1) The document defines floor to lot area ratio (FLAR) as the ratio of a building's gross floor area to the total lot area. FLAR is determined by dividing gross floor area by total lot area, and gross floor area cannot exceed the prescribed FLAR multiplied by the total lot area. 2) Gross floor area is defined as the total floor space within a building's perimeter walls, including mezzanine levels. It includes balconies but excludes covered parking, driveways, and uncovered areas like pools or rooftop decks. 3) Total gross floor area is defined as gross floor area plus all other enclosed and attached areas above or below grade, including covered parking and driveways.
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

Notes Ad

1) The document defines floor to lot area ratio (FLAR) as the ratio of a building's gross floor area to the total lot area. FLAR is determined by dividing gross floor area by total lot area, and gross floor area cannot exceed the prescribed FLAR multiplied by the total lot area. 2) Gross floor area is defined as the total floor space within a building's perimeter walls, including mezzanine levels. It includes balconies but excludes covered parking, driveways, and uncovered areas like pools or rooftop decks. 3) Total gross floor area is defined as gross floor area plus all other enclosed and attached areas above or below grade, including covered parking and driveways.
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

1) the Glossary section of the 2004 Revised Implementing Rules and Regulations (IRR) of P.D.

No. 1096, the 1977 National Building Code of the Philippines (NBCP) defines the FLOOR TO
LOT AREA RATIO (FLAR) or FLOOR AREA RATIO (FAR) as the ratio between the Gross
Floor Area (GFA) of a building/structure and the Total Lot Area (TLA) of the lot/property on
which it stands. The FLAR is determined by dividing the GFA of a building/structure by the
TLA. The GFA of any proposed or existing building/structure should not exceed the prescribed
FLAR multiplied by the TLA i.e. appearing on Table VII.G.1. Reference Table of Floor to Lot
Area Ratio (FLAR) Designations/ Rights of its Rule VII GUIDELINES ON BUILDING BULK,
DEVELOPMENT CONTROLS, BUILDINGS AND OTHER ACCESSORY STRUCTURES
WITHIN CEMETERIES AND MEMORIAL PARKS;
2) The same Rule VII Guidelines define the GFA as the total floor space within the perimeter of
the permanent external building walls (inclusive of main and auxiliary buildings) such as office
areas, residential areas, corridors, lobbies and mezzanine level/s. The GFA shall also include
building projections which may serve as floors or platforms that are directly connected
to/integrated with areas within the building/structure, e.g., balconies (Refer to Section 1004 of
Rule X of this IRR) and the GFA EXcludes the following: (a) COVERED AREAS used for
parking and driveways, services and utilities; (b) Vertical penetrations in parking floors where no
residential or office units are present; and (c) Uncovered areas for helipads, air-conditioning
cooling towers or air-conditioning condensing unit (ACCU) balconies, overhead water tanks,
roof decks, laundry areas and cages, wading or swimming pools, whirlpools or jacuzzis, terraces,
gardens, courts or plazas, balconies exceeding 10.00 sq. meters, fire escape structures and the
like. (emphases supplied)
Annotation: To properly exclude the generated basement floor area from the GFA, the applicable
clause should read as “COVERED AND ENCLOSED AREAS USED FOR PARKING x x x”
rather than just “COVERED AREAS used for parking x x x”. In the above provision of the Rule
VII Guidelines, the term COVERED AREAS is used to refer to basement levels. Additionally,
the term “driveways” must naturally encompass ramps which are effectively angled driveways.
3) The same Rule VII Guidelines define the TOTAL GFA (TGFA) as the the total floor space
within the main and auxiliary buildings primarily CONSISTING OF the GFA and ALL OTHER
ENCLOSED SUPPORT AREAS together with all other usable horizontal areas/surfaces above
AND BELOW ESTABLISHED GRADE LEVEL THAT ARE ALL PHYSICALLY
ATTACHED TO THE BUILDING/S which shall consists of the following: (a) COVERED
AREAS used for parking and driveways, services and utilities. The TGFA specifically excludes
provisions for courts above grade level; (b) Vertical penetrations in parking floors where no
residential or office units are present; (c) Uncovered areas for helipads, air-conditioning cooling
towers or ACCU balconies, overhead water tanks, roof decks, laundry areas and cages, wading
or swimming pools, whirlpool or jacuzzis, terraces, gardens, courts or plazas, balconies
exceeding 10.00 sq. meters, fire escape structures and the like; and (d) Other building projections
which may additionally function as floors or platforms if properly reinforced, e.g., the top
surfaces of roof extensions/eaves, sun-breakers, large roofed or cantilevered areas such as porte
cocheres, canopies and the like. (emphases supplied)
From the foregoing, it is clear that the GFA based on the direct application of the FAR EXcludes
the floor area generated at basement levels, if and only if such generated basement spaces are
exclusively used for parking and driveways (inclusive of ramps), services and utilities.
It is the Total GFA (NOT the GFA based on the direct application of the FAR) that INcludes the
floor area generated at basement levels. Thank You.