Technical Data: Model GPY Electric Fire Pump Controller

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Technical Data

Model GPY Electric Fire Pump Controller

A4 Flow switch provision High water reservoir level c/w visual indication
C18
and alarm contact (DPDT)
Foam pump application w/o pressure
A8
transducer and run test solenoid valve. C19 Emergency start alarm contact (DPDT)
A9 Low zone pump control function C20 Manual start alarm contact (DPDT)
A10 Middle zone pump control function C21 Deluge valve start alarm contact (DPDT)
A11 High zone pump control function C22 Remote automatic start alarm contact (DPDT)
Non-pressure actuated controller w/o pressure C23 Remote manual start alarm contact (DPDT)
A13
transducer and run test solenoid valve
High pump room temperature alarm contact
Lockout/interlock circuit from equipment C24
A16 (DPDT)
installed inside the pump room
Second set of standard alarm contacts (DPDT)
Built in alarm panel (120V.AC supervisory C25
(Typical for city of Los Angeles and Denver)
power) providing indication for:
• Audible alarm & silence pushbutton for motor Additional visual and alarm contact (Specify
B11 Cx
run, phase reversal, loss of phase. function) (DPDT)
• Pilot lights for loss of phase & supervisory Low suction pressure transducer for fresh
power available D1 water rated at 0-300PSI with visual indication
Built in alarm panel same as B11 but 220- and alarm contact
B11B
240VAC supervisory power Low suction pressure transducer for sea water
High motor temperature c/w thermoster relay D1A rated at 0-300PSI with visual indication and
B19A alarm contact
and alarm contacts (DPDT)
High motor temperature c/w PT100 relay and Pressure transducer and run test solenoid
B19B D5 valve for fresh water rated for 0-500PSI (for
alarm contacts (DPDT)
factory calibration purposes only)
Ground fault alarm detection c/w visual
B21 Pressure transducer and run test solenoid
indication and alarm contact (DPDT) D5D
valve for sea water rated for 0-500PSI
C1 Extra motor run alarm contact (DPDT)
D10 Omit mounting feet (when applicable)
C4 Periodic test alarm contact (DPDT)
High withstand rating for:
C6 Low discharge pressure alarm contact (DPDT) • 200V to 208V @ 150HP max. = 150kA*
• 200V to 208V @ 200HP = 100kA*
Low pump room temperature alarm contact
C7 • 220V to 240V @ 200HP max. = 150kA*
(DPDT)
• 220V to 240V @ 250HP = 100kA*
Low water reservoir level alarm contact D13
C10 • 380V to 415V @ 300HP max. = 150kA*
(DPDT) • 380V to 415V @ 350HP to 450HP = 100kA*
High electric motor temperature alarm contact • 440V to 480V @ 400HP max. = 150kA*
C11 • 440V to 480V @ 450HP to 500HP = 100kA*
(DPDT)
• 600V @ 500HP max. = 100kA*
High electric motor vibration c/w visual
C12 High withstand rating for:
indication and alarm contact (DPDT)
• 200V to 208V @ 150HP max. = 200kA*
Pump on demand / automatic start alarm
C14 D13B • 220V to 240V @ 200HP max. = 200kA*
contact (DPDT)
• 380V to 415V @ 300HP max. = 200kA*
C15 Pump fail to start alarm contact (DPDT) • 440V to 480V @ 400HP max. = 200kA*
C16 Control voltage healthy alarm contact (DPDT) D14 Anti-condensation heater & thermostat
Flow meter valve loop open c/w visual
C17 D14A Anti-condensation heater & humidistat
indication and alarm contact (DPDT)

Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package.

This is a Marketing document. Please consult factory if additional information is required.


August 2020 Manufacturer reserves the right to modify this information without notice 7