P.E.C., Code of Ethics Supplementary Problems/ Questions
P.E.C., Code of Ethics Supplementary Problems/ Questions
32. Branch circuit larger than ______ Amp shall supply only 43. The residual voltage of a capacitor shall be reduced to
non-lighting outlet load. ______ Volts, nominal, or less with ______ minute/s after the
A. 50 C. 20 capacitor is disconnected from the source of supply.
A. 0, 0.5 C. 30,3
B. 30 D. 15 B. 15, 2 D. 50, 1
33. What is the distance from the flooring to the receptacle outlet
in dwelling unit in mm? 44. Equipment for hazardous locations shall be approved for the
A. 1800 C. 1700 following property,
B. 3700 D. 4000 EXCEPT
A. durability C. combustibility
B. ignitability D. explosibility
45. What is the minimum ampacity of supply feeder for a B. grounded conductor D. grounding
window type air conditioning unit with 8 Amp rated load electrode
current with other load supplied?
55. Which of the following is not accepted as if they have the
A. 15 Amp same meaning?
C. 12 Amp A. low voltage C. over voltage
B. 20 Amp B. no voltage D. under voltage
D. 10 Amp
56. What is called an electrically operated switch rated in
46. The primary winding of a step down transformer shall be amperes but also provide overload protection for motors?
protected on the primary side by an overcurrent device A. Magnetic starter C. Safety switch
rated NOT more than a certain percentage of the primary B. Magnetic contactor D. Manual starter
current. 57. Code of Ethics is Resolution NO. _____ series of 1995.
What is this percentage? A. 18 C. 22
A. 110% B. 23 D. 19
C. 125%
58. Which of the following establishes ethical behavior among
B. B. 135% professionals?
D. 150% A. legal contracts C. Hippocratic
oath
47. Where transformer vault is to be constructed with other B. taxation regulations D. rules of play
buildings below it, the minimum requirement for fire sports
resistance rating is ______ hours.
A. 4 C.2 59. Sec.7, Article III, R.A. 7920: An Electrical Engineer shall not
B. 1 ½ D.3 _______, vilify, or destroy the good name and reputation of
others.
48. Ferro resonance is destructive phenomenon associated with? A. modify C. compete
A. distribution transformer ` C. capacitor B. divulge D. malign
B. distribution line D. transmission 60. Integral part of contract requirement which set forth technical
line engineering requirements which are not shown completely on
drawing.
49. P.E.C. requires that the minimum area exposed surface A. specification C. notarization
affected by a plate electrode is: B. permit D. perfection
A. 1/6 sq. mts C. 1/5 sq. mts
B. 1/4 sq. mts D. 1/3 sq. mts
50. A ground ring encircling the building or structure, in direct
contact with the earth, consisting of at least 6,000 mm of bare
copper conductor not smaller than ______ mm2.
A. 30 C. 80
B. 50 D. 25
51. Grounding shall NOT be connected to_______.
A. exothermic welding C. soldered
fittings
B. listed clamps D. listed pressure
connectors