 0.3 1.4 17.3 1.0 3.110 800 3,500 570
10 7 4.2 1.0 1.0 14.9 0.3 1.4 19.2 1.1 1.840 650 3,500 730
Communication Cable
Instrumentation &
300 61 23.1 2.4 1.6 62.6 0.4 3.4 71.3 3.2 0.0607 310 3,500 12,380
3C+E 1.5 7 1.7 1.0 1.0 10.7 0.3 1.3 14.8 0.9 12.2 1,320 3,500 380
3C+E 2.5 7 2.2 1.0 1.0 11.7 0.3 1.3 15.8 0.9 7.56 1,110 3,500 450
3C+E 4 7 2.7 1.0 1.0 12.9 0.3 1.4 17.2 1.0 4.70 940 3,500 550
3C+E 6 7 3.3 1.0 1.0 14.3 0.3 1.4 18.6 1.0 3.110 800 3,500 680
3C+E 10 7 4.2 1.0 1.0 16.5 0.3 1.5 21.0 1.1 1.840 650 3,500 900
3C+E 16 7 5.3 1.0 1.0 18.9 0.3 1.6 23.6 1.2 1.160 540 3,500 1,210
3C 25 7 6.6 1.2 1.0 22.4 0.3 1.7 27.3 1.4 0.734 520 3,500 1,640
VFD Cable
3C 150 37 16.2 1.8 1.4 47.9 0.4 2.8 55.4 2.5 0.126 330 3,500 7,520
Earth 95 19 12.9 1.6 0.195
3C 185 37 18.0 2.0 1.6 53.7 0.4 3.0 61.6 2.8 0.100 330 3,500 9,150
Earth 95 19 12.9 1.6 0.195
3C 240 61 20.6 2.2 1.6 60.4 0.4 3.3 68.9 3.1 0.0762 320 3,500 11,610
Earth 120 37 14.5 1.6 0.154
1.5 7 1.7 1.0 1.0 10.7 0.3 1.3 14.8 0.9 12.2 1,320 3,500 380
2.5 7 2.2 1.0 1.0 11.7 0.3 1.3 15.8 0.9 7.56 1,110 3,500 450
4 7 2.7 1.0 1.0 12.9 0.3 1.4 17.2 1.0 4.70 940 3,500 550
HCF Cable
6 7 3.3 1.0 1.0 14.3 0.3 1.4 18.6 1.0 3.110 800 3,500 680
10 7 4.2 1.0 1.0 16.5 0.3 1.5 21.0 1.1 1.840 650 3,500 900
16 7 5.3 1.0 1.0 18.9 0.3 1.6 23.6 1.2 1.160 540 3,500 1,210
25 7 6.6 1.2 1.0 23.0 0.3 1.8 28.1 1.4 0.734 520 3,500 1,770
35 7 7.9 1.2 1.0 25.7 0.3 1.9 31.0 1.5 0.529 450 3,500 2,250
4
50 19 9.1 1.4 1.2 30.8 0.4 2.1 36.9 1.8 0.391 440 3,500 3,150
70 19 11.0 1.4 1.2 34.9 0.4 2.3 41.4 2.0 0.270 380 3,500 4,160
Technical Information
95 19 12.9 1.6 1.4 40.9 0.4 2.5 47.8 2.2 0.195 370 3,500 5,580
120 37 14.5 1.6 1.4 44.5 0.4 2.6 51.6 2.4 0.154 330 3,500 6,700
150 37 16.2 1.8 1.6 49.7 0.4 2.9 57.4 2.6 0.126 330 3,500 8,200
185 37 18.0 2.0 1.6 55.7 0.4 3.1 63.8 2.9 0.100 330 3,500 10,140
240 61 20.6 2.2 1.6 62.9 0.4 3.4 71.6 3.2 0.0762 320 3,500 12,960
300 61 23.1 2.4 1.8 70.1 0.4 3.7 79.4 3.5 0.0607 310 3,500 16,000
Offshore Cable 25
Halogen free & Mud resistant Offshore cable
26 Offshore Cable
LV Power & Lighting Cable • ● • • • •
HV Power Cable
wires dia. covering covering (Max.) (Min.)
No. mm2 EA mm mm mm mm mm mm mm ±mm Ω/km ㏁-km V/5min. kg/km
2 1.0 7 1.4 1.0 1.0 8.6 0.3 1.2 12.5 0.8 18.2 1,490 3,500 250
5 1.0 7 1.4 1.0 1.0 10.9 0.3 1.3 15.0 0.9 18.2 1,490 3,500 360
7 1.0 7 1.4 1.0 1.0 11.9 0.3 1.3 16.0 0.9 18.2 1,490 3,500 430
8 1.0 7 1.4 1.0 1.0 12.9 0.3 1.4 17.2 1.0 18.2 1,490 3,500 480
9 1.0 7 1.4 1.0 1.0 13.9 0.3 1.4 18.2 1.0 18.2 1,490 3,500 520
Communication Cable
2 1.5 7 1.7 1.0 1.0 9.2 0.3 1.2 13.1 0.8 12.2 1,320 3,500 290
Instrumentation &
5 1.5 7 1.7 1.0 1.0 11.7 0.3 1.3 15.8 0.9 12.2 1,320 3,500 430
7 1.5 7 1.7 1.0 1.0 12.8 0.3 1.4 17.1 1.0 12.2 1,320 3,500 500
8 1.5 7 1.7 1.0 1.0 13.9 0.3 1.4 18.2 1.0 12.2 1,320 3,500 550
9 1.5 7 1.7 1.0 1.0 15.0 0.3 1.5 19.5 1.1 12.2 1,320 3,500 610
10 1.5 7 1.7 1.0 1.0 16.4 0.3 1.5 20.9 1.1 12.2 1,320 3,500 670
12 1.5 7 1.7 1.0 1.0 17.0 0.3 1.5 21.5 1.2 12.2 1,320 3,500 730
14 1.5 7 1.7 1.0 1.0 17.9 0.3 1.6 22.6 1.2 12.2 1,320 3,500 820
16 1.5 7 1.7 1.0 1.0 18.9 0.3 1.6 23.6 1.2 12.2 1,320 3,500 900
VFD Cable
12 2.5 7 2.2 1.0 1.0 18.6 0.3 1.6 23.3 1.2 7.56 1,110 3,500 910
14 2.5 7 2.2 1.0 1.0 19.7 0.3 1.6 24.4 1.3 7.56 1,110 3,500 1,010
16 2.5 7 2.2 1.0 1.0 20.8 0.3 1.7 25.7 1.3 7.56 1,110 3,500 1,120
19 2.5 7 2.2 1.0 1.0 22.0 0.3 1.7 26.9 1.4 7.56 1,110 3,500 1,260
24 2.5 7 2.2 1.0 1.0 26.0 0.3 1.9 31.3 1.6 7.56 1,110 3,500 1,570
27 2.5 7 2.2 1.0 1.0 26.6 0.3 1.9 31.9 1.6 7.56 1,110 3,500 1,700
30 2.5 7 2.2 1.0 1.2 28.5 0.3 2.0 34.0 1.7 7.56 1,110 3,500 1,940
37 2.5 7 2.2 1.0 1.2 30.8 0.4 2.1 36.9 1.8 7.56 1,110 3,500 2,370
44 2.5 7 2.2 1.0 1.2 34.8 0.4 2.3 41.3 2.0 7.56 1,110 3,500 2,790
HCF Cable
2 4 7 2.7 1.0 1.0 11.0 0.3 1.3 15.1 0.9 4.70 940 3,500 400
5 4 7 2.7 1.0 1.0 14.2 0.3 1.4 18.5 1.0 4.70 940 3,500 640
7 4 7 2.7 1.0 1.0 15.5 0.3 1.5 20.0 1.1 4.70 940 3,500 750
8 4 7 2.7 1.0 1.0 16.9 0.3 1.5 21.4 1.2 4.70 940 3,500 830
9 4 7 2.7 1.0 1.0 18.3 0.3 1.6 23.0 1.2 4.70 940 3,500 930
10 4 7 2.7 1.0 1.0 20.0 0.3 1.7 24.9 1.3 4.70 940 3,500 1,040
12 4 7 2.7 1.0 1.0 20.7 0.3 1.7 25.6 1.3 4.70 940 3,500 1,160
Technical Information
14 4 7 2.7 1.0 1.0 21.9 0.3 1.7 26.8 1.4 4.70 940 3,500 1,290
16 4 7 2.7 1.0 1.0 23.2 0.3 1.8 28.3 1.4 4.70 940 3,500 1,440
19 4 7 2.7 1.0 1.0 24.5 0.3 1.8 29.6 1.5 4.70 940 3,500 1,630
24 4 7 2.7 1.0 1.2 29.8 0.3 2.0 35.3 1.7 4.70 940 3,500 2,130
27 4 7 2.7 1.0 1.2 30.5 0.4 2.1 36.6 1.8 4.70 940 3,500 2,410
30 4 7 2.7 1.0 1.2 31.7 0.4 2.1 37.8 1.8 4.70 940 3,500 2,600
37 4 7 2.7 1.0 1.2 34.3 0.4 2.2 40.6 1.9 4.70 940 3,500 3,070
44 4 7 2.7 1.0 1.4 39.2 0.4 2.4 45.9 2.1 4.70 940 3,500 3,680
Offshore Cable 27
Halogen free & Mud resistant Offshore cable
28 Offshore Cable
LV Power & Lighting Cable • ● • • • •
HV Power Cable
dia.
No. mm2 mm mm mm mm mm mm mm ±mm kg/km
1.5 1.8 1.0 1.0 9.8 0.3 1.2 13.7 0.8 320
2.5 2.4 1.0 1.0 10.8 0.3 1.3 14.9 0.9 390
4 3.0 1.0 1.0 11.9 0.3 1.3 16.0 0.9 470
6 3.9 1.0 1.0 13.2 0.3 1.4 17.5 1.0 580
Communication Cable
150 19.0 1.8 1.4 48.0 0.4 2.8 55.5 2.5 6,890
Instrumentation &
185 21.0 2.0 1.6 52.7 0.4 2.9 60.4 2.7 8,330
240 24.0 2.2 1.6 59.4 0.4 3.2 67.7 3.0 10,640
300 27.0 2.4 1.8 66.0 0.4 3.5 74.9 3.3 13,320
3C+E 1.5 1.8 1.0 1.0 10.7 0.3 1.3 14.8 0.9 370
3C+E 2.5 2.4 1.0 1.0 11.9 0.3 1.3 16.0 0.9 450
3C+E 4 3.0 1.0 1.0 13.1 0.3 1.4 17.4 1.0 560
VFD Cable
3C 70 13.1 1.4 1.2 36.9 0.4 2.3 43.4 2.0 4,080
Earth 35 9.2 1.2
3C 95 15.1 1.6 1.4 42.4 0.4 2.6 49.5 2.3 5,360
Earth 50 11.0 1.4
3C 120 17.0 1.6 1.4 46.8 0.4 2.7 54.1 2.5 6,590
Earth 70 13.1 1.4
3C 150 19.0 1.8 1.6 52.6 0.4 2.9 60.3 2.7 8,280
HCF Cable
Offshore Cable 29
Halogen free & Mud resistant Offshore cable
30 Offshore Cable
LV Power & Lighting Cable • ● • • • •
HV Power Cable
dia.
No. mm2 mm mm mm mm mm mm mm ±mm kg/km
5 1.0 1.5 1.0 1.0 10.9 0.3 1.3 15.0 0.9 370
7 1.0 1.5 1.0 1.0 11.9 0.3 1.3 16.0 0.9 430
9 1.0 1.5 1.0 1.0 13.9 0.3 1.4 18.2 1.0 540
12 1.0 1.5 1.0 1.0 15.7 0.3 1.5 20.2 1.1 660
Communication Cable
Instrumentation &
7 1.5 1.8 1.0 1.0 12.8 0.3 1.4 17.1 1.0 500
9 1.5 1.8 1.0 1.0 15.0 0.3 1.5 19.5 1.1 630
12 1.5 1.8 1.0 1.0 17.0 0.3 1.5 21.5 1.2 770
14 1.5 1.8 1.0 1.0 17.9 0.3 1.6 22.6 1.2 850
16 1.5 1.8 1.0 1.0 18.9 0.3 1.6 23.6 1.2 930
19 1.5 1.8 1.0 1.0 20.0 0.3 1.7 24.9 1.3 1,050
24 1.5 1.8 1.0 1.0 23.6 0.3 1.8 28.7 1.4 1,330
VFD Cable
16 2.5 2.4 1.0 1.0 21.3 0.3 1.7 26.2 1.3 1,200
19 2.5 2.4 1.0 1.0 22.5 0.3 1.8 27.6 1.4 1,360
24 2.5 2.4 1.0 1.0 26.6 0.3 1.9 31.9 1.6 1,730
27 2.5 2.4 1.0 1.2 28.0 0.3 2.0 33.5 1.6 1,960
30 2.5 2.4 1.0 1.2 29.1 0.3 2.0 34.6 1.7 2,110
37 2.5 2.4 1.0 1.2 31.5 0.4 2.1 37.6 1.8 2,570
44 2.5 2.4 1.0 1.2 35.6 0.4 2.3 42.1 2.0 3,100
5 4 3.0 1.0 1.0 14.4 0.3 1.4 18.7 1.0 640