Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Concentricity Checking Fixture

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

6 5 4 3 2 1

Parameter:-
Component :- 26 mm flare cartridge
D item no. 1, 2, 12, 16. this Dimension D
will be inspected on this Gauge

Component :- 50 mm flare cartridge


item no. 3, 7, this Dimension
will be inspected on this Gauge
C C

Procedure:-
1. place Componet on roller by
B B
lifting bearing Assembly.
2. place dialpoint on Component as per
requirement and make zero on dial.
3. rotate spindle (spindle will rotate componet)
note down reading on dial.
4. repeat procedure for next Component.
A Designed by

USEr
Checked by Approved by Date Date

05-12-2023
A
Concentricity inspection DAP drg Universal Concentricity
1/3 G
Edition Sheet

6 5 4 3 2 1
6 5 4 3 2 1

PARTS LIST
D 9 3 13 11 ITEM QTY PART NUMBER DESCRIPTION D
1 1 Base Plate
2 1 Main Spindle Block
3 4 Bearing Cap
12 4 4 Bearing
5 2 Brg spacer Inner race
2 6 2 Brg spacer outer race
14 7 2 Live Center
C 8 2 Bearing Locknut C
9 2 Rotating Knob
10 1 Case for Cartridge 26 flare
11 1 Vertical Column to Hold spring
12 1 Bearing Holder
13 1 Bearing Shaft
14 1 Bearing 625zz
15 1 MGWR15R110CM-Rail STEP AP214
16 1 MGW15CZFC-Block STEP AP214
B 17 4 Foot B
17 1
18 1 base for Dial stand
Note;-
1. spindle Rotation with help of belt design Pending
2. Stopper for component will be opposite to Dial
7 18 16 15 3. Dial Attachment design Pending
A Designed by

USEr
Checked by Approved by Date Date

05-12-2023
A

Universal Concentricity
2/3 G
Edition Sheet

6 5 4 3 2 1
6 5 A-A ( 1 : 2 ) 4 3 2 1
50
4
D D
4
256

C C

25
B B

200

A
A
A Designed by

USEr
Checked by Approved by Date Date

05-12-2023
A
300
Universal Concentricity
3/3 G
Edition Sheet

6 5 4 3 2 1

You might also like