Vickers®

Service Data
Pumps

High Pressure, High Performance


Double Vane Pump
2525VPF Series -21 Design

5009.03/EN/0396/S
To reverse Cartridge rotation remove
Retaining Ring and Bearing Carrier
S/A. Install Bearing Carrier S/A and
Retaining Ring in opposite end of
Cartridge and reinstall Cartridge facing
in opposite direction. For R.H. rotation
the end of the Cartridge with screw
heads showing will be installed toward
the cover end. For L.H. rotation the
end of the Cartridge with screw heads
showing will be installed toward the
shaft end.

913505 ‘A’ SAE Housing


913506 ‘B’ Metric Housing
Cartridge Kit, R.H. rotation shown (see table)
F 197658 B.U. Ring (2 Req’d)

F 587288 O’Ring (2 Req’d)


F 579373 O’Ring (2 Req’d)
F 197648 B.U. Ring (2 Req’d)

875584 Bearing Carrier S/A


190273 Retaining Ring
260281 O’Ring
913508 ‘A’ SAE Cover Shaft Seal Options
913509 ‘B’ Metric Cover
A – Primary seal only: spring loaded
sealing member facing inward.
B – Primary and secondary seals:
primary seal with spring loaded sealing
member facing inward and secondary
02–113364 Screw (4 Req’d)
seal with spring loaded sealing member
Dry–Torque to 274–336 Nm
(222–248 lb.ft.) facing outward.
Oiled–Torque to 206–252 Nm C – Primary and secondary seals: both
(152–186 lb.ft.) with spring loaded sealing member
facing inward.
Model Code F Cartridge Kit F Cartridge Kit NOTE: Lubricate all parts and seals with
(Cover and Shaft End) Standard Vitonr a thin coat of oil at assembly.
Parts prefixed with symbols are available
2525VPF–010 02–319101 02–319102
only in kits.
2525VPF–016 02–319103 02–319104 02–160534 STD Seal Kit, Single
2525VPF–025 02–319105 02–319106 Shaft Seal or
2525VPF–032 02–319107 02–319108 02–160535 Vitonr Seal Kit, Single
Shaft Seal
2525VPF–040 02–319109 02–319110 02–160536 STD Seal Kit, Double
2525VPF–050 02–319111 02–379112 Shaft Seal or
02–160537 Vitonr Seal Kit, Double
2525VPF–063 02–319113 02–319114
Shaft Seal
2525VPF–071 02–319115 02–319116 L Included in Flange Kits (See table).
2525VPF–080 02–319117 02–319118 D Included in Cartridge Kit (see table).
 Eaton Hydraulics, Incorporated 2000, Vitonr is a registered trademark of the E.I. DuPont
All Rights Reserved Co.
38441 Bearing
119982 Retaining Ring

193144 Retaining Ring Shaft (see table)


Key (see table)
Cartridge Kit, R.H. rotation shown (see table)

F 197658 B.U. Ring (2 Req’d)


587288 O’Ring (2 Req’d)
579373 O’Ring (2 Req’d)
F 197648 B.U.Ring (2 Req’d)
L103824 Retaining Ring 394973 Shaft Seal (see
(double shaft seal only) shaft seal options B and C)

260278 O’Ring
L 103824 Retaining Ring
394973 Shaft Seal (see
shaft seal options A, B and C)

913498 ‘A’ SAE Body


913499 ‘B’ Metric Body

L 1072 Screw
(4 Req’d)
Dry–Torque to 65–79 Nm
(48–58 lb.ft.)
L Flange (see table) Oiled–Torque to 48–58 Nm
(35–43 lb.ft.)
260281 O’Ring

Model Code Shaft Key


2525VPF–***–***–*–*–01 913266 928540 L Flange Kit
2525VPF–***–***–*–*–02 913267 Flange Type Single Shaft Seal Double Shaft Seal
2525VPF–***–***–*–*–03 913268 928545 SAE J744–101–2 (SAE B) 02–142476 02–142480
2525VPF–***–***–*–*–05 913269 928541 ISO 3019/2–100A2HW 02–142477 02–142481
2525VPF–***–***–*–*–06 877142 SAE J744 127–2 (SAE C) 02–142478 02–142482
2525VPF–***–***–*–*–07 913270 928546 ISO 3019/2–125A2HW 02–142479 02–142483
Model Code

1 2 3 4 5 6 7 8 9 10 11 12

1 Series designation (frame size) 4 Port connection 8 Seal type


2525VPF – 20 to 160 cm3/r
A – SAE 4-bolt flange N – Standard, Buna N
(1.22 to 9.76 in3/r)
B – Metric 4-bolt flange V – Vitonr
W – Buna N with Vitonr shaft seal(s)
2 Displacement – front section 5 Flange mounting style Vitonr is a registered trademark of the E.I. DuPont Co.

010 – 10 cm3/r (0.61 in3/r) A – SAE J744 101–2 (SAE B)


9 Outlet port no. 1 position
016 – 16 cm3/r (0.97 in3/r) B – ISO 3019/2 100A2HW
(viewed from cover end)
025 – 25 cm3/r (1.52 in3/r) C – SAE J744 127–2 (SAE C)
032 – 32 cm3/r (1.95 in3/r) D – ISO 3019/2 125A2HW A – Opposite inlet port
040 – 40 cm3/r (2.44 in3/r) B – 90° counterclockwise from inlet
050 – 50 cm3/r (3.05 in3/r)
6 Shaft port
063 – 63 cm3/r (3.84 in3/r 01 – SAE J744 25–1 C – Inline with inlet port
071 – 71 cm3/r (4.33 in3/r) (1.00 in keyed shaft) D – 90° clockwise from inlet port
080 – 80 cm3/r (4.88 in3/r) 02 – SAE J744 25–4
(B–B splined shaft)
03 – ISO 3019/2 E25N 10 Outlet port no. 2 position
3 Displacement – rear section (25mm keyed shaft) (viewed from cover end)
010 –10 cm3/r (0.61 in3/r) 05 – SAE J744 32–1 A – Opposite inlet port
016 –16 cm3/r (0.97 in3/r) (1.25 in keyed shaft) B – 90° counterclockwise from
025 –25 cm3/r (1.52 in3/r) 06 – SAE J744 32–4 inlet port
032 –32 cm3/r (1.95 in3/r) (C splined shaft) C – Inline with inlet port
040 –40 cm3/r (2.44 in3/r) 07 – ISO 3019/2 E32N D – 90° clockwise from inlet port
050 –50 cm3/r (3.05 in3/r) (32mm keyed shaft)
063 –63 cm3/r (3.84 in3/r
071 –71 cm3/r (4.33 in3/r) 11 Design
7 Shaft seal
080 –80 cm3/r (4.88 in3/r)
A – Single, primary 12 Rotation
B – Double, secondary (spring side (viewed from shaft end)
out) R – Right hand (clockwise)
C – Double, secondary (spring side in) L – Left hand (counterclockwise)

Typical sectional view


Eaton Hydraulics
15151 Highway 5 46 New Lane, Havant
Eden Prairie, MN 55344 Hampshire PO9 2NB
Telephone: 612 937-7254 England
Fax: 612 937-7130 Telephone: (44) 170-548-6451
www.eatonhydraulics.com Fax: (44) 170-548-7110

Form No. 00-000 Copyright Eaton Corporation, 0000


All rights reserved.
Printed in U.S.A

You might also like