EMP-3000 Color Doppler Diagnostic Ultrasound System

Technical Specification

SYSTEM CONFIGURATION

Display Orthopedics Knob


21.5/23.8" LED HD screen Small Part Freeze Key
Flicker-Free Vascular Integrated Speakers
Screen Saver: Time adjustable Transcranial Doppler
Contrast & Brightness adjustable Neurology I/O interface
Screen Saver: Time adjustable Probe Plug Switch
Angle Adjustable Control Panel Extension Port
Switch Button Probe Connector: 3
Software Package Alphanumeric Keys DICOM 3.0
Abdomen Imaging Mode Area USB 2.0 port: 4
Cardiology Gain Control S-Video
Obstetrics Function Keys RS232
Gynecology User-Defined Keys Parallel Port
Urology 8 segment TGC & LGC VGA Output
Fetal Cardiology Trackball AUDIO Input/output
Musculoskeletal Backlit Keyboard VEDIO Input/output

GENERAL SPECIFICATION

Dimensions and Weight i. Environmental temperature range: +5℃ ~+40℃


Length: 990mm ii. Relative humidity range: ≤80%
Width: 690 mm iii. Atmospheric pressure range: 700hPa~1060hPa
Height:1200 mm
Net Weight: 65.0kg Transportation
Environmental temperature range: —40℃ ~+55℃
Power Supply Relative humidity range: ≤95%
Input Voltage: AC 100V-240V, 1.5A(Max),60Hz/50Hz Atmospheric pressure range: 500hPa~1060hPa
Input Power: 200 VA
Frequency: 60Hz/50Hz Storage
Continuous Working Time ≥8h Environmental temperature range: —20℃ ~+40℃
Relative humidity range: ≤80%
Operation Conditions Atmospheric pressure range: 500hPa~1060hPa

SHENZHEN EMPEROR ELECTRONIC TECHNOLOGY CO., LTD


Address:2&3F, Building 15, No.1008 Songbai Road Nanshan District, Shenzhen, 518108, China 1/4
TRANSDUCER INFORMATION

Probe Type Frequency Range(MHz) Elements


3.5CVSC
2.0MHz~5.0MHz 128
Single Crystal Convex Probe
3.5CV
2.0MHz~6.0MHz 128
Convex Probe
7.5LVS
5.0MHz~12.0MHz 128
Linear Probe
6.5VMC
4.5MHz~10.0MHz 128
Endocavity Probe
3.5MC
2.5MHz~5.0MHz 96
Micro-Convex Probe
6.5MC
5.0MHz~10.0MHz 80
Micro-Convex Probe
30P16NM
2.0MHz~5.0MHz 64
Phased Array Probe
50P10NM
3.0MHz~8.0MHz 64
High Frequency Phased Array Probe

IMAGE MODE

B / 2B / 4B / M / B+M Power Doppler Imaging PDI


Anatomic M Mode CMF / PDI / B+PW simultaneously
Color Flow Mapping CFM B+CFM+PW / B+PDI+PW Triplex Mode
Pulse Wave Doppler PW Continues Wave Doppler CW

IMAGING FEATURES

THI Tissue Harmonic Imaging Depth


TSI Tissue Specific Imaging MBP
eSCI Space Compound Imaging THI
eFCI Frequency Compound Imaging Scan Angle
ePure Unique Speckle Reduction Space Compound
eSpeed Auto Optimization Freq. Compound
eView Panoramic Imaging Chroma
eHelper – Basic ultrasound scan education software* Dynamic Range
Trapezoid imaging Frequency: (Probe dependent)
Needle enhancement for Ultrasound-Guided Biopsy Steer
Slant Scanning for Linear Probes (B Steer) TP-View (trapezoid)
Auto Breast Tumor Detection Technology EAI EFVI
Basic Elastography TSI
Auto Trace Calculation Line Density
Auto IMT Calculation Edge Enhance
Focus number
2D Mode Polarity
Gain Noise Reject

SHENZHEN EMPEROR ELECTRONIC TECHNOLOGY CO., LTD


Address:2&3F, Building 15, No.1008 Songbai Road Nanshan District, Shenzhen, 518108, China 2/4
Rotation Flow Opt:
Frame average Scan Line
Line average B/C
Smooth 2D+2D/CFM
Gamma Background Hide
ePure Color Hide
Gray Transition Persistence
Global Zoom Threshold
Picture in Picture Color Reject
Gray Rejection Smooth
TGC & LGC Artifact
Image reverse Direction PDI

M Mode PW Mode
Gain Gain
Speed Noise Threshold
Time Mark SV Length
Line average Correction angle
Smooth Fast Angle Adjustment
Chroma Scale
Anatomical M Baseline
Display Format: Wall Filter
Left B and right M Doppler Freq.
Up B and down M Spectrum Speed
Full screen M Dynamic Range
Steer
CFM/PDI Mode HPRF
CFM/PDI Gain Sound
Baseline Simult
Wall Filter Time Mark
Color Line Density Auto Calculate
Sensitivity Time Resolution
Doppler Freq. Trace-type
CFM/PDI Map Trace-Direction
Steer Trace Threshold
Simult Trace-Smooth
Color Invert Display Format: V2:1, V1:2, V1:1, H1:1, FULL
Color Focus (V: vertical, H: horizontal, L: left)

SYSTEM INTERFACE

Text Direction
Lexicon of comment for all exam types Shape
User-Defined Item Size
Font Size Color
Font Color

Arrow Body Mark

SHENZHEN EMPEROR ELECTRONIC TECHNOLOGY CO., LTD


Address:2&3F, Building 15, No.1008 Songbai Road Nanshan District, Shenzhen, 518108, China 3/4
Applications: Small Part
Abdomen Vessel
Obstetrics Orthopedic Surgery
Gynecology and Others
Urology 123 body marks with probe location
Cardiology Size: Big, Mid, Small.
PATIENT DATA MANAGEMENT SYSTEM

Detailed patient information Video storage format: AVI/CINE


Diagnostic image or video Video replay: Grey scale ≥1024frames
Editable Patient Report PW replay ≥ 100seconds, manually adjustable speed
Read/ Delete/ Save/ Export patient data DICOM 3.0.
Image storage format: BMP/JPEG/EMP Storage: HDD 1TB