1310 GEIC TEN AR SS1 100 - Substation AR SS1 100

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

D C B A THIS SITE

21700

N
7 4 7 4
1 2 1 2

N
AR-SS1-100 AR-SS1-100 AR-SS1-100 AR-SS1-100 150 7300 7400 6800 150

DN

DN
DN

DN
+5.90 TOP PAINTED PLAIN CEMENT COLORED GRC PANEL
7500 7500 PLASTER FINISH KAHARAMAA LOGO

DN
DN

DN

DN

DN
DN

DN

DN
900 400
+5.50 TOP +5.50 TOP +5.50 TOP

DN

DN

DN

DN
DN

DN
1300
150 7300 150 150 7300 150 +4.75 FFL
+4.60 SSL

+5.50 TOP +5.90 TOP


GSP GSP
1 1 D
150

150
UP 04
D D
A 1
2
A 01 01

5900
1500
3

3900
D 450
4 02

4600
D
03

900 450
+5.50 TOP +5.50 TOP
800

650
+0.70 FFL
LV ROOM

700
6800

6800
6600x7100 D
2000

04 ±0.00 ROAD LEVEL


GF-03
F3 S1 W3 C3 +0.40m FFL

+5.90 TOP
800

3 FRONT ELEVATION
1900 800 1600 800 2000 AR-SS1-100 SCALE 1:100 M
1500

D
B 03
B
+5.50 TOP
1500

A B C D
ROOF DECK
5 GSP 3 5 RD-01 3 21700
800

2
AR-SS1-100 TRANSFORMER FUTURE TX AR-SS1-100 AR-SS1-100 F5 _ W4 _
AR-SS1-100
ROOM 01
D
+4.75m FFL 150 6800 7400 7300 150
7200x7100 +4.60m SSL
7400

7400
2600

COLORED GRC PANEL PAINTED PLAIN CEMENT


21700

21700
GSP GF-02 +5.90 TOP
2 KAHARAMAA LOGO PLASTER FINISH
F3 _ W3 C3

900 400
+5.50 TOP +5.50 TOP +5.50 TOP
8 8 8 8

1300
+0.55m FFL +4.75 FFL
AR-SS1-100 AR-SS1-100 AR-SS1-100 AR-SS1-100 +4.60 SSL
+5.90 TOP
800

GSP TX-1
2
D GSP GSP GSP
4000 3100 01 +5.90 TOP 2 2 2
1500

5900
450

3900

4600
C C
800 500

995

900 450
D
03
650
GSP +0.70 FFL
1 +5.50 TOP

700
±0.00 ROAD LEVEL
1500 1000 4600
7300

7300

GF-01
REAR ELEVATION
GSP
F3 S1 W3 C3 1
5
5800

MV ROOM AR-SS1-100 SCALE 1:100 M


7100x7100
+0.70m D
FFL
02
THIS DRAWING IS THE PROPERTY OF G.E.I.C.
AND SHALL NOT BE COPIED OR REPRODUCED

3000
4
+5.50 TOP 2 1 1 2 IN ANY MANNER WITHOUT THEIR WRITTEN CONSENT.
700

3
2

D D
150

150

1
UP 7500 7500
GSP GSP +5.90 TOP +5.90 TOP
1 1
150 7300 150 150 7300 150
ARCHITECTURAL
COLORED GRC PANEL PAINTED PLAIN PAINTED PLAIN
+5.90 TOP +5.90 TOP
7 6 7 6 KAHARAMAA LOGO CEMENT PLASTER CEMENT PLASTER

900 400

900 400
FINISH FINISH
AR-SS1-100 AR-SS1-100 AR-SS1-100 AR-SS1-100

1300

1300
+4.75 FFL +4.75 FFL
+4.60 SSL +4.60 SSL

GSP GSP
TENDER
1 FLOOR PLAN 2 ROOF PLAN 1 1

AR-SS1-100 SCALE 1:100 M AR-SS1-100 SCALE 1:100 M

5900

5900
3900

3900
450 450

4600

4600
SUBSTATION-1

900 450

900 450
KAHRAMAA NOTES: 650 650
+0.70 FFL +0.70 FFL

700

700
1. CRANE & CABLE ACCESS TO BE AVAILABLE ALWAYS. ±0.00 ROAD LEVEL ±0.00 ROAD LEVEL

COLORED GRC PANEL


2. NO SERVICES INSIDE SUBSTATION. KAHARAMAA LOGO

3. NO BASEMENT UNDER SUBSTATION.


4 RIGHT ELEVATION 6 LEFT ELEVATION
AR-SS1-100 SCALE 1:100 M AR-SS1-100 SCALE 1:100 M

4. MV ROOM FLOOR FINISH TO BE EPOXY COATED


50mm THK. LIME STONE GRAVEL
1000UV TERRAM SEPERATING LAYER
5. FINISHED FLOOR LEVEL TO BE VERY SMOOTH AND THE TOLERANCE 50mm THICK EXTRUDED POLYSTYRENE THERMAL INSULATION
4mm THICK SBS 200g/m2 POLYESTERENE REINFORCED
NOT TO BE MORE THAN (±3mm) MAX. MEMBRANE WATER PROOFING
2 COATS OF LEQUED BITUMINE PRIMER
A B LIGHT WEIGHT SECREED TO ALL FALL 1:100 SLOP
RCC STRUCTURAL ROOF SLAB
C D 1 2
(REFER TO STRUC. DWG)
6. CONSULTANT(NOT CONTRACTOR) TO CONTACT KAHRAMAA CIVIL UNIT
21700 7500
BEFORE STARTING THE CONSTRUCTION OF SUBSTATION WITH
ORIGINAL APPROVED DRAWINGS(COPIES ARE NOT ACCEPTED)FOR 100 6800 7400 7300 100 100 7300 100
GETTING PERMISSION FROM KM TO SUPERVISE ALL CONSTRUCTION +5.90 TOP
600 20.MM CEMENT PLASTER IN 800 20.MM CEMENT PLASTER IN 800 20.MM CEMENT PLASTER IN 600 +5.90 TOP
600 20.MM CEMENT PLASTER IN 600
2 COATS OIL BASED FINISH 2 COATS SILK ACRYLIC 2 COATS OIL BASED 2 COATS SILK ACRYLIC
900 400

900 400

900 400
STAGES OF SUBSTATION,(FORM OF CONSULTANT SUPERVISION OF +5.50 TOP EMULSION PAINT FINISH SURFACE +5.50 TOP +5.50 TOP EMULSION PAINT FINISH
1300

1300
CONSTRUCTION TO BE USED IN THIS REGARD). +4.75 FFL +4.75 FFL
+4.60 SSL +4.60 SSL

7. SUBSTATION ROOM'S HEIGHT IS (3.65m) MINIMUM. GSP


1
PROPOSED CONTAINER CITY AT BU JOOD
D
8. UNDERTAKING OF RESPONSIBILITY OF THE STRUCTURAL DESIGN IS
5900

5900
03
GSP
3900

3900
D D D D
TO BE SUBMITTED TO KM AT BP STAGE. PLEASE REFER TO BP 1

3700
04 01 01 D 02
BU JOOD - QATAR
4600

4600

4600
D
3700

03
APPLICATION FORM. 03 MV TRANSFORMER D
LV ROOM TRANSFORMER ROOM ROOM 01
+1.10
ROOM
9. ELEVATION DRAWINGS TO BE SUBMITTED TO KM BEFORE STARTING +0.70 FFL 700
187
800 +0.70 FFL
4000 3000 100 CONTINENTAL TRADING CO. W.L.L.
THE CONSTRUCTION OF THE SUBSTATION. +0.70 +0.70 +0.70 +0.70 +0.70
FFL FFL FFL FFL FFL
150

+0.55 FFL +0.55 FFL


700

700
±0.00 ROAD LEVEL ±0.00 ROAD LEVEL MARCH 2022
G1310
10. TX ROOM DETAILS TO BE DESIGNED AND CHECKED BY THE
CONSULTANT (IF THE TX IS DRY TYPE).
PLANS, ELEVATIONS & SECTIONS
11.ELEVATION OF THE SUBSTATION MUST BE MATCHING WITH THAT OF RCC SLAB TO STRUCTURAL DETAIL
BITUMINOUS COATING 2 LAYERS +
GRAVEL MUNCH 800 2600 800 DESERT FILL DRESSED WITH CONCRETE PLINTH AS PER STRUCTURAL DETAILS
THE MAIN BUILDING (DESIGN, COLOR, ETC.) OR THE BOUNDARY WALL. POLYETHYLENE SHEET 1000g (TYP.) CONCRETE PLINTH AS PER STRUCTURAL DETAILS 19mm CRUSHED STONE OF 10mm THK. GRAVEL MUNCH
75mm THK. BLINDING CONCRETE DESERT FILL DRESSED WITH CONCRETE PLINTH AS PER
19mm CRUSHED STONE OF 10mm THK. STRUCTURAL DETAILS
COMPACTED FILL (95% MPT) (TYP.)
1:100 on A1
12.NOTE FOR AMI PROVISIONING: ALL REQUIIRED PROVISIONING FOR 1310-GEIC-TEN-AR-SS1-100
AMI SHALL BE IMPLEMENTED AS PER AMENDMENT TO THE 7 LONGITUDINAL SECTION 8 CROSS1 SECTION SAL ZAKER AHMED ZAKER AHMED
REGULATIONS TITLED. [AMENDMENT TO THE REGULATION FOR THE AR-SS1-100 SCALE 1:100 M AR-SS1-100 SCALE 1:100 M
INSTALLATION OF ELECTRICAL WIRING TO ACCOMMODATE THE
ADVANCED METERING INFRASTRUCTURE(AMI)COMPONENTS
-ADDITIONAL FIELD REQUIREMENTS FOR AMI]

0 00-03-2022 SS1