Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Test Report

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TEST REPORT Page 1 of 1

Report No. PTCS-23-24-89207-4-0 Report date 06-09-2023


Party Name & Add. Ansox Industries Pvt. Ltd
GAT.NO-679/17, BALAJI IND ESTATE,ALANDI PHATA, KHED, PUNE-410501
Lab No. PTCS-23-24-89207-4 Sample Received on 02-09-2023
Ref. No & Date 3097 01-09-2023 Test Completed on 06-09-2023
Specification IS 4454(Part 4) : 2001 Grade- 1 X07Cr18Ni9
Sample Description Part No- 0134161000, Seat Housing
Sample Drawn By Party

4+1+1*

*PTCS-23-24-89207-
Test : Micro Vickers Hardness

Discipline : Mechanical, Group : Mechanical Properties of Metals


Micro Vickers Hardness Test Temperature :23.5 Test performed on : 04-09-2023
Test Method : ASTM E92:2017 Tested By : Deepak Shivpuje
Parameter Result
Test force (kgf.) HV 0.1
Micro Vickers Hardness Value (HV) 348,351,354
Average 351.00
Remark: --
…………..END OF REPORT………….

Ravindra Ghugal Ravindra Ghugal


Technical Manager Technical Manager
Reviewed by Authorised Signatory

Terms & Conditions:


1.This report relates to the sample (s) submitted and tested 2. Sample(s) are submitted by the customers and not drawn by the M/S Phoenix Testing And Consultancy
Services (PTCS).3. Report shall not be reproduced except in full, without prior written permission of PTCS. 4. Any correction to report without authorization invalidates
report and all dispute subject to Pune jurisdiction.5. The details documentation in the Sample description are as provided by the customers in their challan/letter/test
request. 6. While PTCS has made best endeavors to provide accurate and reliable information, liability of PTCS is limited to the value of the testing charges billed for the
respective sample (s) and PTCS is not responsible for any financial liability due to any act of omission or error. 7. Sample are retained by PTCS for 30 days. If required, please
arrange to collect the balanced sample(s), if any, within this time frame. Any request to retest or extra test should be intimated to PTCS with 15 days. PTCS cannot take
responsibility to return the balance sample (s) at the client premises.
For Report
Doc No:-PTC/LAB/F/001