Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Selkirk SPR001-US-E May 2021 Web

Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

CHIMNEY

CATALOG

FUEL TYPE:

Gas | Oil | Wood | Coal

US ONLY
TABLE OF CONTENTS

Typical Installation..................................................................................................................... 3

Technical Data Sheet................................................................................................................. 4

Stainless Steel Chimney lengths................................................................................................... 5

Adjustable Chimney Lengths....................................................................................................... 6

Stainless Steel Elbows............................................................................................................. 7-8

Tee Components....................................................................................................................... 9

Supports........................................................................................................................... 10-11

Shields................................................................................................................................... 12

Flashings and Storm Collars................................................................................................ 13-14

Premium Rain Caps................................................................................................................. 15

Parts and Accessories......................................................................................................... 16-17

Fireplace Parts........................................................................................................................ 18

Support Kits............................................................................................................................ 19

2
Typical Installation
CEILING SUPPORT INSTALLATIONS

One Story Two Story Elbow Installation

NOTE: An installation in Canada will require a Supplemental Radiation


Shield where the chimney system is enclosed in living or attic spaces

CEILING SUPPORT INSTALLATIONS WALL SUPPORT INSTALLATIONS

With Square Ceiling/Cathedral One Story Through a Soffit


Support

USE DCC STOVE PIPE FOR OPTIMUM SYSTEM PERFORMANCE


Note: Technical data, photographs, drawings and installations may vary and are for reference only. Actual installations must be conducted according to the data and drawings shown in the installation instructions.

3
TECHNICAL DATA SHEET
FOR THE CHIMNEY PROFESSIONAL WHO DEMANDS ENHANCED FEATURES
THE BEST... Premium Grade Stainless Steel construction of both the inner liner and
SuperPro incorporates the latest technology in factory-built chimney outer casing make SuperPro chimney extremely corrosion resistant.
design; providing superior performance, durability, and safety. SuperPro Embossed couplers do not allow moisture to penetrate the chimney’s
is designed to accompany today’s appliances, which are engineered to outer wall. Sections simply ‘twist-lock’ together and may be secured with
produce low emissions and high heat. This makes SuperPro the choice of optional Locking Bands. The SuperPro product line features Deluxe
professionals who are looking for a better-quality, factory built chimney Chimney Support Components that will enhance any installation.
system.
SUPPORTS/FRAMING
CERTIFICATION & APPLICATIONS All SuperPro Supports are designed to carry four times the combined
SuperPro is Safety Tested and Listed to applicable UL/ULC Standards. weight of each system at maximum allowable height.
These include:
Support and Framing Dimensions Table
Canada: ULC S-604
Support Ceiling Support Wall Support Cath. Ceiling Support Roof Support
Safety Standard for chimneys serving liquid/gas fuel appliances
50' 38' 38' 50'
This chimney system may be used on appliances that burn Oil or Gas.
Diameter Framing Dimensions
SuperPro Model SPR may also be used with specific listed factory-built
fireplaces listed to UL 127 or ULC-S610. 5" Dia. 11-3/8" x 11-3/8" 14-3/8" x 14-3/8" 11" x 11" 11" x 11"
USA: UL 103-HT 6" Dia. 12-3/8" x 12-3/8" 14-3/8" x 14-3/8" 12" x 12" 12" x 12"
Safety Standards for chimneys serving solid fuel and liquid fuel appliances. 7" Dia. 13-3/8" x 13-3/8" 14-3/8" x 14-3/8" 13" x 13" 13" x 13"
This chimney system has been designed for use on wood stoves, fireplaces 8" Dia. 14-3/8" x 14-3/8" 14-3/8" x 14-3/8" 14" x 14" 14" x 14"
and residential furnaces in the U. S. market.
Allowable Flue Gas Temperatures are:
CONSTRUCTION
Maximum Continuous 1000° F / 540° C Inner Liner (Flue): Premium Grade Stainless Steel
0.016" thickness
Brief Forced Firing 1400° F / 760° C (60 min.)
Creosote Burn Out 2100° F / 1150° C (3 x 10 min.) Outer Casing: Premium Grade Stainless Steel
0.016" thickness
SMART CHOICE LIFETIME WARRANTY Note: All SuperPro Twist-Lock Couplers are embossed (not lanced) and
The SuperPro Smart Choice Lifetime Warranty applies to all Chimney seams are weather-proofed to prevent moisture from entering the chimney.
components (not just insulated lengths) making SuperPro chimney the smart Insulation: The 1" space between the inner/outer walls is Solid Packed
choice, every time. (See written Warranty for details). with Mineral Wool Fibre insulation to provide superior insulating qualities,
in a “slim-line” design. Solid Pack design performs favorably to Blanket
type and Air-Cooled chimney designs.

EMBOSSED COUPLER PREMIUM GRADE STAINLESS


Prevents moisture STEEL INNER LINER
penetration High grade material heats up
quickly to enhance draft

PREMIUM FIBRE
"SOLID PACK INSULATION" INSULATION
Augured for better insulating value 100% Mineral Wool
(than blanket insulation) to keep outside (No Chlorides)
temperatures low - for safety and inside
temperatures high - for performance

TWIST-LOCK CONNECTION
PREMIUM GRADE STAINLESS Easy Assembly
STEEL OUTER CASING
Premium material prevents
corrosion

The Best Warranty in the Industry


Selkirk features an advanced engineering design and premium quality material which allow us to offer a Lifetime Warranty
on all component parts. See written warranty for details.
Stainless Steel Chimney Lengths
The chimney must extend at least three feet above the highest point where HEIGHT REQUIREMENTS
it passes through the roof surface and at least two feet higher than any
part of the building within a horizontal distance of ten feet.

• Slim, advanced design allows for installation between 16" centers CHIMNEY SECTIONS
• A 2" clearance to combustible materials must be maintained at all
times, except in areas protected by factory supplied support certified for
reduced clearance
• Secure twist-lock design couples chimney sections together with just a
1/8th turn
• Sectional overlap of 1-1/8"
• Chimneys are sized according to the inner diameter and are
available in 5", 6", 7" and 8"

Size A B C Product Code Pack


5" x 36" 36" 5" 7" SPR5L36 1 C
5" x 24" 24" 5" 7" SPR5L24 1 B
5" x 18" 18" 5" 7" SPR5L18 1
5" x 12" 12" 5" 7" SPR5L12 1
5" x 6" 6" 5" 7" SPR5L6 1

6" x 48" 48" 6" 8" SPR6L48 1


6" x 36" 36" 6" 8" SPR6L36 1
A
6" x 24" 24" 6" 8" SPR6L24 1
6" x 18" 18" 6" 8" SPR6L18 1
6" x 12" 12" 6" 8" SPR6L12 1
6" x 6" 6" 6" 8" SPR6L6 1

7" x 48" 48" 7" 9" SPR7L48 1


7" x 36" 36" 7" 9" SPR7L36 1
7" x 24" 24" 7" 9" SPR7L24 1
7" x 18" 18" 7" 9" SPR7L18 1
7" x 12" 12" 7" 9" SPR7L12 1
7" x 6" 6" 7" 9" SPR7L6 1

8" x 48" 48" 8" 10" SPR8L48 1


8" x 36" 36" 8" 10" SPR8L36 1
8" x 24" 24" 8" 10" SPR8L24 1
8" x 18" 18" 8" 10" SPR8L18 1
8" x 12" 12" 8" 10" SPR8L12 1
8" x 6" 6" 8" 10" SPR8L6 1

5
Adjustable Chimney Length

C • SuperPro Adjustable Length


B
• Used to adjust the system to an exact overall height
• Used between elbows for a required offset distance
• All stainless construction and includes hardware
• Length adjusts from 2" to 9-1/2"
A

Size A B C Product Code Pack


5" x 12" 12" 5" 7.31" SPR5AL12 1
6" x 12" 12" 6" 8.31" SPR6AL12 1
7" x 12" 12" 7" 9.31" SPR7AL12 1
8" x 12" 12" 8" 10.31" SPR8AL12 1

LOCKING BANDS • Two flanges engage the curls in each end of the adjoining sections
holding them securely together
• Supplied with Captured Nut & Bolt
• Locking Bands must be used:
- on all sections that make up an offset
- on tee branch to attach a chimney length
- on any length suspended below the Cathedral or Roof Support
• While Locking Bands are not required on other chimney lengths,
their use is recommended for added safety and stability. It also
provides a more attractive appearance

Size A B Product Code Pack


5" 7" 7/16" SPR5SLB 5
6" 8" 7/16" SPR6SLB 5
7" 9" 7/16" SPR7SLB 5
8" 10" 7/16" SPR8SLB 5

6
Stainless Steel Elbows

15° OFFSET CHART This chart has three columns for elbow angle
Offset Height Lengths Required required to achieve your desired offset.
5" 6" 7" 8" 5" 6" 7" 8" 6" 12" 18" 24" 36" The first column (”Offset”) is the horizontal
1-1/2 1-1/8 1-1/8 1-1/4 9 10 10-1/4 10-3/8 – – – – – measurement, at the chimney center line, of the offset
2-1/8 2-3/8 2-3/8 2-1/2 13-1/2 14-1/4 15 15-5/8 1 – – – – needed to get around an obstacle.
4 4 4 4 19-1/8 20-1/2 20-3/4 21 – 1 – – – The second column (”Height”) is the height of the
5-1/2 5-1/2 5-1/2 5-1/2 25 26-1/4 26-1/2 26-3/4 – – 1 – – assembled offset elbow to the top of the return elbow.
7-1/2 7 7 7 30-1/2 32 32-1/4 32-1/2 – – – 1 – Column 3 shows the appropriate lengths required.
10-1/8 10-1/8 10-1/4 10-1/4 42 43-5/8 44 44-1/8 – – – – 1
11-1/4 11-3/8 11-1/2 11-1/2 48-1/4 48-3/8 48-5/8 48-7/8 1 – – – 1 1. Determine the distance of the offset required
12-3/4 13 13 13 54 54-1/8 54-3/8 54-5/8 – 1 – – 1 2. On the chart, find the predetermined distance required for the elbow kit under
14-3/8 14-1/2 14-1/2 14-5/8 59-3/4 60 60-1/8 60-3/8 – – 1 – 1 the corresponding chimney diameter
16 16-1/8 16-1/8 16-1/8 65-1/2 65-3/4 66 66-1/4 – – – 1 1 3. After finding the offset, follow across the chart to find the specified height and
19 19 19 19 76-1/4 76-1/4 76-1/2 76-3/4 – 1 – 1 1 appropriate chimney lengths required under their corresponding diameters

All measurements in inches. Offset tolerances ± one inch.

30° OFFSET CHART


Offset Height Lengths Required
5" 6" 7" 8" 5" 6" 7" 8" 6" 12" 18" 24" 36"
3 2-3/4 3-1/8 3-1/2 10 11-5/8 13 14-1/2 – – – – –
5-1/4 5-1/4 5-5/8 6 14 15-7/8 17-1/4 18-3/8 1 – – – –
9 8-1/4 8-5/8 9 19-1/4 21 22-3/8 24 – 1 – – –
11-1/4 11-1/4 11-5/8 12 24-1/2 26-1/4 27-5/8 29-1/8 – – 1 – –
14-1/4 14-1/4 14-5/8 15 29-3/4 31-3/8 32-7/8 32-3/8 – – – 1 –
20 20-1/4 20-5/8 21 39-3/4 41-7/8 43-1/4 44-3/4 – – – – 1
21-7/8 22-5/8 23 23-1/2 44-1/2 46 47-1/2 49 1 – – – 1
23-7/8 25-5/8 26 26-1/2 50-1/8 51-1/4 52-5/8 54-1/8 – 1 – – 1
27-1/8 28-5/8 29 29-1/2 55-1/8 56-3/8 57-3/8 59-3/8 – – 1 – 1
30-3/8 31-5/8 32 32 60-5/8 61-5/8 63 64-1/2 – – – 1 1
37 37-1/8 37-1/2 38 69-3/8 71 72-1/2 74 – 1 – 1 1

INSULATED 15° AND 30° ELBOW KITS


ELBOW KITS INCLUDE:
• The Insulated Elbow is used when an offset
- 2 ELBOWS is required
- 4 LOCKING BANDS
• Locking Bands must be used on all elbows
- 1 ELBOW SUPPORT
- HARDWARE PACK • A maximum of 6 feet is allowable between
elbows
• Elbow is fully insulated and can be used at
the same 2"clearance as chimney lengths
• Elbow support must be used with all offset
installations
• Elbows do not have locking ridges and can
be rotated to attain optimum positioning,
and allow chimney to return to correct
vertical alignment, prior to installing
Locking Bands

7
Stainless Steel Elbows continued
15˚ ELBOW Size A B C Product Code Pack
15° - 5" 3-3/8" 2-7/16" 1-15/16" SPR5EL15K 1
15° - 6" 3-3/8" 2-1/2" 2" SPR6EL15K 1
15° - 7" 3-3/8" 2-9/16” 2-1/16" SPR7EL15K 1
15° - 8" 3-3/8" 2-5/8" 2-1/8" SPR8EL15K 1

Size A B C Product Code Pack


30˚ ELBOW
30° - 5" 2-3/4" 2-9/16" 2-9/16" SPR5EL30K 1
30° - 6" 3-1/4" 3-1/16" 2-9/16" SPR6EL30K 1
30° - 7" 3-3/4" 3-7/16" 2-15/16" SPR7EL30K 1
30° - 8" 4-1/4" 3-7/8" 3-3/8" SPR8EL30K 1

8
Tee Components
• The insulated chimney tee is used for through-the-wall installation INSULATED TEE WITH PLUG
using a wall support
• A chimney length is attached to the tee branch using a Locking
Band to pass safely through a wall
• Supplied with uninsulated Tee Plug

Size A B C D E Product Code Pack


5" 7" 5" 10-1/2" 5" 5" SPR5ITP 1
6" 8" 6" 11-1/2" 5-5/8" 5-3/4" SPR6ITP 1
7" 9" 7" 12-1/4" 6-1/4" 6-3/16" SPR7ITP 1
8" 10" 8" 13-3-8" 6-5/8" 6-1/2" SPR8ITP 1

• Used under the AWS Wall Support INSULATED TEE PLUG


• Removable to provide easy access for chimney inspection and
maintenance
• Insulated to help maintain flue gas temperature

Size A B C Product Code Pack


5" 7" 5" 2-7/8" J51TPI 1
6" 8" 6" 2-7/8" J61TPI 1
7" 9" 7" 2-7/8" J71TPI 1
8" 10" 8" 2-7/8" J81TPI 1

• Replacement Non-Twist Lock Insulated Tee Cap used with the NON-TWIST LOCK INSULATED TEE CAP
WS Wall Support
• Removable to provide easy access for chimney inspection and
maintenance
• Insulated to help maintain flue gas temperature B
C
Size A B C Product Code Pack
A
5" 6-1/8" 4-31/32" 1-9/32" SPR5NTITC 1
6" 7-1/8" 5-31/32" 1-9/32" SPR6NTITC 1
7" 8-1/8" 6-31/32" 1-9/32" SPR7NTITC 1
8" 9-1/8" 7-31/32" 1-9/32" SPR8NTITC 1

9
Supports
ADJUSTABLE WALL SUPPORT • Used to support the chimney on a through-the-wall installation
• Will support up to 38 feet of chimney
• Includes wall support top plate with female coupler attached, male
adapter ring, side brackets and hardware

Size A B C Product Code Pack


5" 10" 17-1/8" 16" JSC5AWS 1
6" 11" 17-1/8" 16" JSC6AWS 1
7" 12" 17-1/8" 16" JSC7AWS 1
8" 13" 17-1/8" 16" JSC8AWS 1

ADJUSTABLE INTERMEDIATE WALL • Used as supplementary support when chimney system height
SUPPORT exceeds maximum height allowed by Wall Support
• Supports an additional 38 feet of chimney
• Includes Top Plate, Support Band, Side Brackets and Hardware

Size A B C Product Code Pack


6" 17-1/8" 11" 16" JSC6AIWS 1
7" 17-1/8" 12" 16" JSC7AIWS 1
8" 17-1/8" 13" 16" JSC8AIWS 1

ADJUSTABLE WALL SUPPORT WITH • Used to support chimney on a through-the-wall installation


INSULATED TEE CAP • Will support between 30 feet and 74 feet of chimney height based on
size & orientation from wall
• Adjustment of 2" to 6" from a vertical wall
• Includes wall support top plate, side brackets, hardware, non-twist
lock insulated tee cap, and L-bracket to contain tee cap

Size A B C Product Code Pack


5" 10-5/8" 18-7/8" 12" JSC5WS 1
6" 10-5/8" 18-7/8” 12" JSC6WS 1
7" 11-5/8" 20-1/2” 13" JSC7WS 1
8" 12-5/8" 21-7/8” 14" JSC8WS 1

UNIVERSAL EXTENDED WALL SUPPORT • Designed to support a vertical wall installation above the
insulated tee
• Will support up to 28 feet of chimney
• Adjusts up to 12" from a vertical wall & will allow to pass by a 12"
overhang

Size A B C Product Code Pack


6" to 8" 22" 4" 8" to 10" 0800900 1

10
Supports continued
• Supports up to 50 feet of chimney DECORATOR CEILING SUPPORT-SPUN
• Matte black support gives a finished appearance

Size A B C Product Code Pack


6" 17-7/8" 12-3/8" 8-1/4" JSC6DCSS 1
7" 17-7/8" 13-3/8" 9-1/4" JSC7DCSS 1
8" 19-5/8" 14-3/8" 10-1/4" JSC8DCSS 1

• For use in ceiling support installations DECORATOR CEILING SUPPORT


• Supports up to 50 feet of chimney
• Matte black finish gives a premium finished appearance

Size A B C Product Code Pack


5" 17-7/8" 11-3/8" 7-1/4" SPR5CSB 1
6” 17-7/8" 12-3/8" 8-1/4" SPR6CSB 1
7” 17-7/8" 13-3/8" 9-1/4" SPR7CSB 1
8” 19-5/8" 14-3/8" 10-1/4" SPR8CSB 1

• Used in pitched ceiling support installations CATHEDRAL CEILING SUPPORT BOX


• Supports up to 38 feet of chimney
• Matte black finish
• Includes Support Box, Support Band and Ceiling Trim pieces

Size A B C Product Code Pack


5" 7-3/16" 11" 17" SPR5CCSB 1
6" 8-3/16" 12" 17" SPR6CCSB 1
7" 9-3/16" 13" 17" SPR7CCSB 1
8" 10-3/16" 14" 17" SPR8CCSB 1 Add JUSI (pg. 17) to the Cathedral Ceiling
Support for increased performance and safety.

• The Roof Support may be used on a floor, ceiling or roof and adjusts ROOF SUPPORT
to any roof pitch
• It may be used above an offset to support the offset or as a
supplementary support when the chimney height exceeds that of the
primary support
• The Roof Support will support a total height of 50 feet of chimney

Size A B Product Code Pack


5" 7" 5" JSC5RS 1
6" 8" 5" JSC6RS 1
7" 9" 5" JSC7RS 1
8" 10" 5" JSC8RS 1

11
Shields
ATTIC INSULATION SHIELD • The AIS must be installed where the chimney enters the attic space in
any installation
• When fully extended the AIS provides joist shielding
• Designed to keep insulation away from the chimney, and to maintain
the mandatory 2" clearance to combustibles

Size A B C D E Product Code Pack


5" 11" 7" 13" 11-13/16" 8-1/2" JSC5AIS 1
6" 12" 8" 14" 11-13/16" 8-1/2" JSC6AIS 1
7" 13" 9" 15" 11-13/16" 8-1/2" JSC7AIS 1
8" 14" 10" 16" 11-13/16" 8-1/2" JSC8AIS 1

Add JUSI (pg. 17) to the Attic Insulation Shield


for increased performance and safety.

FIRESTOP RADIATION SHIELD • Also known as a Firestop Joist Shield


• Required where the chimney passes from one lower living space to
another living space
• Maintains the mandatory 2" clearance to combustibles

Size A B C Product Code Pack


5" 9" 19" 13” JSC5FRS 1
6" 10" 19" 14" JSC6FRS 1
7" 11" 19" 15" JSC7FRS 1
8" 12" 19" 16" JSC8FRS 1

RAFTER RADIATION SHIELD The RRS must be installed where the chimney is enclosed immediately
below the roof line

Size A B Product Code Pack


5" 9" 12" JSC5RRS 1
6" 10" 12" JSC6RRS 1
7" 11" 12" JSC7RRS 1
8" 12" 12" JSC8RRS 1

WALL THIMBLE
• Used in a wall support installation
• Radiation shield is included with spacers which maintain the
mandatory 2" clearance to combustibles
• Attractive matte black finishing trim is included
• Extends to fit 7" wall thickness

Size A B C Product Code Pack


5" 7-1/8" 16" 16-1/8" SPR5WTB 1
6" 8-1/8" 16" 16-1/8" SPR6WTB 1

Add JUSI (pg. 17) to the Wall Thimble for 7" 9-1/8" 16" 16-1/8" SPR7WTB 1
increased performance and safety. 8" 10-1/8" 16" 16-1/8" SPR8WTB 1

12
Flashings and Storm Collars
To determine what Roof Flashing you’ll require, you must work out the ROOF FLASHING SELECTION CHART
pitch of your roof. To determine the pitch, you’ll need two rulers and a
level. Measure the number of inches from the end of the level down to
the roof.

In this example, the pitch is 3/12.


0/12 - 6/12 Roof Pitch = JSC 6 or 7 AAF
6/12 - 12/12 Roof Pitch = JSC 6 or 7 AF2

• Used where the chimney passes through a roof with a pitch of Flat ADJUSTABLE FLASHING ASSEMBLY-
to 6/12 FLAT TO 6/12
• Comes complete with Storm Collar
• All seams are sealed with Silicone Sealant
• Galvalume construction

Size A Product Code Pack


5" 24" x 24" JSC5AAF-3 3
6" 24" x 24" JSC6AAF-3 3
7" 24" x 24” JSC7AAF-3 3
8" 27-1/2" x 27-1/2" JSC8AAF-3 3

• Used where the chimney passes through a roof with a pitch of 6/12 ADJUSTABLE FLASHING ASSEMBLY-
to 12/12 6/12 TO 12/12
• Comes complete with Storm Collar
• All seams are sealed with Silicone Sealant
• Galvalume construction

Size A Product Code Pack


5" 30" x 21-1/2" JSC5AF2-3 3
6" 30" x 21-1/2" JSC6AF2-3 3
7” 30" x 21-1/2" JSC7AF2-3 3
8" 30" x 21-1/2" JSC8AF2-3 3

• Used on flat roof surfaces TALL CONE FLASHING


• All seams are sealed with Silicone Sealant
• Comes complete with Storm Collar

Size A B Product Code Pack


5" 24" 12" JSC5ATC 3
6" 24" 12" JSC6ATC 3
7" 24" 12" JSC7ATC 3
8" 24" 12" JSC8ATC 3

13
Flashings and Storm Collars continued
PEAK FLASHING - 3/12 TO 6/12 • Available in 7" only
• Required where the chimney passes through a peaked roof with a
pitch of 3/12 to 6/12
• Comes complete with Storm Collar

Size A B Product Code Pack


7" 22" 10" JSC7P1 1

PEAK FLASHING - 7/12 TO 9/12 • Available in 7" only


• Required where the chimney passes through a peaked roof with a
pitch of 7/12 to 9/12
• Comes complete with Storm Collar

Size A B Product Code Pack


7" 20" 14" JSC7P2 1

RUBBER BOOT FLASHING KIT • This kit fits 5", 6", 7" and 8" Chimneys
• Used where the chimney passes through a corrugated roof
• Rubber Boot Flashing fits roof pitches up to 12/12 (10/12 for 8")
• Kit includes rubber boot, spacer kit, special storm collar and
mounting hardware

Size Product Code Pack


ALL JURBFK1 1

ALUMINUM STORM COLLAR Used in conjunction with Roof Flashing to keep precipitation out.

B Size A B Product Code Pack


5" 7” 5-1/2" JSC56ASC-1 1
6" 8” 5-1/2" JSC56ASC-1 1
7" 9” 5-1/2" JSC78ASC-1 1
8" 10” 5-1/2" JSC78ASC-1 1

SILICONE SEALANT FOR STORM COLLAR Used to seal Storm Collar to chimney length above cone of flashing.

Size Product Code Pack


3 ounce tube JRTV 1

14
Premium Rain Caps
• Advanced design, premium quality stainless steel DELUXE RAIN CAP
• Provides protection against the elements
• Twist-lock connection for secure installation

Size A B C Product Code Pack


5" 7" 7-1/8" 11-1/4" SPR5DRC 1
6" 8" 7-1/4" 11-1/4" SPR6DRC 1
7" 9" 7-1/2" 13-1/4" SPR7DRC 1
8" 10" 7-5/8” 14-1/4" SPR8DRC 1

Stainless steel mesh wire fits inside Rain Cap. SPARK ARRESTOR

Size Dimensions Product Code Pack


5" 4-1/2" x 26" JSC5SPAR 10
6" 4-1/2" x 26" JSC6SPAR 10
7" 4-1/2" x 29" JSC7SPAR 10
8" 4-1/2" x 32" JSC8SPAR 10

15
Parts and Accessories
UNIVERSAL WALL BAND • Provides lateral support for the chimney when installed adjacent
to a wall
• Provides more than 4" of horizontal adjustability to clear some
overhangs and obstructions
• Required at 8 foot or closer intervals to stabilize the chimney,
whenever it is supported along a vertical wal

Size A B C Product Code Pack


6" to 8" 8" to 10" 17" 4" JSC-UWB 1

WALL BAND • Stainless steel construction


• Provides lateral support for the chimney when installed adjacent to a
wall
• Maintains the mandatory 2" clearance to combustibles
• Installed on first length above the Tee, then every 8 feet thereafter

Size A B Product Code Pack


5" 7" 17" JSC5WB 1
6" 8" 17" JSC6WB 1
7" 9" 17" JSC7WB 1
8" 10" 17" JSC8WB 1

BLACK STOVE PIPE ADAPTER • For a quick and easy transition from black stove pipe to factory-built
chimney
• Twist-lock for easy connection

Size A B C Product Code Pack


5" 7" 5" 5" JSC5ASE 1
6" 8" 6" 5" JSC6ASE 1
7" 9" 7" 5" JSC7ASE 1
8" 10" 8" 5” JSC8ASE 1

16
Parts and Accessories continued
• Used where the chimney passes through a soffit to provide a finished FINISHING PLATE
appearance
• Maintains the mandatory 2" clearance to combustibles

Size A B Product Code Pack


5" 7-1/8" 13" JSC5FP 1
6" 8-1/8" 14" JSC6FP 1
7" 9-1/8" 15" JSC7FP 1
8" 10-1/8" 16" JSC8FP 1

• Designed to provide extra stability for chimney system above roof line HEAVY DUTY UNIVERSAL ROOF BRACE KIT
• Required when the chimney extends 5 feet or more above the roof.
Use one kit every 5 feet
• Telescoping legs can adjust from 5' to 9'
• Support band adjusts to fit 6", 7", and 8" chimney

Size Dimensions Product Code Pack


6" to 8" Band adjusts 8" to 10" 0843900 1

• Designed to deflect snow and ice while preventing unnecessary strain UNIVERSAL SNOW SPLITTER
or damage to chimney
• Mounts directly above chimney pipe with easy panel assembly
• Made from heavy gauge galvanized steel

Size Product Code Pack


5" to 8" 2001922 1

• Insulation for use with: JUSI-UNIVERSAL SHIELDING


- Attic Insulation Shield (JSC*AIS) INSULATION
- Wall Thimble (SPR*WTB)
- Cathedral Ceiling Support (SPR*CCSB)
• Reduces cold air infiltration into the dwelling
• Provides additional protection against heat from the chimney

Size Dimensions Product Code Pack


Universal 2" x 12" x 48" JUSI 1

17
Fireplace Parts
ADAPTOR PLATE Used on masonry fireplaces and with specific factory-built fireplaces
listed to UL 127 or CAN/ULC-S610.

Size A B Product Code Pack


5" 7" 11-5/8" JSC5AP 1
6" 8" 11-5/8" JSC6AP 1
7" 9" 11-5/8" JSC7AP 1
8" 10" 11-5/8" JSC8AP 1

INSULATED CHASE PLUG • Recommended to reduce air infiltration through the chase in cold
climates
• Maintains the thermal envelope of your home
• For use with wood-burning fireplaces certified with Model SPR chimney
• A trim plate is provided when a 6" chimney is used
• Used with specific factory-built fireplaces listed to UL 127 or
CAN/ULC-S610

Size A B C Product Code Pack


6" & 7" 15" 15" 4-1/4" JSC7CP 1

30°/45° INSULATED WALL PLUG • For use where the chimney passes through a wall at a 30° & 45°
angle
• Insulated to maintain the thermal envelope of your home
• For use with wood-burning fireplaces certified with Model SPR
chimney
• A trim plate is provided - to be used when a 6" diameter chimney is
used with 30° or 45° angle or when a 7" diameter chimney is used
with 45° angle
• Used with specific factory-built fireplaces listed to UL 127 or
CAN/ULC-S610

Size A B C Product Code Pack


6" & 7" 15" 15" 4-1/4" JSC7WC 1
NOTE: 45º angle can only be used in Canada.

18
Support Kits
SUPERPRO HAS PUT TOGETHER 3 CHIMNEY KITS TO GET YOUR PROJECT DONE...
SuperPro has taken the guess work out of chimney installation by putting the most common parts for each installation all in one box. These 3 kits depict
the most common installations. Simply decide which of these scenarios fits your need, then pick up your chimney lengths, roof flashing and elbows (if
required).

When your chimney goes up through a flat ceiling, then thru the roof, CEILING SUPPORT KIT
you may choose the MODEL SPR DECORATOR CEILING SUPPORT
INSTALLATION KIT - SPR*DCSK Size Product Code
• Deluxe Rain Cap 5" SPR5DCSK
• Attic Insulation Shield 6" SPR6DCSK
• Decorator Ceiling Support 7" SPR7DCSK
• Stove Pipe Adaptor 8" SPR8DCSK

NOTE: For a two story application, an additional Firestop Radiation


Shield must be installed.
...Now you just need your roof flashing and chimney lengths.

When your chimney goes out a cathedral or open beam ceiling, you may CATHEDRAL CEILING SUPPORT KIT
choose the MODEL SPR CATHEDRAL CEILING SUPPORT INSTALLATION
KIT - SPR*CCSK Size Product Code
• Deluxe Rain Cap 6" SPR6CCSK
• Cathedral Ceiling Support 7" SPR7CCSK
• Draw Band 8" SPR8CCSK
• Trim Kit
• Stove Pipe Adaptor
...Now you just need your roof flashing and chimney lengths

When your chimney goes out a wall and then runs straight up, you’ll WALL SUPPORT KIT
need the MODEL SPR WALL SUPPORT INSTALLATION KIT - SPR*WSK
Size Product Code
• Deluxe Rain Cap
5" SPR5WSK
• Wall Bands (2)
• Stove Pipe Adaptor 6" SPR6WSK
• Wall Thimble 7" SPR7WSK
• Stainless Steel Tee 8" SPR8WSK
• Adjustable Wall Support (WS) with Non-Twist Lock Insulated Tee Cap
...Now you just need:
• Vertical Chimney lengths
• Through the wall length (must extend at least 3" into the room)

19
Notes
Notes
Notes
Notes
For training, detailed product information, downloadable
catalogs and installation instructions visit our website:

selkirkcorp.com selkirkcorp.ca

Selkirk Corporation Selkirk Canada Corporation


5030 Corporate Exchange Blvd. 950 South Service Road
Grand Rapids, MI 49512 Second Floor
Stoney Creek, ON L8E 6A2
phone: 1.800.992.VENT (8368)
email: info@selkirkcorp.com phone: 1.888.SELKIRK (735.5475)
email: cscanada@selkirkcorp.com

Complete Linecard

residential roof curbs & access rooftop residential filters* duct grilles, commercial
chimney equipment doors products* vent components registers, industrial vent
rails diffusers

*Some exceptions apply


© 2021 Selkirk. All rights reserved. SPR001-US-E 05/2021

You might also like