Maquet Magnus
Maquet Magnus
Maquet Magnus
This document is intended to provide information to an international audience outside of the US.
| 2 | MAGNUS | Surgical Workplaces |
| Surgical Workplaces | MAGNUS | 3 |
Modern system solutions: the procedures that are carried The goal is efficient and gentle patient treatment, an ideal
out every day in clinical practice can no longer be seen in working environment and an optimum in-house workflow.
isolation. Efficient workflows demand that operational equip- With the MAGNUS OR table, Maquet designed a system,
ment and work processes are optimally matched to each which links patient care, the operating area, diagnostics and
other. The MAGNUS OR and transport system is an integral post-operative care much more closely. And that benefits
component of a closely dovetailed logistics system. Coordi- both patients and users.
nation and ergonomics for the user and comfort for patients
are just as important as the commercial aspects. Maquet | The Gold Standard
| 4 | MAGNUS | Surgical Workplaces |
| Surgical Workplaces | MAGNUS | 5 |
Thanks to the Easy Click technology, Pressure relieving cushioning is easy Intuitive, hand controller with back-lit The MAGNUS OR table column
it just takes a single hand movement to clean and does not impede X-rays. key panel and extensive allows extreme inclination angles
to interchange the MAGNUS modules, position memory. which enable the table top to be ex-
easily and safely. tended a very long way for X-ray ex-
aminations, both cranial and caudal.
| 6 | MAGNUS | Surgical Workplaces |
Elevated postition
Lowered postition
Fast and smooth transport: from emergency treatment in The transfer board made of carbon fibre reinforced
the trauma room through to the operating theatre – the multi plastic or Kevlar provides the link between the ward and
functional Maquet transfer board offers patient transport other departments. It completes the MAGNUS patient trans-
without having to transfer the patient. It has been developed port and positioning system. Both uninterrupted service and
in such a way that transfer is possible from the patient trans- the smoothness of surgical processes are significantly in-
porter to the operating table. This puts less strain on both creased.
patients and personnel and saves valuable time.
Patient transport
Connecting bracket 1180.36A0 with mounting Extension device 1180.19A0 Back plate for shoulder operations 1180.34A0
points for skull clamp and other head supports
Basic table top Motor-driven joint module Pair of leg plates, 4-part
1180.10A0 1180.11B0 1180.54A0
| 10 | MAGNUS | Surgical Workplaces |
MAGNUS facilitates all surgical interventions: due to Maximum adjustability – the new manoeuvrability in
its perfect height adjustment, the OR table top contributes OR tables: the inclination saddle concept supports even ex-
to relaxed working, both while standing and sitting. Extreme treme table adjustments with angles that far exceed current
adjustment ranges, particularly for inclination and tilt, facili- standards. As a result, MAGNUS offers new possibilities,
tate and optimise patient positioning. This system feature particularly with minimally invasive surgery. But other surgical
offers levels of functionality that have never been achieved disciplines also benefit from this new development. Today,
before. MAGNUS is already designed for the future.
The modular, structural concept ticks all the boxes, when it comes to Extreme longitudinal position for intra-operative radioscopy and excellent
positioning requirements freedom of access for the OR team. Positioning example: nephrectomy in
lateral position
Positioning example: thorax surgery in lateral position Genucubital position for intervertebral disc or rectal surgery with the
4-part standard leg plate (no special accessories required)
| Surgical Workplaces | MAGNUS | 11 |
1,410 mm
500 mm
The height-adjustable table column provides an ergonomically suitable working Maximum height for working while standing
position while seated
| 12 | MAGNUS | Surgical Workplaces |
Extreme positions and optimum access: the OR table Mobile OR table column: the mobile column can be
column is the core of the MAGNUS system. Its inclination moved by a transporter together with the OR table top and
saddle technology allows for inclination angles up to 80° with can be set down at any location. Power is supplied through
simultaneous tilt angles of up to 45°, ensures stable lateral maintenance-free batteries, which are integrated into the
tilt and provides optimum radioscopy conditions and free ac- column base and last for at least one week of surgical work.
cess to the surgical field, with a corresponding working radi-
us. The OR table top can easily be transferred from the Independently manoeuvrable OR table column: this
transporter to the table column without the need for reposi- version is equipped with its own castors and can easily be
tioning. Less strain for the staff – more care for the patient. moved without an additional transporter, even during surgery.
Mobile MAGNUS table column, manoeuvrable with transporter Independently manoeuvrable OR table column with extendible castors
Supporting patients and staff alike: Simplifying repositio- Technology for the logistic challenges of modern clinical procedures
Positioning examples
Lithotomy position and neurosurgery
Lithotomy position
MAGNUS facilitates the most versatile positionings MAGNUS is electrically adjustable with extreme inclination
for an optimum and ergonomically suitable access to the angles and easily extendable with various additional devices.
surgical field.
Preparation in gynaecology: initial phase with transfer board Intervention in lithotomy position with leg holders attached on motor-driven
joint module
Neurosurgery
The length of the back plate can be adjusted to accommodate different patient
sizes
| Surgical Workplaces | MAGNUS | 15 |
Positioning examples
Knee-elbow position and spinal surgery
Knee-elbow position
Preparation and positioning for spinal and rectal surgery. comfortable position for the patient and optimum access for
The inclination saddle technology and the modules provide a the surgeon.
Spinal surgery
Spinal surgery in prone position with optimum access for the C-armsizes Spinal surgery with the device for spinal surgery for optimum radioscopy of the
spinal column in ap and 360°
Note: All illustrated patient positions are only examples and incomplete from a nursing / medical viewpoint. If required, additional accessories should be used for
patient safety, e. g. body support or vacuum mattress.
| 16 | MAGNUS | Surgical Workplaces |
Positioning examples
Supine position
Maximum head down position up to 80° with simultaneous lateral tilt up to 45° Stable position even with extreme tilt
Position with optimised gravity, e. g. for bariatric surgery or fundoplication Positioning example: low foot setting approx. 50°; maximum up to 80°
| Surgical Workplaces | MAGNUS | 17 |
Struma surgery with relaxed neck positioning Laparoscopic and conventional cholecystectomy: optimum access to the
operating field
Minimally invasive total hip replacement with extension device Care of femoral neck fracture with extension device
Note: All illustrated patient positions are only examples and incomplete from a nursing / medical viewpoint. If required, additional accessories should be used for
patient safety, e. g. body support or vacuum mattress.
| 18 | MAGNUS | Surgical Workplaces |
Technical Specifications
and construction features
80°
Radioscopy access with positioning in head direction Radioscopy access with positioning in foot direction Foot down / head down tilt, max. 80°
45°
80°
90°
90° 60°
1,240 mm
535 mm
Highest position without cushioning Lowest position without cushioning Left / right tilt: max. 45° Back plate position: up / down +90°/-60°,
Leg plate position: up / down +80°/-90°,
Lower leg plate: up / down +90°/-90°
OR table top
A0 Modular universal OR table top
• OR table top as symmetrically divided basic unit, with • OR table top can be adjusted using plug-in modules
identical interfaces on both sides, allowing for individual (see below) for various specialist surgical disciplines or
configuration, depending on surgical requirements. different patient body sizes. Mounting points for easy,
• Plug-in modules may be selected as required safe adaptation of modules such as:
• Table top has radioscopy window between the bars with- ––Motorised joint module 1180.11A0/B0
out crossbars, for intra-operative use of image intensifier ––Standard back plate 1180.31A0
• OR table top frame and side rails (10 x 25 mm) made of ––Extension plate1180.32A0
stainless steel ––Transfer board as leg support for the initial phase
• Radiolucent, 80 mm thick hybrid cushioning, with electrical in lithotomy position 1180.57A0
discharging capacity The support plates can easily be ––Leg plates, divided into four, can be bent, spread
removed for cleaning, without tools and raised for genucubital position 1180.54A0
• The central cushioning segment in a sandwich design, ––Back plate for shoulder operations 1180.34A0
including wear-protection with visco-elastic foam and ––Carbon-fibre plate 1180.45A0
bi-elastic cover, offers excellent pressure distribution and ––Extension device 1180.19A0
reduces the shearing forces ––Single-joint head rest 1180.50A0
• Electro-powered drive of the OR table top provides longitu- ––Dual-joint head rest 1180.53A0
dinal shift (free-positioning for radioscopic examination
with C-arm), as well as “Back plate up / down” and “Leg Very easy adaptation is ensured using a snap connector
plates up / down” (Easy Click system). Device is immediately held in place
• All drives with electronically controlled gentle start-up for to prevent accidental loosening.
jerk-free travel with every movement, providing maximum
patient comfort. External table top control
• Return to the last stored patient position following C-arm • Optionally, the table top can be adjusted independently
control in modified patient position, using the hand control- of the column on the transporter. This ensures compliance
ler with nursing and anaesthesia requirements relating to
• Easy storing and recalling of up to 10 patient positions adjustments of the patient position during the initial phase
using the hand controller. Horizontal adjustment of all mo- or in the recovery room.
torised table top segments, including OR column head • The table top can also be moved to the beach chair
through zero position function. The practical horizontal ad- position on the transporter. This allows patients to be
justment of the individual functions complies with medical transported in a comfortable position, even over longer
requirements and avoids unfavourable intermediate posi- distances.
tions for the patient.
Compliant with the directives of the applicable guidelines; classification in accordance with MPA Class I
· 07/2015 · ® MAQUET is a registered Trademark · Copyright by MAQUET GmbH · Subject to modifications due to technical development.
MAQUET GmbH
Kehler Str. 31, 76437 Rastatt, Germany
Phone: +49 7222 932-0, Fax: +49 7222 932-571
info.sales@maquet.de
www.maquet.com
This document is intended to provide information to an international audience outside of the US.