Code 0x8003001D Could Not Access File For Write Operation - Received When Trying To Change Security Gateway Version
Code 0x8003001D Could Not Access File For Write Operation - Received When Trying To Change Security Gateway Version
"code 0x8003001D could not access file for write operation" received when trying to Technical Level
Solution ID sk166013
Technical Level
Product SmartConsole
Version R80.10 (EOL)
OS Gaia
Date Created 03-Aug-2020
Last Modified 10-Oct-2020
Symptoms
Changing the Security Gateway version to R80.10 causes the object to be unable to saved, the following error is shown:
"failed to save object server error is an internal error has occored. code 0x8003001D could not access file for write operation.
Please contact internal support".
Cause
A lock exists on an IPS exception.
Solution
Remove the locked session from SmartConsole: Manage & Settings > Administrators.
This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.