Product Technical Information

July 15, 2020


Data shown is for the current revision model #. Ensure your nameplate model # matches.

Model Number: 5KS405DAJ6021D


Catalog Number: V4555
Instruction Manual: GEI-M1045
Connection Diagram: GEM2034E-FIG7
Outline Drawing: 148CB40VMHKCCLA0001

Accessory Connection Diagrams


Bearing Thermocouple: None Heater: 3027JE-1C
RTD: None Thermistor: None
Thermostat: 3027JE-2A Winding Thermocouple: None
Bearing RTD: None

Table of Contents
Specification 01
Performance Characteristics 02
Outline Drawing 03
Connection Drawing(s) 04
Spare parts 05
Model Number:5KS405DAJ6021D July 15, 2020

Marks:

MODEL NUMBER: 5KS405DAJ6021D Estimated Weight: 1150 Lbs


Outline Drawing: 148CB40VMHKCCLA0001 Time Rating: CONT
Connection Diagram: GEM2034E-FIG7 Enclosure: WPI
Instruction Book: GEI-M1045 Encl Construction: OPEN
Design Code: 40BD1168BA Ambient Max(°C): 40
Type: KS Alt Ambient Max(°C): --
Frame: L405TP16 Insulation Class: H
Phases: 3 NEMA Design: B
Poles: 4 Nominal Efficiency: 95.4 %
Output Power: 125HP 92.5KW Guaranteed Efficiency: 94.5 %
RPM: 1780 3/4 Load Efficiency: 94.9 %
Voltage: 575 KVA Code: G
Hertz: 60 Max KVAR: 42.2
Amps - FL: 119.0 Power Factor: 83.5
Service Factor: 1.15 Bearing - DE: 6215C3
Alt Service Factor: -- Bearing - ODE: 235A2532AA01

Enclosure is Weather Protected One

Stamped Nameplate Notes:


NEMA ENCLOSURE WP-I, CSA ENCL DP
HTR LDS HE1-HE2 115V 100W
ROT CCW FACING ODE LEAD/PH SEQ 1-2-3/1-2-3
THERMOSTAT LEADS TB1-TB2 TRIP
INVERTER DUTY PER NEMA MG1 PART 31
ALTERNATE RATING FOR PWM CONTROL:1.0SF 40C AMBIENT
VAR TORQUE RANGE 5-60 HZ
UPPER BRG LUBE OIL: 6 QTS
0 DEG C TO 40 DEG C : ISO 32(MINERAL OR SYNTHETIC)
-15 DEG C TO 0 DEG C : ISO 32 SYNTHETIC

Page | 1
Model Number:5KS405DAJ6021D July 15, 2020

Additional Information:

4P, VERT HOLLOW SHAFT HIGH THRUST (1D)


C/BOX 700 CU IN - 3.00" NPT
OIL RESISTANT SLEEVING ON LEADS
(3)N.C, CL F, TRIP TSTAT LDS TO MAIN CONDUIT BOX
115V HTR LDS TO MAIN CONDUIT BOX
GROUND PAD
INSULATED UPPER BEARING CARRIER
SHAFT GROUNDING RING MOUNTED ON LOWER END BRG CAP
BEARING LIFE 8760 HRS AT 7539 LB THRUST
CG:18.50 IN FROM P-BASE FACE,STAT DEF:0.0032 IN
RCF:3240 CPM AT C/BOX SIDE, 3360 CPM AT
90 DEG FROM C/ BOX SIDE
NON-REVERSE BALL CARRIER,
BOLTED COUPLING, BX=1.501, EW=.375
SPECIAL BALANCE

Page | 2
Model Number:5KS405DAJ6021D July 15, 2020

Performance Characteristics 1st Winding 1st Connection Design: 40BD1168BA


Marks:
LOAD % 125.0 115.0 100.0 75.0 50.0 25.0 0.0
% EFF 94.17 94.41 94.91 94.94 94.52 91.8 0.00
% PF 85.07 84.57 83.28 78.91 69 46.48 3.76
AMPS 146.04 134.81 118.42 93.7 71.75 54.84 47.13

TORQ(FL)#FT 368.44 TORQ(LR)%FL 146.28 TORQ(BD)%FL 251.81


AMPS(LR) 647.79 PF AT START 0.31
This motor is capable of two cold or one hot start with a maximum connected load inertia of 1908 Lb-Ft Sq (80.33 Kg-meter
Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum inertia
and the above load type is 28 seconds. Safe stall time at 100% voltage is 62 seconds cold, 33 seconds hot. Rotor inertia
is 21.53 Lb-Ft Sq (0.91 Kg-meter Sq).

Open Circuit A-C: 0.608 Short Circuit D-C: 0.025


Short Circuit A-C: 0.04 X/R Ratio: 9.244
Stator Slots: 72 Rotor Slots: 58

Page | 3
Model Number: 5KS405DAJ6021D July 15, 2020

Marks:
Model Number: 5KS405DAJ6021D July 15, 2020
Marks:

Connection Diagram Heater Connection


GEM2034E-FIG7 3027JE-1C

Thermostat Connection
3027JE-2A

Page | 5
Model Number: 5KS405DAJ6021D July 15, 2020

End shield Assembly


Part Description DE Side Part# ODE Side Part#
End Shield 115E7306AC1 115E7310LJ1
Bearing 235A2513AL01 235A2532AA01
Slinger/Inproseal 235A2300HW1

Fan & Fan Cover Assembly


Part Description Part#
Fan
Fan Cover 161C1054AA1

Conduit & Accessories Box Assembly


Part Description Part#
Conduit Box 118D4408AD2

Mechanical Accessories
Part Description Part#
Brake
Tachometer

Page | 6