QIAprep Miniprep Handbook


For purification of molecular biology grade DNA

Plasmid Large plasmids (>10 kb) Low-copy plasmids and cosmids Plasmid DNA prepared by other methods

W W W. Q I A G E N . C O M

Trademarks: QIAGEN, QIAprep, BioRobot, R.E.A.L., TurboFilter (QIAGEN); DH5 (Invitrogen); pBluescript (Stratagene); pGEM (Promega Corp.); Beckman (Beckman Instruments, Inc); Finntip, Multistepper (Thermo Electron Oy Corporation); Impact (Matrix Technologies Corporation, USA); Minifuge (Heraeus Instruments GmbH). 20022006 QIAGEN, all rights reserved.

Contents
Kit Contents Storage Quality Control Product Use Limitations Product Warranty and Satisfaction Guarantee Technical Assistance Safety Information Introduction Principle Using LyseBlue reagent Important Notes Guidelines for QIAvac manifolds Protocols Plasmid DNA Purification Using the QIAprep Spin Miniprep Kit and a microcentrifuge and 5 ml collection tubes and a vacuum manifold Plasmid DNA Purification Using the QIAprep 8 Miniprep Kit Plasmid DNA Purification Using the QIAprep 8 Turbo Miniprep Kit Plasmid DNA Purification Using the QIAprep 96 Turbo Miniprep Kit Troubleshooting Guide Appendix A: Background Information Growth of bacterial cultures Preparation of cell lysates Appendix B: Agarose Gel Analysis of Plasmid DNA Appendix C: Special Applications Purification of low-copy plasmids and cosmids Purification of plasmid DNA prepared by other methods References Ordering Information QIAGEN Distributors and Importers 22 23 24 28 31 33 36 39 39 42 43 44 44 44 45 46 51 4 7 7 7 7 8 9 10 11 14 15 18

QIAprep Miniprep Handbook 12/2006

Kit Contents
QIAprep Spin Miniprep Kit Catalog no. QIAprep Spin Columns Buffer P1 Buffer P2 Buffer N3* Buffer PB* Buffer PE (concentrate) Buffer EB LyseBlue RNase A

(50) 27104 50 20 ml 20 ml 30 ml 30 ml 2 x 6 ml 15 ml 20 l 200 l 50 1 (50) 27144 50 140 ml 140 ml 250 ml 500 ml 2 x 100 ml 2 x 55 ml 140 l 55 x 8 55 x 8 55 x 8 1

(250) 27106 250 73 ml 73 ml 140 ml 150 ml 55 ml 55 ml 73 l 730 l 250 1

Collection Tubes (2 ml) Handbook QIAprep 8 Miniprep Kit Catalog no. QIAprep 8 Strips Buffer P1 Buffer P2 Buffer N3* Buffer PB* Buffer PE (concentrate) Buffer EB RNase A Collection Microtubes (1.2 ml) Caps for QIAprep Strips Caps for Collection Microtubes Handbook

* Buffers N3 and PB contain chaotropic salts which are irritants and not compatible with disinfecting agents containing bleach. Take appropriate laboratory safety measures and wear gloves when handling. See page 9 for further information.

Provided as a 10 mg/ml solution. Provided as a 100 mg/ml solution.

QIAprep Miniprep Handbook 12/2006

QIAprep 8 Turbo Miniprep Kit Catalog no. TurboFilter 8 Strips QIAprep 8 Strips Buffer P1 Buffer P2 Buffer N3* Buffer PB* Buffer PE (concentrate) Buffer EB RNase A Collection Microtubes (1.2 ml) Caps for QIAprep Strips Caps for Collection Microtubes Handbook

(10) 27152 10 10 40 ml 40 ml 60 ml 100 ml 2 x 20 ml 55 ml 400 l 13 x 8 13 x 8 13 x 8 1

(50) 27154 50 50 125 ml 125 ml 2 x 125 ml 500 ml 2 x 100 ml 2 x 55 ml 125 l 55 x 8 55 x 8 55 x 8 1

* Buffers N3 and PB contain chaotropic salts which are irritants and not compatible with disinfecting agents containing bleach. Take appropriate laboratory safety measures and wear gloves when handling. See page 9 for further information.

Provided as a 10 mg/ml solution. Provided as a 100 mg/ml solution.

QIAprep Miniprep Handbook 12/2006

QIAprep 96 Turbo Miniprep Kit Catalog no. TurboFilter 96 Plates QIAprep 96 Plates Buffer P1 Buffer P2 Buffer N3* Buffer PB* Buffer PE (concentrate) Buffer EB RNase A Tape Pads Rack of Collection Microtubes (1.2 ml) Caps for Collection Microtubes Flat-Bottom Blocks and Lids Handbook

(4) 27191 4 4 125 ml 125 ml 2 x 80 ml 500 ml 2 x 100 ml 2 x 55 ml 1 x 125 l 1 4 55 x 8 4 1

(24) 27193 24 24 1 x 700 ml, 1 x 125 ml 1 x 700 ml, 1 x 125 ml 1 x 1000 ml, 1 x 80 ml 6 x 500 ml 5 x 200 ml, 2 x 100 ml 1 x 55 ml, 2 x 250 ml 1 x 125 l, 1 x 700 l 6 24 6 x 55 x 8 24 1

* Buffers N3 and PB contain chaotropic salts which are irritants and not compatible with disinfecting agents containing bleach. Take appropriate laboratory safety measures and wear gloves when handling. See page 9 for further information.

Provided as a 100 mg/ml solution.

QIAprep Miniprep Handbook 12/2006

Storage
QIAprep Miniprep Kits should be stored dry at room temperature (1525C). Kits can be stored for up to 12 months without showing any reduction in performance and quality. For longer storage these kits can be kept at 28C. If any precipitate forms in the buffers after storage at 28C it should be redissolved by warming the buffers to 37C before use. After addition of RNase A and optional LyseBlue reagent, Buffer P1 is stable for 6 months when stored at 28C. RNase A stock solution can be stored for two years at room temperature.

Quality Control
In accordance with QIAGENs ISO-certified Total Quality Management System, each lot of QIAprep Miniprep Kit is tested against predetermined specifications to ensure consistent product quality.

Product Use Limitations


QIAprep Miniprep Kits are developed, designed, and sold for research purposes only. They are not to be used for human diagnostic or drug purposes or to be administered to humans unless expressly cleared for that purpose by the Food and Drug Administration in the USA or the appropriate regulatory authorities in the country of use. All due care and attention should be exercised in the handling of many of the materials described in this text. The QIAcube, BioRobot 3000, BioRobot 8000 and BioRobot Universal System workstations are intended for research applications. No claim or representation is intended for their use to provide information for the diagnosis, prevention, or treatment of a disease.

Product Warranty and Satisfaction Guarantee


QIAGEN guarantees the performance of all products in the manner described in our product literature. The purchaser must determine the suitability of the product for its particular use. Should any product fail to perform satisfactorily due to any reason other than misuse, QIAGEN will replace it free of charge or refund the purchase price. We reserve the right to change, alter, or modify any product to enhance its performance and design. If a QIAGEN product does not meet your expectations, simply call your local Technical Service Department. We will credit your account or exchange the product as you wish. A copy of QIAGEN terms and conditions can be obtained on request, and is also provided on the back of our invoices. If you have questions about product specifications or performance, please call QIAGEN Technical Services or your local distributor (see back cover).
QIAprep Miniprep Handbook 12/2006 7

Technical Assistance
At QIAGEN we pride ourselves on the quality and availability of our technical support. Our Technical Service Departments are staffed by experienced scientists with extensive practical and theoretical expertise in molecular biology and the use of QIAGEN products. If you have any questions or experience any difficulties regarding QIAprep Miniprep Kits, or QIAGEN products in general, please do not hesitate to contact us. QIAGEN customers are a major source of information regarding advanced or specialized uses of our products. This information is helpful to other scientists as well as to the researchers at QIAGEN. We therefore encourage you to contact us if you have any suggestions about product performance or new applications and techniques. For technical assistance and more information please call one of the QIAGEN Technical Service Departments or local distributors (see back cover). Comprehensive background information on plasmid preparation procedures and common plasmid applications in addition to kit selection guides, frequently asked questions, and information about our purification technologies can be found on our plasmid Web page www.qiagen.com/goto/plasmidinfo .

QIAprep Miniprep Handbook 12/2006

Safety Information
When working with chemicals, always wear a suitable lab coat, disposable gloves, and protective goggles. For more information, please consult the appropriate material safety data sheets (MSDSs). These are available online in convenient and compact PDF format at www.qiagen.com/ts/msds.asp where you can find, view, and print the MSDS for each QIAGEN kit and kit component. CAUTION: DO NOT add bleach or acidic solutions directly to the sample-preparation waste. Buffers N3 and PB contain guanidine hydrochloride, which can form highly reactive compounds when combined with bleach. If liquid containing these buffers is spilt, clean with suitable laboratory detergent and water. If the spilt liquid contains potentially infectious agents, clean the affected area first with laboratory detergent and water, and then with 1% (v/v) sodium hypochlorite. The following risk and safety phrases apply to QIAprep Miniprep Kits. Buffer N3 Contains guanidine hydrochloride, acetic acid: harmful, irritant. Risk and safety phrases:* R22-36/38, S13-23-26-36/37/39-46. Buffer P2 Contains sodium hydroxide: irritant. Risk and safety phrases:* R36/38, S13-26-36-46. Buffer PB Contains guanidine hydrochloride, isopropanol: harmful, flammable, irritant. Risk and safety phrases:* R10-22-36/38, S13-23-26-36/37/39-46 RNase A Contains ribonuclease: sensitizer. Risk and safety phrases:* R42/43, S23-24-2636/37. 24-hour emergency information Emergency medical information in English, French, and German can be obtained 24 hours a day from: Poison Information Center Mainz, Germany Tel: +49-6131-19240

* R10: Flammable; R22: Harmful if swallowed; R36/38: Irritating to eyes and skin; R42/43: May cause sensitization by inhalation and skin contact; S13: Keep away from food, drink, and animal feedingstuffs; S23; Do not breathe spray; S24: Avoid contact with skin; S26: In case of contact with eyes, rinse immediately with plenty of water and seek medical advice; S36: Wear suitable protective clothing; S36/37: Wear suitable protecting clothing and gloves; S36/37/39: Wear suitable protective clothing, gloves and eye/face protection; S46: If swallowed seek medical advice immediately and show the container or label.

QIAprep Miniprep Handbook 12/2006

Introduction
The QIAprep Miniprep system provides a fast, simple, and cost-effective plasmid miniprep method for routine molecular biology laboratory applications. QIAprep Miniprep Kits use silica membrane technology to eliminate the cumbersome steps associated with loose resins or slurries. Plasmid DNA purified with QIAprep Miniprep Kits is immediately ready for use. Phenol extraction and ethanol precipitation are not required, and high-quality plasmid DNA is eluted in a small volume of Tris buffer (included in each kit) or water. The QIAprep system consists of four products with different handling options to suit every throughput need. Low throughput The QIAprep Spin Miniprep Kit is designed for quick and convenient processing of 124 samples simultaneously in less than 30 minutes. QIAprep spin columns can be used in a microcentrifuge or on any vacuum manifold with luer connectors (e.g., QIAvac 24 Plus, or QIAvac 6S with QIAvac Luer Adapters). The QIAprep Spin Miniprep Kit can be fully automated on the QIAcube. The innovative QIAcube uses advanced technology to process QIAGEN spin columns, enabling seamless integration of automated, low-throughput sample prep into your laboratory workflow. Sample preparation using the QIAcube follows the same steps as the manual procedure (i.e., lyse, bind, wash, and elute) enabling you to continue using the QIAprep Spin Miniprep Kit for purification of high-quality plasmid DNA. The QIAcube is preinstalled with protocols for purification of plasmid DNA, genomic DNA, RNA, viral nucleic acids, and proteins, plus DNA and RNA cleanup. The range of protocols available is continually expanding, and additional QIAGEN protocols can be downloaded free of charge at www.qiagen.com/MyQIAcube . Medium throughput For medium throughput requirements the QIAprep 8 Miniprep Kit and QIAprep 8 Turbo Miniprep Kit utilize 8-well strips on QIAvac 6S allowing up to 48 minipreps to be performed simultaneously in approximately 40 and 30 minutes respectively. In addition, the QIAprep 8 Turbo BioRobot Kit enables automated purification of up to 48 minipreps in 50 minutes on BioRobot systems. High throughput The QIAprep 96 Turbo Miniprep Kit enables up to 96 minipreps to be performed simultaneously in less than 45 minutes on the QIAvac 96. For automated high-throughput plasmid purification the QIAprep 96 Turbo BioRobot Kit enables up to 96 minipreps to be processed in 70 minutes.

10

QIAprep Miniprep Handbook 12/2006

Applications using QIAprep purified DNA Plasmid DNA prepared using the QIAprep system is suitable for a variety of routine applications including:

Restriction enzyme digestion Library screening In vitro translation

Sequencing Ligation and transformation Transfection of robust cells

Principle
The QIAprep miniprep procedure is based on alkaline lysis of bacterial cells followed by adsorption of DNA onto silica in the presence of high salt (1). The unique silica membrane used in QIAprep Miniprep Kits completely replaces glass or silica slurries for plasmid minipreps. The procedure consists of three basic steps:

Preparation and clearing of a bacterial lysate Adsorption of DNA onto the QIAprep membrane Washing and elution of plasmid DNA

All steps are performed without the use of phenol, chloroform, CsCl, ethidium bromide, and without alcohol precipitation. Preparation and clearing of bacterial lysate The QIAprep miniprep procedure uses the modified alkaline lysis method of Birnboim and Doly (2). Bacteria are lysed under alkaline conditions, and the lysate is subsequently neutralized and adjusted to high-salt binding conditions in one step. After lysate clearing, the sample is ready for purification on the QIAprep silica membrane. For more details on growth of bacterial cultures and alkaline lysis, please refer to Appendix A on pages 3942. In the QIAprep Spin and QIAprep 8 miniprep procedures, lysates are cleared by centrifugation, while the QIAprep 8 and 96 Turbo Miniprep kits provide TurboFilter strips or plates for lysate clearing by filtration. LyseBlue reagent * Use of LyseBlue is optional and is not required to successfully perform plasmid preparations. See Using LyseBlue reagent on page 14 for more information.

* LyseBlue reagent is only supplied with QIAprep Spin Miniprep Kits since multiwell or automated formats do not allow visual control of individual samples.

QIAprep Miniprep Handbook 12/2006

11

LyseBlue is a color indicator which provides visual identification of optimum buffer mixing. This prevents common handling errors that lead to inefficient cell lysis and incomplete precipitation of SDS, genomic DNA, and cell debris. This makes LyseBlue ideal for use by researchers who have not had much experience with plasmid preparations as well as experienced scientists who want to be assured of maximum product yield. DNA adsorption to the QIAprep membrane QIAprep columns, strips, and plates use a silica membrane for selective adsorption of plasmid DNA in high-salt buffer and elution in low-salt buffer. The optimized buffers in the lysis procedure, combined with the unique silica membrane, ensure that only DNA will be adsorbed, while RNA, cellular proteins, and metabolites are not retained on the membrane but are found in the flow-through. Washing and elution of plasmid DNA Endonucleases are efficiently removed by a brief wash step with Buffer PB. This step is essential when working with endA+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, to ensure that plasmid DNA is not degraded. The Buffer PB wash step is also necessary when purifying low-copy plasmids, where large culture volumes are used. Salts are efficiently removed by a brief wash step with Buffer PE. High-quality plasmid DNA is then eluted from the QIAprep column with 50100 l of Buffer EB or water. The purified DNA is ready for immediate use in a range of applications no need to precipitate, concentrate, or desalt. Note: Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water for elution, make sure that the pH value is within this range. Store DNA at 20C when eluted with water since DNA may degrade in the absence of a buffering agent. DNA yield Plasmid yield with the QIAprep miniprep system varies depending on plasmid copy number per cell (see page 39), the individual insert in a plasmid, factors that affect growth of the bacterial culture (see pages 3942), the elution volume (Figure 1), and the elution incubation time (Figure 2). A 1.5 ml overnight culture can yield from 5 to 15 g of plasmid DNA (Table 1, page 14). To obtain the optimum combination of DNA quality, yield, and concentration, we recommend using Luria-Bertani (LB) medium for growth of cultures (for composition see page 41), eluting plasmid DNA in a volume of 50 l, and performing a short incubation after addition of the elution buffer.

12

QIAprep Miniprep Handbook 12/2006

Elution Volume versus DNA Concentration and Recovery QIAprep Spin

Figure 1 10 g pUC18 DNA was purified using the QIAprep Spin protocol and eluted with the indicated volumes of Buffer EB. The standard protocol uses 50 l Buffer EB for elution, since this combines high yield with high concentration. However the yield can be increased by increasing the elution volume.

Incubation Time versus DNA Recovery


100

80 Recovery (%)

60

100 l 50 l

40

20

0 1 2 3 4 5 Incubation time (min) 10 30

Figure 2 10 g pBluescript DNA was purified using the QIAprep Spin Miniprep protocol and eluted after the indicated incubation times with either 50 l or 100 l Buffer EB. The graph shows that an incubation time of 1 minute and doubling the elution buffer volume increases yield.

QIAprep Miniprep Handbook 12/2006

13

Table 1. Effect of Different Compositions of Growth Medium LB on DNA Yield Culture media LB (containing 10 g/liter NaCl) LB (containing 5 g/liter NaCl) Yield 11.5 g 9.5 g

QIAprep Spin Miniprep Kit was used to purify DNA from 1.5 ml LB overnight cultures of XL1-Blue containing pBluescript . Elution was performed according to the standard protocol (50 l Buffer EB and 1 min incubation). Use of the recommended LB composition (with 10 g/liter NaCl, also see Appendix A, p. 43) provides optimal plasmid yield.

Using LyseBlue reagent


Using a simple visual identification system, LyseBlue reagent prevents common handling errors that lead to inefficient cell lysis and incomplete precipitation of SDS, cell debris, and genomic DNA. LyseBlue can be added to the resuspension buffer (Buffer P1) bottle before use. Alternatively, smaller amounts of LyseBlue can be added to aliquots of Buffer P1, enabling single plasmid preparations incorporating visual lysis control to be performed. LyseBlue reagent should be added to Buffer P1 at a ratio of 1:1000 to achieve the required working concentration (e.g., 10 l LyseBlue into 10 ml Buffer P1). Make sufficient LyseBlue/Buffer P1 working solution for the number of plasmid preps being performed. LyseBlue precipitates after addition into Buffer P1. This precipitate will completely dissolve after addition of Buffer P2. Shake Buffer P1 before use to resuspend LyseBlue particles. The plasmid preparation procedure is performed as usual. After addition of Buffer P2 to Buffer P1, the color of the suspension changes to blue. Mixing should result in a homogeneously colored suspension. If the suspension contains localized regions of colorless solution or if brownish cell clumps are still visible, continue mixing the solution until a homogeneously colored suspension is achieved. Upon addition of neutralization buffer (Buffer N3), LyseBlue turns colorless. The presence of a homogeneous solution with no traces of blue indicates that SDS from the lysis buffer has been effectively precipitated.

14

QIAprep Miniprep Handbook 12/2006

Important Notes
Please read the following notes before starting any of the QIAprep procedures. Growth of bacterial cultures in tubes or flasks 1. Pick a single colony from a freshly streaked selective plate and inoculate a culture of 15 ml LB medium containing the appropriate selective antibiotic. Incubate for 1216 h at 37C with vigorous shaking. Growth for more than 16 h is not recommended since cells begin to lyse and plasmid yields may be reduced. Use a tube or flask with a volume of at least 4 times the volume of the culture. 2. Harvest the bacterial cells by centrifugation at > 8000 rpm (6800 x g ) in a conventional, table-top microcentrifuge for 3 min at room temperature (1525C). The bacterial cells can also be harvested in 15 ml centrifuge tubes at 5400 x g for 10 min at 4C. Remove all traces of supernatant by inverting the open centrifuge tube until all medium has been drained. Cell Cultivation in a 96-Well Block for QIAprep Turbo 96 1. Fill each well of a 96-well flat-bottom block with 1.3 ml of growth medium containing the appropriate selective agent. Inoculate each well from a single bacterial colony. Incubate the cultures for 2024 h at 37C with vigorous shaking. The wells in the block may be protected against spill-over by covering the block with a plastic lid or adhesive tape. AirPore microporous tape sheets promote gas exchange during culturing (see ordering information, page 49). If non-porous tape is used, pierce 23 holes in the tape with a needle above each well for aeration. 2. Harvest the bacterial cells in the block by centrifugation for 5 min at 2100 x g in a centrifuge with a rotor for microtiter plates (e.g., QIAGEN Centrifuge 4K15C, or Heraeus Minifuge GL), preferably at 410C. The block should be covered with adhesive tape during centrifugation. Remove media by inverting the block. To remove the media, peel off the tape and quickly invert the block over a waste container. Tap the inverted block firmly on a paper towel to remove any remaining droplets of medium. WARNING: Ensure that the buckets on the rotor have sufficient clearance to accommodate the 2 ml flat-bottom blocks before starting the centrifuge.

QIAprep Miniprep Handbook 12/2006

15

Buffer notes

Add the provided RNase A solution to Buffer P1, mix, and store at 28C. Add ethanol (96100%) to Buffer PE before use (see bottle label for volume). Check Buffers P2 and N3 before use for salt precipitation. Redissolve any precipitate by warming to 37C. Do not shake Buffer P2 vigorously. Close the bottle containing Buffer P2 immediately after use to avoid acidification of Buffer P2 from CO2 in the air. Buffers P2, N3, and PB contain irritants. Wear gloves when handling these buffers. Optional: Add the provided LyseBlue reagent to Buffer P1 and mix before use. Use one vial LyseBlue (spin down briefly before use) per bottle of Buffer P1 to achieve a 1:1000 dilution. LyseBlue provides visual identification of optimum buffer mixing thereby preventing the common handling errors that lead to inefficient cell lysis and incomplete precipitation of SDS, genomic DNA, and cell debris. For more details see Using LyseBlue reagent on page 14. All centrifugation steps are carried out at 13,000 rpm (~17,900 x g) in a conventional, table-top microcentrifuge. Switch off vacuum between steps to ensure that a consistent, even vacuum is applied during manipulations. Wear safety glasses when working near a manifold under pressure. For safety reasons, do not use 96-well plates that have been damaged in any way. For QIAprep 8, QIAprep 8 Turbo, and QIAprep 96 Turbo miniprep procedures, the negative pressure (vacuum) should be regulated before beginning the procedure by applying the vacuum to the appropriate number of empty QIAprep modules (indicated in Table 2) on the QIAvac manifold. The vacuum pressure is the pressure differential between the inside of the manifold and the atmosphere (standard atmospheric pressure: 1013 millibar or 760 mm Hg) and can be measured using a vacuum regulator (see ordering information, page 48). Vacuum recommendations are given in negative units (Table 2) to indicate the required reduction in pressure with respect to the atmosphere. Table 3 provides pressure conversions to other units.

Centrifugation notes

Vacuum notes

Use of a vacuum pressure lower than recommended may reduce DNA yield and purity.

16

QIAprep Miniprep Handbook 12/2006

Table 2. Regulation of Vacuum Pressures for QIAprep Multiwell Procedures Procedure QIAprep 8 QIAprep 8 Turbo Vacuum manifold QIAvac 6S QIAvac 6S Module used for checking pressure* QIAprep 8 strip(s)

Vacuum pressure mbar mm Hg 75 to 400 75 to 400 30 to 150 100 to 530 40 to 200

QIAprep 8 strip(s) 100 to 530

QIAprep 96 Turbo QIAvac 96 QIAprep 96 plate


* Pressure should be regulated using empty modules on the manifold.

Regulate the vacuum using the number of 8-well strips that will be used in the purification. Values apply to empty modules on QIAvac. During the working procedure the vacuum may exceed the values indicated.

Table 3. Pressure Conversions To convert from millibars (mbar) to Millimeters of mercury (mm Hg) Kilopascals (kPa) Inches of mercury (inch Hg) Torrs (Torr) Atmospheres (atm) Pounds per square inch (psi) Elution notes Multiply by: 0.75 0.1 0.0295 0.75 0.000987 0.0145

Ensure that the elution buffer is dispensed directly onto the center of the QIAprep membrane for optimal elution of DNA. Average eluate volume is 48 l from an elution-buffer volume of 50 l (QIAprep spin procedures), and 60 l from an elution-buffer volume of 100 l (QIAprep multiwell procedures). For increased DNA yield, use a higher elution-buffer volume. For increased DNA concentration, use a lower elution-buffer volume (see DNA yield, pages 1314). If water is used for elution, make sure that its pH is between 7.0 and 8.5. Elution efficiency is dependent on pH and the maximum elution efficiency is achieved within this range. A pH <7.0 can decrease yield. Note: Store DNA at 20C when eluted with water, as DNA may degrade in the absence of a buffering agent.

DNA can also be eluted in TE buffer (10 mM TrisCl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.

QIAprep Miniprep Handbook 12/2006

17

Multichannel pipet recommendations Many steps of the QIAprep 8 procedure and the QIAprep 8 and 96 Turbo procedures require repeated pipetting, and a reservoir or multichannel pipet can greatly facilitate liquid handling. The Matrix Impact cordless multichannel pipet can be purchased with an optional expandable tip-spacing system for direct liquid transfer from tubes to microtiter plates. These can be purchased from Matrix Technologies Corporation: www.matrixtechcorp.com . Pipet tip recommendations Some standard 1 ml pipet tips are not easily accommodated in the flat-bottom blocks that are used in the QIAprep 96 Turbo Miniprep protocol. When pipetting into flat-bottom blocks, we recommend using pipet tips with 1.25 ml or 1.5 ml fill volume, such as:

Matrix pipet tips (cat. no. 8051) for use with the Matrix pipet mentioned above. These can be purchased from the supplier listed above. Finntip Multistepper pipet tips for use with single-channel pipets. These are available from Thermo Electron Corporation: www.thermo.com .

Guidelines for QIAvac manifolds


QIAvac 24 Plus, QIAvac 6S, and QIAvac 96 facilitate DNA minipreps by providing a convenient modular vacuum manifold for use with the QIAprep system. The following recommendations should be followed when handling QIAvac manifolds.

QIAvac manifolds operate with a house vacuum or Vacuum Pump (e.g., Vacuum Pump, cat. no. 84010 [USA and Canada], 84000 [Japan], or 84020 [rest of world]). Always store QIAvac manifolds clean and dry. To clean, simply rinse all components with water and dry with paper towels. Do not air dry, as the screws may rust and need to be replaced. Do not use abrasives or solvents. Always place the QIAvac manifold on a secure bench top or work area. If dropped, the manifold may crack. The components of QIAvac manifolds are not resistant to ethanol, methanol, or other organic solvents (Table 4). Do not bring solvents into contact with the vacuum manifold. If solvents are spilled on the unit, rinse thoroughly with distilled water. Ensure that no residual Buffer PE remains in the vacuum manifold.

18

QIAprep Miniprep Handbook 12/2006

To ensure consistent performance, do not apply silicone or vacuum grease to any part of a QIAvac manifold. The spring lock on the top plate and the self-sealing gasket (QIAvac 6S and QIAvac 96) provide an airtight seal when vacuum is applied to the assembled unit. To maximize gasket lifetime, rinse the gasket free of salts and buffers after each use and dry with paper towels before storage.

Table 4. Chemical-Resistance Properties of QIAvac Manifolds Resistant to: Chlorine bleach (12%) Hydrochloric acid Sodium chloride Sodium hydroxide Urea Acetone Chromic acid* Phenol Concentrated alcohols* Not resistant to: Acetic acid* Benzene Chloroform Ethers Toluene

* QIAvac 24 Plus is resistant to these chemicals.

QIAvac vacuum manifolds QIAvac 24 Plus Manifold

2
7 6 5 4 3 2 1

2 1
8 10 9

12 11

24 23 21 20 19 18 17 16 15

E QIAG

22

14 13

1
Figure 3 Components of the QIAvac 24 Plus manifold. 1. QIAvac 24 Plus vacuum manifold 2. Luer slot closed with luer plug 3. Spin column

QIAprep Miniprep Handbook 12/2006

19

QIAvac 6S Manifold
9 8 10
6

6 3 2 5

Figure 4 Components of the QIAvac 6S manifold. 1. QIAvac base, which holds a waste tray, a strip holder, or a microtube rack 2. Waste tray 3. QIAvac strip holder to hold 8-well strips 4. QIAvac top plate with slots for 8-well strips or QIAvac Luer Adapters 5. Microtube rack 6. 8-well strip* 7. Blanks to seal unused slots 8. QIAvac Luer Adapter 9. QIAprep spin column* 10. Plug to seal unused luer connectors

QIAvac 96 Manifold
6

6 3 5

Figure 5 Components of the QIAvac 96 manifold. 1. QIAvac base, which holds a waste tray, a plate holder, or a microtube rack 2. Waste tray 3. Plate holder (shown with 96-well plate) 4. QIAvac 96 top plate with aperture for 96-well plate 5. Microtube rack 6. 96-well plate

* Not included with QIAvac 6S. Included in appropriate kits. Not included with QIAvac 6S. Must be purchased separately. Not included with QIAvac 96. Included in QIAprep 96 Turbo Miniprep Kits.

20

QIAprep Miniprep Handbook 12/2006

QIAprep Spin Procedure in microcentrifuges on vacuum manifolds


Pelleted bacteria

Resuspend Lyse Neutralize

Bind

Bind

Vacuum

Wash

Wash

Vacuum

Elute

Elute

Pure plasmid DNA

Pure plasmid DNA

QIAprep Miniprep Handbook 12/2006

21

QIAprep Spin

Protocol: Plasmid DNA Purification Using the QIAprep Spin Miniprep Kit and a Microcentrifuge
This protocol is designed for purification of up to 20 g of high-copy plasmid DNA from 15 ml overnight cultures of E. coli in LB (Luria-Bertani) medium. For purification of low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods, refer to the recommendations on page 44. Please read Important Notes on pages 1521 before starting. Note: All protocol steps should be carried out at room temperature. Procedure 1. Resuspend pelleted bacterial cells in 250 l Buffer P1 and transfer to a microcentrifuge tube. Ensure that RNase A has been added to Buffer P1. No cell clumps should be visible after resuspension of the pellet. If LyseBlue reagent has been added to Buffer P1, vigorously shake the buffer bottle to ensure LyseBlue particles are completely dissolved. The bacteria should be resuspended completely by vortexing or pipetting up and down until no cell clumps remain. 2. Add 250 l Buffer P2 and mix thoroughly by inverting the tube 46 times. Mix gently by inverting the tube. Do not vortex, as this will result in shearing of genomic DNA. If necessary, continue inverting the tube until the solution becomes viscous and slightly clear. Do not allow the lysis reaction to proceed for more than 5 min. If LyseBlue has been added to Buffer P1 the cell suspension will turn blue after addition of Buffer P2. Mixing should result in a homogeneously colored suspension. If the suspension contains localized colorless regions or if brownish cell clumps are still visible, continue mixing the solution until a homogeneously colored suspension is achieved. 3. Add 350 l Buffer N3 and mix immediately and thoroughly by inverting the tube 46 times. To avoid localized precipitation, mix the solution thoroughly, immediately after addition of Buffer N3. Large culture volumes (e.g. 5 ml) may require inverting up to 10 times. The solution should become cloudy. If LyseBlue reagent has been used, the suspension should be mixed until all trace of blue has gone and the suspension is colorless. A homogeneous colorless suspension indicates that the SDS has been effectively precipitated. 4. Centrifuge for 10 min at 13,000 rpm (~17,900 x g) in a table-top microcentrifuge. A compact white pellet will form.
22 QIAprep Miniprep Handbook 12/2006

5. 6. 7.

Apply the supernatants from step 4 to the QIAprep spin column by decanting or pipetting. Centrifuge for 3060 s. Discard the flow-through. Recommended: Wash the QIAprep spin column by adding 0.5 ml Buffer PB and centrifuging for 3060 s. Discard the flow-through. This step is necessary to remove trace nuclease activity when using endA+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, which have high levels of nuclease activity or high carbohydrate content. Host strains such as XL-1 Blue and DH5 do not require this additional wash step.

QIAprep Spin

8. 9.

Wash QIAprep spin column by adding 0.75 ml Buffer PE and centrifuging for 3060 s. Discard the flow-through, and centrifuge for an additional 1 min to remove residual wash buffer. Important: Residual wash buffer will not be completely removed unless the flow-through is discarded before this additional centrifugation. Residual ethanol from Buffer PE may inhibit subsequent enzymatic reactions.

10. Place the QIAprep column in a clean 1.5 ml microcentrifuge tube. To elute DNA, add 50 l Buffer EB (10 mM TrisCl, pH 8.5) or water to the center of each QIAprep spin column, let stand for 1 min, and centrifuge for 1 min.

Protocol: Plasmid DNA Purification Using the QIAprep Spin Miniprep Kit and 5 ml Collection Tubes
The QIAprep Spin Miniprep procedure can be performed using 5 ml centrifuge tubes (e.g., Greiner, cat. no. 115101 or 115261) as collection tubes to decrease handling. The standard protocol on pages 2223 should be followed with the following modifications: Step 4: Place a QIAprep spin column in a 5 ml centrifuge tube instead of a 2 ml collection tube. Step 6: Centrifuge at 3000 x g for 1 min using a suitable rotor (e.g., Beckman GS-6KR centrifuge at ~4000 rpm). (The flow-through does not need to be discarded.) Steps 7 For washing steps, centrifugation should be performed at 3000 x g for 1 min. and 8: (The flow-through does not need to be discarded.) Step 9: Transfer the QIAprep spin column to a microcentrifuge tube. Centrifuge at maximum speed for 1 min. Continue with step 10 of the protocol.

QIAprep Miniprep Handbook 12/2006

23

QIAprep Spin

Protocol: Plasmid DNA Purification Using the QIAprep Spin Miniprep Kit and a Vacuum Manifold
This protocol is designed for purification of up to 20 g high-copy plasmid DNA from 15 ml overnight cultures of E. coli grown in LB (Luria-Bertani) medium, using QIAprep spin columns on QIAvac 24 Plus, QIAvac 6S, or other vacuum manifolds with luer connectors. For purification of low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods, refer to the recommendations on page 44. Please read Important Notes on pages 1521 before starting. Note: All protocol steps should be carried out at room temperature. Procedure 1. Resuspend pelleted bacterial cells in 250 l Buffer P1 and transfer to a microcentrifuge tube. Ensure that RNase A has been added to Buffer P1. No cell clumps should be visible after resuspension of the pellet. If LyseBlue reagent has been added to Buffer P1, vigorously shake the buffer bottle to ensure LyseBlue particles are completely dissolved. The bacteria should be resuspended completely by vortexing or pipetting up and down until no cell clumps remain. 2. Add 250 l Buffer P2 and mix thoroughly by inverting the tube gently 46 times. Do not vortex, as this will result in shearing of genomic DNA. If necessary, continue inverting the tube until the solution becomes viscous and slightly clear. Do not allow the lysis reaction to proceed for more than 5 min. If LyseBlue has been added to Buffer P1 the cell suspension will turn blue after addition of Buffer P2. Mixing should result in a homogeneously colored suspension. If the suspension contains localized colorless regions or if brownish cell clumps are still visible, continue mixing the solution until a homogeneously colored suspension is achieved. 3. Add 350 l Buffer N3 and mix immediately and thoroughly by inverting the tube 46 times. To avoid localized precipitation, immediately after addition of Buffer N3 mix the solution gently but thoroughly. Large culture volumes (e.g. 5 ml) may require inverting up to 10 times. The solution should become cloudy. If LyseBlue reagent has been used, the suspension should be mixed until all trace of blue has gone and the suspension is colorless. A homogeneous colorless suspension indicates that the SDS has been effectively precipitated. 4. Centrifuge for 10 min at 13,000 rpm (~17,900 x g) in a table-top microcentrifuge. A compact white pellet will form.
24 QIAprep Miniprep Handbook 12/2006

During centrifugation, prepare the vacuum manifold and QIAprep spin columns: QIAvac 24 Plus (see pages 16 and 1819):

Ensure that the vacuum source is connected to the upper threaded hole of the
QIAvac 24 Plus and the lower threaded hole is tightly sealed using the screw cap.

QIAprep Spin

If using the QIAvac Connecting System, connect the system to the manifold
and vacuum soured as described in the QIAvac 24 Plus Handbook.

Insert up to 24 spin columns into the luer slots of the QIAvac 24 Plus. Close
unused luer slots with luer plugs. QIAvac 6S manifold: (Note: The following procedure applies to the manifold with a hinged lid and spring lock. See pages 16 and 1820.)

Open QIAvac 6S lid. Place QIAvac luer adapter(s), or blanks (provided with
QIAvac 6S) to seal unused slots, into the slots of the QIAvac top plate. Close the QIAvac 6S lid. Place the waste tray inside the QIAvac base, and place the top plate squarely over the base. Attach the QIAvac 6S to a vacuum source.

Insert each QIAprep spin column into a luer connector on the luer adapter(s)
in the vacuum manifold. Seal unused luer connectors with plugs provided with the QIAvac Luer Adapter Set. Other vacuum manifolds: Follow the suppliers instructions. Insert each QIAprep column into a luer connector. 5. 6. 7. Apply the supernatant from step 4 to the QIAprep spin column by decanting or pipetting. Switch on vacuum source to draw the solution through the QIAprep spin columns, and then switch off vacuum source. Recommended: Wash the QIAprep spin column by adding 0.5 ml Buffer PB. Switch on vacuum source. After the solution has moved through the column, switch off vacuum source. This step is necessary to remove trace nuclease activity when using endA+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, which have high levels of nuclease activity or high carbohydrate content. Host strains such as XL-1 Blue and DH5 do not require this additional wash step. 8. Wash the QIAprep spin column by adding 0.75 ml Buffer PE. Switch on vacuum source to draw the wash solution through the column, and then switch off vacuum source.

QIAprep Miniprep Handbook 12/2006

25

9.

Transfer the QIAprep spin columns to a microcentrifuge tube. Centrifuge for 1 min. Important: This extra spin is necessary to remove residual Buffer PE. Residual ethanol from Buffer PE may inhibit subsequent enzymatic reactions.

QIAprep Spin

10. Place the QIAprep column in a clean 1.5 ml microcentrifuge tube. To elute DNA, add 50 l Buffer EB (10 mM TrisCl, pH 8.5) or water to the center of the QIAprep spin column, let stand for 1 min, and centrifuge for 1 min.

26

QIAprep Miniprep Handbook 12/2006

QIAprep 8 Procedure
Pelleted bacteria

QIAprep Spin

Resuspend Lyse Neutralize

Bind

Vacuum

Wash

Vacuum

Elute

Vacuum

Pure plasmid DNA

QIAprep Miniprep Handbook 12/2006

27

Protocol: Plasmid DNA Purification Using the QIAprep 8 Miniprep Kit


This protocol is designed for purification of high-copy plasmid DNA from up to 48 samples in parallel. Up to 20 g DNA can be purified from 15 ml cultures of E. coli grown in LB (Luria-Bertani) medium. For purification of low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods, refer to the recommendations on page 44.

QIAprep 8

Please read Important Notes for QIAprep Procedures on pages 1521 before starting. Note: All protocol steps should be carried out at room temperature. Procedure 1. Resuspend pelleted bacterial cells in 250 l Buffer P1 and transfer to a microcentrifuge tube. Ensure that RNase A has been added to Buffer P1. No cell clumps should be visible after resuspension of the pellet. 2. Add 250 l Buffer P2 and mix thoroughly by gently inverting the tube 46 times. Mix gently by inverting the tube. Do not vortex, as this will result in shearing of genomic DNA. If necessary, continue inverting the tube until the solution becomes viscous and slightly clear. Do not allow lysis reaction to proceed for more than 5 min. 3. Add 350 l Buffer N3 and mix immediately and thoroughly by inverting the tube 46 times. To avoid localized precipitation, mix the solution gently but thoroughly, immediately after addition of Buffer N3. The solution should become cloudy. 4. Centrifuge for 10 min at 13,000 rpm (~17,900 x g) in a table-top microcentrifuge. A compact white pellet will form. During centrifugation, prepare QIAvac 6S: (Note: The following procedure applies to the manifold with a hinged lid and spring lock. See pages 16 and 1820).

Open the QIAvac 6S lid and place QIAprep 8 strips in the slots of the QIAvac
top plate, making sure the strips are positioned tightly. Seal any unused slots with blanks provided with the QIAvac 6S, and close the QIAvac 6S lid.

Place the waste tray inside the QIAvac base. Place the top plate squarely over
the base. Seal any unused wells of the QIAprep strips with strip caps provided. Attach the QIAvac 6S to a vacuum source. 5. Apply the supernatants from step 4 to the wells of the QIAprep 8 strips and switch on vacuum source.

28

QIAprep Miniprep Handbook 12/2006

Make sure the QIAvac 6S is assembled correctly before loading. Load the supernatants promptly onto the QIAprep 8 strips. If the supernatants become cloudy, centrifuge again immediately before loading to prevent clogging the QIAprep 8 strips. The flow-through is collected in the waste tray. 6. Recommended: Switch off vacuum and wash QIAprep 8 strips by adding 1 ml Buffer PB to each well and applying vacuum. This step is recommended to remove trace nuclease activity when using endA+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, which have high levels of nuclease activity or high carbohydrate content. Host strains such as XL-1 Blue and DH5 do not require this additional step. 7. Switch off vacuum. Wash QIAprep 8 strips by adding 1 ml Buffer PE to each well and applying vacuum. Allow Buffer PE to flow through the QIAprep 8 strips. 8. 9. Repeat step 7. After Buffer PE has been drawn through all wells, apply maximum vacuum for an additional 5 min to dry the membrane. Important: This step removes residual Buffer PE from the membrane. The removal is only effective when maximum vacuum is used (i.e., turn off vacuum regulator or leakage valves if they are used), allowing maximum airflow to go through the wells. 10. Switch off the vacuum source and ventilate the QIAvac manifold. Lift the top plate from the base (not the QIAprep strips from the top plate), vigorously tap the top plate on a stack of absorbent paper until no drops come out, and blot the nozzles of the QIAprep strips with clean absorbent paper. Proceed to step 11a or 11b. This step removes residual Buffer PE, which may be present around the outlet nozzles and collars of the QIAprep 8 strips. Residual ethanol from Buffer PE may inhibit subsequent enzymatic reactions. 11a. For elution into collection microtubes provided: Replace waste tray with the blue collection microtube rack (provided with the QIAvac 6S) containing 1.2 ml collection microtubes. Place the top plate back on the base. Rows of collection microtubes should be lined up with the QIAprep 8 strips. 11b. For elution into a 96-well microplate: Replace waste tray with empty blue collection microtube rack (provided with QIAvac 6S) and place a 96-well microplate directly on the rack. Place the top plate back on the base. 12. Elute DNA by adding 100 l Buffer EB (10 mM TrisCl, pH 8.5) or water to the center of each well of the QIAprep 8 Strips, let stand for 1 min, and switch on vacuum source. After elution, switch off vacuum source and ventilate the QIAvac 6S slowly. For increased DNA concentration, an elution volume of 75 l can be used.
QIAprep Miniprep Handbook 12/2006 29

QIAprep 8

QIAprep 8 and 96 Turbo Procedure


Pelleted bacteria

Resuspend Lyse Neutralize

TurboFilter

QIAprep 8 Turbo

Filter

Vacuum QIAprep

Bind

Vacuum

Wash

Vacuum

Elute

Vacuum

Pure plasmid DNA

30

QIAprep Miniprep Handbook 12/2006

Protocol: Plasmid DNA Purification Using the QIAprep 8 Turbo Miniprep Kit
This protocol is designed for medium-throughput plasmid DNA minipreps using TurboFilter 8 and QIAprep 8 strips on QIAvac 6S. The kit accommodates 848 parallel preparations of up to 20 g of high-copy plasmid DNA from 15 ml overnight cultures of E. coli grown in LB (Luria-Bertani) medium. For purification of low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods, refer to the recommendations on page 44. DNA purification can be automated, please call QIAGEN for more details. Please read Important Notes on pages 1521 before starting. Note: All protocol steps should be carried out at room temperature.

QIAprep 8 Turbo

Procedure 1. Resuspend pelleted bacterial cells in 250 l Buffer P1. Ensure that RNase A has been added to Buffer P1. No cell clumps should be visible after resuspension of the pellet. 2. Add 250 l Buffer P2 to each sample, mix thoroughly by gently inverting the tubes 46 times, and incubate at room temperature for 5 min. It is important to mix gently by inverting the tubes. Do not vortex, as this will result in shearing of genomic DNA. If necessary, continue inverting the tubes until the solution becomes viscous and slightly clear. During incubation prepare the QIAvac 6S (see pages 16 and 1820):

Open QIAvac 6S lid and place TurboFilter 8 Strips in the slots of the QIAvac
top plate. Make sure the strips are positioned tightly. Seal any unused slots with blanks (provided with QIAvac 6S), and close QIAvac 6S lid.

Place the strip holder inside the QIAvac base. Place QIAprep 8 strips into the
strip holder such that a QIAprep strip is placed under each TurboFilter strip.

Place the top plate squarely over the base. Seal any unused wells of the
TurboFilter strips with the strip caps provided. Attach the QIAvac to vacuum source. 3. Add 350 l Buffer N3 to each sample and mix immediately and thoroughly by inverting the tubes 46 times. To avoid localized precipitation, mix the samples gently but thoroughly, immediately after addition of Buffer N3. The solutions should become cloudy. 4. Pipet the lysates from step 3 (850 l per well) into the wells of the TurboFilter strips. Unused wells of TurboFilter strips should be sealed with the strip caps provided. Apply vacuum until all samples have passed through TurboFilter. Optimal flow rate is 12 drops/s, which can be regulated by using a 3-way valve or vacuum regulator (see page 48) between the QIAvac and the vacuum source.
QIAprep Miniprep Handbook 12/2006 31

5.

Switch off vacuum, and ventilate the QIAvac 6S slowly. Discard the TurboFilter strips. Transfer the QIAprep strips containing the cleared lysates into the slots of the QIAvac top plate. Close QIAvac 6S lid. Replace strip holder in the base with the waste tray. Place the top plate squarely over the base. Seal any unused wells of the QIAprep strips with the strip caps provided. Apply vacuum. The flow-through is collected in the waste tray. Recommended: Switch off vacuum, and wash QIAprep strips by adding 1 ml Buffer PB to each well and applying vacuum. This step is necessary to remove trace nuclease activity when using endA+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, which have high levels of nuclease activity or high carbohydrate content. Host strains such as XL-1 Blue and DH5 do not require this additional step.

6.

QIAprep 8 Turbo

7. 8.

Switch off vacuum. Wash QIAprep strips by adding 1 ml Buffer PE to each well and applying vacuum. Repeat once. After Buffer PE has been drawn through all wells, apply maximum vacuum for an additional 5 min to dry the membrane. Important: This step removes residual Buffer PE from the membrane. The removal is only effective when maximum vacuum is used (i.e., turn off vacuum regulator or leakage valves if they are used), allowing maximum airflow to go through the wells.

9.

Switch off vacuum, and ventilate the QIAvac 6S slowly. Lift the top plate from the base (not the QIAprep strips from the top plate), vigorously tap the top plate on a stack of absorbent paper until no drops come out, and blot the nozzles of the QIAprep strips with clean absorbent paper. Proceed either to step 10a or 10b, as desired. This step removes residual Buffer PE, which may be present around the outlet nozzles and collars of QIAprep strips. Residual ethanol from Buffer PE may inhibit subsequent enzymatic reactions.

10a. For elution into collection microtubes provided: Replace waste tray with the blue collection microtube rack (provided with the QIAvac 6S) containing 1.2 ml collection microtubes. Place the top plate back on the base. Rows of collection microtubes should be lined up with the QIAprep 8 strips. 10b. For elution into a 96-well microplate: Replace waste tray with empty blue collection microtube rack (provided with the QIAvac 6S) and place a 96-well microplate directly on the rack. Place the top plate back on the base. 11. To elute DNA, add 100 l Buffer EB (10 mM TrisCl, pH 8.5) or water to the center of each well of the QIAprep strips, let stand 1 min, and apply maximum vacuum for 5 min. Switch off vacuum and ventilate the QIAvac 6S slowly. For increased DNA concentration, an elution volume of 75 l can be used.
32 QIAprep Miniprep Handbook 12/2006

Protocol: Plasmid DNA Purification Using the QIAprep 96 Turbo Miniprep Kit
This protocol is designed for high-throughput plasmid DNA minipreps using TurboFilter 96 and QIAprep 96 plates on QIAvac 96. The kit accommodates up to 96 parallel preparations of up to 20 g of high-copy plasmid DNA from 15 ml overnight cultures of E. coli grown in LB (Luria-Bertani) medium. If 1.3 ml overnight cultures are used, up to 96 cultures can be grown in a flat-bottom block (see page 15 for protocol). For purification of low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods, refer to the recommendations on page 44. DNA purification can be automated, please call QIAGEN for more details. Please read Important Notes on pages 1521 before starting. Note: All protocol steps should be carried out at room temperature. Procedure 1. Resuspend pelleted bacterial cells in 250 l Buffer P1 and transfer to the flatbottom block (if cells were not harvested in this block) provided with the kit.

QIAprep 96 Turbo

Ensure that RNase A has been added to Buffer P1. No cell clumps should be visible after resuspension of the pellet. 2. Add 250 l Buffer P2 to each sample. Dry the top of the flat-bottom block with a paper towel, seal the block with the tape provided, gently invert the block 46 times to mix, and incubate at room temperature for 5 min. It is important to mix gently by inverting the block. Do not shake vigorously, as this will result in shearing of genomic DNA. If necessary, continue inverting the block until the solution becomes viscous and slightly clear. During incubation prepare QIAvac 96 (see pages 16 and 1820):

Place the TurboFilter 96 plate in the QIAvac top plate, make sure that the plate
is seated securely. Seal unused wells of the TurboFilter with tape.

Place the plate holder inside the QIAvac base. Place QIAprep 96 plate into
the plate holder.

Place QIAvac 96 top plate squarely over base. The QIAprep plate should now
be positioned under the TurboFilter plate. Attach QIAvac to a vacuum source. 3. Remove the tape from the block. Add 350 l Buffer N3 to each sample, dry the top of the flat-bottom block with a paper towel, and seal the block with a new tape sheet. Gently invert the block 46 times. To avoid localized precipitation, mix the samples gently but thoroughly, immediately after addition of Buffer N3. The solutions should become cloudy.

QIAprep Miniprep Handbook 12/2006

33

4.

Remove the tape from the block. Pipet the lysates from step 3 (850 l per well) into the wells of the TurboFilter plate. Unused wells of the TurboFilter plate should be sealed with tape. Apply vacuum until all samples have passed through. The optimal flow rate is approximately 12 drops/s, which can be regulated by using a 3-way valve or vacuum regulator (see page 48) between the QIAvac and the vacuum source.

5.

Switch off vacuum and ventilate the QIAvac 96 slowly. Discard the TurboFilter plate. Transfer the QIAprep plate containing the cleared lysates to the top plate of the manifold. Seal any unused wells of the QIAprep plate with tape. Replace plate holder in the base with waste tray. Place the top plate squarely over the base, making sure that the QIAprep plate is seated securely. Apply vacuum. The flow-through is collected in the waste tray. Recommended: Switch off vacuum, and wash QIAprep plate by adding 0.9 ml Buffer PB to each well and applying vacuum. This step is necessary to remove trace nuclease activity when using endA+ strains such as the JM series, HB101 and its derivatives, or any wild-type strain, which have high levels of nuclease activity or high carbohydrate content. Host strains such as XL-1 Blue and DH5 do not require this additional step.

6.

QIAprep 96 Turbo

7. 8.

Switch off vacuum. Wash QIAprep plate by adding 0.9 ml of Buffer PE to each well and applying vacuum. Repeat once. After Buffer PE has been drawn through all wells, apply maximum vacuum for an additional 10 min to dry the membrane. Important: This step removes residual Buffer PE from the membrane. The removal is only effective when maximum vacuum is used (i.e., turn off vacuum regulator or leakage valves if they are used), allowing maximum airflow to go through the wells.

9.

Switch off vacuum, and ventilate the QIAvac 96 slowly. Lift the top plate from the base (not the QIAprep plate from the top plate), vigorously tap the top plate on a stack of absorbent paper until no drops come out, and blot the nozzles of the QIAprep plate with clean absorbent paper. Proceed either to step 10a, or 10b, as desired. This step removes residual Buffer PE, which may be present around the outlet nozzles and collars of QIAprep plate. Residual ethanol from Buffer PE may inhibit subsequent enzymatic reactions.

34

QIAprep Miniprep Handbook 12/2006

10a. For elution into provided collection microtubes: Replace waste tray with the blue collection microtube rack containing 1.2 ml collection microtubes. Place the top plate back on the base, making sure that the QIAprep plate is seated securely. 10b. For elution into a 96-well microplate: Replace waste tray with an empty blue collection microtube rack (provided with the QIAvac 96). Place a 96-well microplate directly on the rack. Place the top plate back on the base, making sure that the QIAprep plate is positioned securely. 11. To elute DNA, add 100 l of Buffer EB (10 mM TrisCl, pH 8.5) or water to the center of each well of the QIAprep plate, let stand for 1 min, and apply maximum vacuum for 5 min. Switch off vacuum and ventilate QIAvac 96 slowly. For increased DNA concentration, an elution volume of 75 l can be used.

QIAprep 96 Turbo
35

QIAprep Miniprep Handbook 12/2006

Troubleshooting Guide
This troubleshooting guide may be helpful in solving any problems that may arise. The scientists in QIAGEN Technical Services are always happy to answer any questions you may have about either the information and protocol(s) in this handbook or molecular biology applications (see back cover for contact information). Comments and suggestions Low or no yield General Low yields may be caused by a number of factors. To find the source of the problem, analyze fractions saved from each step in the procedure on an agarose gel (e.g., Figure 6, page 43). A small amount of the cleared lysate and the entire flow-through can be precipitated by adding 0.7 volumes isopropanol and centrifuging at maximum speed (13,000 rpm or ~17,000 x g) for 30 minutes. The entire wash flow-through can be precipitated by adding 0.1 volumes of 3 M sodium acetate, pH 5.0, and 0.7 volumes of isopropanol.

No DNA in the cleared lysate before loading a) b) c) d) Plasmid did not propagate Lysate prepared incorrectly Buffer P2 precipitated Cell resuspension incomplete Read Growth of bacterial cultures (pages 3941) and check that the conditions for optimal growth were met. Check storage conditions and age of buffers. Redissolve by warming to 37C. Pelleted cells should be completely resuspended in Buffer P1. Do not add Buffer P2 until an even suspension is obtained.

DNA is found in the flow-through of cleared lysate a) QIAprep membrane overloaded If rich culture media, such as TB or 2x YT are used, culture volumes must be reduced. It may be necessary to adjust LB culture volume if the plasmid and host strain show extremely high copy number or growth rates. See Culture media on page 41.

36

QIAprep Miniprep Handbook 12/2006

Comments and suggestions b) c) RNase A digestion omitted RNase A digestion insufficient Ensure that RNase A is added to Buffer P1 before use. Reduce culture volume if necessary. If Buffer P1 containing RNase A is more than 6 months old, add additional RNase A.

DNA is found in the wash flow-through Ethanol omitted from wash buffer Little or no DNA in eluate a) Elution buffer incorrect DNA is eluted only in the presence of low-salt buffer (e.g., Buffer EB [10 mM TrisCl, pH 8.5] or water). Elution efficiency is dependent on pH. The maximum efficiency is achieved between pH 7.0 and 8.5. When using water for elution, make sure that the pH value is within this range. Repeat procedure with correctly prepared wash buffer (Buffer PE).

b)

Elution buffer incorrectly Add elution buffer to the center of the QIAprep dispensed onto membrane to ensure that the buffer completely covers membrane the surface of the membrane for maximum elution efficiency.

Low DNA quality DNA does not perform well in downstream applications a) Eluate salt concentration For the QIAprep spin column, modify the wash step by too high incubating the column for 5 minutes at room temperature after adding 0.75 ml of Buffer PE and then centrifuging. For QIAprep 8 preparations and QIAprep 8 and 96 Turbo preparations, ensure that two wash steps are carried out prior to elution. Nuclease contamination When using endA+ host strains such as HB101 and its derivatives, the JM series, or any wild-type strain, ensure that the wash step with Buffer PB is performed. Eluate contains residual ethanol Ensure that step 9 in the QIAprep Spin Miniprep protocol and steps 9 and 10 in the QIAprep 8 Miniprep, QIAprep 8 Turbo Miniprep, or QIAprep 96 Turbo Miniprep protocols are performed.

b)

c)

QIAprep Miniprep Handbook 12/2006

37

Comments and suggestions RNA in the eluate a) b) RNase A digestion omitted RNase A digestion insufficient Ensure that RNase A is added to Buffer P1 before use. Reduce culture volume if necessary. If Buffer P1 containing RNase A is more than 6 months old, add additional RNase A.

Genomic DNA in the eluate a) Buffer P2 added incorrectly Buffer N3 added incorrectly Lysis too long Culture overgrown The lysate must be handled gently after addition of Buffer P2 to prevent shearing. Reduce culture volume if lysate is too viscous for gentle mixing. Upon addition of Buffer N3 in step 3, mix immediately but gently. Lysis in step 2 must not exceed 5 minutes. Overgrown cultures contain lysed cells and degraded DNA. Do not grow cultures for longer than 1216 hours.

b) c) d)

38

QIAprep Miniprep Handbook 12/2006

Appendix A: Background Information


Growth of bacterial cultures
Plasmids are generally prepared from bacterial cultures grown in the presence of a selective agent such as an antibiotic (3,4). The yield and quality of plasmid DNA may depend on factors such as plasmid copy number, host strain, inoculation, antibiotic, and type of culture medium. Plasmid copy number Plasmids vary widely in their copy number per cell (Table 5), depending on their origin of replication (e.g., pMB1, ColE1, or pSC101) which determines whether they are under relaxed or stringent control; and depending on the size of the plasmid and its associated insert. Some plasmids, such as the pUC series and derivatives, have mutations which allow them to reach very high copy numbers within the bacterial cell. Plasmids based on pBR322 and cosmids are generally present in lower copy numbers. Very large plasmids and cosmids are often maintained at very low copy numbers per cell. Table 5. Origins of replication and copy numbers of various plasmids (3). Origin of replication pMB1* ColE1 pMB1* pMB1* pMB1* p15A pSC101 ColE1 ColE1

DNA construct Plasmids pUC vectors pBluescript vectors pGEM vectors

Copy number 500700 300500 300400 >1000 1520 1012 ~5 1020 1020

Classification high copy high copy high copy high copy low copy low copy very low copy low copy low copy

pTZ vectors pBR322 and derivatives pACYC and derivatives pSC101 and derivatives Cosmids SuperCos pWE15

* The pMB1 origin of replication is closely related to that of ColE1 and falls in the same incompatibility group. The high-copy-number plasmids listed here contain mutated versions of this origin.

QIAprep Miniprep Handbook 12/2006

39

Host strains Most E. coli strains can be used successfully to isolate plasmid DNA, although the strain used to propagate a plasmid has an effect on the quality of the purified DNA. Host strains such as DH1, DH5, and C600 give high-quality DNA. The slower growing strain XL1-Blue also yields DNA of very high-quality which works extremely well for sequencing. Strain HB101 and its derivatives, such as TG1 and the JM series, produce large amounts of carbohydrates, which are released during lysis and can inhibit enzyme activities if not completely removed (4). In addition, these strains have high levels of endonuclease activity which can reduce DNA quality. The methylation and growth characteristics of the strain should also be taken into account when selecting a host strain. XL1-Blue and DH5 are highly recommended for reproducible and reliable results. Inoculation Bacterial cultures for plasmid preparation should always be grown from a single colony picked from a freshly streaked selective plate. Subculturing directly from glycerol stocks, agar stabs, and liquid cultures may lead to uneven plasmid yield or loss of the plasmid. Inoculation from plates that have been stored for a long time may also lead to loss or mutation of the plasmid. The desired clone should be streaked from a glycerol stock onto a freshly prepared agar plate containing the appropriate selective agent so that single colonies can be isolated. This procedure should then be repeated to ensure that a single colony of an antibioticresistant clone can be picked. A single colony should be inoculated into 15 ml of media containing the appropriate selective agent, and grown with vigorous shaking for 1216 hours. Growth for more than 16 hours is not recommended since cells begin to lyse and plasmid yields may be reduced. Antibiotics Antibiotic selection should be applied at all stages of growth. Many plasmids in use today do not contain the par locus which ensures that the plasmids segregate equally during cell division. Daughter cells that do not receive plasmids will replicate much faster than plasmid-containing cells in the absence of selective pressure, and can quickly take over the culture. The stability of the selective agent should also be taken into account. Resistance to ampicillin, for example, is mediated by -lactamase which is encoded by the plasmidlinked bla gene and which hydrolyzes ampicillin. Levels of ampicillin in the culture medium are thus continually depleted. This phenomenon is clearly demonstrated on ampicillin plates, where satellite colonies appear as the ampicillin is hydrolyzed in the vicinity of a growing colony. Ampicillin is also very sensitive to temperature, and when in solution should be stored frozen in single-use aliquots. The recommendations given in Table 6 are based on these considerations.

40

QIAprep Miniprep Handbook 12/2006

Table 6. Concentrations of Commonly Used Antibiotics Stock solutions Concentration Storage 50 mg/ml in water 34 mg/ml in ethanol 10 mg/ml in water 10 mg/ml in water 5 mg/ml in ethanol 20C 20C 20C 20C 20C Working concentration (dilution) 100 g/ml (1/500) 170 g/ml (1/200) 50 g/ml (1/200) 50 g/ml (1/200) 50 g/ml (1/100)

Antibiotic Ampicillin (sodium salt) Chloramphenicol Kanamycin Streptomycin Tetracycline HCl Culture media

Luria-Bertani (LB) broth is the recommended culture medium for use with QIAprep Kits, since richer broths such as TB (Terrific Broth) or 2x YT lead to extremely high cell densities, which can overload the purification system. It should be noted that cultures grown in TB may yield 25 times the number of cells compared to cultures grown in LB broth. If these media are used, recommended culture volumes must be reduced to match the capacity of the QIAprep membrane. If excess culture volume is used, alkaline lysis will be inefficient, the QIAprep membrane will be overloaded, and the performance of the system will be unsatisfactory. Furthermore, the excessive viscosity of the lysate will require vigorous mixing, which may result in shearing of bacterial genomic DNA and contamination of the plasmid DNA. Care must also be taken if strains are used which grow unusually fast or to very high cell densities. In such cases, doubling the volumes of Buffers P1, P2, and N3 may be beneficial. It is best to calculate culture cell density and adjust the volume accordingly. Please note that a number of slightly different LB culture broths, containing different concentrations of NaCl, are in common use. Although different LB broths produce similar cell densities after overnight culture, plasmid yields can vary significantly.

Table 7. Recommended composition of Luria Bertani medium Contents Tryptone Yeast extract NaCl Per liter 10 g 5g 10 g

QIAprep Miniprep Handbook 12/2006

41

Preparation of cell lysates


Bacteria are lysed under alkaline conditions. After harvesting and resuspension, the bacterial cells are lysed in NaOH/SDS (Buffer P2) in the presence of RNase A (2, 5). SDS solubilizes the phospholipid and protein components of the cell membrane, leading to lysis and release of the cell contents while the alkaline conditions denature the chromosomal and plasmid DNAs, as well as proteins. The optimized lysis time allows maximum release of plasmid DNA without release of chromosomal DNA, while minimizing the exposure of the plasmid to denaturing conditions. Long exposure to alkaline conditions may cause the plasmid to become irreversibly denatured (2). This denatured form of the plasmid runs faster on agarose gels and is resistant to restriction enzyme digestion. The lysate is neutralized and adjusted to high-salt binding conditions in one step by the addition of Buffer N3. The high salt concentration causes denatured proteins, chromosomal DNA, cellular debris, and SDS to precipitate, while the smaller plasmid DNA renatures correctly and stays in solution. It is important that the solution is thoroughly and gently mixed to ensure complete precipitation. To prevent contamination of plasmid DNA with chromosomal DNA, vigorous stirring and vortexing must be avoided during lysis. Separation of plasmid from chromosomal DNA is based on coprecipitation of the cell wall-bound chromosomal DNA with insoluble complexes containing salt, detergent, and protein. Plasmid DNA remains in the clear supernatant. Vigorous treatment during the lysis procedure will shear the bacterial chromosome, leaving free chromosomal DNA fragments in the supernatant. Since chromosomal fragments are chemically indistinguishable from plasmid DNA under the conditions used, the two species will not be separated on QIAprep membrane and will elute under the same low-salt conditions. Mixing during the lysis procedure must therefore be carried out by slow, gentle inversion of the tube.

42

QIAprep Miniprep Handbook 12/2006

Appendix B: Agarose Gel Analysis of Plasmid DNA


The QIAprep Miniprep procedure can be analyzed using agarose gel electrophoresis as shown in Figure 6. Samples can be taken from the cleared lysate and its flow-through, precipitated with isopropanol and resuspended in a minimal volume of TE buffer. In Figure 6 the cleared lysate shows closed circular plasmid DNA and degraded RNase A-resistant RNA. The flow-through contains only degraded RNA and no plasmid DNA is present. The eluted pure plasmid DNA shows no contamination with other nucleic acids. Agarose Gel Analysis
M C F E M

Figure 6 Agarose gel analysis of the QIAprep Miniprep procedure. C: cleared lysate; F: flow-through; E: eluted plasmid; M: markers.

QIAprep Miniprep Handbook 12/2006

43

Appendix C: Special Applications


Purification of low-copy plasmids and cosmids
All QIAprep miniprep protocols in this handbook can be used for preparation of lowcopy-number plasmid or cosmids from 110 ml overnight E. coli cultures grown in LB medium. Only two slight modifications to the protocols are required:

The wash step with Buffer PB is required for all strains. When plasmid or cosmids are >10 kb, pre-heat Buffer EB (or water) to 70C prior to eluting DNA from the QIAprep membrane. A 10 ml overnight LB culture typically yields 510 g DNA.

Note: When using 10 ml culture volume, it is recommended to double the volumes of Buffers P1, P2, and N3 used. Purification of very large plasmids (>50 kb) Plasmids >50 kb elute less efficiently from silica than smaller plasmids, but do elute efficiently from QIAGEN anion-exchange resin. QIAGEN provides the anion-exchangebased QIAGEN Large-Construct Kit for efficient large-scale purification of ultrapure genomic DNA-free BAC, PAC, P1, or cosmid DNA. For high-throughput, small-scale purification of BACs, PACs, and P1s, an optimized alkaline lysis protocol in R.E.A.L. Prep 96 Kits yields DNA suitable for sequencing and screening. Call QIAGEN Technical Services or your local distributor for more information on these kits, or see ordering information on page 47.

Purification of plasmid DNA prepared by other methods


Plasmid DNA isolated by other methods can be further purified using QIAprep modules and any of the QIAprep protocols in this handbook. 1. 2. Add 5 volumes of Buffer PB to 1 volume of the DNA solution and mix (e.g., add 500 l Buffer PB to 100 l of DNA sample). Apply the samples to QIAprep spin columns or to the wells of a QIAprep 8 strip or 96-well plate. Draw the samples through the QIAprep membrane by centrifugation or vacuum, and continue the appropriate protocol at the Buffer PE wash step. The optional wash step with Buffer PB is not necessary.

44

QIAprep Miniprep Handbook 12/2006

References
1. 2. 3. 4. 5. Vogelstein, B., and Gillespie, D. (1979) Preparative and analytical purification of DNA from agarose. Proc. Natl. Acad. Sci. USA 76, 615619. Birnboim, H.C., and Doly, J. (1979) A rapid alkaline lysis procedure for screening recombinant plasmid DNA. Nucleic Acids Res. 7, 15131522. Sambrook, J. et al., eds. (1989) Molecular cloning: a laboratory manual. 2nd ed., Cold Spring Harbor Laboratory Press. Ausubel, F.M. et al., eds. (1991) Current protocols in molecular biology. Wiley Interscience, New York. Birnboim, H.C. (1983) A rapid alkaline extraction method for the isolation of plasmid DNA. Methods Enzymol. 100, 243255.

QIAprep Miniprep Handbook 12/2006

45

Ordering Information
Product QIAprep Spin Miniprep Kit (50) QIAprep Spin Miniprep Kit (250) QIAprep 8 Miniprep Kit (50)* QIAprep 8 Turbo Miniprep Kit (10)* Contents For 50 plasmid minipreps: 50 QIAprep Spin Columns, Reagents, Buffers, Collection Tubes (2 ml) For 250 plasmid minipreps: 250 QIAprep Spin Columns, Reagents, Buffers, Collection Tubes (2 ml) For 50 x 8 plasmid minipreps: 50 QIAprep 8 Strips, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps For 10 x 8 plasmid minipreps: 10 TurboFilter 8 Strips, 10 QIAprep 8 Strips, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps For 50 x 8 plasmid minipreps: 50 TurboFilter 8 Strips, 50 QIAprep 8 Strips, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps For 48 x 8 plasmid minipreps, 48 each: TurboFilter 8 and QIAprep 8 Strips, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps, 96-Well Microplates RB and Lids For 4 x 96 plasmid minipreps: 4 TurboFilter 96 Plates, 4 QIAprep 96 Plates, 4 Flat-Bottom Blocks with Lids, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps For 24 x 96 Plasmid minipreps: 24 x TurboFilter 96 Plates, 24 x QIAprep 96 Plates, 24 Flat-Bottom Blocks with Lids, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps Cat. no. 27104

27106

27144

27152

QIAprep 8 Turbo Miniprep Kit (50)*

27154

QIAprep 8 Turbo BioRobot Kit (48)

962134

QIAprep 96 Turbo Miniprep Kit (4)

27191

QIAprep 96 Turbo Miniprep Kit (24)

27193

* Requires the use of QIAvac 6S. Requires the use of QIAvac 96.

46

QIAprep Miniprep Handbook 12/2006

Ordering Information
Product QIAprep 96 Turbo BioRobot Kit (4) Contents Cat. no. For 4 x 96 plasmid minipreps, 962141 4 each: TurboFilter 96 and QIAprep 96 Plates, Flat-Bottom Blocks and Lids, Reagents, Buffers, Collection Microtubes (1.2 ml), Caps, 96-Well Microplates RB and Lids, Tape Pads

DirectPrep 96 Kits for high-throughput plasmid DNA purification DirectPrep 96 Miniprep Kit (4)* For 4 x 96 plasmid Minipreps: 4 DirectPrep 96 Plates, Reagents, Buffers, Flat-Bottom Blocks and Lids, Air Pore Tape Sheets, Tape Pads, Elution Microtubes RS, Caps For 4 x 96 plasmid Minipreps: 4 DirectPrep 96 Plates, Reagents, Buffers, Flat-Bottom Blocks and Lids, 96-Well Microplates RB, AirPore Tape Sheets, Tape Pads 27361

DirectPrep 96 BioRobot Kit (4)

962341

Related products for BAC/PAC/P1 purification QIAGEN 10 QIAGEN-tip 500, Reagents, Buffers, Large-Construct Kit (10) ATP-Dependent Exonuclease R.E.A.L. Prep 96 Plasmid Kit (4) For 4 x 96 rapid extraction alkaline lysis minipreps: 4 QIAfilter 96 Plates, Square-Well Blocks, Tape Pads, Reagents, Buffers For 4 x 96 rapid extraction alkaline lysis minipreps: 4 QIAfilter 96 Plates, Flat-Bottom Blocks and Lids, Square-Well Blocks, Reagents, Buffers, Tape Pads 12462 26171

R.E.A.L. Prep 96 BioRobot Kit (4)

961141

QIAvac and accessories QIAvac 24 Plus Vacuum manifold for processing 124 spin columns: includes QIAvac 24 Plus Vacuum Manifold, Luer Plugs, Quick Couplings 19413

* Requires use of QIAvac Multiwell. Larger kit sizes available, please inquire. For use with BioRobot 3000 or 8000 workstations. Larger kit sizes available, please inquire. ATP solution required for exonuclease digestion is not provided. Requires use of QIAvac 96.

QIAprep Miniprep Handbook 12/2006

47

Ordering Information
Product QIAvac 6S Contents Vacuum manifold for processing 16 QIAGEN 8-well strips: includes QIAvac 6S Top Plate with flip-up lid, Base, Waste Tray, Blanks, Strip Holder Rock of Collection Microtubes (1.2 ml) Vacuum manifold for processing QIAGEN 96-well plates: includes QIAvac 96 Top Plate, Base, Waste Tray, Plate Holder Rock of Collection Microtubes (1.2 ml) For processing 124 QIAprep Spin Columns: 6 adapters, each with 4 luer connectors, 24 plugs For use with QIAvac manifolds Universal vacuum pump Universal vacuum pump Universal vacuum pump Cat. no. 19503

QIAvac 96

19504

QIAvac Luer Adapter Set* Vacuum Regulator Vacuum Pump (100 V, 50/60 Hz) Vacuum Pump (115 V, 60 Hz) Vacuum Pump (230 V, 50 Hz)

19541

19530 84000 84010 84020

Automated low-throughput plasmid purification QIAcube (110 V) QIAcube (230 V) Robotic workstation for automated purification 9001292 of nucleic acids or proteins using QIAGEN 9001293 spin-column kits, 1-year warranty on parts and labor

Accessories Starter Pack, QIAcube Pack includes: reagent bottle racks (3); rack labeling strips (8); 200 l filter-tips (1024); 1000 l filter-tips (1024); 1000 l filter-tips, wide-bore (1024); 30 ml reagent bottles (18); rotor adapters (240); rotor adapter holder 990395

* Compatible only with QIAvac Top Plates containing flip-up lid. US, Canada, and Japan. Rest of world. Agreements for comprehensive service coverage are available; please inquire.

The QIAcube is intended for research applications. No claim or representation is intended for its use to provide information for the diagnosis, prevention, or treatment of a disease.
48 QIAprep Miniprep Handbook 12/2006

Ordering Information
Product Contents Cat. no. Individual Buffers and accessories Buffer N3 Buffer PB RNase A 500 ml Buffer N3 500 ml Buffer PB 250 mg RNase A (70 U/mg; 100 mg/ml) 19064 19066 19065 19101 19201 19560 19566

Buffer PE (concentrate) 100 ml Buffer PE (concentrate) Collection Tubes (2 ml) 1000 collection tubes (2 ml) Collection Microtubes Nonsterile polypropylene tubes (1.2 ml), (racked) 960 in racks of 96 Collection Microtube Caps Nonsterile polypropylene caps for collection microtubes (1.2 ml), 960 in strips of 8, loose in bag

Flat-Bottom Blocks (24) 96-well blocks with 2 ml wells, 24 blocks per case Tape Pads (5) Adhesive tape sheets for sealing multiwell plates and blocks: 25 sheets per pad, 5 pads per pack Microporous tape sheets for covering 96-well blocks during bacterial cultivation: 50 sheets per pack

19579 19570

AirPore Tape Sheets (50)

19571

QIAprep Miniprep Handbook 12/2006

49

Notes

50

QIAprep Miniprep Handbook 12/2006

QIAGEN Distributors and Importers


Please see the back cover for contact information for your local QIAGEN office.
Argentina Tecnolab S.A. Tel: (011) 4555 0010 Fax: (011) 4553 3331 E-mail: info@tecnolab.com.ar Bosnia-Herzegovina MEDILINE d.o.o. Tel.: +386 1 830-80-40 Fax: +386 1 830-80-70 +386 1 830-80-63 E-mail: info@mediline.si Brazil Uniscience do Brasil Tel: 011 3622 2320 Fax: 011 3622 2323 E-mail: info@uniscience.com Chile Biosonda SA Tel: +562 209 6770 Fax: +562 274 5462 E-mail: ventas@biosonda.cl China Eastwin Scientific, Inc. Order: +86-400-8182168 Tel: +86-10-51663168 Fax: +86-10-82898283 E-mail: laborder@eastwin.com.cn Gene Company Limited Tel: +86-21-64951899 Fax: +86-21-64955468 E-mail: info_bj@genecompany.com (Beijing) info_sh@genecompany.com (Shanghai) info_cd@genecompany.com (Chengdu) info_gz@genecompany.com (Guangzhou) Genetimes Technology, Inc. Order: 800-820-5565 Tel: +86-21-54262677 Fax: +86-21-64398855 E-mail: order@genetimes.com.cn Colombia GENTECH Genetics & Technology Tel: (+57)(4)2519037 Fax: (+57)(4)2516555 E-mail: gerencia@gentechcolombia.com soporte@gentechcolombia.com Croatia INEL Medicinska Tehnika d.o.o. Tel: (01) 2984-898 Fax: (01) 6520-966 E-mail: inel-medicinska-tehnika@zg.htnet.hr Cyprus Scientronics Ltd Tel: +357 22 467880/90 Fax: +357 22 764614 E-mail: a.sarpetsas@biotronics.com.cy Czech Republic BIO-CONSULT spol. s.r.o. Tel/Fax: (+420) 2 417 29 792 E-mail: info@bioconsult.cz Ecuador INMUNOCHEM S.A.C. Tel: +51 1 4409678 Fax: +51 1 4223701 E-mail: inmunochem@terra.com.pe Egypt Clinilab Tel: Fax: E-mail: Lithuania INTERLUX Tel: +370-5-2786850 Fax: +370-5-2796728 E-mail: spirit@interlux.lt Malaysia RESEARCH BIOLABS SDN. BHD. Tel: (603)-8070 3101 Fax: (603)-8070 5101 E-mail: biolabs@tm.net.my Mexico Quimica Valaner S.A. de C.V. Tel: (55) 55 25 57 25 Fax: (55) 55 25 56 25 E-mail: ventas@valaner.com New Zealand Biolab Ltd Tel: (09) 980 6700 0800 933 966 Fax: (09) 980 6788 E-mail: biosciences@nzl.biolabgroup.com Oman Al Mazouri Medical & Chemical Supplies Tel: +971 4 266 1272 (ext. 301, 310, 311) Fax: +971 4 269 0612 (ATTN: LAB DIVISION) E-mail: shaji@almaz.net.ae Pakistan Pakistan Microbiological Associates Tel: +92-51-5567953 Fax: +92-51-5514134 E-mail: orderpma@comsats.net.pk Peru INMUNOCHEM S.A.C. Tel: +51 1 4409678 Fax: +51 1 4223701 E-mail: inmunochem@terra.com.pe Poland Syngen Biotech Sp.z.o.o. Tel: (071) 798 58 50 - 52 Fax: (071) 798 58 53 E-mail: info@syngen.pl Portugal IZASA PORTUGAL, LDA Tel: (21) 424 7312 Fax: (21) 417 2674 E-mail: consultasbiotec@izasa.es Qatar Sedeer Medical Tel: +974 - 488 5218 Fax: +974 - 488 1988 E-mail: sedeer@qatar.net.qa Romania Zyrcon Medical S. R. L. Tel: +40 21 2245607 Fax: +40 21 2245608 E-mail: virgil.dracea@zyrconmedical.ro secretariat@zyrconmedical.ro Saudi Arabia Abdulla Fouad Holding Company Tel: (03) 8324400 Fax: (03) 8346174 E-mail: sadiq.omar@abdulla-fouad.com Singapore Research Biolabs Pte Ltd Tel: 6777 5366 Fax: 6778 5177 E-mail: sales@researchbiolabs.com Slovak Republic BIO-CONSULT Slovakia spol. s.r.o. Tel/Fax: (02) 5022 1336 E-mail: bio-cons@cdicon.sk Slovenia MEDILINE d.o.o. Tel: (01) 830-80-40 Fax: (01) 830-80-70 (01) 830-80-63 E-mail: info@mediline.si South Africa Southern Cross Biotechnology (Pty) Ltd Tel: (021) 671 5166 Fax: (021) 671 7734 E-mail: info@scb.co.za Spain IZASA, S.A. Tel: (93) 902.20.30.90 Fax: (93) 902.22.33.66 E-mail: consultasbiotec@izasa.es Taiwan TAIGEN Bioscience Corporation Tel: (02) 2880 2913 Fax: (02) 2880 2916 E-mail: order@taigen.com Thailand Theera Trading Co. Ltd. Tel: (02) 412-5672 Fax: (02) 412-3244 E-mail: theetrad@samart.co.th Turkey Medek Medikal rnler ve Saglik Hizmetleri A. S. Tel: (216) 302 15 80 Fax: (216) 302 15 88 E-mail: makialp@med-ek.com United Arab Emirates Al Mazouri Medical & Chemical Supplies Tel: +971 4 266 1272 (ext. 301, 310, 311) Fax: +971 4 269 0612 (ATTN: LAB DIVISION) E-mail: shaji@almaz.net.ae Uruguay Bionova Ltda Tel: +598 2 6130442 Fax : +598 2 6142592 E-mail: bionova@internet.com.uy Venezuela SAIXX Technologies c.a. Tel: +58212 3248518 +58212 7616143 +58212 3255838 Fax: +58212 7615945 E-mail: ventas@saixx.com saixxventas@cantv.net Vietnam Viet Anh Instruments Co., Ltd. Tel: +84-4-5119452 Fax: +84-4-5119453 E-mail: VietanhHN@hn.vnn.vn All other countries QIAGEN GmbH, Germany

52 57 212 52 57 210 Clinilab@link.net

Estonia Quantum Eesti AS Tel: +372 7301321 Fax: +372 7304310 E-mail: quantum@quantum.ee Greece BioAnalytica S.A. Tel: (210)-640 03 18 Fax: (210)-646 27 48 E-mail: bioanalyt@hol.gr Hong Kong SAR Gene Company Limited Tel: +852-2896-6283 Fax: +852-2515-9371 E-mail: info@genehk.com Genetimes Technology International Holding Ltd. Tel: +852-2385-2818 Fax: +852-2385-1308 E-mail: hongkong@genetimes.com.hk Hungary BioMarker Kft. Tel: +36 28 419 986 Fax: +36 28 422 319 E-mail: biomarker@biomarker.hu India Genetix Tel: +91-11-51427031 Fax: +91-11-25419631 E-mail: genetix@genetixbiotech.com Indonesia PT Research Biolabs Tel: +62 21 5865357 E-mail: indonesia@researchbiolabs.com Iran Zist Baran (BIORAIN) Tel: +98 (21) 88066348 or +98 (21) 88066349 Fax: +98 (21) 88214107 E-mail: info@biorain.com Israel Eldan Electronic Instruments Co. Ltd. Tel: +972-3-937 1133 Fax: +972-3-937 1121 E-mail: bio@eldan.biz Jordan SAHOURY GROUP Tel: +962 6 4633290-111 Fax: +962 6 4633290-110 E-mail: info@sahoury.com Korea LRS Laboratories, Inc. Tel: (02) 924-86 97 Fax: (02) 924-86 96 E-mail: webmaster@lrslab.co.kr Philekorea Technology, Inc. Tel: (02) 576-6540 Fax: (02) 576-6541 E-mail: support@philekorea.co.kr Latvia SIA J.I.M. Tel: 7136393 Fax: 7136394 E-mail: jim@mednet.lv

QIAprep Miniprep Handbook 12/2006

51

Australia Orders 03-9840-9800 Fax 03-9840-9888 Technical 1-800-243-066 Austria Orders: 0800/28-10-10 Fax: 0800/28-10-19 Technical: 0800/28-10-11 Belgium Orders 0800-79612 Fax 0800-79611 Technical 0800-79556 Canada Orders 800-572-9613 Fax 800-713-5951 Technical 800-DNA-PREP (800-362-7737) China Orders 021-51345678 Fax 021-51342500 Technical 021-51345678 Denmark Orders 80-885945 Fax 80-885944 Technical 80-885942 Finland Orders 0800-914416 Fax 0800-914415 Technical 0800-914413 France Orders 01-60-920-920 Fax 01-60-920-925 Technical 01-60-920-930 Germany Orders 02103-29-12000 Fax 02103-29-22000 Technical 02103-29-12400 Ireland Orders 1800 555 049 Fax 1800 555 048 Technical 1800 555 061 Italy Orders 02-33430411 Fax 02-33430426 Technical 800 787980 Japan Telephone 03-5547-0811 Fax 03-5547-0818 Technical 03-5547-0811 Luxembourg Orders 8002-2076 Fax 8002-2073 Technical 8002-2067 The Netherlands Orders 0800-0229592 Fax 0800-0229593 Technical 0800-0229602 Norway Orders 800-18859 Fax 800-18817 Technical 800-18712 Sweden Orders 020-790282 Fax 020-790582 Technical 020-798328 Switzerland Orders 055-254-22-11 Fax 055-254-22-13 Technical 055-254-22-12 UK Orders 01293-422-911 Fax 01293-422-922 Technical 01293-422-999 USA Orders 800-426-8157 Fax 800-718-2056 Technical 800-DNA-PREP (800-362-7737)

W W W. Q I A G E N . C O M

1043788 12/2006

Bench Protocol: QIAprep Spin Miniprep Kit Using a Vacuum Manifold


Please tear off here

This protocol is designed for the purification of up to 20 g high-copy plasmid DNA from 15 ml overnight E. coli culture in LB medium using a vacuum manifold with luer connectors. New users and users wanting to purify low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods should refer to the detailed protocols provided in the QIAprep Miniprep Handbook, 2nd ed. Important: Read Things to do before starting (see reverse side) Procedure 1. 2. 3. Resuspend pelleted bacterial cells in 250 l Buffer P1 and transfer to a microcentrifuge tube. Add 250 l Buffer P2 and mix thoroughly by inverting the tube 46 times. If using LyseBlue reagent, solution turns blue. Add 350 l Buffer N3 and mix immediately and thoroughly by inverting the tube 46 times. If using LyseBlue reagent, solution turns colorless. 4. Centrifuge for 10 min at 13,000 rpm (~17,900 x g) in a table-top microcentrifuge. During centrifugation, prepare the vacuum manifold and QIAprep spin columns as described in the handbook (page 16 and 18). 5. 6. 7. Apply the supernatant from step 4 to the QIAprep spin column by decanting or pipetting. Switch on vacuum source to draw the solution through the QIAprep spin columns, and then switch off vacuum source. Recommended: Wash the QIAprep spin column by adding 0.5 ml Buffer PB. Switch on vacuum source. After the solution has moved through the column, switch off vacuum source. This step is only required when using endA+ or other bacteria strains with high nuclease activity or carbohydrate content (see QIAprep Miniprep Handbook for more details) 8. Wash the QIAprep spin column by adding 0.75 ml Buffer PE. Switch on vacuum source to draw the wash solution through the column, and then switch off vacuum source. Transfer the QIAprep spin columns to a microcentrifuge tube. Centrifuge for 1 min to remove residual wash buffer.

9.

10. To elute DNA, place the QIAprep column in a clean 1.5 ml microcentrifuge tube. Add 50 l Buffer EB or water to the center of each QIAprep spin column, let stand for 1 min, and centrifuge for 1 min.

Bench Protocol: QIAprep Spin Miniprep Kit Using a Microcentrifuge


Please tear off here

This protocol is designed for the purification of up to 20 g high-copy plasmid DNA from 15 ml overnight E. coli culture in LB medium. New users and users wanting to purify low-copy plasmids and cosmids, large plasmids (>10 kb), and DNA prepared using other methods should refer to the detailed protocols provided in the QIAprep Miniprep Handbook, 2nd ed. Things to do before starting

Add RNase A solution to Buffer P1. Optional: Add LyseBlue reagent to Buffer P1. Add ethanol (96100%) to Buffer PE. Check Buffers P2 and N3 for salt precipitation and redissolve at 37C if necessary.

Procedure 1. 2. 3. Resuspend pelleted bacterial cells in 250 l Buffer P1 and transfer to a microcentrifuge tube. Add 250 l Buffer P2 and mix thoroughly by inverting the tube 46 times. If using LyseBlue reagent, solution turns blue. Add 350 l Buffer N3 and mix immediately and thoroughly by inverting the tube 46 times. If using LyseBlue reagent, solution turns colorless. 4. 5. 6. 7. Centrifuge for 10 min at 13,000 rpm (~17,900 x g) in a table-top microcentrifuge. Apply the supernatant (from step 4) to the QIAprep spin column by decanting or pipetting. Centrifuge for 3060 s. Discard the flow-through. Recommended: Wash the QIAprep spin column by adding 0.5 ml Buffer PB and centrifuging for 3060 s. Discard the flow-through. This step is only required when using endA+ or other bacteria strains with high nuclease activity or carbohydrate content (see QIAprep Miniprep Handbook for more details) 8. 9. Wash QIAprep spin column by adding 0.75 ml Buffer PE and centrifuging for 3060 s. Discard the flow-through, and centrifuge for an additional 1 min to remove residual wash buffer.

10. To elute DNA, place the QIAprep column in a clean 1.5 ml microcentrifuge tube. Add 50 l Buffer EB or water to the center of each QIAprep spin column, let stand for 1 min, and centrifuge for 1 min.