Simplification of Isolation Product Selection Through Advanced Design GPT Industries
Simplification of Isolation Product Selection Through Advanced Design GPT Industries
Simplification of Isolation Product Selection Through Advanced Design GPT Industries
do not parallel each other and this bolt types must be assessed. Is the
is definitely one of those cases. gasket going into a raised face to raised
face flange with B7 bolts and 2H nuts
For “Size” the common practice would that are all in good condition? If so,
be to select the standard ANSI, API, the application is very straightforward
DIN, AU, etc. nominal pipe size. For and is relatively simple to select the
isolating purposes, more information proper isolation kit. If, the flanges are
would be required. The pipe schedule a raised face to RTJ (Ring Type Joint),
would be necessary as it is very important then this information must be supplied
to match the exact pipe inside diameter, to the gasket manufacturer as the sealing
not the nominal size. The reason this element may not land in a contact area
is important is to eliminate any voids of the mis-matched flanges and may not
where conductive particles could collect. seal. The sealing elements must land on
The system must be evaluated for the the raised surface of the raised face flange
potential for conductive particles whether and also on the “non-groove” portion
they might be from hot tapping the line of the RTJ. This can be challenging
to the formation of iron sulfide between especially in small diameter flanges, so
the reaction of sour gas, water and the it is necessary to work with the technical
carbon steel in the pipe (see image). group of the manufacturer of the isolation
This also helps minimize the potential gaskets to confirm the gasket type is
for cavitation and flange face erosion. compatible with the mis-matched flanges.
For “Temperature” all materials that the
isolation gasket is constructed of must
be rated to the maximum temperature
the application will experience. If one
of the components is rated to a lesser
temperature, the entire system is at
risk. Similar to temperature, but not
exactly the same conversation is “fire
safety”. If the pipeline is transporting
a flammable material, the isolation kit
should be rated for the temperatures
and duration that would be typically
experienced in a fire. The rationale is
that an isolation gasket that is not fire
safe in the event of a fire can leak and
feed the fire with flammable product.
IRON SULFIDE
Not only must the gasket be compatible
with mis-matched flanges, but it also must
be galvanically compatible with exotic
pipe/flange metallurgy. A GRE gasket
with a standard 316SS core for example
would need an Inconel 825 core if the
pipe/flange metallurgy was Inconel 825.
Another consideration for application is
the amount of available space to install
an isolation gasket. Many critical service
isolation gaskets are somewhere between
.260” (6.4mm) and .308” (7.8mm)thick.
Gaskets of this thickness can be difficult
to install when the available flange gap
is let’s say .200” (5mm) wide. This
can lead to damaged gaskets and flange
faces during the attempt to install.
with hot water or steam due to a process
or “Media”, there are multiple
F
called “hydrolysis” or the breaking of
nuances to contemplate. The chemical bonds by water molecules
general practitioner would simply (see image). If the media is a monomer
look up the chemical or chemicals ( low molecular weight molecule that
that would be in the pipe and look up the has a propensity to combine with
chemical compatibility with the isolating other low molecular weight molecules
gasket product. If the resulting value (in this case ester links) to create
was an “A” or “B” rating, then the gasket repeating chain molecules (the process
would likely be selected. The actual of polymerization)), then care must be
selection process is more involved as taken in the selection of isolating gasket
it is necessary to include any cleaning materials to prevent polymerization (see
or biocide agents and to determine the image). Another consideration for media
chemical compatibility with the isolation is determining if the media is a liquid or gas
gasket. It is also necessary to look up the and if it is a gas, what is the acceptability
temperature of the chemical and determine of permeation? The typical GRE gasket
not only the chemical compatibility at has poor permeation attributes. GRE is
that temperature, but to determine if the constructed of glass fibers and epoxy.
chemical is aqueous based and if so, The glass fibers are perfectly straight and
does that temperature cause the chemical give media (gas or liquid) the ability to
to revert to steam? If it does cause the move along the glass fibers and permeate
chemical to generate steam, then the from the gasket internal diameter (ID) to
compatibility of the isolation gasket the gasket outside diameter (see image).
must also be compared to steam or even GRE manufacturers have attempted to
hot water. The typical isolation gasket improve the permeation resistance of GRE
comprised of GRE (glass reinforced products, but have been unsuccessful
epoxy) is not chemically compatible due to the nature of glass fibers.
T
he “Pressure” aspect appears fairly The above STAMP process is what is normally
straightforward. If an isolating undertaken when selecting any type of gasket.
product is rated for up to 2500# When selecting an isolation gasket, the electrical
class use, then it is often that simple. isolation properties must also be taken into
Where it can become more delicate is when account of course. Again, this is not as simple
the temperature rating of the application is as it sounds. Many corrosion engineers use
near the upper range of the GRE material and/ a 500 volts per mil (VPM) rating as a “go/no
or the pressure range is near the top of the go” assessment for isolation products. This
rating. Glass reinforced epoxy products often 500 VPM rating can be acceptable or it could
have a glass transition temperature (Tg) that be an issue. Most GRE products have at least
can be approximately 50 degrees Fahrenheit a 500 VPM rating and in a dry condition are
or 10 degrees Celsius lower than the rated acceptable as an isolating product. Most GRE
operating temperature. At high pressures, products also have a good water absorption value
this combination can blow a GRE isolating (typically between .01% and .02%). However,
this is an ASTM D570 test and is simply an
product out due to the fact that the GRE is in
immersion in water with no pressurization.
a semi-solid state. When operating conditions
Many isolation gaskets will be isolation tested
for either temperature or pressure are nearing
prior to hydrotesting a pipeline and will pass the
maximum values, it is advisable to contact
test. However, after pressurizing the pipeline
the manufacture prior to using the GRE based
with water, the operator will find that an isolation
gasket. When pressure AND temperature are test after hydrotest can show very low resistivity
nearing the maximum ratings, do not install for the isolating gasket (see graph of Pre/
the product until contacting the manufacturer. Post Hydro). Additionally, there are isolation
gaskets that have excellent dielectric properties
Pressure does start to get complex when other in a dry state, but are constructed of hygroscopic
factors start to be considered. For example, meaning they absorb moisture. This is common
an isolating gasket may be rated to a certain for phenolic and fiber based isolation gaskets.
pressure when the proper torque, proper flange
conditions and application variables exist, As you can see, selecting the proper isolation
but when these items start to decay through gasket can be much more complex than one
improper installation or torque values, rotated would typically expect. This selection process
flanges or corroded flanges or thermal cycling, has been simplified by a new, patent pending
the pressure rating can also begin to decay. design for an isolating gasket. The design
Pressure can also disqualify a gasket selection does not include GRE, but is constructed
if the user has tight sealing considerations of a .125” (3.2mm) thick 316L stainless
due to the increase in permeation with steel core coated with a very high dielectric
increased pressure. A tighter sealing coating (1,800 VPM typical). The coating is
product may be required in these instances. extremely chemically and abrasion resistant.
THE DESIGN HAS A REDUNDANT SEALING SYSTEM
AND HAS SUCCESSFULLY PASSED API 6FB FIRE
STANDARDS IN MULTIPLE SIZES/CLASSES.
How does this new product simplify the STAMP gasket selection process?
For “Size” - The isolation gasket has been designed so that the retainer is the same
regardless of class. The only change necessary is the primary PTFE sealing element
width. The sealing element is machined to properly fit the pipe bore dimension after
compression. This reduces manufacturing time and shortens lead-time.
For “Temperature” – The materials of construction are all rated to at least 500°F(260°C)
and the Tg is higher than this value. The only consideration beyond the gasket for
temperature selection would be the sleeves and washers. The sleeves and washers should
be selected based on their temperature rating.
For “Application” – This design has successfully passed API 6FB in multiple sizes and
classes. The coated metal core, restructured PTFE and metallic C-ring yield virtually
no leakage and is excellent for pipelines that experience cycling applications as noted in
the API PR2 results below.
Emission results from Shell TAT (Type Approval Testing) are extremely favorable due
to the redundant seal design (see below results) the design passes the Type A Shell
approval value by approximately 1,000X:
For “Media” – The material combination of this design is rated for use in sour gas,
steam, hot water and many other chemicals that GRE based isolation gaskets are not
rated for. It is not prone to hydrolysis.
For “Pressure” – The product has been tested at high pressures and the lowest pressure
leakage was 28,000psi (1,930 bar) versus less than 15,000psi (1,034 bar) for metal cored
GRE isolation products. The seal design is a pressure activated seal, so as the pressure is
increased, the sealability is not significantly compromised and in some cases can improve.
Electrically, the new design has a typical dielectric value of 1,800 volts per mil and is
hydrophobic in nature (repels moisture).
As can be seen, this new design dramatically reduces the selection process complexities
and simplifies not only the selection process, but eliminates the need for various isolation
products in oil and gas pipelines.