Single Split DC-Inverter
Single Split DC-Inverter
Single Split DC-Inverter
Prior to
Warning
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
PCRSG0708B
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Organization: Organization:
DAIKIN INDUSTRIES, LTD. DAIKIN INDUSTRIES
AIR CONDITIONING MANUFACTURING DIVISION (THAILAND) LTD. All of the Daikin Group’s business
Scope of Registration: facilities and subsidiaries in Japan
Scope of Registration: are certified under the ISO 14001
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF THE DESIGN/DEVELOPMENT
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, international standard for
AND MANUFACTURE OF AIR environment management.
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, CONDITIONERS AND THE
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT COMPONENTS INCLUDING
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS USED FOR THEM
JMI-0107 COMPRESSORS AND VALVES. JQA-1452
Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved
Printed in Singapore 10/11/005 OX, P.C.
Specifications, designs and other content appearing in this brochure are current as of October 2011 but subject to change without notice.
1 2
FTKS25/35D
RKS25/35G
FTKS25DVM / RKS25GVMG
2.5 (1.2-3.2) kW
8,500 (4,050-10,900) Btu/h
FTKS35DVM / RKS35GVMG
3.5 (1.4-4.0) kW
11,900 (4,750-13,650) Btu/h
FTKS50B
FTKS50/60G
FTKS71HVMG / RKS71HVMG
7.1 (2.3-8.5) kW
24,200 (7,800-29,000) Btu/h
FTKS71H
RKS50B RKS50/60G
FTKS50BVMA / RKS50BVMG
5.00 (0.90-5.80) kW
17,070 (3,070-19,800) Btu/h
FTKS50GVMG / RKS50GVMG
5.0 (1.7-6.0) kW
RKS71H
17,100 (5,800-20,500) Btu/h
FTKS60GVMG / RKS60GVMG
*1 *2 6.0 (2.3-6.7) kW
*1 Available with FTKS50/60G only.
*2 Available with FTKS50B only. 20,500 (7,800-22,900) Btu/h
3 4
4 Tick Energy Label Energy-Saving Technological Features
The 5 models listed below have received Singapore’s 4 FTKS25D/RKS25G FTKS35D/RKS35G
Tick Energy Label, which is the highest energy-efficiency
rating for inverter type air conditioners. The energy COP 3.57 3.38 Swing Compressor
labeling was introduced by Singapore’s Ministry for the Thanks to its smooth rotation, the Swing bush
Refrigerant gas
Efficiency (%)
Comfortable Temperature Control consumption. The motor also
temperature. This makes inverter 80
provides improvements in DC motor
models more energy-saving than Approx.
operational efficiency of up to 40%, 60 20%
non-inverter models, which must Temp. increase
PAM (Pulse Amplitude Modulation)
compared to an AC motor. These 40
repeatedly start or stop their improvements are particularly
Approx.
40%
AC motor control reduces energy loss by
Not cool
compressors to maintain the room
Compressor off
noticeable in the low-speed range. 20 increase controlling how often the converter
0 switches on and off.
temperature. 200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
Set
temp. Compressor off *5. Data are based on studies conducted
Comfortable under controlled conditions at a Daikin
laboratory using Daikin products.
Inverter air conditioners finely adjust
Small temp.
capacity according to changes in the Cools a room difference
air-conditioning load and the difference in less time What Is DC Inverter?
Time
Too cool During cooling operation Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency
between the indoor temperature and
than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor
set temperature is small. These give Non-inverter type that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance
higher comfort levels than with non- Inverter type
DC motor.
Starts
inverter air conditioners. This diagram is a representation for illustrative purpose only.
5 6
Intelligent Eye Indoor Unit Quiet Operation
Intelligent Eye prevents energy wastage by using its Top view This series gives you the choice of 5-step, Quiet or
infrared sensor to detect human movement in a room. Automatic settings for the fan speed. The Quiet setting
When there is no movement, Intelligent Eye increases the selects Indoor Unit Quiet Operation. This function
7m
temperature by 2 C to give energy savings. decreases the operation sound level by 3 dB (A) below
This reduces energy wastage if, for example, you 110˚ the Low setting.
forget to turn off the air conditioner. The function can be This wide range of settings allows you to precisely
conveniently activated from the remote controller. control the fan speed according to your requirements.
Once Intelligent Eye is set, it continues to work to save energy. You do not For example, Indoor Unit Quiet Operation provides you
The Intelligent Eye Intelligent Eye Side view
need to push the SENSOR button each time you wish to use this function.
indicator lights when sensor 7m with a good night’s sleep. The sound level for FTKS25D
movement is detected.
is 22 dB (A).
FTKS25D
Fan speeds Sound levels
7 8
Titanium Apatite Photocatalytic
Air-Purifying Filter Mould-Proof Operation
Titanium apatite is a new photocatalytic When cooling or dry operation is stopped, fan-only
material with advanced adsorption power. While operation runs automatically for 1 hour. This airflow
the filter’s micron-level fibres trap dust, this photocatalyst dries the inside of the indoor unit to reduce the
effectively adsorbs and decomposes bacteria. generation of mould and odours. It is available with
Air filter
The photocatalyst is activated simply by exposure to Catches dust FTKS25/35D.
light. The filter delivers consistent performance for
approximately 3 years if periodic maintenance is
Titanium Apatite
performed. This filter is not available with FTKS50B. Photocatalytic
Air-Purifying Filter
For FTKS71H
9 10
Comfortable Airflow Lifestyle Convenience Worry Free
Cooling: the flaps flatten out during operation so that cool air slides off to Pressing the Off timer button automatically selects Night
reach the corner of the room.
Set Mode. This function prevents excessive cooling for
Wide-Angle Louvres your pleasant sleep. Room temperature is raised by 0.5 C
From a corner after 60 minutes for cooling operation.
to the centre
Push again!!
+0.5 C Cooling
Set temp. before When you return, you will
Off timer begins be greeted by an air-
to operate conditioned room. Just
push the HOME LEAVE
button again to return to
The louvres can be adjusted your previous settings.
by hand for FTKS25/35D
Time 60 minutes
and with the wireless
Covers even remote controller for Off timer turns on Off timer stops air conditioner
a spacious room FTKS50B, 50/60G and 71H. Cooling operation: Room temperature is raised by 0.5 C after 60 minutes.
11 12
Function Dictionary Function List
Indoor Unit
Models FTKS FTKS FTKS FTKS
Comfortable Airflow Comfort Control Cleanliness Functions 25/35D 50B 50/60G 71H
DC Inverter
Comfort Airflow Mode Indoor Unit Quiet Operation Titanium Apatite Photocatalytic
This function prevents uncomfortable drafts from blowing Indoor unit operating sound levels are decreased by 2 or Air-Purifying Filter Comfort Airflow Mode
directly on to the body. The flap changes the airflow 3 dB (A) from the Low setting fan speed using the
This filter contains the new photocatalytic material
direction. To prevent drafts, the flap moves upward wireless remote controller.
titanium apatite. While the filter’s micron-level fibres trap Power-Airflow
during operation. See page 8 dust, this photocatalyst adsorbs and decomposes Dual Flaps
See page 11
Comfortable Airflow
bacteria. The filter can be used for up to 3 years with
Outdoor Unit Quiet Operation
proper maintenance. Wide-Angle Louvres
Outdoor unit operating sound levels are decreased by 3 dB
Power-Airflow Dual Flaps (A) from the rated operation sound using the wireless
See page 9
Power-Airflow Dual Flaps can flatten out during cooling remote controller. Vertical Auto-Swing
operation to deliver cool air to the corners of a room. See page 8
Air-Purifying Filter with Photocatalytic (up and down)
See page 11 Deodorising Function Horizontal Auto-Swing
Intelligent Eye This filter is made of titanium oxide. It adsorbs and
(left and right)
Wide-Angle Louvres Intelligent Eye with its infrared sensor automatically
decomposes bacteria. The filter can be used for up to 3
The smoothly curved Wide-Angle Louvres provide wide controls air conditioner operation according to human 3-D Airflow
years with proper maintenance.
airflow coverage for effective operation no matter where movement in a room. When there is no movement, it
the indoor unit is placed in a room. adjusts the temperature by 2 C for energy savings. See page 9 Indoor Unit Quiet
See page 11 See page 7 Operation
Comfort Control
Mould-Proof Operation
Vertical Auto-Swing (up and down) Programme Dry Function Mould-Proof Operation automatically runs fan-only Intelligent Eye
This function automatically moves the flaps up and down operation for 1 hour when cooling or dry operation is
This function automatically reduces the level of humidity.
to distribute air across a room. stopped. This airflow prevents the generation of mould Programme Dry
and mould odours inside the indoor unit. Function
See page 11
See page 10
Auto Fan Speed Auto Fan Speed
Horizontal Auto-Swing (left and right) The microprocessor automatically controls fan speed to Wipe-Clean Flat Panel
Horizontal Auto-Swing automatically moves the louvres adjust the room temperature to the set temperature. The flat panel models can be cleaned with only the single
Lifestyle Convenience
to the left and right to cover a room with cool air. Econo Mode
pass of a cloth across their smooth surface. The flat
See page 11
Timers panel can also be easily removed for more thorough Inverter Powerful
cleaning.
3-D Airflow See page 10
Operation
This function combines Vertical and Horizontal Auto- Home Leave
Swing to circulate a cloud of cool air right to the corners 24-Hour On/Off Timer Operation
of even large spaces. This timer can be preset to start and stop at any time
See page 11 Indoor Unit On/Off
within a 24-hour period. The air conditioner is started/ Switch
stopped simply by pressing the On/Off timer button on
the wireless remote controller. Titanium Apatite
Photocatalytic
Lifestyle Convenience Air-Purifying Filter
Night Set Mode Air-Purifying Filter
Cleanliness
with Photocatalytic
Pressing the Off timer button automatically selects Night Deodorizing Function
Econo Mode Set Mode. This function prevents excessive cooling for Mould-Proof
This mode limits maximum running current to 70% and your pleasant sleep. Room temperature is raised by 0.5 C Operation
power consumption to 50% to 70% of normal operation, after 60 minutes for cooling operation.
while maintaining maximum capacity at 60% to 80%. This See page 11 Wipe-Clean Flat Panel
improves operating efficiency and also prevents circuit
breakers from being overloaded.
24-Hour On/Off Timer
Timers
See page 7
Worry Free
Inverter Powerful Operation Night Set Mode
This function is convenient for boosting cooling performance
Worry Free
for a 20-minute period both when you first turn on your Auto-Restart after
Auto-Restart after Power Failure Power Failure
air conditioner or want to quickly change the room
The air conditioner memorises the settings for mode,
temperature. Self-Diagnosis with
airflow, temperature, etc., and automatically returns to
See page 11 Digital Display
them when power is restored after a power failure.
Home Leave Operation
Home Leave Operation continues operation to prevent a
Self-Diagnosis with Digital Display Outdoor Unit
Malfunction codes are shown on the digital display panel
room from becoming too hot, while you are sleeping or Models RKS RKS RKS RKS
of the wireless remote controller for fast and easy
out of your home. Select any temperature from 18 to 32 C. Functions 25/35G 50B 50/60G 71H
maintenance.
See page 12
Worry Comfort
Free Control
Outdoor Unit
Indoor Unit On/Off Switch Anticorrosion Treatment of Outdoor Quiet Operation
The unit can be conveniently started manually in the Heat Exchanger Fins Anticorrosion Treat-
event the wireless remote controller is misplaced or the ment of Outdoor Heat
The outdoor unit’s heat exchanger fins are processed Exchanger Fins
wireless remote controller batteries are not charged. using a special anticorrosion treatment. The surface is
See page 11 covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
See page 12
13 14
Easy-to-Use Wireless Remote Controller
Wireless remote controller for FTKS25/35D Wireless remote controller for FTKS71H
15 16
Specifications Options
FTKS25/35D
Model name
Indoor unit FTKS25DVM FTKS35DVM Indoor unit
Outdoor unit RKS25GVMG RKS35GVMG No. Item FTKS25/35D FTKS50B FTKS50/60G FTKS71H
kW 2.5 (1.2-3.2) 3.5 (1.4-4.0) 1 5-room centralized controller *1 KRC72
Capacity Rated (Min.-Max.)
Btu/h 8,500 (4,050-10,900) 11,900 (4,750-13,650)
2 Wiring adaptor for time clock/remote controller KRP413AB1S
Power supply 1 phase, 230 V, 50 Hz (Normal open pulse contact/normal open contact) *2
Running current Rated A 3.9 4.8
3 Titanium apatite photocatalytic air-purifying filter *3 KAF970A46 KAF952B42 KAF970A48
Power consumption Rated (Min.-Max.) W 700 (295-1,050) 1,035 (300-1,400)
4 Air-purifying filter with photocatalytic deodorising function *3 KAF952A42
COP Rated W/W 3.57 3.38
5 Remote controller loss prevention with chain KKF917A4 KKF910A4
Indoor unit FTKS25DVM FTKS35DVM
Front panel colour White Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. The time clock and other devices should be obtained locally.
Airflow rate (H) m3/min (cfm) 8.7 (307) 8.9 (314)
*3. The filter is a standard accessory. It should be replaced approximately every 3 years.
Fan speed 5 steps, quiet and automatic
Sound levels (H/L/SL) dB (A) 37/25/22 39/26/23
Dimensions (H x W x D) mm 283 x 800 x 195
Machine weight kg 9
Outdoor unit RKS25GVMG RKS35GVMG Titanium apatite photocatalytic
Titanium apatite photocatalytic Titanium apatite photocatalytic
Casing colour Ivory white air-purifying filter air-purifying filter air-purifying filter
Type Hermetically sealed swing type KAF970A46 KAF952B42 KAF970A48
Compressor
Motor output W 600
Refrigerant charge (R-410A) kg 0.8 1.0
Sound levels (H/L) dB (A) 46/43 47/44
Dimensions (H x W x D) mm 550 x 765 x 285
Machine weight kg 32 34
Operation range CDB 10 to 46
Liquid 6.4
Piping Gas mm 5-room centralised Remote controller loss Remote controller loss
connections 9.5
Drain controller prevention with chain prevention with chain
18.0
Max. piping length KRC72 KKF917A4 KKF910A4
25
m
Max. height difference 15
Outdoor unit
No. Item RKS25/35G RKS50B RKS50/60G RKS71H
1 Air direction adjustment grille KPW937A4 KPW945A4
2 Drain plug KKP937A4 *1 KKP945A4
FTKS50B, 50/60G and 71H Note: *1. One set includes 5 pieces for 5 units.
Indoor unit FTKS50BVMA FTKS50GVMG FTKS60GVMG FTKS71HVMG
Model name
Outdoor unit RKS50BVMG RKS50GVMG RKS60GVMG RKS71HVMG
kW 5.00 (0.90-5.80) 5.0 (1.7-6.0) 6.0 (2.3-6.7) 7.1 (2.3-8.5)
Capacity Rated (Min.-Max.)
Btu/h 17,070 (3,070-19,800) 17,100 (5,800-20,500) 20,500 (7,800-22,900) 24,200 (7,800-29,000)
Power supply 1 phase, 230 V, 50 Hz
Running current Rated A 7.0 6.2 7.8 9.2
Power consumption Rated (Min.-Max.) W 1,660 (450-2,300) 1,400 (440-2,080) 1,780 (570-3,580) 2,100 (570-3,100) Air direction adjustment grille Drain plug Drain plug
KPW945A4 KKP937A4 KKP945A4
COP Rated W/W 3.01 3.57 3.37 3.38
Indoor unit FTKS50BVMA FTKS50GVMG FTKS60GVMG FTKS71HVMG
Front panel colour White
Airflow rate (H) m3/min (cfm) 11.4 (402) 14.7 (519) 17.4 (614) 21.5 (760)
Fan speed 5 steps, quiet and automatic
Sound levels (H/L/SL) dB (A) 44/35/32 43/34/31 46/37/34
Control system
Dimensions (H x W x D) mm 290 x795 x238 290 x 1,050 x 238 340 x 1,200 x 240 No. Item FTKS25/35D FTKS50B FTKS50/60G FTKS71H
Machine weight kg 9 12 17 1 Central remote controller *1 DCS302CA61
Outdoor unit RKS50BVMG RKS50GVMG RKS60GVMG RKS71HVMG 2 Unified On/Off controller *1 DCS301BA61
Casing colour Ivory white 3 Schedule timer *1 DST301BA61
Type Hermetically sealed swing type 4 Interface adaptor for DIII-NET use KRP928BB2S
Compressor
Motor output W 1,500 1,100 1,920 Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
Refrigerant charge (R-410A) kg 1.20 1.5 1.7 2.3
Sound levels (H/L) dB (A) 47/44 54/49 52/49
Dimensions (H x W x D) mm 735 x 825 x 300 770 x 900 x 320
Machine weight kg 48 47 55 71
Operation range CDB 5 to 46 10 to 46
Liquid 6.4 9.5
Piping Gas mm 12.7 15.9
connections Central remote controller Unified On/Off controller Schedule timer
Drain 18.0 DCS302CA61 DCS301BA61 DST301BA61
Max. piping length 30
m
Max. height difference 20
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound levels are based on the temperature conditions 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual
operation as a result of ambient conditions.
17 18