TCP/IP ports on the XCC, IMM2 and CMM

management processors
Reference Information

The systems management processors (also known as service processors) integrated in ThinkSystem,
System x, Flex System, and BladeCenter servers use a variety of TCP/IP ports for communication. This
document lists them and indicates which ones the administrator can and cannot change. You need to
ensure that your network (firewalls and routers) allows communications through these ports for the
management processor to function properly.
The management processors covered are:
XClarity Controller (XCC)
Chassis Management Module (CMM and CMM2)
Integrated Management Module II (IMM2 and IMM2.1)
Integrated Management Module (IMM)
BladeCenter Advanced Management Module (AMM)
BladeCenter Management Module (MM)
Remote Supervisor Adapter II (RSA II)
Baseboard Management Controller (BMC)

XClarity Controller (XCC) Click here to check for updates


TCP/IP ports on the XCC, IMM2 and CMM management processors 1
XClarity Controller (XCC)
The following ports are used by XCC. Ports are either fixed or configurable as noted. For configurable ports,
the default port is listed.

Table 1. XCC ports


Port Port Fixed or
name number configurable Description
http 80 Fixed Web server HTTP connection (TCP)
https 443 Configurable SSL connection (TCP)
(default)
REST 443 Fixed REST over HTTPS
over SSL
CIM/XML 5989 Configurable CIM/XML HTTPS
HTTPS (default)
Remote 3900 Configurable Remote presence (TCP)
presence (default)
IPMI 623 Fixed IPMI over LAN
SLP 427 Fixed SLP connection (TCP/UDP)
SSDP 1900 Fixed Simple Service Discovery Protocol (UDP), required by Redfish DMTF
SSH 22 Configurable Secure Shell (SSH) command-line interface (TCP)
(default)
SNMP 161 Configurable SNMP get/set commands (UDP)
agent (default)
SNMP 162 Configurable SNMP traps (UDP)
traps (default)
HTTP 81 Fixed HTTP (TCP). Used for LXCM, only open in the front panel USB interface.
SFTP 115 Fixed SFTP File transfer (TCP)
RDP 3389 Fixed Remote Desktop Protocol USB-to-Ethernet interface (TCP). XCC acts as
traffic forwarding between the external network and the host.
VNC 5900 Fixed Virtual Network Computing remote desktop protocol (TCP). XCC acts as
traffic forwarding between the external network and the host.

TCP/IP ports on the XCC, IMM2 and CMM management processors 2


Chassis Management Module (CMM)
The Chassis Management Module (CMM and CMM2) is the service processor used in the Flex System
Enterprise Chassis. The following ports are user configurable. The default port numbers used are indicated.

Table 2. CMM ports -- user configurable


Port name Port number Description
http 80 (default) Web server HTTP connection - TCP
https 443 (default) SSL connection for HTTP-TCP
telnet 23 (default) Telnet command-line interface connection -TCP
SSH 22 (default) Secure Shell (SSH) command-line interface - TCP
SNMP agent 161 (default) SNMP get/set commands - UDP
SNMP traps 162 (default) SNMP traps
FTP 21 (default) FTP
FTP Data 20 (default) FTP Data
TFTP 69 (default) TFTP
CIM/XML HTTPS 5989 (default) CIM/XML HTTPS – used by mgmt. apps
TCP Command Mode 6090 (default) TCP Command Mode
Secure TCP Command Mode 6091 (default) Secure TCP Command Mode – used by mgmt. apps
SLP 427 (default) Service location protocol - UDP

The following TCP/IP ports are fixed and cannot be changed.

Table 3. CMM ports - fixed


Port number Description
25 E-mail alerts - TCP
53 DNS resolver - UDP
67 and 68 DHCP - UDP
547 DHCP (IPv6) - UDP
623 RMCP (Remote Management and Control Protocol)
50990 SNMPv3 traps
123 NTP
389 LDAP
636 LDAPS (secure LDAP)

Integrated Management Module and Integrated Management Module II (IMM2)


TCP/IP ports on the XCC, IMM2 and CMM management processors 3
Integrated Management Module and Integrated Management Module II (IMM2)
The following ports are user configurable. The default port numbers used are indicated.

Table 4. IMM and IMM2 ports -- user configurable


Port name Port number Description
http 80 (default) Web server HTTP connection - TCP
https 443 (default) SSL connection -TCP
telnet 23 (default) Telnet command-line interface connection -TCP
SSH 22 (default) Secure Shell (SSH) command-line interface - TCP
SNMP agent 161 (default) SNMP get/set commands - UDP
SNMP traps 162 (default) SNMP traps - UDP
Remote presence 3900 (default) Remote presence - TCP
CIM/XML HTTP 5988 (default) CIM/XML HTTP
CIM/XML HTTPS 5989 (default) CIM/XML HTTPS
NTP 123 (default) Network Time Protocol

The following TCP/IP ports are fixed and cannot be changed.


Table 5. IMM and IMM2 ports - fixed

Port number Description


25 E-mail alerts - TCP
53 DNS resolver - UDP
68 DHCP client connection - UDP
427 SLP connection - UDP
623 RMCP (Remote Management and Control Protocol)
3389 USB-to-Ethernet interface - TCP
5985 Web Services Management (WS-MAN) HTTP
5986 Web Services Management (WS-MAN) HTTPS
7070-7077 Partition management for multi-node servers

BladeCenter Advanced Management Module


TCP/IP ports on the XCC, IMM2 and CMM management processors 4
BladeCenter Advanced Management Module
The following ports are user configurable. The default port numbers used are indicated.
Table 6. AMM ports -- user configurable

Port name Port number Description


http 80 (default) Web server HTTP connection - TCP
https 443 (default) SSL connection -TCP
telnet 23 (default) Telnet command-line interface connection -TCP
SSH 22 (default) Secure Shell (SSH) command-line interface - TCP
SNMP agent 161 (default) SNMP get/set commands - UDP
SNMP traps 162 (default) SNMP traps - UDP
FTP 21 Listen port for the FTP server - TCP
FTP data 20 FTP data port - TCP
TFTP 69 TFTP server - TCP
Remote disk 1044 Remote disk function - TCP
Remote disk on-card 1045 Persistent remote disk (disk on card) - TCP
Remote KVM 3900 Remote Console - TCP

The following TCP/IP ports are fixed and cannot be changed.


Table 7. AMM ports -- fixed

Port number Description


25 E-mail alerts - TCP
53 DNS resolver - UDP
68 DHCP client connection - UDP
427 SLP connection - UDP
6090 IBM Director commands - TCP
13991 IBM Director alerts - UDP

BladeCenter Management Module


TCP/IP ports on the XCC, IMM2 and CMM management processors 5
BladeCenter Management Module
The following ports are user configurable. The default port numbers used are indicated.
Table 8. MM ports -- user configurable

Port name Port number Description


http 80 (default) Web server HTTP connection - TCP
https 443 (default) SSL connection -TCP
telnet 23 (default) Telnet command-line interface connection -TCP
SSH 22 (default) Secure Shell (SSH) command-line interface - TCP
SNMP agent 161 (default) SNMP get/set commands - UDP
SNMP traps 162 (default) SNMP traps - UDP

The following TCP/IP ports are fixed and cannot be changed.


Table 9. MM ports -- fixed

Port number Description


25 E-mail alerts - TCP
53 DNS resolver - UDP
68 DHCP client connection - UDP
427 SLP connection - UDP
1044 Remote disk function - TCP
1045 Persistent remote disk (disk on card) - TCP
5900 Remote Console video redirect - TCP
6090 IBM Director commands - TCP
13991 IBM Director alerts - UDP

Remote Supervisor Adapter II (RSA II)


TCP/IP ports on the XCC, IMM2 and CMM management processors 6
Remote Supervisor Adapter II (RSA II)
The following ports are user configurable. The default port numbers used are indicated.
Table 10. RSA II ports -- user configurable

Port name Port number Description


http 80 (default) Web server HTTP connection - TCP
https 443 (default) SSL connection -TCP
telnet 23 (default) Telnet command-line interface connection -TCP
SSH 22 (default) Secure Shell (SSH) command-line interface - TCP
SNMP agent 161 (default) SNMP get/set commands - UDP
SNMP traps 162 (default) SNMP traps - UDP

The following TCP/IP ports are fixed and cannot be changed.


Table 11. RSA II ports -- fixed

Port number Description


427 SLP connection - UDP
1044 Remote disk function - TCP
1045 Persistent remote disk (disk on card) - TCP
2000 Remote Console video redirect - TCP and UDP
6090 IBM Director commands - TCP
7070-7073 Scalable Partition management (x445) - TCP
7070-7077 Scalable Partition management (x460 and x3950) - TCP

Baseboard Management Controller (BMC)


The following TCP/IP ports are fixed and cannot be changed.
Table 12. BMC ports

Port number Description


623 IPMI communications to SMBridge and IBM Director
664 IPMI communications (secondary)
161 SNMP get/set commands
162 SNMP traps and PET alerts to Director

Related product families


TCP/IP ports on the XCC, IMM2 and CMM management processors 7
Related product families
Product families related to this document are the following:
1-Socket Rack Servers
1-Socket Tower Servers
2-Socket Rack Servers
2-Socket Tower Servers
4-Socket Rack Servers
8-Socket Rack Servers
Blade Servers
System Utilities

TCP/IP ports on the XCC, IMM2 and CMM management processors 8


Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your
local Lenovo representative for information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product,
program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any
Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify
the operation of any other product, program, or service. Lenovo may have patents or pending patent applications
covering subject matter described in this document. The furnishing of this document does not give you any license to
these patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.


8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the
information herein; these changes will be incorporated in new editions of the publication. Lenovo may make
improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time
without notice.

The products described in this document are not intended for use in implantation or other life support applications
where malfunction may result in injury or death to persons. The information contained in this document does not
affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express
or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information
contained in this document was obtained in specific environments and is presented as an illustration. The result
obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply
in any way it believes appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any
manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials
for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was
determined in a controlled environment. Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level systems and there is no guarantee
that these measurements will be the same on generally available systems. Furthermore, some measurements may
have been estimated through extrapolation. Actual results may vary. Users of this document should verify the
applicable data for their specific environment.

© Copyright Lenovo 2023. All rights reserved.

This document, TIPS0511, was created or updated on August 3, 2022.


Send us your comments in one of the following ways:
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS0511
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/TIPS0511.

TCP/IP ports on the XCC, IMM2 and CMM management processors 9


Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other
countries, or both. A current list of Lenovo trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
BladeCenter®
Flex System
System x®
ThinkSystem®
XClarity®
Other company, product, or service names may be trademarks or service marks of others.

TCP/IP ports on the XCC, IMM2 and CMM management processors 10

You might also like