LEGEND:

ALL FIRE ALARM DEVICES MUST BE CONNECTED WITH POWER SUPPLY BECAUSE
IN CASE OF BATTERY OFF DEVICES CONTINUE WITH POWER SUPPLY FACP FIRE ALARM CONTROL PANEL

WEATHERPROOF ALARM BELL WITH


FLASHING LIGHT

SD SMOKE DETECTOR WITH BUILT IN BATTERY


DETECTOR DETECTOR
SD SMOKE
HEAT
HD STORE
HD HEAT DETECTOR WITH BUILT IN BATTERY
KITCHEN

EXTINGUISER TOIL.
PORTABLE FIRE BREAK GLASS CALL POINT

FIRE ALARM BELL 6"

END OF LINE RESISTOR


EOL

EL EMERGENCY LIGHT

EXIT
EXIT LIGHT

FDS FIRE RATED DOOR SELF CLOSE 2HOUR

DETECTOR
SD SMOKE
C CARBON MONOXIDE ALARM
DETECTOR
SD SMOKE
NOOK
PORTABLE FIRE EXTINGUISER
LIVING AREA
FAMILY

EXTINGUISER
PORTABLE FIRE

DETECTOR
HD
HEAT

DETECTOR
SD SMOKE
SITTING ROOM
MEN'S
FACP

TOIL.
FIRE ALARM CONTROL PANEL
DETECTOR
SD SMOKE

WASH
DETECTOR
SD SMOKE

DETECTOR
SD SMOKE

DETECTOR
SD SMOKE

DINING ROOM
UP

CARPORT

PROJECT :

DETECTOR
SD SMOKE DETECTOR
SD SMOKE PRIVATE VILLA
BOFI RIYADH CITY, KSA
ROOM TOIL.
DRIVER'S
DRAWING TITLE :

GROUND FLOOR FIRE ALARM SYSTEM

GROUND FLOOR FIRE ALARM SYSTEM 1:100

DELTA CONSULTING ENGINEERS

( DESIGN - SURVEY - SUPERVISION - ASSESSMENT - ESTIMATION )


RIYADH: 11692 TEL:(O1)4616060 P.O.BOX :89898
www.delta - ksa .com LICENSE No. 3711 FAX:(O1)4614040
ALL FIRE ALARM DEVICES MUST BE CONNECTED WITH POWER SUPPLY BECAUSE LEGEND:

IN CASE OF BATTERY OFF DEVICES CONTINUE WITH POWER SUPPLY FACP FIRE ALARM CONTROL PANEL

WEATHERPROOF ALARM BELL WITH


FLASHING LIGHT

SD SMOKE DETECTOR WITH BUILT IN BATTERY

HD HEAT DETECTOR WITH BUILT IN BATTERY

BREAK GLASS CALL POINT

FIRE ALARM BELL 6"


C DETECTOR
CARBON

DETECTOR
SD SMOKE
END OF LINE RESISTOR
EOL
DETECTOR
SD SMOKE

EL EMERGENCY LIGHT

EXIT
EXIT LIGHT

FDS FIRE RATED DOOR SELF CLOSE 2HOUR

C CARBON MONOXIDE ALARM

DETECTOR DETECTOR
SD SMOKE SD SMOKE PORTABLE FIRE EXTINGUISER

DETECTOR
SD SMOKE

DETECTOR
SD SMOKE

PROJECT :

PRIVATE VILLA
RIYADH CITY, KSA

DRAWING TITLE :

FIRST FLOOR FIRE ALARM SYSTEM


1 FIRST FLOOR FIRE ALARM SYSTEM 1:100

E 09

DELTA CONSULTING ENGINEERS

( DESIGN - SURVEY - SUPERVISION - ASSESSMENT - ESTIMATION )


RIYADH: 11692 TEL:(O1)4616060 P.O.BOX :89898
www.delta - ksa .com LICENSE No. 3711 FAX:(O1)4614040
ALL FIRE ALARM DEVICES MUST BE CONNECTED WITH POWER SUPPLY BECAUSE
LEGEND:
IN CASE OF BATTERY OFF DEVICES CONTINUE WITH POWER SUPPLY
FACP FIRE ALARM CONTROL PANEL

WEATHERPROOF ALARM BELL WITH


FLASHING LIGHT

SD SMOKE DETECTOR WITH BUILT IN BATTERY

HD HEAT DETECTOR WITH BUILT IN BATTERY

BREAK GLASS CALL POINT

FIRE ALARM BELL 6"

END OF LINE RESISTOR


EOL

EL EMERGENCY LIGHT

EXIT
EXIT LIGHT

DETECTOR
SD SMOKE
FDS FIRE RATED DOOR SELF CLOSE 2HOUR

C CARBON MONOXIDE ALARM


DETECTOR
SD SMOKE

PORTABLE FIRE EXTINGUISER

DETECTOR
SD SMOKE

DETECTOR
SD SMOKE
DETECTOR
SD SMOKE

* C : REFERS TO CEILING MOUNTED ITEM.


* W.P : REFERS TO WEATHER PROOF ITEM.

PROJECT :

PRIVATE VILLA
RIYADH CITY, KSA

DRAWING TITLE :

ROOF FLOOR FIRE ALARM SYSTEM

1 ROOF FLOOR FIRE ALARM SYSTEM 1:100

E 10

DELTA CONSULTING ENGINEERS

( DESIGN - SURVEY - SUPERVISION - ASSESSMENT - ESTIMATION )


RIYADH: 11692 TEL:(O1)4616060 P.O.BOX :89898
www.delta - ksa .com LICENSE No. 3711 FAX:(O1)4614040