LMS FMS Compact BA 02 0163
LMS FMS Compact BA 02 0163
LMS FMS Compact BA 02 0163
FMS Compact
Fluid Management System
Baby
USER MANUAL
November 2016
LMS_FMS Compact_BA_02_1611
Contents Page
LMS_FMS Compact_BA_02_1611
Basic safety recommendations Page 1/19
Installation
Do not place any unit on an unstable surface that may allow it to fall.
Never place the units above a radiator or heating unit.
Route all cabling away from potential hazards.
Isolate from the mains before removing any covers.
Power connection
Use only the type of power source suitable for electronic equipment. If in doubt, contact your
distributor. Ensure that any power cables are of a sufficiently high current rating.
All units must be earthed to eliminate risk of electric shock.
Failure to properly earth a unit may cause damage to that unit or data stored within it.
Protection class
The device has protection class IP 42 and needs to be protected against dripping water,
water, oils, etc.
Cleaning
Switch off all units and isolate from mains before cleaning.
Clean using a damp cloth. Do not use liquid or aerosol cleaners.
Repair of faults
Disconnect all units from power supply and have it repaired by a qualified service person if
any of the following occurs:
If any power cord or plug is damaged or frayed
If a unit does not operate normally when operating instructions are followed
If a unit exposed to rain/water or if any liquid has been spilled into it
If a unit has been dropped or damaged
If a unit shows a change in performance, indicating a need for service.
RoHs
Our products are RoHs compliant.
Battery disposal
The batteries contained in our products need to be disposed of as per your
local legislation acc. to EU directive 2006/66/EG.
LMS_FMS Compact_BA_02_1611
General description Page 2/19
2. General description
2.1 Technical data
LMS_FMS Compact_BA_02_1611
General description Page 3/19
Alphanumeric keypad
Function keys
Emergency stop
Ticket printer
Cable glands
LMS_FMS Compact_BA_02_1611
General description Page 4/19
2.3 Connections
01 PE 16 Valve 3 - 24VDC/2A
02 N 17 Valve 3 - GND
03 L1 230VAC/50Hz 18 Pulse Input 3 + 3
19 Pulse Input 3 GND
04 Valve 2 -24VDC/2A
05 Valve 2 - GND 20 GND
06 Pulse Input 2 + 2 21 +12VDC RS232 Port for software
07 Pulse Input 2 GND 22 +24VDC or external printer
LMS_FMS Compact_BA_02_1611
Standard dispense procedure Page 5/19
-----------------
MINI
FLUID MGR SYSTEM
v5.14UK 18.11.12
02:42 13.02.08
Enter your 4-digit PIN-No. for the user
E N T E R
1111 (Default user by factory) PIN:
0000
Press key "OK"
Quit <= => OK
02:42 13.02.08
The user name is briefly displayed, the screen automatically
move to the next menu. *** Hello ***
User AAA
Enter your “order number”
02:42 13.02.08
Enter your “Job Number” *****************
ENTER JOB NO.:
Alphanumeric entry, max. 15 digits *****************
FE67338
Confirm with "OK"
Quit <= => OK
Select Product:
Select fluid type on keypad or with arrow keys. Product 1 1
Product 2 2
Confirm with "OK" Product 3 3
Product 4
02:42 13.02.08
Enter the requested quantity in liters.
ENTER Quantity:
Confirm with "OK"
_ L
02:42 13.02.08
The system is now ready to dispense the fluid. Prepare
for
Dispensing
000001.00 L
Quit <= => OK
LMS_FMS Compact_BA_02_1611
Supervisor menu: PIN 8888 (default) Page 6/19
02:42 13.02.08
The display moves on count mode.
Once the fluid has been dispensed, the attached solenoid valve
will close and the internal printer will print a ticket.
000.00
000001.00 L
Quit <= => OK
27.01.08 11:13
Prod. Delivery Fluid delivery can be added to the current stock (tank).
Select Product:
Product 1 1
Select a product and confirm with “OK” Product 2 2
or return with “Quit”. Product 3 3
Product 4
Stock Level:
Enter the delivered quantity and confirm with “OK” Level:
or return with “Quit”. Product 1 1
000841.23L
Delivery:
000000.00L
Quit <= => OK
LMS_FMS Compact_BA_02_1611
Supervisor menu: PIN 8888 (default) Page 7/19
Input new
Enter the new stock (tank) level and confirm with “OK” Stock Level:
or return with “Quit”. Product 1 1
000841.23L
LMS_FMS Compact_BA_02_1611
Installer menu: PIN 9999 (default) Page 8/19
Input new
Enter the new product name and confirm with “OK” Productname:
or return with “Quit”.
Product 1 1
Set Min Stock Defines the minimum stock level (tank level), when system Select Product:
should give a warning message. Product 1 1
Stock Level: Product 2 2
000000.00 L Product 3 3
Product 4
Select a product and confirm with “OK”
or return with “Quit”. Quit <= => OK
Enter the new minimum stock level and confirm with “OK”
or return with “Quit”. Input Minimum
Stock Level:
Product 1 1
Only firmware v4.0 and later:
If the Set MinStock is set to zero, the warning is deactivated.
000050.00 L
1
Enter the new operation mode and confirm with “OK”
-----------------
or return with “Quit”. Operation Mode 1
-----------------
Pre-select 1
Free Dispense 2
See also chapter: 9 Dispense modes Quit <= => OK
Initial Timeout Defines the delay after the PIN n° entry until the valve opens
Dispense to:
and the batch starts.
Product 1 1
Product 2 2
Select a product and confirm with “OK” Product 3 3
or return with “Quit”. Product 4
Hose No.: 1
Enter the new timout and confirm with “OK” -----------------
or return with “Quit”. Timeout: 003
-----------------
in Seconds
from 0-255
See also chapter: 11 Dispense timing Quit <= => OK
LMS_FMS Compact_BA_02_1611
Installer menu: PIN 9999 (default) Page 9/19
Inact. Timeout If the pulse input from the meter stops before the preselected
Dispense to:
quantity has been reached, the system will wait for the defined
time before the batch stops and the valve closes
Product 1 1
(default 12 sec). Product 2 2
Product 3 3
Product 4
Select a product and confirm with “OK”
or return with “Quit”.
Quit <= => OK
Hose No.: 1
Enter the new timout and confirm with “OK” -----------------
or return with “Quit”. Timeout: 012
-----------------
in Seconds
from 0-255
See also chapter: 11 Dispense timing
Quit <= => OK
Hose No.: 1
Enter the calibration factor and confirm with “OK” -----------------
or return with “Quit”. KF: 10000
-----------------
Cal.Constant
0.000001L/Pulse
Quit <= => OK
Print Parameter Will print the current configuration on the specified printer No sub menu.
for each hose
LMS_FMS Compact_BA_02_1611
Installer menu: PIN 9999 (default) Page 10/19
LINKAGE
Enter the hose linkage and confirm with “OK”
or return with “Quit”.
Hose: 1
-----------------
Stock: 1
Inac. Delay Defines how long the pump will keep running once the
Dispense to:
dispense has been completed.
Pump control has to be connected to terminal 25/26.
Product 1 1
Product 2 2
Product 3 3
See also chapter 2.3 and chapter 11 Product 4
Hose: 1
-----------------
Stp.Delay: 002
-----------------
Stop Delay in
Seconds 0-255
Quit <= => OK
LMS_FMS Compact_BA_02_1611
Installer menu: PIN 9999 (default) Page 11/19
Special Mode With Special Mode 0 the system will work as a standard Fluid
Special Mode: 0
Management System.
Mode 1 and 2 are customized dispense scenarios.
-----------------
See chapter 9. Standard 0
Direct Mode 1
Additive Calc 2
Only firmware v5.0 and later
Quit <= => OK
Quantity: 1
(1 … 3)
Quit <= => OK
Product:
Product 1 1
Factor:
100000 (ppm)
LMS_FMS Compact_BA_02_1611
General system reset Page 12/19
Procedure:
Unplug the FMS Compact and press the button 1 and 2.
Keep the buttons pressed and plug in the power supply.
LMS_FMS Compact_BA_02_1611
Printer Page 13/19
7. Printer
Note: Make sure the paper edge is straight before inserting it in the machine.
25.05.11 15:12
H.Mueller
458534
SAE15W40 1
L 000004.52
LMS_FMS Compact_BA_02_1611
Barcode scanner Page 14/19
8. Barcode scanner
The serial port of the FMS Compact can be connected to a barcode scanner. It will work
parallel to the existing keypad. You always have the choice to use the keypad or the
scanner.
Note: If the barcode is activated, the PC software or external printer port cannot be used
anymore.
Connection: RS232, D-Sub 25-pole, 9600 Baud, 8 DataBit, ParityNone, 1 Stop Bit
Barcode sample
End suffix:
Each tranmission from the barcode scanner must be followed by a CR and LF control
signal.
CR = ASCII (13) = Hex (0x0a)
LF = ASCII (10) = Hex (0x0d)
LMS_FMS Compact_BA_02_1611
Dispense modes Page 15/19
9. Dispense modes
9.1 Flow chart - Dispense Mode 0 and 1
Enter PIN
Number:
1111
** Good day **
MR.MUELLER
****************
Job Number Menu Special Mode
**************** Direct mode = 1
1234 System will not ask for the job number
MenuSet Mode
Quantity: Free dispense = 2
No preselection. The dispense starts immediately
3,5 L
Ready Ready
to to
dispense dispense
00003.50 L 04200.00 L
Quit <= => OK Quit <= => OK
The batch will stop when :
LMS_FMS Compact_BA_02_1611
Dispense modes Page 16/19
Customized dispense flow, will calculate a required quantity based on a preconfigured factor.
Dispense will start with the Job Number request, no PIN number entry requested.
System will use the first user as the default user.
Administration Menu
****************
Changes to the Supervisor ** Good day **
Gas Delivery PO#
menu, if the Supervisor PIN Supervisor
****************
123456789012 has been entered.
Dispense to:
Product 1 1
Product 2 2
Product 3 3
Product 4 4
Select Additive
Quit <= => OK
Product 1
Product 2
Delivered Product 3
Quantity of fuel Product 4
Values bigger than <16,000
5000 Gal will be blocked. Quit <= => OK
Product
Quit <= => OK
Product 1
LMS_FMS Compact_BA_02_1611
Warning and status messages Page 17/19
The requested quantity has been higher than specified quantity in the
!INPUT - ERROR !
Menu Max.Dispense - Page 11
Maximum dispense
quantity exeeded
02:42 13.02.08
Dispense has been stopped with "Pulse Time Out".
No pulse are arriving from the meter, the Inactive Timout has been exeeded.
001.34 See also page 9 - Inactive Timeout
00003.50 L
Pulse Timeout
03:25 13.02.08
The minimum tank level has been reached, to be defined in the
!!! WARNING !!!
Menu Set Min Stock - Page 8
S T O C K
E M P T Y
000015.00 L
Quit <= => OK
Dispense Alert
The maximum allowable dispense time has been exeeded, to be defined
Dispense time in Menu Dispense TO - Page 11
exeeded
Pulsating beep tone will start.
PULSE ALERT
An unexpected pulse input arrived while the solenoid valve is closed.
Valve Stuck open
A pulsating beep tone will start.
Press any key to If this problem persist, please ask the service personnel.
clear error A leaking valve could be the cause.
PRESS KEY PRESS Only firmware v5.10 and later and Dispense Mode 2
LMS_FMS Compact_BA_02_1611
Dispense timing Page 18/19
Master Valve or Pump Control will Only one dispense can be done at a
be active if there is an ongoing time. Other meters will be blocked.
Relay closed dispense.
MasterValve or
PumpControl
Connection
Potential free relay
t
Relay closed
LMS_FMS Compact_BA_02_1611
Manufacturer´s declaration / Warranty / DIN ISO certificate page 19/19
13. Warranty
Badger Meter warrants meters and parts manufactured by it and supplied hereunder to
be free from defects in materials and workmanship for a period of 24 months from date
of shipment. If within such period any meters or parts shall be proved to Seller´s
satisfaction to be defective, such meters or parts shall be repaired or replaced at Seller´s
option. Seller´s obligation hereunder shall be limited to such repair and replacement and
shall be conditioned upon Seller´s receiving written notice of any alleged defect within 10
days after its discovery and, at Seller´s option, return of such meters or parts to Seller,
f.o.b. its factory. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS OR IMPLIED WARRANTIES WHATSOEVER INCLUDING BUT
NOT LIMITED TO IMPLIED WARRANTIES (EXCEPT OF TITLE) OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Badger Meter
shall not be liable for any defects attributable to acts or omissions of others after
shipment, nor any consequential, incidental or contigent damage whatsoever.
LMS_FMS Compact_BA_02_1611
Hotline
Tel: +49-7025-9208-0
Fax: +49-7025-9208-15
E-Mail: badger@badgermeter.de
Please contact your supplier for any assistance you may need.
Nürtinger Strasse 76
72639 Neuffen (Germany)
E-Mail: badger@badgermeter.de
www.badgermeter.de