IVW-Software Application Brochure
IVW-Software Application Brochure
IVW-Software Application Brochure
Product Introduction
http://www.sinovision-tech.com/En/index.html
The Insight Vision Workstation (IVW) is a workstation for viewing and processing medical images. It
can receive digital images and data from a variety of medical equipment, including CT, MR, US, RF as
well as other digital radiation equipment. The IVW can store, transmit, process and display images on
local hard disks, and can also perform the above operations on images stored in a distributed manner
1/1
Application List
CTA Applications
Vessel Analysis *
Stent Planning *
TAVI *
2/2
Everywhere is workplace,
work together seamlessly.
Interface for transfer of medical images and information using the DICOM standard. Facilitates
communication with devices from different modality.
PACS/RIS CT Scanner
IVW
3/3
Routine Applications
Image data retrieval: provide patient information retrieval, open examination, patient
image loading, reports, film layouts, import and export, as well as sending and burn
images.
DICOM3.0 standard: local storage and management of image data, remote transmission,
import and export, disc backup and burning, image processing, 3D reconstruction,
4/4
Routine Applications
modifying basic patient information, examination information and fast data query.
System setting: Change the system setting to facilitate the user needs. 2D four-corner
printing template settings, data source settings, account management settings and
protocol settings.
5/5
Routine Applications
Remote query: In the workstation, image data can be queried and obtained from other
Patient information can be quired according to query conditions and image browsing
Film layout and printing: provide film layout, film settings and printing functions
a. Display the current total number of layouts of the current window, show the current
layout number, display the number of images and the number of existing images of the
b. Zoom and reset buttons are of use when the layout is more than one page. Click the
zoom button to maximize the view of current layout, and then click the reset button to
c. Provides common layouts 4X4, 4X5, 4X6, 5X6, 5X7, and tooth layout 1/4X4, 1/4X5,
6/6
Routine Applications
Report editing: Report editing function includes report writing area, image area, quick
input template area, and function button area. Users can write reports with descriptions,
diagnoses, and suggestions, and include images in the reports. The input template can
quickly fill in the description, diagnosis, and suggestion areas of the report with frequently
used words, reducing the amount of input from users. Users can replace, add, edit, delete,
Advanced report function: When using advanced applications such as Lung Nodule
Analysis and Bone Mineral Density Analysis to send and generate reports, advanced report
page is entered, the report is stored in PDF format and cannot be edited after generation.
7/7
Routine Applications
2D image viewer
a. Displays, loads, and checks 2D images, including images, rulers, four corners information,
b. Displays the sequence thumbnail of the loaded examination. When multiple examinations
are loaded, double-click the sequence thumbnail and the corresponding sequence image
is displayed.
c. Interface layout adjustment: The sequence layout has two layouts: horizontal and vertical.
It provides 5 preset sequence layouts, 1X1, 1X2, 1X3, 2X2, 3X1 as well as 1 positioning
image layout mode, 1 custom layout. The default is 2*2 layout when the system starts.
Image layout provides four preset image layouts and custom image layout modes: 1X1,
d. Multiple image manipulation tools are offered, including panning, zooming, magnifying,
ROI zooming, and automatic Window width and window level adjustment, ROI window
width and window level adjustment, dual mode window width and window level
8/8
Routine Applications
adjustment, mouse control window width and window level adjustment, clockwise 90
mirroring, cropping, pseudo-color, image reversal, small angle rotation and reset to
original position.
e. A variety of preset window width and window level values are available, including brain
tissue, pituitary, orbit, bone, sinus, inner ear, throat, and neck.
f. Image browsing function includes five operations: the first page; the previous page; play;
the next page and the last page. The play can be set to loop play or forward sequence
measurement. It mainly includes tools such as circle, rectangle, polygon, pixel, straight
line, angle, scale, peak curve, text, arrow, gap measurement, hand-drawn curve
annotation and cross line annotation. It supports customized panel display setting.
h. Additional functions include opening and clearing images, sending, and printing reports.
9/9
Routine Applications
Multi-planar reconstruction (MPR): The image display window realizes output through
the combined layout of multiple basic windows. The basic windows are cross section, coronal
plane, sagittal plane, and oblique plane. The content displayed in the basic image display
ruler, and orientation box. It supports batch processing mode, support definition of layer
number, layer spacing, layer thickness, FOV, offset, angle and drawing mode, as well as
playback batch processing. It provides three playback speeds, fast, medium, and slow.
10 / 10
Routine Applications
3D: It displays cross section, coronal plane, sagittal plane section and three-dimensional
visualization image. Layout and display mode may be adjusted to achieve different image
display requirements, including 2D, MIP, AIP, MinIP, SSD and VR. Layout settings provide two
11 / 11
Routine Applications
One-click bone removal: Click the bone removal button in the VR view to achieve bone
removal function. The default upper and lower limits of the bone removal threshold are
3071HU and 200HU, respectively. The user can also manually input the threshold.
One-click patient table removal: Click the patient table removal button to automatically
Virtual Endoscopy: Visualize the cavity and anatomy in the 3D volume mode and realize
flying and roaming in the cavity. Supports the linkage display of MPR and VE. The eye
positioning depth of field is adjustable from 1-10cm. The default is 4cm. It supports roaming
path definition, spacing setting, editing and playback, as well as adjustment of playback
It supports roaming records and saves to the list. It supports saving as video in avi format,
adjustment and editing of opacity, and it can be controlled through the keyboard and panel.
12 / 12
Lung Applications
It performs lung segmentation and extracts nodules within the selected image sequence,
calculates lung volume, lung nodule volume, number of lung nodules, and describe nodule
position, shape, edge, volume, thoracic features, bronchial features, blood vessel features,
and average CT value. Achieves effective evaluation of lung nodules and generates nodule
reports.
13 / 13
Lung Applications
diameter, maximum area, maximum diameter, maximum, minimum, and average CT value,
calculation of volume change rate and matching nodule double time. It effectively evaluates
14 / 14
Lung Applications
Using CT chest scan images, it performs lung parenchymal extraction, lung trachea extraction,
lung lobes segmentation, emphysema extraction and calculation of lung volume occupied by
emphysema. LFA is a powerful tool for clinicians to evaluate the structure and function of
lung tissue. It can distinguish whether patients have emphysema or small airway disease,
It provides automatic extraction, including left and right lung parenchyma, lung trachea and
It automatically calculates the volume of emphysema, and generates reports, including left
lung, right lung and whole lung, emphysema volume, total volume and emphysema
proportion.
It provides lung segmentation and lists display, including left lung, upper left lung, lower left
lung, right lung, upper right lung, middle right lung, lower right lung and trachea. It
separately displays the lung volume, emphysema volume, total volume, and emphysema
proportion.
15 / 15
Lung Applications
It automatically segments the lungs, extracts the nodules, and calculates the lung nodule
volume, shape, location, edge, pleural characteristics, bronchial characteristics, blood vessel
as the volume change rate and doubling time required for future follow-up and comparison.
It supports manual nodule modification, which can be divided into 4 methods: zoom, contour,
16 / 16
Lung Applications
It automatically segments the lungs, extracts the lesions, calculates the lesion volume,
describes the location of the lesions, effectively evaluates pneumonia, and generates reports.
the volume, effective diameter, location, and other information about the lesion, and provides
effective information such as the volume change rate and doubling time required for future
follow-up.
17 / 17
Neurology Applications
18 / 18
Neurology Applications
19 / 19
CTA Applications
It observes the anatomical parts and pathological characteristics of the blood vessels of the
head, neck, chest, abdomen, and lower extremities. Automatic and manual tools are used to
evaluate the size of blood vessels, abnormal area sizes, areas, stenosis locations, calcification
It automatically extracts carotid artery, abdominal aorta, and lower extremity arterial tissue.
It has automatic, semi-automatic and manual interaction methods for definition and editing
of blood vessel centerline, drawing, and editing of blood vessel contour, definition of stenosis,
plaque, and calcification. It evaluates the diameter and area of the blood vessel, and the
location of the stenosis. Information includes blood vessel cross-sectional area, equivalent
diameter, maximum diameter, minimum diameter, location, reference location name and
contour line, plaque area, total volume, calcified area, as well as total volume.
20 / 20
CTA Applications
21 / 21
CTA Applications
TAVI (optional)
It automatically locates the aortic valve annulus plane, aortic sinus annulus plane, sinus
coronal connection plane, ascending aorta plane, and left and right coronary opening
positions. It automatically calculates the area of the plane, diameter, distance from opening
to annulus plane, C-arm angle, and other information, while providing interactive manual
tools to assist in quantitative analysis of the aortic annulus before surgery.
22 / 22
Cardiac Applications
23 / 23
Cardiac Applications
24 / 24
Cardiac Applications
25 / 25
Cardiac Applications
26 / 26
Cardiac Applications
FFRct (optional)
FFRct is an analysis application for clinically predicting the decreasing trend of blood flow
pressure in patients with coronary artery stenosis, which is mainly developed by using CT
images bases on the principle of coronary blood flow hydrodynamics and computer
simulation technology.
The analysis results include not only the positioning of coronary artery stenosis and the
quantitative analysis of plaque lesions, but also the physiological and functional evaluation
of the coronary artery to assist more detailed analysis and diagnosis.
Evaluation results include pressure, average pressure, average flow rate, FFR
It can calculate the FFR value of the coronary artery based on segmentation, analysis, and
VR displays. The user can browse the FFR value distribution at any position of the coronary
tree and can also analyze the change of the coronary blood flow pressure, speed, and
influence through the pseudo-color model.
27 / 27
Cardiac Applications
28 / 28
Liver Applications
29 / 29
Liver Applications
The hepatic artery, portal vein or splenic artery may be manually selected, and define the
time of perfusion to complete the calculation of perfusion parameters.
It can provide automatic measurement and analysis, quantitative analysis of the ROI area
on the calculated perfusion parameter map, and calculation of related measurement
indicators including hepatic artery perfusion (HAP), portal vein perfusion (PVP), total liver
perfusion (TLP), Hepatic Artery Perfusion Index (HPI), Portal Vein Perfusion Index (PPI) and
Time to Peak (TTP), which are displayed in a table.
It automatically generates a ROI time density curve (TDC) and supports the replacement of
the pseudo-color.
30 / 30
Oncology Applications
31 / 31
Oncology Applications
32 / 32
Oncology Applications
33 / 33
Other Applications
34 / 34
Other Applications
It receives segmentation results from other applications, and transforms the organization
into a grid model, and then displays and optimizes the grid model through the functions
provided by the function panel such as model classification, model visualization, model
rendering, model post-processing, and model output.
35 / 35
Other Applications
36 / 36
Other Applications
The multi-layer mode extracts and analyzes fat information from the selected starting layer
and ending layer interval. The system automatically selects the most characteristic interval
and extracts the fat and contours. The fat information is displayed in the center of the
window. The fat information includes the subcutaneous fat volume (SFV) in the selected
interval, the visceral fat volume in the selected interval (VFV), the total fat volume (TFV),
the sum of VFV/TFV, and the current subcutaneous fat area (SFA), current visceral fat area
(VFA), total area of the current layer (TFA), VFA/TFA ratio, waist circumference and body
mass index (BMI) of the current layer. The user can see each layer in the selected interval
by adjusting the layer. Contours can be edited manually or semi-automatically.
37 / 37
Other Applications
38 / 38
Other Applications
SinoCloud
39 / 39
IVW Hardware Requirement