Lal Path Lab
Lal Path Lab
Lal Path Lab
Name : DUMMY
Lab No. : B0806 Age : 17 Years
Ref By : SELF Gender : Female
Collected : 31/3/2023 9:39:00AM Reported : 1/4/2023 4:30:12PM
A/c Status : P Report Status : Interim
Collected at : PRODUCTION TEST COLLECTION CENTRE Processed at : LPL-NATIONAL REFERENCE LAB
SECTOR - 18, BLOCK-E ROHINI National Reference laboratory, Block E,
DELHI 110085 Sector 18, Rohini, New Delhi -110085
Test Report
Interpretation
HbA1c result is suggestive of non diabetic adults (>=18 years)/ well controlled Diabetes in a known Diabetic
Interpretation as per American Diabetes Association (ADA) Guidelines
------------------------------------------------------------------------------------------
| Reference Group | Non diabetic | At risk | Diagnosing | Therapeutic goals |
| | adults >=18 years | (Prediabetes) | Diabetes | for glycemic control |
| ----------------|-------------------|---------------|-------------|----------------------|
| HbA1c in % | 4.0-5.6 | 5.7-6.4 | >= 6.5 | <7.0 |
------------------------------------------------------------------------------------------
Note: Presence of Hemoglobin variants and/or conditions that affect red cell turnover must be considered,
particularly when the HbA1C result does not correlate with the patient’s blood glucose levels.
---------------------------------------------------------------------------------
| FACTORS THAT INTERFERE WITH HbA1C | FACTORS THAT AFFECT INTERPRETATION |
| MEASUREMENT | OF HBA1C RESULTS |
|--------------------------------------|------------------------------------------|
| Hemoglobin variants,elevated fetal | Any condition that shortens erythrocyte |
| hemoglobin (HbF) and chemically | survival or decreases mean erythrocyte |
| modified derivatives of hemoglobin | age (e.g.,recovery from acute blood loss,|
| (e.g. carbamylated Hb in patients | hemolytic anemia, HbSS, HbCC, and HbSC) |
| with renal failure) can affect the | will falsely lower HbA1c test results |
| accuracy of HbA1c measurements | regardless of the assay method used.Iron |
| | deficiency anemia is associated with |
| | higher HbA1c |
---------------------------------------------------------------------------------
*B0806* Page 1 of 2
.
Name : DUMMY
Lab No. : B0806 Age : 17 Years
Ref By : SELF Gender : Female
Collected : 31/3/2023 9:39:00AM Reported : 1/4/2023 4:30:12PM
A/c Status : P Report Status : Interim
Collected at : PRODUCTION TEST COLLECTION CENTRE Processed at : LPL-NATIONAL REFERENCE LAB
SECTOR - 18, BLOCK-E ROHINI National Reference laboratory, Block E,
DELHI 110085 Sector 18, Rohini, New Delhi -110085
Test Report
IMPORTANT INSTRUCTIONS
ŸTest results released pertain to the specimen submitted .ŸAll test results are dependent on the quality of the sample received by the Laboratory .
ŸLaboratory investigations are only a tool to facilitate in arriving at a diagnosis and should be clinically correlated by the Referring Physician .ŸReport
delivery may be delayed due to unforeseen circumstances. Inconvenience is regretted .ŸCertain tests may require further testing at additional cost
for derivation of exact value. Kindly submit request within 72 hours post reporting.ŸTest results may show interlaboratory variations .ŸThe
Courts/Forum at Delhi shall have exclusive jurisdiction in all disputes /claims concerning the test(s) & or results of test(s).ŸTest results are not valid
for medico legal purposes.ŸThis is computer generated medical diagnostic report that has been validated by Authorized Medical
Practitioner/Doctor. ŸThe report does not need physical signature.
(#) Sample drawn from outside source.
If Test results are alarming or unexpected, client is advised to contact the Customer Care immediately for possible remedial action.
Tel: +91-11-49885050,Fax: - +91-11-2788-2134, E-mail: lalpathlabs@lalpathlabs.com
National Reference lab, Delhi, a CAP (7171001) Accredited, ISO 9001:2015 (FS60411) & ISO 27001:2013 (616691) Certified laboratory.
*B0806* Page 2 of 2