PVC Coated Conduit Procedure
PVC Coated Conduit Procedure
PVC Coated Conduit Procedure
1.0 Definitions
The following words and phrases shall have the following definitions when used in this Procedure.
1.1 Manufacturer
A person, firm, corporation, or other business entity that manufactures PVC Coated Conduit.
1.2 Participant
Any person, firm, corporation, or other business entity which manufactures, assembles, or markets PVC Coated
Conduit. If a participant does not manufacture one or more of its verified products, the participant shall be
responsible for compliance with all requirements of the Procedural Guide to be performed by the manufacturer and
for the manufacturer's failure or refusal to comply with any such requirements.
1.3.1 Three 8 inch sections of PVC Coated Conduit taken from the threaded ends.
1.3.2 Three 8 inch sections of PVC Coated Conduit (without threads) taken from other than the threaded ends.
1.3.3 Three 8 inch sections of PVC Coated Conduit taken from the threaded ends and cut in half longitudinally to
allow access to the interior coating for evaluation.
1.3.4 Three 8 inch sections of PVC Coated Conduit (without threads) taken from other than the threaded ends and
cut in half longitudinally to allow access to the interior coating for evaluation.
1
Mark are to be designated by Intertek and are listed on the inspector’s selection sheet. The entire
production of a product which has the same design as the product that has been verified to meet the
requirements of the Intertek ETL SEMKO PVC Coated Conduit Verification Program shall bear the ETL
Verified Mark.
If products are produced with the ETL Verified Mark that are not listed on the Sample Selection Sheet, the
inspector shall notify the Program Administrator by phone and in writing of the brand name and the part number
using the Non-Compliance Report (Form PVC-001C).
2.5.1 Labeling
Each inspector is supplied with selection labels and/or ETL adhesive tape, and an Intertek Order Number for
each Participant. The Order Number and date of selection shall be written on the label, or visibly on the product
container. The labels, or tape, shall be applied so that opening of the product container would destroy the
integrity of the label. Also, the label information and the information on the product type are readily
recognized.
2
2.6 Inspector's Report to Intertek
The Inspection Report (Form PVC-001B) shall include the manufacturer name, location and contact at the
inspected plant, a record of the sample selection, the date of the inspection, the location of selection and a
general view of the inspection visit. On the report, the inspector shall note any of the following occurrences:
The Program Administrator will review all inspectors’ reports noting any variances and will direct inspectors to
verify corrections of these variances.
When performing the selection, the inspector shall follow the procedure indicated in Sections 2.4 and 2.5 of this
procedure.
3
Holding Areas
Incoming Receiving/Inspection/Storage
Identified with a sign
Segregated
Secured with a latched gate
Scrap
Identified with a sign
Segregated
Production
Production Machines
All test/measuring equipment calibrated and have calibration label affixed (some equipment is acceptable as
"For Reference Only" labeled)
Operators Stations
Measuring devices calibrated, calipers, micrometers, etc
Calibration
Is all test/measuring equipment in the following areas in current calibration?
Inspection
Incoming receiving
In process
Final
Calibration Laboratory
QC Laboratory
Functional/Operating machines
Final Test
Electrical characteristics
4
Dielectric (hipot)
Shipping Area
Scales
Items Selected:
Comments:
After Selection
Affix Intertek Inspector seal to protective wrapper seam
Observe PVC Coated Conduit while being prepared for shipment
Affix Intertek Inspector seal(s) to outside shipping "envelope"
Include in report to Intertek, product, certificate of conformance number of sample selected, and when shipped
5
Page ___ of ___
Date: _________________________________
ETL Order Number: _________________________________
Supplier: _________________________________
_________________________________
_________________________________
To: Kathy Heath
Program Administrator
Intertek ETL SEMKO
3933 US Route 11
Cortland, NY 13045
INSPECTION REPORT
Form PVC-001B
Page ___ of ___
Date: ___________________________________
ETL Order Number: ___________________________________
Supplier: ___________________________________
___________________________________
___________________________________
NON-COMPLIANCE REPORT
Form PVC-001C