Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Skylight Example 6

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

GENERAL NOTES

1) ALUMINUM SKYLIGHT "A" TO BE GAMCO STRUCTURAL HIP RIDGE SKYLIGHT SYSTEM.


FOR 1" INSUL. GLAZING

EXAMPLE SKYLIGHT 6 FINISH - DARK BRONZE ANODIZED

2) ALL GLASS TO BE 1" INSULATED UNITS CONSISTING OF:


1/4" CLEAR TEMPERED LOW E (#2 SURFACE) OUTBOARD LITE
ARCHITECTURAL
COMMUNICATION
AND DESIGN

PROJECT ADDRESS 1/2" AIR SPACE


1/4" CLEAR ANNEALED LAMINATED INBOARD LITE
231 E. 2100 S. SUITE 200
SALT LAKE CITY, UT 84115
800-658-8780, 801-298-9700
www.windowdraftsman.com
3) THE SKYLIGHT FRAME WILL BE DELIVERED TO THE JOB SITE KNOCKED DOWN FOR ASSEMBLY BY GAMCO
INSTALLERS. THE INSULATED GLASS UNITS WILL BE IN SPARATE CRATE(S). THE CUSTOMER IS RESPONSIBLE
TO LIFT FRAME MATERIALS TO THE ROOF. GLAZING AND INSTALLATION BY INSTALLERS.
THESE DRAWINGS AND DESIGNS ARE THE
INTERPRETATION OF ARCHITECTURAL
COMMUNICATION AND DESIGN AS GIVEN BY
THE ESTIMATED WEIGHT OF THIS SKYLIGHT SYSTEM THE GLAZING CONTRACTOR, ANY AND ALL
WITH INSULATED GLASS IS 1,335 LBS. EACH. STRUCTURAL LIABILITY PERTAINING TO THIS PROJECT LIES

ANALYSIS OF CURB, ROOF AND WALL SYSTEM BY 1 3/8" SNAP ON CAP SOLELY WITH THE GLAZING CONTRACTOR.

OTHERS. CURB MUST BE DESIGNED TO ACCOMMODATE


LATERAL LOADS OF SKYLIGHT SYSTEM. SUBSTRATE SNAP-ON COVER
TO WHICH THE SKYLIGHT SYSTEM WILL BE ANCHORED DRAWN: AUTH: DATE:
MUST BE OF ADEQUATE STRENGTH AND MUST BE RUBBER GASKETS

1/2"
ALIGNED IN SUCH A CONFIGURATION AS TO MEET ML WD 1/3/2020
ALL GENERALLY ACCEPTED COMMERCIAL TOLERANCES.
THE CUSTOMER IS RESPONSIBLE FOR SUBMITTING
SKYLIGHT DETAILS TO THE BUILDING AUTHORITY

01/24/2020

01/31/2020

3/5/2020
DATE:
TO ASSURE IT MEETS LOCAL BUILDING CODES.

/4"
23

AUTH:

NJK
WD

WD
HEX STAINLESS STEEL RUBBER GASKETS
SCREWS W/ RUBBER WASHIERS

DRAWN:
ISO

ML

ML

ML
ELEVATION

3 1/2"
SCALE: 1" = 1'-0"
WELD TO CONDENSATION
B107 TOP

REV:
MEET ANGLE GUTTER

4
2

6
3

5
1
RUBBER GASKETS
SION
EN
T DIM O
IGH DL
YL
SK
SILICONE SEAL

/8" 120°
13

4004 BOTTOM
RUBBER GASKETS
FOAM
5 TAPE
40 1/4"

1
3 3
1 1 3 HIP RAFTER
SCALE: 1' = 1'-0"
1 2 1
4004 BOTTOM
OUTSIDE CURB DIMENSION

1 1 1 RUBBER GASKETS
30"

EXAMPLE SKYLIGHT 6
OPP.

PROJECT ARCHITECT
SETTING
BLOCKS
2
140 1/2"

RIDGE

PROJECT ADRESS
4 4 SCALE: 1' = 1'-0"
30"

1 1 DLO 2" DLO DLO 2" DLO

EXTRUDED ALUMINUM
COVER
PRESSURE SNAP ON CAP PRESSURE SNAP ON CAP
BAR BAR
3 3

project name:
40 1/4"

3/8"
1 1 B107 TOP

architect:
location:
5 RUBBER GASKETS B107 TOP
30° RUBBER GASKETS
1
SET SCREW
ZINC PLATED 3/8"
DIAMETER HILTI KWIK
CONTINUOUS HUS-EZ ANCHORS AT

CUSTOMER
40 1/4" 40 1/4" EXTRUDED ALUMINUM 12" O.C. EMBED =
SWIVEL FRAME 2.125" SEE NOTE 2
4004 BOTTOM 4004 BOTTOM
80 1/2" WEEP HOLE RUBBER GASKETS RUBBER GASKETS
OUTSIDE CURB DIMENSION

LOGO
2 1/2"
CONDENSATION CONDENSATION

2"
SILICONE SEALED GUTTER GUTTER
ELEVATION A BEFORE SCREW FIXED
SCALE: 1/2" = 1'-0" SEALANT & TO CUB EXTRUDED ALUM. EXTRUDED ALUM.
3 1/2"

BACKER ROD FLASHING


END RAFTER END RAFTER
46 BY OTHERS
5/8
"
30 7/16"

1/4"

2 1/2"
5 RAFTER
30°

SCALE: 1' = 1'-0"


CURB DETAIL DESIGN OUTSIDE CURB DIMESION
BY OTHERS
80 1/2"
OUTSIDE CURB DIMENSION STRUCTURAL HIP RIDGE - A
1 EAVE ON CURB 4 RAFTER
SCALE: 1' = 1'-0" SCALE: 1' = 1'-0" 1page: 2
of:
GENERAL NOTES
1) ALUMINUM SKYLIGHT "B" TO BE GAMCO CURB MOUNT STEEL HIP RIDGE SKYLIGHT SYSTEM W/
1/4" GLAZING
ARCHITECTURAL
FINISH: GALVANIZED STEEL FRAME
COMMUNICATION
AND DESIGN
2) ALL GLASS TO BE 1/4" ROUGH WIRE GLASS
231 E. 2100 S. SUITE 200
SALT LAKE CITY, UT 84115
3) THE SKYLIGHT FRAME WILL BE DELIVERED TO THE JOB SITE FULLY ASSEMBLED WITH SCREENS. THE 800-658-8780, 801-298-9700
www.windowdraftsman.com
GLASS WILL BE DELIVERED IN A BOX. GLAZING AND INSTALLATION BY GAMCO INSTALLERS.

THESE DRAWINGS AND DESIGNS ARE THE


INTERPRETATION OF ARCHITECTURAL
THE ESTIMATED WEIGHT OF THIS SKYLIGHT SYSTEM COMMUNICATION AND DESIGN AS GIVEN BY
WITH GLASS IS 295 LBS. STRUCTURAL THE GLAZING CONTRACTOR, ANY AND ALL
LIABILITY PERTAINING TO THIS PROJECT LIES
ANALYSIS OF CURB, ROOF AND WALL SYSTEM BY SOLELY WITH THE GLAZING CONTRACTOR.
OTHERS. CURB MUST BE DESIGNED TO ACCOMMODATE
LATERAL LOADS OF SKYLIGHT SYSTEM. SUBSTRATE
TO WHICH THE SKYLIGHT SYSTEM WILL BE ANCHORED
MUST BE OF ADEQUATE STRENGTH AND MUST BE DRAWN: AUTH: DATE:
ALIGNED IN SUCH A CONFIGURATION AS TO MEET
ELEVATION ISO ALL GENERALLY ACCEPTED COMMERCIAL TOLERANCES. ML WD 1/3/2020
SCALE: 1 1/2" = 1'-0" THE CUSTOMER IS RESPONSIBLE FOR SUBMITTING
SKYLIGHT DETAILS TO THE BUILDING AUTHORITY
TO ASSURE IT MEETS LOCAL BUILDING CODES.

01/24/2020

01/31/2020

3/5/2020
DATE:
AUTH:
56"

NJK
WD

WD
DRAWN:
ML

ML

ML
"
1/8
31

REV:

4
2

6
3

5
1
12 GAUGE STEEL
3/8" STEEL ROD CASE FRAME WIRE 1" X 1" PATTERN
44"

WIRED TOGETHER WITH 12


GAUGE WIRE

3/8" STEEL ROD WRAPPED WITH 12 GA. 1" X 1" WIRE 22" 3/8" STEEL ROD
GAGE FRAME

1/4"
4"

"
3/4
7
OUTSIDE CURB DIMENSION

2 1"

EXAMPLE SKYLIGHT 6
8

PROJECT ARCHITECT
NEUTRAL CLEAR SILICON
18"

1 7/16"

PROJECT ADRESS
1/4" ROUGH WIRED GLASS
36"

6 2" 1/4" ROUGH WIRE GLASS

2
18"

1/2
"

440 5/16" X 1/2" BUTYL TAPE 2"

project name:
18" 12" 18"

V.I.F.

architect:
1/8" ALUMINUM

location:
SUPPORT ANGLE W/

6 MECHANICALLY

2"
48"
OUTSIDE CURB DIMENSION
HIP RAFTER 2"
FASTENED (OPTION)

SCALE: 1' = 1'-0"

CUSTOMER
ELEVATION B
SCALE: 3/4" = 1'-0"
3"

LOGO
1/4"
INSIDE FRAME BY
NEUTRAL CLEAR SILICON GENERAL CONTRACTOR
1 7/16"

4"
1/4" ROUGH WIRE GLASS 2" S.S. HEX-SCREW W/
2"
30°

NEO WASHER ±18" O.C.


1/4"

440 5/16" X 1/2" BUTYL TAPE


48"
1" 1" 3/4
"
STEEL HIP RIDGE - B

7 RAFTER
8 EAVE ON CURB
SCALE: 1' = 1'-0" 1/2" 2page: 2
SCALE: 1' = 1'-0" of: