Fire Exit Section
Fire Exit Section
Fire Exit Section
2
THE SEPARATION SHALL HAVE AT
LEAST TWO (2) HOUR FIRE
3.00
RESISTANCE RATING WHEN THE EXIT
CONNECTS FOUR (4) STOREYS OR
MORE, WETHER ABOVE OR BELOW THE
FLOOR DISCHARGE. IT SHALL BE
CONSTRUCTED OF NON COMBUSTIBLE 60
59
MATERIALS AND SHALL BE SUPPORTED 58 SAFETY HANDRAILS
57
BY CONSTRUCTION HAVING AT LEAST 56
55
TWO (2) HOUR FIRE RESISTANCE 53
54
RATING 51
52
3.00
50
49
48
THE MINIMUM HEADROOM SHALL NOT 47
46
45
BE LESS THAN TWO METERS (2m) 44
43
FROM THE FLOOR 42
41
12.00
40
DOORS SHALL NOT OPEN DIRECTLY 38
39 0.15m THICK FIRE WALL
37
ONTO A STAIR WITHOUT A LANDING. 36 AS REQUIRED FOR A 2
35
THE LANDING SHALL HAVE A WIDTH 34 HOUR FIRE RESISTANCE
33
NOT LESS THAN THE WIDTH OF THE
32 FOR FOUR STOREY
31
3.00
DOOR.
30
29
STRUCTURE
28
27
26
25
24
ALL STAIRWAYS DESIGNATED AS THE 23
22
MEANS OF EGRESS SHALL BE 21
20
CONTINUOUS FROM THE UPPERMOST 18
19
17
FLOOR LEVEL DOWN TO THE GROUND 16
15
FLOOR 14
12
13 0.125m DEPTH OF
11 0.30 CONCRETE SLAB AS
3.00
0.15
THE LOWEST POINT BY BARRIERS 5
4 CONCRETE SLAB
HAVING 2 HOUR FIRE RESISTANCE
0.90
3
2 REQUIRED FOR A FOUR
RATINGS WHERE VESTIBULES IS USED, IT 1
STOREY STRUCTURE
SHALL BE WITHIN THE 2-HOUR RATED
ENCLOSURE AND SHALL BE CONSIDERED
PART OF THE SMOKEPROOF ENCLOSURE
1
MACKENZIE M. REALCE FIRE EXIT
TECHNOLOGICAL INSTITUTE
COURSE/ SECTION: INSTRUCTOR
OF THE PHILIPPINES AR 341 - ARCH31S3 ARCH. PABLO, RAUL