Maquet – The Gold Standard

Modern system solutions: the procedures that are carried The goal is efficient and gentle patient treatment, an ideal
out every day in clinical practice can no longer be seen in working environment and an optimum in-house workflow.
isolation. Efficient workflows demand that operational equip- With the MAGNUS OR table, Maquet designed a system,
ment and work processes are optimally matched to each which links patient care, the operating area, diagnostics and
other. The MAGNUS OR and transport system is an integral post-operative care much more closely. And that benefits
component of a closely dovetailed logistics system. Coordi- both patients and users.
nation and ergonomics for the user and comfort for patients
are just as important as the commercial aspects. Maquet | The Gold Standard
| 4 | MAGNUS | Surgical Workplaces |
| Surgical Workplaces | MAGNUS | 5 |

A class of its own


MAGNUS OR table system

MAGNUS links functional areas: in addition to the actual


operation, preparation, transport and post-operative care
play a further significant and logistically complex role in all
surgical disciplines. For this reason, Maquet has been work-
ing for decades on solutions to integrate the individual fields
and their different challenges into a variable and comprehen-
sive system. The MAGNUS OR table system is the convincing
culmination of these efforts. With its special chassis frame
and the compatible transfer board, MAGNUS enables the
patients to be transferred gently from their bed to the operat-
ing table top. The electrically adjustable table top ensures
the transport to the operating theatre or diagnostic centre
in a position appropriate to the needs of the patient.
Until the table top and the patient are finally transferred by
the MAGNUS table column automatically and without any
further stress.

 AGNUS extends the operative spectrum: particularly


M • The Easy Click system and the various positioning
in minimally invasive surgery, extreme positions are often modules ensure maximum flexibility
required in order to provide an optimum exposure area • Special cushioning provides excellent pressure release
using gravity. Here, MAGNUS is setting new standards, with • Intuitively operated hand controller ensures fast and un-
inclination angles of up to 80° and tilt angles of up to 45°, complicated intra-operative repositioning
which can also be combined. Together with modules that • The inclination saddle technology of the table column pro-
have been designed specifically to work with each other, this vides extreme inclination angles and maximum positioning
opens up almost unlimited positioning options as well as new freedom for optimum radioscopy
and ergo­nomically optimised surgical working methods.

Thanks to the Easy Click technology, Pressure relieving cushioning is easy Intuitive, hand controller with back-lit The MAGNUS OR table column
it just takes a single hand move­ment to clean and does not impede X-rays. key panel and extensive allows extreme inclination angles
to interchange the MAGNUS modules, position memory. which enable the table top to be ex-
easily and safely. tended a very long way for X-ray ex-
aminations, both cranial and caudal.
| 6 | MAGNUS | Surgical Workplaces |

Ergonomic working conditions


In every position

Elevated postition

Upright and free of strain: the MAGNUS table top can


be raised to a height of 1,320 mm. This allows surgeons to
operate comfortably from a standing position, e. g. during
a total hip replacement in the dorsal position. Non-tiring
working conditions that provide relief from potential back
strain, even during longer surgery.

Lowered postition

Relaxed arms and shoulders: the extremely low setting


of the MAGNUS OR table system ensures safe and stress-
free operating, e. g. in minimally invasive laparoscopic inter-
ventions. A step stool is not needed.
| Surgical Workplaces | MAGNUS | 7 |

Transfer-free patient transport – Transfer board


for diagnosis, surgery and control

Fast and smooth transport: from emergency treatment in The transfer board made of carbon fibre reinforced
the trauma room through to the operating theatre – the multi­ plastic or Kevlar provides the link between the ward and
functional Maquet transfer board offers patient transport other departments. It completes the MAGNUS patient trans-
without having to transfer the patient. It has been developed port and positioning system. Both uninterrupted service and
in such a way that transfer is possible from the patient trans- the smoothness of surgical processes are significantly in-
porter to the operating table. This puts less strain on both creased.
patients and personnel and saves valuable time.

Patient transport

Patient admissions Kevlar transfer board

Transfer board, suitable for MRI (magentic resonance imaging)


operating table 1150.13 or 1180.13
Patient transport
| 8 | MAGNUS | Surgical Workplaces |

The system – easy and versatile


for the challenges of today and tomorrow

MAGNUS allows for optimum positioning: the perfectly


coordinated modular design of the operating table top pro-
vides functionalities and positional options that make both
microsurgical and complex interventions significantly easier
and more flexible. The table system is ergonomically designed
to facilitate relaxed working and deliver the best possible pa-
tient comfort, both for in-patient and out-patient applications.
The combination of the innovative table column inclination
saddle technology, the extreme working radius and the opti-
mised cushioning concept provides an overall system, which
is already equipped to cope today with the requirements of
the future.

A perfectly co-ordinated system

Head rest Extension plate Back plate Motor-driven joint module


1180.53A0 1180.32A0 1180.31A0 1180.11A0
| Surgical Workplaces | MAGNUS | 9 |

Connecting bracket 1180.36A0 with mounting Extension device 1180.19A0 Back plate for shoulder operations 1180.34A0
points for skull clamp and other head supports

Basic table top Motor-driven joint module Pair of leg plates, 4-part
1180.10A0 1180.11B0 1180.54A0
| 10 | MAGNUS | Surgical Workplaces |

Flexibility and modularity


MAGNUS OR table top

MAGNUS facilitates all surgical interventions: due to Maximum adjustability – the new manoeuvrability in
its perfect height adjustment, the OR table top contributes OR tables: the inclination saddle concept supports even ex­-
to relaxed working, both while standing and sitting. Extreme treme table adjustments with angles that far exceed current
adjustment ranges, particularly for inclination and tilt, facili- standards. As a result, MAGNUS offers new possibilities,
tate and optimise patient positioning. This system feature particularly with minimally invasive surgery. But other surgical
offers levels of functionality that have never been achieved disciplines also benefit from this new development. Today,
before. MAGNUS is already designed for the future.

The modular, structural concept ticks all the boxes, when it comes to Extreme longitudinal position for intra-operative radioscopy and excellent
positioning requirements freedom of access for the OR team. Positioning example: nephrectomy in
lateral position

Positioning example: thorax surgery in lateral position Genucubital position for intervertebral disc or rectal surgery with the
4-part standard leg plate (no special accessories required)
| Surgical Workplaces | MAGNUS | 11 |

Cushioning and radioscopy


MAGNUS cushioning concept and working radius

Best prerequisites for intra-operative radioscopy: due


to its extreme working radius, MAGNUS achieves a position
where the patient is almost “floating”, providing optimum
radioscopy possibilities and free access to the surgical field
from all directions.

Pressure-relieving positioning: in numerous test studies


on foam type and structure, height and cover material, Ma-
quet has developed operating table cushioning that offers
All cushioning can be
excellent positioning comfort and patient safety. It provides
removed without tools
a particularly efficient distribution of the pressure, reduced and is easy to clean
shearing forces and safe lateral support. and disinfect.

Foot 1,420 mm Head 1,380 mm

Maximum caudal working radius Maximum cranial working radius

1,410 mm

500 mm

The height-adjustable table column provides an ergonomically suitable working Maximum height for working while standing
position while seated
| 12 | MAGNUS | Surgical Workplaces |

Stability – for safe operations


MAGNUS OR table columns

Extreme positions and optimum access: the OR table Mobile OR table column: the mobile column can be
column is the core of the MAGNUS system. Its inclination moved by a transporter together with the OR table top and
saddle technology allows for inclination angles up to 80° with can be set down at any location. Power is supplied through
simultaneous tilt angles of up to 45°, ensures stable lateral maintenance-free batteries, which are integrated into the
tilt and provides optimum radioscopy conditions and free ac- column base and last for at least one week of surgical work.
cess to the surgical field, with a corresponding working radi-
us. The OR table top can easily be transferred from the Independently manoeuvrable OR table column: this
transporter to the table column without the need for reposi- version is equipped with its own castors and can easily be
tioning. Less strain for the staff – more care for the patient. moved without an additional transporter, even during surgery.

Mobile MAGNUS table column, manoeuvrable with transporter Independently manoeuvrable OR table column with extendible castors

Control and positions


MAGNUS hand-operated controller

Intuitive operation – easier than ever: the MAGNUS hand


controller is fitted with a display and self-explanatory icon
keys, which facilitate fast and intuitive handling. Up to ten
different patient positions can be stored and recalled from
the integrated program memory. Intermediate storing
is also possible, e. g. when using an intra-operative C-arm in
the flat position and then returning to the operating position.
The display, which is available in various language versions,
provides useful status information and indicates possible
operating faults, as required. Moreover, the back-lit key panel
considerably simplifies work in a darkened endoscopy room.
Using an infrared signal or cable, the hand controller ensures
Intuitively recognisable icons on the hand controller. Back-lit keys ensure com-
safe operation of the OR table system even during critical fortable and safe working in a darkened operating theatre.
phases of surgery.
| Surgical Workplaces | MAGNUS | 13 |

Movability, positioning and ergonomics:


MAGNUS transporters

Fast, safe and comfortable-in-use for the nursing staff:


Transporters with additional functions are twhe future-proof
response to the growing requirements of clinical procedures.
Because of its special chassis frame and the electrically ad-
justable table top, MAGNUS simplifies the transport of seated
and recumbent patients within the operating theatre.

Easy handling and safe manoeuvring: The MAGNUS


transporter has various castor settings: Tracking wheels for
stable straight-line travel, four movable castors for lateral
movement or locked castors for a safe parking position. It
can be activated or deactivated easily and ergonomically
through a foot lever.

Supporting patients and staff alike: Simplifying repositio- Technology for the logistic challenges of modern clinical procedures

ning, protecting the back muscles of the staff and optimally


supporting patients during every phase of surgery with co-
ordinated positioning options. MAGNUS exceeds the possi-
bilities of an OR table and is the lynchpin of modern OR
proceedures. The MAGNUS patient table top can also be ad-
justed on the transporter using an electric motor.

Whether the patient is in the “shock position” or “head


down” for a comfortable initial phase or with the back plate
in the upright position, e. g. in spinal anaesthesia or to sup-
port the patient’s respiration post-operatively, the MAGNUS
transporter always remains independent and flexible with its
lithium-ion battery and ensures ideal patient care at every
stage and at every location, inside or outside the operating
theatre.
Simple, back-friendly operation of the various castor settings, through a foot lever

Independent power supply through a high quality and completely stable


lithium-ion battery
| 14 | MAGNUS | Surgical Workplaces |

Positioning examples
Lithotomy position and neurosurgery

Lithotomy position
MAGNUS facilitates the most versatile positionings MAGNUS is electrically adjustable with extreme inclination
for an optimum and ergonomically suitable access to the angles and easily extendable with various additional devices.
surgical field.

Preparation in gynaecology: initial phase with transfer board Intervention in lithotomy position with leg holders attached on motor-driven
joint module

Neurosurgery

The length of the back plate can be adjusted to accommodate different patient
sizes
| Surgical Workplaces | MAGNUS | 15 |

Positioning examples
Knee-elbow position and spinal surgery

Knee-elbow position
Preparation and positioning for spinal and rectal surgery. comfortable position for the patient and optimum access for
The inclination saddle technology and the modules provide a the surgeon.

Spinal surgery

Spinal surgery in prone position with optimum access for the C-armsizes Spinal surgery with the device for spinal surgery for optimum radioscopy of the
spinal column in ap and 360°

Note: All illustrated patient positions are only examples and incomplete from a nursing / medical viewpoint. If required, additional accessories should be used for
patient safety, e. g. body support or vacuum mattress.
| 16 | MAGNUS | Surgical Workplaces |

Positioning examples
Supine position

Maximum head down position up to 80° with simultaneous lateral tilt up to 45° Stable position even with extreme tilt

Position with optimised gravity, e. g. for bariatric surgery or fundoplication Positioning example: low foot setting approx. 50°; maximum up to 80°
| Surgical Workplaces | MAGNUS | 17 |

Struma surgery with relaxed neck positioning Laparoscopic and conventional cholecystectomy: optimum access to the
operating field

Minimally invasive total hip replacement with extension device Care of femoral neck fracture with extension device

Note: All illustrated patient positions are only examples and incomplete from a nursing / medical viewpoint. If required, additional accessories should be used for
patient safety, e. g. body support or vacuum mattress.
| 18 | MAGNUS | Surgical Workplaces |

Technical Specifications
and construction features

80°

Head 1,380 mm Foot 1,420 mm

Radioscopy access with positioning in head direction Radioscopy access with positioning in foot direction Foot down / head down tilt, max. 80°

45°
80°
90°
90° 60°
1,240 mm

535 mm

Highest position without cushioning Lowest position without cushioning Left / right tilt: max. 45° Back plate position: up / down +90°/-60°,
Leg plate position: up / down +80°/-90°,
Lower leg plate: up / down +90°/-90°

MAGNUS OR table column Available in four versions


• OR table column for mounting system-compatible 1180.01A0 Stationary version for installation into
operating table tops built-in base plate 1120.98A0 or 1150.98A0
• Adaptive transfer: Table column automatically recognises the • Liquid-tight installation, flush with upper edge of finished
transfer position and guides the column head accordingly floor; can be rotated through approx. 350°; can be locked
• Electronically driven column in any position
• Transfer of the operating table tops from both sides and • Power supply to the operating table column through
with free selection of orientation of head or foot first. Auto- stationary transformer unit with battery buffer
matic recognition of orientation direction of the operating
1180.01B0 Stationary column with floor mounting plate
table top on the column and corresponding allocation of
for installation on finished floor
the functional keys on the control units
• Power supply, same as 1180.01A0
• Horizontal alignment of the column head (post-operative),
either by activating the zero position function through the 1180.01C0 Mobile column, can be moved with transporter
hand controller or by positioning the transporter and acti- • Power supply for the operating table column through
vating the “Height up / down” column function maintenance-free batteries, integrated into the base plate;
• Activation of the motorised movements of the OR table operating capacity between two charging cycles, approx.
system using the infrared hand-held controller, cabled hand 1 OR week
controller or foot lever as well as through the • Batteries are recharged and OR table column is operated
additional operating panel, which is integrated in the OR through a mains supply, using a mobile transformer unit,
table column which is included in the scope of delivery
• Two splash-protected plug-type connections for the parallel
1180.01D0 Independently manoeuvrable column, can
connection of cabled hand controller and foot lever
be moved using the integrated castors and activated
• Column casing made of stainless steel
by the hydraulic pedal-operated pump
• Power supply, same as 1180.01C0
| Surgical Workplaces | MAGNUS | 19 |

OR table top
A0 Modular universal OR table top
• OR table top as symmetrically divided basic unit, with • OR table top can be adjusted using plug-in modules
identical interfaces on both sides, allowing for individual (see below) for various specialist surgical disciplines or
configuration, depending on surgical requirements. different patient body sizes. Mounting points for easy,
• Plug-in modules may be selected as required safe adaptation of modules such as:
• Table top has radioscopy window between the bars with- ––Motorised joint module 1180.11A0/B0
out crossbars, for intra-operative use of image intensifier ––Standard back plate 1180.31A0
• OR table top frame and side rails (10 x 25 mm) made of ––Extension plate1180.32A0
stainless steel ––Transfer board as leg support for the initial phase
• Radiolucent, 80 mm thick hybrid cushioning, with electrical in lithotomy position 1180.57A0
discharging capacity The support plates can easily be ––Leg plates, divided into four, can be bent, spread
removed for cleaning, without tools and raised for genucubital position 1180.54A0
• The central cushioning segment in a sandwich design, ––Back plate for shoulder operations 1180.34A0
including wear-protection with visco-elastic foam and ––Carbon-fibre plate 1180.45A0
bi-elastic cover, offers excellent pressure distribution and ––Extension device 1180.19A0
reduces the shearing forces ––Single-joint head rest 1180.50A0
• Electro-powered drive of the OR table top provides longitu- ––Dual-joint head rest 1180.53A0
dinal shift (free-positioning for radioscopic examination
with C-arm), as well as “Back plate up / down” and “Leg Very easy adaptation is ensured using a snap connector
plates up / down” (Easy Click system). Device is immediately held in place
• All drives with electronically controlled gentle start-up for to prevent accidental loosening.
jerk-free travel with every movement, providing maximum
patient comfort. External table top control
• Return to the last stored patient position following C-arm • Optionally, the table top can be adjusted independently
control in modified patient position, using the hand control- of the column on the transporter. This ensures compliance
ler with nursing and anaesthesia requirements relating to
• Easy storing and recalling of up to 10 patient positions adjustments of the patient position during the initial phase
using the hand controller. Horizontal adjustment of all mo- or in the recovery room.
torised table top segments, including OR column head • The table top can also be moved to the beach chair
through zero position function. The practical horizontal ad- position on the transporter. This allows patients to be
justment of the individual functions complies with medical transported in a comfortable position, even over longer
requirements and avoids unfavourable intermediate posi- distances.
tions for the patient.

Technical specifications Motorised adjustments


Length of universal table top: Height (without cushioning)
Head-side configuration with 1 joint module, Stationary column 535 – 1,240 mm
back plate, extension plate and head rest 1,945 mm Mobile columns 565 – 1,270 mm
Length of universal table top: Inclination: head down / foot down 80° / 80°
Leg-side configuration with 1 joint module, Tilt, left / right 45° / 45°
head rest and leg plates 2,055 mm
Longitudinal shift 460 mm
Width of universal table top 540 mm
Back plates up / down +90° / -60°
Width across side rails 580 mm
Leg plates up / down +80° / -90°
Radioscopy window between the bars 410 mm
Max. patient weight incl. accessories:
Stationary columns 380 kg
Mobile column 1180.01C0 380 kg
Mobile column 1180.01D0 250 kg

Compliant with the directives of the applicable guidelines; classification in accordance with MPA Class I
· 07/2015 · ® MAQUET is a registered Trademark · Copyright by MAQUET GmbH · Subject to modifications due to technical development.

MAQUET GmbH
Kehler Str. 31, 76437 Rastatt, Germany
Phone: +49 7222 932-0, Fax: +49 7222 932-571
info.sales@maquet.de

www.maquet.com

Getinge Group is a leading global provider of products and systems


that contribute to quality enhancement and cost efficiency within
healthcare and life sciences. We operate under the three brands of
ArjoHuntleigh, Getinge and Maquet. ArjoHuntleigh focuses on patient
mobility and wound management solutions. Getinge provides
MSW-BR-10000045-EN-5

solutions for infection control within healthcare and contamination


prevention within life sciences. Maquet specializes in solutions,
therapies and products for surgical interventions, interventional
car­diology and intensive care.

This document is intended to provide information to an international audience outside of the US.

You might also like