IECEx BAS 10.0045X 000
IECEx BAS 10.0045X 000
IECEx BAS 10.0045X 000
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Equipment: The W21 Range of Small Induction Motors – Frame Sizes 63 to 355
Optional accessory:
Type of Protection: Equipment protected by type of protection ‘n’, Equipment dust ignition protection by enclosure ‘t’.
Marking: Ex nA IIC T3 Gc
Ex tc IIIB T125 °C Dc IP (see original schedule)
Ex tb III C T125 °C Db IP6X (see schedule)
Tamb (See description)
Signature:
(for printed version)
Date:
Additional WEG (Nantong) Electric Motor WEG Euro - Industria Electrica S.A.
manufacturing Manufacturing Co., Ltd. Rua Eng Frederico
locations: 128#, Xin Kai South Rd., Nantong Sector V
ETDA, Jiangsu Province, P.R. China Apartado 6074
Zip : 226010 4476-908
China Maia
Portugal
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended
STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
Edition:4
IEC 60079-31:2008 Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure 't'
Edition:1
This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.
Test Report:
GB/BAS/ExTR10.0072/00
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
The W21 Range of Small Induction Motors has shaft centre heights ranging from 63 to 355mm and comprises cast iron or aluminium frames
for horizontal or vertical, foot and/or flange mounting. The flanges may be oversize or undersize as required and the shell provides a degree
of protection of at least IP55. The range covers 2 to 10 pole 3 phase windings for 50 or 60Hz and is designed for connection to supplies up
to 1000V and up to 1100V for dust only applications. Two speed motors are also included in the range.
Refer to the Annex to this certificate for the full description of the equipment.
2. The installer must ensure that any equipment certified cable glands and stopping plugs fitted to the terminal boxes are suitably IECEx/ATEX
approved. Any unused cable entries must be fitted with IECEx/ATEX certified stopping plugs. When installed the cable gland or stopping plug
must maintain the marked IP rating of the enclosure.
3. All terminal nuts and screws, whether used or not, shall be correctly tightened.
4. When tightening supply connections care should be taken to maintain clearance distances.
5. On auxiliary terminals the conductor insulation shall extend to within 1mm of the terminal throat.
7. The stator RTDs and thermistors must be connected as simple apparatus into intrinsically safe circuits.
9. Where auxiliary apparatus is fitted that is not covered by this certificate the installer and/or user, as appropriate, must ensure that it is
suitable for the conditions of use and that it does not invalidate this certification.
Annex:
The W21 Range of Small Induction Motors has shaft centre heights ranging from 63 to 355mm and comprises
cast iron or aluminium frames for horizontal or vertical, foot and/or flange mounting. The flanges may be
oversize or undersize as required and the shell provides a degree of protection of at least IP55. The range
covers 2 to 10 pole 3 phase windings for 50 or 60Hz and is designed for connection to supplies up to 1000V
and upto 1100V for Dust only applications. Two speed motors are also included in the range.
Bearing Arrangements
Spigots are machined at either end of the stator frame onto which the machined spigot housings of cast iron
end frames are fitted. The end shields carry the bearing arrangements which are ball or angular contact and
may be grease or oil lubricated. Optional bearing insulation is available and the bearing housings may be
cast or fabricated.
Stator
The stator core packs are built from insulated steel laminations which are clamped together. The wound and
impregnated stator assembly is secured in the stator frame by an interference fit.
Rotor
The rotor core packs which are built from insulated steel laminations are interference fit onto the steel shaft.
The rotor cage is die-cast aluminium and balancing of the rotor is achieved by fixing washers to cast studs on
the aluminium rotors. Double shaft extensions are included in the range. The construction of the rotor is
assessed against Table 6 of IEC 60079-15:2010 and appropriate action taken if the results dictate it is
required.
Terminal Arrangement
The motors are fitted with separate bolt-on cast iron terminal boxes fitted with bolt-on covers incorporating a
gasket which is glued to one surface.
Main terminal boxes contain cast polyester resin/fibre glass insulator blocks incorporating steel terminal studs,
earthing terminals and optionally auxiliary terminals.
Auxiliary terminal boxes contain IECEx/ATEX component certified terminals. Details of which are shown
below:
The WEG ATEX only component certified terminals have been accepted in accordance with IECEx
Operational Document OD009 Clause A.2.2 as detailed in the report GB/BAS/ExTR10.0072/00.
Optionally the auxiliary terminal box may be integrally cast with the main terminal box or be a bolt-on addition
to the main terminal box.
Page 1 of 3
Baseefa
Rockhead Business Park
Staden lane, Buxton, Derbyshire
SK17 9RZ
United Kingdom
Ventilation
Various methods of cooling are used including TEBC, TEFC, TEAO or TENV. For TEBC versions a
separately IECEx/ATEX certified blower motor is utilised and optionally an IECEx/ATEX certified encoder may
be attached to the main motor shaft.
External fans when used are manufactured from polypropylene, cast iron, bronze or aluminium containing
less than 6% magnesium.
Windings
The low voltage motors are wound using polyester-imide enamel wire with the overhangs suitably insulated
and tied with string in order to compact them and keep the insulation between phases in place.
The W21 range of small motors may be operated with frequency inverters (variable speed drives) in the
following conditions:
- For a motor to operate with the restriction of optimal flux the motor has to be IE2 High Efficiency rated
or higher and the motor is to be supplier by a WEG inverter (Type CFW09 version 2.40 or higher, or
the CFW11) and be de-rated according to WEG's de-rating curve.
- Use of WEG PWM inverters (variable speed drives) or equivalent brand with carrier frequency from
2000 Hz up to 20000 Hz, with a frequency range up to 100 Hz or in accordance with manufacturer's
recommendations.
- When motors are operated below 50 Hz with contact torque loads, a de-rating factor as per WEG's
de-rating Curve for Motors fed by Inverters shall be applied.
- Motors shall be fitted with thermal protective devices which shall be connected into the motor control
circuit in order to maintain the T3 temperature class.
Auxiliaries
- Anti-condensation heaters
- Winding temperature detectors comprising RTD's, thermocouples or thermistors.
Ambient Temperatures
The standard temperature range of the motors is -20°C to +50ۡ°C. By the choice of suitable materials and use
of the de-rating data called up on the drawings an ambient range of -55°C to 80°C may be achieved.
Individual motors must be marked according to the build of the unit.
Page 2 of 3
Baseefa
Rockhead Business Park
Staden lane, Buxton, Derbyshire
SK17 9RZ
United Kingdom
The ingress protection rating of the motors depend on the shaft seal used:
Page 3 of 3