Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Olympus Au 640

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

AU 640

T H E V I S I B L E D I F F E R E N C E

C S L

L I N I C A L

H E M I S T R Y E D I U M

Y S T E M A R G E

F O R M L A B O R

A T O R I E S

A U 6 4 0 L

P A

F A

E O W

A B O R A T O R Y

E E D S

V A I L A B L E

Refrigerated reagent compartments


2 3 6

Washing station

Special coated mixers


1

Glass cuvettes

ISE unit
1

Sample probe
3

Sample feeder

Cooled STAT rotor


7

The Olympus AU 640 analyser system

Yo u r f u t u r e n e e d s were our challenge laboratories are in a changing phase from the past into the future. The need for top quality results is even more pressing whilst economic pressures constantly challenge lab budgets.

C urrent

that covers routine and S TAT t e s t i n g i n p a r a l l e l . A system which gives short turn around times and is still capable of performing high throughput workloads.

includes the ability to simplify all analytical stages with online predilution and incorporates quality checks, for example for lipaemia, icterus and haemolysis.

Optimised workflow is the key to the answer to these needs. Optimised workflow means workstation consolidation on a highly reliable system platform

A logical system that aids training of all staff so that the system can be used 24 hours per day by staff from a variety of backgrounds. A common user interface that means if you use one of our systems you can use them all.
workflow is not restricted to analysis, it

Last but not least your future system should be prepared for lab automation as an open platform.

Optimised

O T
O

U O

R U R

S E

W Q

E U

R E S T

The innovative Olympus AU 640 system platform technology perfectly matched to the state of the art reagents.

O L Y M P U S

n e s y s t e m f o r S TAT a n d r o u t i n e t e s t i n g iquid stable ready to use system reagents ou may run samples in rerun or reflex mode - its your choice odem control for support and troubleshooting robe crash prevention and clot detection nique high quality photometer design ample predilution for minimum hands on and maximum quality

A U

uto calibration - on the fly ser definable SW Interface under Windows NT

6 4

hundred, yes sixhundred tests per hour ISE capability m i n u t e s S TAT c a p a b i l i t y i n p a r a l l e l t o a t h r o u g h p u t o f u p t o 1 , 2 0 0 tests per hour

(zero) electromagnetic interference for 100% consistent results 24 hours per day

E I

M G H

T U

I A

M L

I I

S T

A T Y

N I A G

I
N

N O S

D
T

E I

T A C S

Optimum accuracy

Olympus spot photometry system

The unique Olympus spot photometer in combination with the interference free fibre optic data transfer system gives results which are unmatched in terms of accuracy and precision. Only the combination of both technologies enables the Olympus AU 640 to combine micro reaction volumes with high throughput. The result is a system unmatched in its ability to provide effective analysis that matches your organisation and budget needs.
Va l i d d i a g n o s t i c s

Wo r k s t a t i o n c o n s o l i dation to minimise overall hands on time as much as 51 different analytes which can be processed simultaneously and a throughput of up to 1200 results/hr the AU 640 is the real platform for workstation consolidation. Hands on time is further reduced when the system is operated in the AutoRerun mode. This user defined mode enables flexible rules to be applied to samples that require further study including Reflex tests or sample re-analysis with the same, reduced or even increased volume ensuring optimum analysis condition for that test. Carry over free high tech liquid handling system

W ith

AU 640 sample rack system, already prepared for future automation requests

Olympus AU 640 liquid handling components

A t Olympus we recognise the importance of producing valid results and interpreting these data accurately for your clinical colleagues. The AU 640 incorporates the ability to recognise interferences that may effect the validity of the data. This alone is not enough and that is why we at Olympus design total systems, a part of which is the design of reagents with advanced characteristics to reduce or eliminate the effect of interferents. The result is to remove hands on time and greatly improve e f f i c i e n c y.

T he combination of computer controlled pipetting speed and a highly efficient triple wash station eliminates any contamination. In addition to this the AU 640 includes clot detection and incorporates probe anti crash systems to avoid invalid test results.

T
A

O D E

G S

A I

I M

N P L

T
E

V
N D

I O

L M

E F O

D
R

F B

E L

R E

T A

can be loaded at any time on the same r o t o r, s a m p l e I D i s r e c o gnised via an internal bar c o d e r e a d e r. Trouble free maintenance maintenance requirements of the AU 640 are reduced to a minimum. This is the result of both hardware and software design being totally systemised with Olympus system reagent usage. The analyser software monitors functions and automates processes taking advantage of the unique benefits supported by the use of permanent cuvettes in the Olympus dry bath system. Our reagents are optimised for best performance on the new platform of Olympus analysers. Ease of use as maxim AU 640 user interface is designed to minimise any training requirements. The user is linked in all cases to a context specific help function within the AU 640 software. The users ability to define the format of the touch screen removes unwanted icons during routine, thus further e n h a n c i n g e f f i c i e n c y. support and troubleshooting are avail-

S TATs

able from the context related help screens and via modem from your support centre minimising the risk of down time. Olympus system reagents analytical unit itself is only one component of a system solution. Q u a l i t y, c o s t s a n d e a s e o f use are effected greatly by reagents as well. Therefore Olympus Diagnostica has developed a complete range of system reagents specially designed to match our new AU 400/600/640 system platform requirements. Over 90 different applications already available, additional tests are under development. Olympus system reagents are designed and manufactured under ISO 9001 certified processes for continuous quality improvement liquid stable for convenient handling ready to use to minimise handling errors barcoded for a positive reagent ID configured in pack sizes for differing usage requirements exhibit extended on board stability to avoid any waste

Refrigerated Olympus AU 640 STAT Rotor

The

T he

User definable touch screen monitor for even simpler use

T he

T he

Refrigerated Rotor f o r S TAT, Q C a n d Calibrations

The AU 640 holds up to 22 tubes in a refrigerated rotor enabling the system to run calibrations and QC in a user defined w a y d u r i n g t h e w h o l e d a y. Even auto calibration on the fly i.e. in case of reagent lot change is possible.

Technical

L Y

P P E

U C

S I F

S
I

Y C

S A

T L

R M

G C

E H

N E

T D

L Y

A T

OLYMPUS SYSTEM REAGENTS


Substrates Albumin Alpha Amylase Bicarbonate Bilirubin total Bilirubin direct Calcium Calcium Arsenazo Cholesterol Creatinine Glucose Glucose HK HDL-Cholesterol Iron LDL-Cholesterol Magnesium Phosphate Phospholipide Total Protein Triglycerides Urinary Protein UIBC Urea Uric Acid Homogeneous Immuno Assays Apo A1 Apo B ASL C3 C4 CRP IgA IgG IgM Ferritin RF Transferrin DAU Amphetamine Barbiturates Benzodiazepines Beta Blockers Cannabinoids Cocain Cotinine EDDP Methadone Methamphetamine Opiates PCP Thiazides Sample check Urine pH Enzymes ACP ALP CHE CK CK-MB GGT GOT (AST) GPT (ALT) HBDH LDH Lipase

The Olympus System Reagents an expanding range of reagents

ISE Chloride Potassium Sodium

Specific Proteins alpha-1-Antitrypsin alpha-1-Glycoprotein -2-Microglobulin Ceruloplasmin Haptoglobin Microalbumin Myoglobin Prealbumin

TDM Amikacin Carbamazepine Digitoxin Digoxin Gentamicin NAPA Phenytoin Phenobarbital Procanamid Theophylline Tobramycin Valproic Acid

Additional parameters are planned to be released in the coming month

O A R

L Y A N

M G

P E

S
F

S U

E S

M T O

S
M

U E

P R

R E

T R V

I C E

The combination of Olympus analysers and the specially matched Olympus System Reagents represent only a proportion of Olympus Diagnostica. Our commitment to the provision of a total system and the increasing demands of the modern major laboratory has led to the development of a comprehensive range of services.
Application consultancy

We p r o v i d e h e l p f o r r e q u e s t s c o n c e r n i n g r e a g e n t s o r o n how to conduct tests through our application specialists. In cases where an application problem cannot be solved over t h e t e l e p h o n e , w e g i v e d i r e c t a s s i s t a n c e i n y o u r l a b o r a t o r y.
Operator training specialists will teach you all the necessary basic knowledge about operation, application and user maintenance. In addition customised on-site training is of course available. Delivery service

Our

Y o u r o r d e r i s h a n d l e d b y u s i m m e d i a t e l y. R e a g e n t s delivery within 24 hours is possible and in true emergencies priority dispatch ensures the best possible delivery time.
Te c h n i c a l e q u i p m e n t s e r v i c e support team of field based engineers and specialists is further enhanced by expert telephone assistance from a specialist who can provide immediate advice on technical problems and how to get the best out of your Olympus system. Individual laboratory and contract concepts sales representative, assigned to you, will structure made-to-measure system solutions for you.

Our

The

AU 640 Specifications
Analytical system Analytical methods Fully automated, for routine, STAT, urine and homogeneous immunoassays Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE Simultaneously processed analytes Throughput Sample feeder 48 photometric tests, 51 with ISE 800 photometric tests/hour; maximum of 1,200 with ISE Racks with 10 samples each (bar codes on primary tubes and on racks); capacity of 150 samples; continuous loading Sample tubes In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm STAT samples Sample volume Reagent supply Reagent volume Total reaction volume Reaction cuvette Reaction time Reaction temperature Mixing method Photometry system Up to 22 positions for STAT samples, bar coded primary tubes 2 50 l in 1 l steps (1 50 l for repeats) 48 positions for R1 and R2; refrigerated (4 C 12 C) 1. reagent: 25 300 l; 2. reagent: 25 300 l; (in 1 l steps) 150 550 l Quartz cuvettes Up to 8 minutes, 40 seconds 37 C With rotating paddles after dispensing sample and reagent Direct assay through the reaction cuvette (0 2.5 OD) mono, bichromatic measurements possible Wavelength Cuvette cleaning Calibration Quality control Test requisition 13 different wavelengths between 340 800 nm Comprehensive cleaning with detergents Auto calibration, cooled calibrator positions Auto QC, cooled QC positions Individual and profile test requisition via on line, mouse, functions keys or touch screen Safety On-line Software Dimensions (W x H x D) mm Clot detection and crash prevention for sample and reagent dispenser Full uni- and bidirectional communication possible Windows-NT ANL 1,850 x 1,210 x 800; DPR 700 x 1,430 x 700

European Headquarters: OLYMPUS DIAGNOSTICA GmbH, Wendenstrae 14-16, D-20097 Hamburg, Tel. (0 40) 2 37 73-0, Fax (0 40) 2 37 73-7 83, http://www.olympus-diagnostica.com
OLYMPUS D.O.O.ZA TRGOVINU, Jurjevska 15, 10000 Zagreb/Croatia, Tel.: (385-1) 4899003, Fax: 420888 OLYMPUS AUSTRIA GmbH, Shuttleworthstrae 25, 1210 Vienna/Austria, Tel.: (43-1) 291010, Fax: 29101222 OLYMPUS DIAGNOSTICA GMBH (Irish Branch), Lismeehan, OCallaghans Mills, County Clare/Ireland, Tel.: (353-65) 6831100, Fax: 6831122 OLYMPUS C&S, V Jircharich 10, 11121 Prague 1/Czech Republic, Tel.: (420-2) 24917777, Fax: 2491-5080/-4234 OLYMPUS FRANCE, Silic 165, 74 rue dArcueil, 94533 Rungis-Cedex/France, Tel.: (33-1) 45602300, Fax: 46866562 OLYMPUS DIAGNOSTIC SYSTEMS (U.K.), Great Western Industrial Park, Dean Way, Southall, UBS 4SB UK, Tel.: (44-171) 250 4800, Fax: 250 4801 OLYMPUS ITALIA S.R.L., Via Modigliani 45, 20090 Segrate (Milano)/Italy, Tel.: (39-02) 269721, Fax: 26972488 OLYMPUS OPTICAL POLSKA Sp. z o.o., ul. Swietojerska 5/7, 00-236 Warszawa/Poland, Tel.: (48-22-831) 15 17, Fax: 04 53

You might also like