Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SOP For Cleaning of S.S. Bins, Containers, Pallet, Hosepipes Material Transfer Pipe and Accessories

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 5

Version No.

1
Title:

Document No: SOP for Cleaning of S.S. Bins, Containers, Pallet, Page No.
SOP/OS/021 Page 1 of 5
Hosepipes Material Transfer Pipe and Accessories

Effective Date Revision Date

SOP for Cleaning of S.S. Bins, Containers, Pallet, Hosepipes


Material Transfer Pipe and Accessories

Prepared by: X X
Department Name Date

Approved by: Y Y
Department Name Date

Authorized by: Z Z
Department Name Date

1. Purpose
Version No.
1
Title:

Document No: SOP for Cleaning of S.S. Bins, Containers, Pallet, Page No.
SOP/OS/021 Page 2 of 5
Hosepipes Material Transfer Pipe and Accessories

Effective Date Revision Date

This procedure defines the requirements for the cleaning procedure of S.S. bins, Containers,
Pallet, Hosepipes Material transfer pipe and Accessories..

2. Scope
This procedure is applicable to .S. bins, Containers, Pallet, Hosepipes Material transfer pipe
and Accessories production line in

3. Validity

This SOP is valid only until next revision date and if it bears control seal.

4. Responsibility

It will be the responsibility of the tablet line leaders& operators to follow the procedure.
Quality assurance manager is responsible for SOP compliance.

5. Material and Equipment

2%v/v approved non-ionic detergent solution & nylon scrubber.

6. Procedure
6.1. S.S. bins & plastic containers:
6.1.1. Transfer the stainless steel (S.S) bin/container to the washroom.
6.1.2. Wash the S.S. bin/container with potable water.
6.1.3. Clean the S.S. bins/containers with 2%v/v approved non-ionic detergent solution
using nylon scrubber.
6.1.4. Rinse the S.S. bins/containers with running potable water to remove the detergent.
6.1.5. Finally rinse the S.S. bins/containers with purified water.
6.1.6. Air dry the S.S. bins/containers.
6.1.7. Store the S.S. bins/clean containers at designated place on pallets.
6.1.8. Use nose mask and hand gloves when handling acids or alkali solution.
Version No.
1
Title:

Document No: SOP for Cleaning of S.S. Bins, Containers, Pallet, Page No.
SOP/OS/021 Page 3 of 5
Hosepipes Material Transfer Pipe and Accessories

Effective Date Revision Date

6.1.9. In case of container used for


6.1.9.1. Film coating solution, clean the container with 10%v/v glacial acetic acid
solution, using nylon scrubber followed by rinsing with potable water twice
and purified water once.
6.1.9.2. Enteric coating solution, clean the container with 10%w/v sodium
carbonate solution using nylon scrubber, followed by rinsing with potable
water twice and purified water once.
6.2. S.S. Accessories, S.S. Scoops, S.S. Spatulas and Measures:
6.2.1. Take the accessories to washroom.
6.2.2. Wash the accessories with 2%v/v approved non-ionic detergent solution using
nylon scrubber.
6.2.3. Rinse the accessories with running potable water to remove the detergent.
6.2.4. Finally rinse the accessories with purified water.
6.2.5. Store the clean accessories in a dry clean equipment rack and allow it to dry.
6.2.6. In case used for,
6.2.6.1. Film coating solution, clean it with 10% glacial acetic acid solution
followed by rinsing with potable water twice and purified water once.
6.2.6.2. Enteric coating solution, clean it with 10% sodium carbonate solution
using nylon scrubber, followed by rinsing with potable water twice and
purified water once.
6.3. Hosepipes:
6.3.1. Transfer the hosepipes to the washroom.
6.3.2. Clean thoroughly each hosepipe with running potable water from one end to the
other, both from inner and outer side.
6.3.3. Rinse the hosepipe with 20 litres of running purified water.
6.3.4. Dry the hosepipe using compressed air. Check the cleanliness and drying, and
cover the mouth with stretch film.
Version No.
1
Title:

Document No: SOP for Cleaning of S.S. Bins, Containers, Pallet, Page No.
SOP/OS/021 Page 4 of 5
Hosepipes Material Transfer Pipe and Accessories

Effective Date Revision Date

6.4. Pallets:
6.4.1. Transfer the pallet to the washroom.
6.4.2. Wash each pellet with running potable water thoroughly.
6.4.3. Scrub the pallet with 2% approved non-ionic detergent solution using nylon
scrubber
6.4.4. After all stains are removed, clean the pallet with 25 litres of running potable
water.
6.4.5. Finally rinse the pellet with 30 litres of purified water.
6.4.6. Keep the pallet in slanting position in clean room till dry.
6.5. Material transfer pipe:
6.5.1. Transfer the material transfer pipe to the washroom.
6.5.2. Wash each material transfer pipe with 20 litres of running potable water.
6.5.3. Clean the material transfer pipe with 1 litre of 2% non-ionic detergent solution
with brush.
6.5.4. Remove the detergent solution with 25 litres of running potable water.
6.5.5. Finally rinse the material transfer pipe with 30 litres purified water.
6.5.6. Intimate QA to collect wash water sample of material transfer pipe.
6.5.7. Dry the material transfer pipe with air blower.

Note: The cleaning of the equipments remains valid for 48 hours. If the equipment is not used
within 48 hours then it should be re cleaned as per cleaning procedure for product changeover.

7. Abbreviations:
SOP Standard Operating Procedure
8. Related Documents /Applicable document/
None

9. Revision History
Version No.
1
Title:

Document No: SOP for Cleaning of S.S. Bins, Containers, Pallet, Page No.
SOP/OS/021 Page 5 of 5
Hosepipes Material Transfer Pipe and Accessories

Effective Date Revision Date