Service Data
Pumps
5009.03/EN/0396/S
To reverse Cartridge rotation remove
Retaining Ring and Bearing Carrier
S/A. Install Bearing Carrier S/A and
Retaining Ring in opposite end of
Cartridge and reinstall Cartridge facing
in opposite direction. For R.H. rotation
the end of the Cartridge with screw
heads showing will be installed toward
the cover end. For L.H. rotation the
end of the Cartridge with screw heads
showing will be installed toward the
shaft end.
260278 O’Ring
L 103824 Retaining Ring
394973 Shaft Seal (see
shaft seal options A, B and C)
L 1072 Screw
(4 Req’d)
Dry–Torque to 65–79 Nm
(48–58 lb.ft.)
L Flange (see table) Oiled–Torque to 48–58 Nm
(35–43 lb.ft.)
260281 O’Ring
1 2 3 4 5 6 7 8 9 10 11 12