REVERSE OSMOSIS

SYSTEM
OPERATION MANUAL

SMN-3000
OPERATION AND MAINTENANCE MANUAL

INDEX

● Index………………………………………………..…………………….1

● RO main system specification and instruction………...........................….2

● Main system flow chart……………………………………............……...3

● Electric cabinet operation panel schematic diagram..............................….4

● Reverse osmosis system operation………………………................…….6-8

● TDS monitor operation manual……………………………….............…9-11

● Membrane element……………………………...……………………..12

1
RO MAIN SYSTEM SPECIFICATION AND INSTRUCTION

Feed Water Quality Requirement

INLET Water Quality


1. TDS< 1500PPM (recommendatory) 5. Turbidity<3TUN

2. Fe< 0.1PPM 6. PH: 5~8.5

3. Free Chlorine 7. Temperature: 20~35℃

4. Total Hardness< 200PPM 8. Operation: 24Hours/Day

OUTLET Water Quality


1. TDS< 25PPM

2. Conductivity < 50μS/cm

● SPECIFICATION

Model SMN-1500 SMN-2600 SMN-3000 SMN-3000A SMN-5000 SMN-6000 SMN-8000 SMN-12000

Pure-Water
1500GPD 2600GPD 3000GPD 4500GPD 5000GPD 6000GPD 8000GPD 12000GPD
Out-put

RO-Membrane 4040*1 4040LP*1 4040*2 4040*2 4040LP*3 4040*4 4040-2*3 4040-2*4

Pump Power 1.5KW 2.2KW 2.2KW 3.0KW

Recovery 25% 40% 40% 45% 45% 45% 45% 60%

Filter 20″PP 1μ & CTO Option: 0.1, 0.2, 0.45μm PP

Inlet Dia 3/4″,1″

Flow Meter RO Permeate & RO Concentrate

Display Total Dissolved Solids (TDS) PPM

Voltage 110V-240V, 50/60HZ, 1PHASE 380V 50/60HZ 3PHASE

Controller Semi-automatic control

Pressure Source-Inlet & RO Concentrate

2
Gauge

Dimension

(L*W*H cm)

MAIN SYSTEM FLOW CHART

MODEL:,SMN-3000

RO SYSTEM STRUCTURE AND SPARE PARTS SPECIFICATION

ITEM DESCRIPTION REMARKS


1 Water intake
2 PP Membrane Filter
3 CTO Membrane Filter
4 Inlet Water Pressure Meter
5 Low Pressure Switch
6 Inlet water Solenoid Valve
7 High Pressure Pump
8 Stainless Steel Pressure regulating valve
9 R.O Pre - membrane pressure Meter
10 Stainless Steel Check Valve
11 R.O Vessel & R.O Membrane
12 R.O Pemrmeate Flow Meter
13 Drain Valve(Pressure regulator)
14 Flush Drain Solenoid Valve

3
15 R.O Concentrate Drain Flow Meter

4
Electric cabinet operation panel schematic diagram

5
NOTICE BEFORE INSTALLATION

1. Make sure the assembling of all pipes for feed water, product water and drainage water are
connected.
2. The power source should be all coincided with the voltage ,phase,frequency and electric
current of this system
3. This system is automatically controlled. Please do not operate it without technicians

The external power supply connection diagram(220V 60Hz)

6
REVERSE OSMOSIS SYSTEM OPERATION
1. EQUIPMENT INSTALL
(1) Equipment must be ground;
(2) Connect raw water and backwash water;
(3) Connect permeate water pipe and concentrate water pipe;
(4) Install notice:
⊙ Make sure overstep 0.5m between equipment to wall;
⊙ Make sure the pressure of backwash water must same as the pressure of raw water
when machine work;
2. Working step
(1) Ordinal put the PP filter and CTO filter

(2) Adjust low pressure switch(The factory is set to 0.5 kg,customer no adjustment
of).

7
(3) Install the RO membrane housing to the system
⊙Uninstall membrane shell card pad and screw

⊙Take out the membrane shell plate

⊙Install the RO membrane

8
3. Generator’s maintenance
⊙User must change activated carbon cartridge and PP cartridge when input pressure
reading is high;
⊙If equipment stop working for long time, please cleaning machine:
(1) Use acid liquid (PH=2~4) to cleaning machine (RO membrane) for 1~2 hours;
(2) Use water to cleaning machine after drain water’s PH is same as raw water’s PH;
(3) Put 1% NaHSO3 liquid in machine, then close all valve;
⊙If alarm light or buzzer sound, please check raw water, usually the pressure of raw
water is too low.

CM-230ppm CONDUCTIVITY MONITOR OPERATION DIRECTIONS


9
10
11
12
BW-4040 Membrane Information

Permeate Flow Rate Stabilized Salt


Product Active Area ft2 (m2) Applied Pressure psig (bar)
gpd (m3/d) Rejection (%)
BW-4040 78 (7.5) 225 (15.5) 2,500 (9.5) 99.5

1. Permeate flow and salt rejection based on the following test conditions: 2,000 ppm NaCl, water temprature specified above 77°F (25°C)
and 15% recovery.
2. Permeate flows for individual elements may vary +/-15%.
3.The lowest stabilized salt rejection is 99.0%
4. For the purpose of improvement, specifications may be updated periodically.

Dimensions – Inches (mm) 1 inch = 25.4 mm


Product A B C D
BW-4040 40.0 (1,016) 1.05 (26.7) 0.75 (19.1) 3.94 (100.1)

Operating Limits
• Membrane Type Polyamide Thin-Film Composite
• Maximum Operating Temperature 113°F (45°C)
• Maximum Operating Pressure 600 psig (41 bar)
• Maximum Feed Flow Rate - 4040 elements , 14 gpm (3.2 m3/h)
• Maximum Pressure Drop 15 psig (1.0 bar)
• pH Range, Continuous Operation 3 – 10
• pH Range, Chemical Cleaning 2– 11
• Maximum Feed Silt Density Index (SDI) SDI <5
• Free Chlorine Tolerance <0.1 ppm