Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Kipas

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

CEILING FAN

Model : AX666-5B/56
AX666-5B/40
Version: 2020 V1
TABLE OF CONTENT SAFETY PRECAUTION

Item Page No. CAUTION


1. Safety Precautions ............................................................................... 1 - 2 Please take note of the following important points when installing.

The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a
2. Parts & Accessories .............................................................................. 3 sufficient strength to withstand 4 times the weight of the ceiling fan.

3. Installation Instruction ........................................................................... 4 - 7 The mounting of the suspension system shall be performed by the manufacturer, its service agent or
suitably qualified persons.
4. Transmitter Learning Process, Assembly & Function ........................... 8 - 9 The fan is to be installed so that the blades are more than 2.5m above the floor.

5. Power Supply Connection & Circuit Diagram ........................................ 10 Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing
conductor. The earthing terminal in the fan assembly should be such that should any part of the suspen-
6. Maintenance .......................................................................................... 11 sion system fall off, the body of the fan assembly shall effectively earthed.

7. Technical Specifications ........................................................................ 11 - 12 Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
8. Customer Service Centre ...................................................................... 12 Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from
being in contact with these places.

Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF”
position.
SAFETY PRECAUTION If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to
service personnel or the user.
Warning Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil
vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or
Installation and maintenance work shall only be performed by qualified persons, familiar with local code chemical reaction.
and regulation, and experienced with this type of appliance.
Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors respec-
All field wiring must be installed in accordance with the national wiring regulation. tively.

Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring Don’t use joined and twisted wires for incoming power supply.
work according to the wiring diagram. Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
The unit must be GROUNDED to prevent possible hazard due to insulation failure. The fan suspension system and blade screw tightening shall be examined yearly.
The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby the
suspension system fails, the (L) and (N) wire will break leaving the fan remain earthed to prevent electro- Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its
cution. service agent or suitably qualified persons.

Tighten the blade firmly using a screw driver. Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.
Blades that are detached from the unit during operation will cause serious injuries and property damages.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliances.

Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that
the blade is fully static before doing any maintenance work.

STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the
manufacturer, its service agent or suitably qualified persons.

1 2
PARTS & ACCESSORIES INSTALLATION INSTRUCTION

Step 1 Step 3
Assemble the Canopy and Coupling Cover through Fix the Rubber Pulley Assembly to the Downrod
the Downrod. with Bolt, Washer, Nut and tighten them firmly,
then insert the Clevis Pin.

IMPORTANT : Clevis Pin MUST be inserted to


Canopy prevent Nut from loosening.

Motor Assembly Canopy Coupling Cover


Downrod

Coupling
Cover

Fan Blade x 5 Downrod


Step 2
a) Route all the wires from the Motor through
the Downrod.
b) Fix the Downrod to the coupling with Bolt,
Washer, Nut and tighten them firmly then insert
the Clevis Pin.

IMPORTANT : Clevis Pin MUST be inserted to


Rubber Pulley Assembly Receiver prevent Nut from loosening.

Green/ Step 4
Transmitter & Holder x 1
Yellow (E)
a) Remove the Bolt, Clevis Pin, Nut, Washer and
Brown (L) Rubber Pulley.
2
3
4
Battery x 2
LIGHT
Blue (N) b) Place the Rubber Pulley onto the ceiling hook
Bolt, Washer, Nut
ON/OFF

Blade Screw x 11
1 5
AAA
and Clevis Pin x 2
FAN OFF
Safety Wire and fix back the Bolt, Clevis Pin, Nut and Washer.
1H AAA
2H
4H
6H
IMPORTANT : Clevis Pin MUST be inserted to
8H prevent Nut from loosening.

Washer & Nut


Clevis Pin
Rubber
Pulley Clevis Pin
Coupling Nut
Washer

Clamp the downrod


Bolt
with the 2 screws Safety
on the coupling to Wire
prevent shaking
during operation.

3 4
INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION

Step 5 Step 7
Remove the Safety Wire screw and spring washer from the Downrod. Firmly screw the Safety Wire with spring washer onto the Downrod.

Step 6 Step 8
Tie the Safety Wire across the hook as shown. Connect the Connectors from Fan and Receiver. Connect the wires from the receiver to House’s Supply
Wire. Connect Earth Wire to House Supply Earth Terminal.

House Supply Wires

Brown (L)
Green/Yellow (E)
Blue (N)

Brown (L)
Blue (N)

From Motor To Motor


Brown (L) Brown (L)
Blue (N) Blue (N)

Green/Yellow (E)

In the case of “J” Hook is being used.

5 6
INSTALLATION INSTRUCTION TRANSMITTER LEARNING PROCESS

Step 9 The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more `fans using 1
Install the Blades on Motor with Screw. transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
IMPORTANT : Assemble the Fan Blades only after the ceiling fan is mounted on the hook.
Step 1
a) Insert the 2 pcs of batteries (provided) into transmitter.
b) Turn on the power supply (wall switch) to the fan.
c) Within 10 sec, press and hold the “1” and “2” button for 3 sec. Once the receiver has detected the
frequency, transmitter will “Beep Beep” twice. Programming process is completed and fan is ready to use.
If the fan is not responding to the transmitter, repeat Step 1b.

3
2 4
LIGHT
ON/OFF
Press and hold 1 5
for 3 sec FAN OFF

1H
2H
4H
6H
8H

Below shows a complete installation diagram.

7 8
TRANSMITTER ASSEMBLY POWER SUPPLY CONNECTION

1. Insert the 2 pcs of AAA battery (provided) into the Transmitter. IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER
2. Mount the Transmitter Holder on the wall with the screws provided. SWITCH OR REGULATOR.

Transmitter

Transmitter Holder

Regulator Dimmer Switch


AAA
AAA

TRANSMITTER FUNCTION

CIRCUIT DIAGRAM
3
2 4
Fan Speed LIGHT IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER
ON/OFF
1 - Lowest speed 1 5 SWITCH OR REGULATOR.
5 - Highest speed FAN OFF
Power
1H
Turn off fan
Thermal
2H
Fuse
4H (Inside
Timer On Motor Motor
6H Motor) Capacitor
1h - Fan turns on after 1 hour
8H
2h - Fan turns on after 2 hours To Fan L Brown Grey Red White
L
4h - Fan turns on after 4 hours
6h - Fan turns on after 6 hours Yellow Pink
8h - Fan turns on after 8 hours
Main
PCB
To Fan N Blue
N

Last Memory Function


The Transmitter & Receiver is incorporated with last memory function. It stores the last reading/setting on
memory and when the fan is switch on again, the operation will be as the last memory/setting.
E

9 10
MAINTENANCE TECHNICAL SPECIFICATIONS

Due to the fan’s natural movement, connections may get loose after period of usage. To ensure a proper
and safety usage, it is highly recommended to inspect and tighten all connections every 6 months.

Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures 365mm
(1’ 2”) 395mm
are as follows : (1’ 4”)
1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution. More than 1m
2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will
scratch the surface.
3. Do not bent the blades while cleaning. At the event where blades are bent or damage, AX666-5B/56 1420mm (4’ 8”)
order new set of blades from service center or dealer shop. AX666-5B/40 1030mm (3’ 4”)
4. There is no need to oil the fan.

More than 2.5m (8’ 2”)


TECHNICAL SPECIFICATIONS

Model AX666-5B/56 AX666-5B/40


No. of Blades 5 5
Fan Width 56” 40”
Motor RPM 105 - 230 140 - 270
Voltage 220 - 240V~ 50Hz 220 - 240V~ 50Hz
Motor Wattage 80W 70W
CUSTOMER SERVICE CENTRE
Nett Weight 7.3kg 6.7kg
If you need any technical assistance or faulty report, please contact our customer service centre at :

Alpha Home Appliances Sdn. Bhd. (390258-H)


Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460 Shah Alam, Selangor.
Tel : 03-5740 6666 Fax : 03-5740 8220
Website : www.alphamalaysia.com Email : info@alphamalaysia.com

Johor Bahru : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
Tel : 07-353 4833 / 4933 Fax : 07-355 4233

Melaka : 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
Tel : 06-292 6292 / 6293 Fax : 06-292 6296

Ipoh : 11, Laluan Tasek Timur 5, Pusat Perdagangan Tasek Indra, 31400 Ipoh, Perak.
Tel : 05-545 2282 / 547 2282 Fax : 05-547 6282

Penang : 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.
Tel : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966

Pahang : A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
Tel : 09-516 5226 Fax : 09-513 9226

11 12

You might also like