The document discusses the basic formulas and factors associated with ANSI 51 protection used in electrical systems, including pickup current setting, time delay setting, time-current curves, multiplier factor, system impedance and fault analysis, and coordination with other protective devices.
The document discusses the basic formulas and factors associated with ANSI 51 protection used in electrical systems, including pickup current setting, time delay setting, time-current curves, multiplier factor, system impedance and fault analysis, and coordination with other protective devices.
The document discusses the basic formulas and factors associated with ANSI 51 protection used in electrical systems, including pickup current setting, time delay setting, time-current curves, multiplier factor, system impedance and fault analysis, and coordination with other protective devices.
The document discusses the basic formulas and factors associated with ANSI 51 protection used in electrical systems, including pickup current setting, time delay setting, time-current curves, multiplier factor, system impedance and fault analysis, and coordination with other protective devices.
Download as RTF, PDF, TXT or read online from Scribd
Download as rtf, pdf, or txt
You are on page 1of 2
Certainly, here are the basic formulas and factors commonly associated with ANSI 51
protection (time-overcurrent relay protection) used in electrical systems:
1. Pickup Current Setting (I_pickup):
This represents the threshold current level at which the relay starts to operate. Formula: I_pickup = (Multiplier) × (Rated Current of the Protected Equipment) The multiplier factor is typically set between 1.5 to 2.5 times the rated current to ensure sensitivity to fault conditions while avoiding nuisance tripping during normal operation. 2. Time Delay Setting (T_delay): This is the delay before the relay trips after the current exceeds the pickup level. The time delay allows discrimination between transient overcurrents and genuine faults. The relationship between time and current is often depicted by time- current curves or coordination curves. 3. Time-Current Curves: These curves graphically illustrate the relationship between the magnitude of the fault current and the time it takes for the relay to operate (trip). They help in setting appropriate time delays for different levels of overcurrents to coordinate with other protective devices in the system. 4. Multiplier Factor: The multiplier factor (K-factor) is a crucial parameter used to determine the pickup current of the relay. It's typically determined based on system characteristics, coordination requirements, and standards. Common values range from 1.5 to 2.5, but can vary based on specific system needs and relay characteristics. 5. System Impedance and Fault Analysis: Understanding the impedance of the system and conducting fault analysis helps in determining the appropriate settings for the relay. Higher system impedance might require higher multiplier factors for sensitive protection. 6. Coordination with Other Protective Devices: ANSI 51 protection settings must be coordinated with other protective devices in the system, such as relays, fuses, and circuit breakers, to ensure selective operation and prevent unnecessary tripping.
These formulas, factors, and considerations are fundamental in setting up ANSI 51
protection for electrical systems. They help determine the relay's sensitivity to faults, its response time, and its coordination with other protective devices, all aimed at providing effective protection while ensuring system stability and reliability.