MicroSAFA IP 66

Automatic fuel conditioning system


for daily tanks up to 1.000 liters volume
The MicroSAFA automatic fuel conditioning system for particle filtration,
water removal, fuel homogenization and oxygenation through its programmed
recirculation protocol, prevents the proliferation of bacteria, molds and yeasts
that are liable to damage the installation.

Why is it important to install MicroSAFA in my fuel tank?


As per current regulations trends in allowance limits, the diesel can be mixed
with till 7% of biodiesel. This fact modifies the fuel’s chemical structure and
causes a significant increase in condensation within the tank. The presence of
water combined with certain temperature conditions create a perfect medium
for the bacteria to grow, reproduce and create damages at the installation.

The Microsafa filtering system is the ideal solution to all these problems in
small installations, especially in emergency generators with poor fuel
rotation. The system eliminates solid particulate and water from the tanks
by means of a decanting filter. Additionally, it is fitted with a linear module that
induces lethargy in the bacteria thus limiting their capacity to proliferate.

TECHNICAL CHARACTERISTICS
CODE For larger capacity installations
21110000902399 MicroSAFA automatic filtering set and fuel storage yards above
Dimensions 400 x 300 x 150 mm 1000 lts capacity, the SAFA and
MiniSAFA filtering system models
Power supply 230 Vac guarantees prevention.
Consumption 100 mA
Maximum flow rate 20 L/h
Suction/Drive 1/4” - 1/4”
Drain 1/4”
Recommended for storage tanks of up to 1,000 L.

1 0,1 mm particle filter


SAFA Filtering System Basic Diagram 2 Water decanter
Fuel conditioner for microbial growth
3
prevention
Fuel circulation pump (preventing
4
degradation)
MicroSAFA

How does Micro SAFA operate?


• Circulates and prevents fuel degradation inside daily-supply tanks.
• Fuel is passed through a fuel conditioner to prevent microbial growth.
• The fuel is automatically distributed for a predetermined number of periods programmed to ensure that the contents
of the tank are recirculated at a rate of 1.5 times tank’s capacity every 28 days.
• If water is detected in the decanting filter in the unit, it triggers an alarm and a malfunction warning light comes
on (alarm). To reset this alarm, it will be necessary to manually drain the water, and press the reset button: only then
the pump will restart automatically at next programmed lap.
• The system is powered by 230 Vac and comprises a water decanting filter, fuel conditioner, flow detector, flow
failure display, timer.
• The MicroSAFA IP 66 is weatherproof: it’s protective cabinet enclosure allow outside mounting (Protection IP-66).

SCOPE OF CONTENTS
Nº Description Código Inpro
1 Fuel conditioner & water sep. 00020091414123
1.1 Fuel conditioner 00260011002408

2 Oil Filter
22050000010300
3 Electrode relay 02050000001000
4 Solenoid pump 15 l/h 01000000004660
5 Pressureswitch 02200000000005
6.1 Timer switch double controller 02010000932290

6.2 Aux. relay contact


02010000001490
7 IP 66 cabinet enclosure 02060004030201

Diagram and electrical connections

Inpro Research and Development S.L., C/Invierno, 4-6


ZN Deutschland Pol. Ind. “El Malvar”
63457 Hanau - Voltastraße, 10 28500 Arganda del Rey
Inpro Research and Development S.L., ZNDeutschland
Deutschland / Germany Madrid
Tel.: (+49) 06181/9587-0 Telf.: (+34) 918 719 294
Fax: (+49) 06181/958723 info@inprogroup.net
info@simka.de - www.simka.de www.inprogroup.net
MicroSAFA
Installation instructions
1.Prior to installation, clean all joins of any possible dirt that may reach the equipment.
2.Secure the equipment to a firm surface above the maximum level of the tank to be treated.
3.Connect hydraulic aspiration “A” and return “C” to the storage tank.
4.Connect power supply, 230 Vac.

Setup instructions (Unit operation)


Default settings:
Factory preset lap is: From 08.00 to 14.00 hours, at 10 minute intervals, every day of the week. (On 8.00 to 8.10 –
On 9.00 to 9.10…. – On 18.00 to 18:10).
The dual Timer allow a change on these values through a mobile phone with NFC technology and an application to
this effect, or manually by means of the timer. To make new settings, please contact our technical department to request
support for adjunsting the MiniSAFA, or download the app from your mobile device store (FINDER TOOLBOX)

Maintenance
When the red alarm lamp light comes on, check the water decanting filter to ensure it is free of solid particles, and
remove any water present. After this, start up the pump (e.g., manual timer) until the diesel reaches the pump and the
equipment is ready to operate in automatic mode.

EC DECLARATION OF CONFORMITY ACCORDING TO DIRECTIVE 2006/42/EC ANNEX II

INPRO R&D, S.L.


Pol. Ind. El malvar
C/ Invierno Naves 4,6
28500 Arganda del Rey (Madrid)
Telf.: (+34) 918 719 294
info@inprogroup.net - www.inprogroup.net

Declare under our sole responsibility that the machine PUMPSET for oil,

Type: Micro Safa


Serial Nr: XXXX
Manufacturing date: 2021

Is manufactured in conformity with the Machinery Directive 2006/42/EC, Electrical Safety Directive 2006/95/
EC and Electromagnetic Compatibility Directive 2004/108/CE.

Manufacturer will not be liable for:


• Not following of the instructions referred in the manuals delivered by INPRO R&D, S.L.
• Modifications to machine design not authorised by INPRO R&D, S.L.
• Damages caused during maintenance or repair performed by not authorized people by INPRO R&D, S.L.

For its construction EN 12.514-1, EN-ISO-9001 rules have been observed.

Quality Managemenr

Arganda del Rey, el 06 de February de 2017

Inpro Research and Development S.L., C/Invierno, 4-6


ZN Deutschland Pol. Ind. “El Malvar”
63457 Hanau - Voltastraße, 10 28500 Arganda del Rey
Inpro Research and Development S.L., ZNDeutschland
Deutschland / Germany Madrid
Tel.: (+49) 06181/9587-0 Telf.: (+34) 918 719 294
Fax: (+49) 06181/958723 info@inprogroup.net
info@simka.de - www.simka.de www.inprogroup.net

You might also like