Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
24 views11 pages

CANEC2287631034 - AW0331F (Release Liner)

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 11

Test Report. No.

CANEC2287631034
CANEC228763103 Date:
Date:17
17Aug
Aug2022
2022 . Page 1 of 11.

Avery Dennison(China) Co,.Ltd..


No.608,kunjia Road, Kun shan Economic&Technological Zone Jiangsu Province,P.R.China
.

The following sample(s) was/were submitted and identified on behalf of the clients as : BG40Wh Imp
SGS Job No. : CP22-086860 - GZ.
Date of Sample Received :. 11 Aug 2022.
Testing Period :. 11 Aug 2022 - 17 Aug 2022
.
Test Requested :. Selected test(s) as requested by client..
Test Method :. Please refer to next page(s)..

Test Results :. Please refer to next page(s)..


Conclusion :. Based on the performed tests on submitted sample(s), the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs),
Polybrominated diphenyl ethers (PBDEs) and Phthalates such as
Bis(2-ethylhexyl) phthalate (DEHP) , Butyl benzyl phthalate (BBP), Dibutyl
phthalate (DBP) , and Diisobutyl phthalate (DIBP) comply with the limits as set by
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU..

Signed for and on behalf of


SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.

Dongyu Xie.
Approved Signatory.
Test Report. No. CANEC2287631034 Date: 17 Aug 2022. Page 2 of 11.

Test Results :.

Test Part Description :.

Specimen No.. SGS Sample ID. Description.


SN1. CAN22-876310.003
CAN21-276317.003 White sheet.

Remarks :.
(1) 1 mg/kg = 0.0001%.
(2) MDL = Method Detection Limit.
(3) ND = Not Detected ( < MDL ).
(4) "-" = Not Regulated.

RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.

Test Method :. With reference to IEC 62321-4:2013+A1:2017, IEC 62321-5:2013, IEC 62321-7-2:2017 , IEC
62321-6:2015 and IEC 62321-8:2017, analyzed by ICP-OES , UV-Vis and GC-MS ..

Test Item(s). Limit. Unit. MDL. 001.


Cadmium (Cd). 100 mg/kg. 2 ND
Lead (Pb). 1,000 mg/kg. 2 ND
Mercury (Hg). 1,000 mg/kg. 2 ND
Hexavalent Chromium (CrVI). 1,000 mg/kg. 8 ND
Sum of PBBs. 1,000 mg/kg. - ND
Monobromobiphenyl. - mg/kg. 5 ND
Dibromobiphenyl. - mg/kg. 5 ND
Tribromobiphenyl. - mg/kg. 5 ND
Tetrabromobiphenyl. - mg/kg. 5 ND
Pentabromobiphenyl. - mg/kg. 5 ND
Hexabromobiphenyl. - mg/kg. 5 ND
Heptabromobiphenyl. - mg/kg. 5 ND
Octabromobiphenyl. - mg/kg. 5 ND
Nonabromobiphenyl. - mg/kg. 5 ND
Decabromobiphenyl. - mg/kg. 5 ND
Sum of PBDEs. 1,000 mg/kg. - ND
Monobromodiphenyl ether. - mg/kg. 5 ND
Dibromodiphenyl ether. - mg/kg. 5 ND
Tribromodiphenyl ether. - mg/kg. 5 ND
Tetrabromodiphenyl ether. - mg/kg. 5 ND
Pentabromodiphenyl ether. - mg/kg. 5 ND
Test Report. No. CANEC2287631034
CANEC228763103 Date: 17 Aug 2022. Page 3 of 11.

Test Item(s). Limit. Unit. MDL. 001.


Hexabromodiphenyl ether. - mg/kg. 5 ND
Heptabromodiphenyl ether. - mg/kg. 5 ND
Octabromodiphenyl ether. - mg/kg. 5 ND
Nonabromodiphenyl ether. - mg/kg. 5 ND
Decabromodiphenyl ether. - mg/kg. 5 ND
Dibutyl phthalate (DBP). 1,000 mg/kg. 50 ND
Butyl benzyl phthalate (BBP). 1,000 mg/kg. 50 ND
Bis (2-ethylhexyl) phthalate (DEHP). 1,000 mg/kg. 50 ND
Diisobutyl Phthalates (DIBP). 1,000 mg/kg. 50 ND

Notes :.
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.IEC 62321 series is
equivalent to EN 62321 series
http://www.cenelec.eu/dyn/www/f?p=104:30:1742232870351101::::FSP_ORG_ID,FSP_LANG_ID:12586
37,25.

Halogen.

Test Method :. With reference to EN 14582:2016, analysis was performed by IC..

Test Item(s). Unit. MDL. 001.


Chlorine (Cl). mg/kg. 50 ND
171
Bromine (Br). mg/kg. 50 ND

Hexabromocyclododecane (HBCDD).

Test Method :. With reference to IEC 62321:2008, analysis was performed by GC-MS..

Test Item(s). Unit. MDL. 001.


Hexabromocyclododecane (HBCDD). mg/kg. 10 ND

PFOA & PFOS (Perfluorooctanoic acid & Perfluorooctane sulfonates).

Test Method :. With reference to CEN/TS15968:2010, analysis was performed by LC-MS..


Test Report. No. CANEC2287631034 Dat
De 1 7 Aug01
a:te:71D 022.
2021
8 Page 4 of 11.

Test Item(s). CAS NO. Unit. MDL. 001.


Perfluorooctanoic acid (PFOA). 335-67-1. mg/kg. 10. ND.
Perfluorooctane Sulfonates (PFOS)^. -. mg/kg. 10. ND.

Notes :.
(1) ^ PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid,
Perfluoroctane sulfonamide, N-Methylperfluoroctane sulfonamide, N-Ethylperfluoroctane sulfonamide,
N-Methylperfluoroctane sulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol..

European Regulation (EC) No. 850/2004 and its amendment Regulation (EU) 2015/2030 -Chlorinated
Paraffins --Articles.

Test Method :. With reference to ISO 18219: 2015, analysis was performed by GC-NCI-MS / GC-ECD..

Test Item(s). Limit. Unit. MDL. 001.


Alkanes C10-C13, chloro (short-chain chlorinated paraffins) (SCCPs). 1500. mg/kg. 50. ND.
Comment. PASS.
Test Report. No. CANEC2287631034 Date: 17 Aug 201
221. Page 5 of 11.

ATTACHMENTS
Pb/Cd/Hg/Cr6+/PBBs/PBDEs Testing Flow Chart
1) These samples were dissolved totally by pre-conditioning method according to below flow chart.
(Cr6+ and PBBs/PBDEs test method excluded).

Sample Preparation

Sample Measurement

Pb/Cd/Hg PBBs/PBDEs Cr6+

Acid digestion with Sample solvent


microwave / extraction Nonmetallic Metallic
hotplate material material
Concentration/ ABS/PC/PVC Others
Filtration Dilution of Boiling water
extraction solution extraction
Dissolving by Digesting at
Solution Residue ultrasonication 150~160℃
Filtration Adding 1,5-
diphenylcarba
1) Alkali Fusion / zide for color
GC-MS Digesting at Separating to
Dry Ashing development
2) Acid to 60°C by get aqueous
dissolve DATA ultrasonication phase
UV-Vis.

ICP-OES/AAS pH adjustment
DATA

DATA Adding 1,5-


diphenylcarbazide for
color development

UV-Vis

DATA
Test Report. . No. CANEC2287631034 Date: 17 Aug
Sep 2022.
2021 Page 6 of 11.

ATTACHMENTS
Phthalates Testing Flow Chart

Sample cutting / preparation

Sample Measurement

Solvent extraction

Concentration/Dilution

Filtration

GC-MS

DATA
Test Report. No. CANEC2287631034 Date: 17 Aug
Sep 2022.
2021 Page 7 of 11.

ATTACHMENTS
Halogen Testing Flow Chart

Sample cutting / preparation

Sample Measurement

Combustion in a closed system containing oxygen

Dissolved in an absorption solution

Filtration

Analyzed by ion chromatography. Double confirm by other


instruments, if necessary

DATA
Test Report. No. CANEC2287631034 Date: 17 Aug
SeP 2022.
2021 Page 8 of 11.

ATTACHMENTS
HBCDD Testing Flow Chart

Sample cutting / preparation

Sample Measurement

Solvent extraction

Concentration/Dilution

Filtration

GC-MS

DATA
Test Report. No. CANEC2287631034 Date: 17 Aug
Sep 2022.
2021 Page 9 of 11.

ATTACHMENTS
PFOA / PFOS Testing Flow Chart

Sample cutting / preparation

Sample Measurement

Solvent extraction

Concentration/Dilution

Filtration

LC-MS

DATA
Test Report. No. CANEC2287631034 Date: 17 Aug
Sep 2022.
2021 Page 10 of 11.

ATTACHMENTS
SCCP/MCCP/LCCP Testing Flow Chart

Sample cutting / preparation

Sample Measurement

Solvent extraction

Concentration

Clean-Up

Filtration

GC-ECD

DATA
Test Report. No. CANEC2287631034 Date: 17 Aug
Sep 2022
2021. Page 11 of 11.

Sample photo:.

CANEC2287631034

CAN22-876310.003.
.001

SGS authenticate the photo on original report only.


*** End of Report ***.