FWB Solenoid Valve Direct
FWB Solenoid Valve Direct
FWB Solenoid Valve Direct
FWB Series
NC (normally closed) type, NO (normally open) type
Port size: Rc1/8 to Rc1/2
Refer to Ending 17 for more details.
Individual specifications
Descriptions Max. working pressure Rated electric power (VA) Power consumption (W)
Orifice Cv flow differential MPa Max. working Rated Weight
Port size At holding At starting AC
(mm) factor pressure MPa voltage (kg)
Model no. AC DC 50Hz 60Hz 50Hz 60Hz 50/60Hz DC
NC (normally closed) type
FWB21 - 6 - Z 1 0.036 1.5 0.9
Rc 1/8 100 VAC 5 4 9 8 2.7/2 4 0.15
-2 2 0.15 0.7 0.35
1.5 50/60Hz
FWB31 - 68 - 3 3 0.31 0.8 0.5
Rc 1/8
-5 4 0.5 0.5 0.2 110 VAC 9.5 7 23 20 4/3.2 6 0.3
Rc 1/4
-6 5 0.65 0.3 0.08 60Hz
8 -5
FWB41 - 10 4 0.54 0.8 0.5
Rc 1/4 200 VAC
-6 5 0.8 0.5 0.25 50/60Hz
16 13 40 35 7.5/6.3 8 0.49
Rc 3/8
-7 7 1.1 0.2 0.1
0.3
FWB41 - 10
15 - 8
Rc 3/8
Rc 1/2 10 1.88 0.1 0.05 220 VAC
8 -5
FWB51 - 10 4 0.54 1.1 1.3 60Hz
Rc 1/4 1.5
-6 5 0.8 0.7 0.6 24 VDC 23 19 60 50 11.5/10 11.5 0.68
Rc 3/8
-7 7 1.1 0.3 0.25 12 VDC
0.3
FWB51 - 10
15 - 8
Rc 3/8
Rc 1/2 10 1.88 0.12 0.1 0.8
NO (normally open) type
FWB32 - 6 -3 3 0.31 0.4 0.4 100 VAC
8 Rc 1/8 50/60Hz
-5 4 0.5 0.2 0.2 11.5 8 25 22 4.6/3.2 6 0.31
Rc 1/4 110 VAC
-6 5 0.65 0.12 0.12 1.5
60Hz
8
FWB42 - 10 -5 4 0.54 0.4 0.4
Rc 1/4 200 VAC
-6 5 0.8 0.2 0.2 18 14 45 40 7.5/6.5 8 0.54
Rc 3/8 50/60Hz
-7 7 1.1 0.12 0.12 0.3 *3
8 220 VAC
FWB52 - 10 -5 4 0.54 0.7 0.7 60Hz
Rc 1/4 1.5
-6 5 0.8 0.45 0.45
24 VDC
25 20 60 50 11/10 11.5 0.71
Rc 3/8
-7 7 1.1 0.2 0.2 0.3 12 VDC
*1: Use the allowable voltage fluctuation range within 10% of the
Leakage current
Voltage
rated voltage. 100 VAC 200 VAC 24 VDC 12 VDC
*2: The leakage current must be less than values given at right. Model no.
*3: 8.5 (W) for 12 VDC. FWB2 3mA or less 1.5mA or less 1mA 2mA
FWB3/4/5 6mA or less 3mA or less or less or less
78
FWB Series
FWB*1 Series: NC (normally closed) type
How to order
F W B 2 1 6 Z O 2C B 1
HNB/G
Model no.
No. of port
F F F F F F F USB/G
(2 port valve) W W W W W W W
B B B B B B B
Working fluid 21 31 41 51 32 42 52 FAB/G
Symbol Descriptions
(Water)
A Size variation FGB/G
A Size variation 2 22 mm
3 28 mm FVB
4 34 mm
5 40 mm FWB/G
B Actuation
B Actuation 1 FHB
NC (normally closed) type
2 NO (normally open) type
FLB
C Port size
C Port size
6 Rc 1 / 8 AB
8 Rc 1 / 4
10 Rc 3 / 8 AG
15 Rc 1 / 2
D Orifice AP/AD
D Orifice
Z 1
*1 APK/
*2 2 2 ADK
3 3 For
5 4 dry air
6 5 Explosion
7 7 proof
8 10 HVB/
E Body, sealant combination HVL
E Body, sealant combination Body Sealant SAB/
*3 SVB
O Brass NBR
D Stainless steel NBR NP/NAP/
NVP
F Coil option
F Coil option 2C Standard Grommet lead wire CHB/G
*4
Grommet lead wire with
2CS
surge suppressor MXB/G
2G DIN terminal box (Pg11)
Other G.P.
DIN terminal box with light systems
2HS
Option
: Body - brass, sealant - NBR H Voltage 1 100 VAC 50/60Hz, 110 VAC 60Hz
F Coil option : Grommet lead wire *5
2 200 VAC 50/60Hz, 220 VAC 60Hz
G Other options : Mounting plate
3 24 VDC
H Voltage : 100 VAC 50/60Hz, 110 VAC 60Hz
4 12 VDC
For voltages other than the above, write in the voltage directly.
Note on model no. selection Select from the combination of marks in the above table.
*1: Only bore sizes Rc1/4 (item (C) 8) and Rc3/8 (item (C) 10) are available for
the FWB41 and FWB51 orifice 4mm (item (D) 5), 5mm (item (D) 6), and
7mm (item (D) 7).
*2: The bore size Rc3/8 (item (C) 10) and Rc1/2 (item (C) 15) are available for
orifice 10mm (item (D) 8).
*3: The body is cast bronze for the orifice 10mm (item (D) 8) item (E) 0 (brass).
*4: For item (F) 2CS, the surge suppressor is built into the body, and for 2HS
and 3RS, built into the terminal box.
*5: Consult with CKD for other voltages that cannot be manufactured.
79
FWB Series
FWB*1 Series: NC (normally closed) type
Internal structure and parts list
FWB*1 series
1
IN OUT
(Page 116)
Dimensions
Grommet lead wire type
FWB*1-*-*-*2C
F G H
K
L
E
D
IN OUT
C
J
View A
A B
View A
Model no. A B C D E F G H J K L
FWB21 32 14 8 45.5 56 15.5 19.5 22 Rc1/8 15 M4 depth 6
FWB31 36 18 11 57.5 68.5 18.5 22.5 28 Rc1/8, Rc1/4 18 M5 depth 6
FWB41 40 21 12 67 81 Rc1/4, Rc3/8
22.5 26 34 18 M5 depth 8
FWB41-10, 15-8 50 29 15 76 90 Rc3/8, Rc1/2
FWB51 40 21 12 73.5 89 Rc1/4, Rc3/8
26 29.5 40 18 M5 depth 8
FWB51-10, 15-8 50 29 15 82.5 98 Rc3/8, Rc1/2
80
FWB Series
FWB*1 Series: NC (normally closed) type
Optional dimensions (Page 116)
(For common dimensions, refer to the grommet lead wire dimensions on the left page.)
Grommet lead wire with surge suppressor DIN terminal box (with light and surge suppressor) HNB/G
FWB*1-*-*-* 2CS FWB*1-*-*-* 2G
A B
2HS USB/G
A
E (coil width)
B
FAB/G
FGB/G
FVB
C
D
FWB/G
IN OUT F
IN OUT
FHB
Model no. A B C D E F
FWB21 53 44 38 39 22 Pg9 FLB
Model no. A B FWB31 58.5 47 39 51 28 Pg11
FWB21 26.5 22 FWB41 61 AB
62 50.5 39 34 Pg11
FWB31 29.5 28 FWB41-10, 15-8 70
AG
FWB41 34 34 FWB51 69.5
65.5 54 39 40 Pg11
FWB51 37.5 40 FWB51-10, 15-8 78.5 AP/AD
APK/
ADK
T type terminal box (with light and surge suppressor) (G1/2) Conduit (CTC19, G1/2)
FWB*1-*-*-* 3T FWB*1-*-*-* 2CS For
3RS 2CH dry air
(Coil width)
A E C (coil width) Explosion
A D proof
B 35
HVB/
HVL
CKD SAB/
SVB
B
NP/NAP/
D
36
NVP
C
IN OUT
IN OUT G1/2 CHB/G
6-H
E
J
L
K
Model no. A B C D E F G H J K L
FWB21 40 34 30 25 15 15 5 4.5 6 1.2 20
FWB31 52 42 40 30 18 18 6 5.5 7 1.6 25
FWB41/51 56 48 44 36 18 18 6 5.5 7 1.6 30
81
FWB Series
FWB*2 Series: NO (normally open) type
Internal structure and parts list
FWB*2 series
6
IN OUT
(Page 116)
Dimensions
Grommet lead wire type
FWB*2-*-*-*2C
F G
H
L
E
D
OUT
IN
C
View A
A
B J
Model no. A B C D E F G H J K L
FWB32 36 18 11 62.5 84 18.5 22.5 28 Rc1/8, Rc1/4 18 M5 depth 6
FWB42 40 21 12 71.5 96 22.5 26 34 Rc1/4, Rc3/8 18 M5 depth 8
FWB52 40 21 12 78 103.5 26 29.5 40 Rc1/4, Rc3/8 18 M5 depth 8
82
FWB Series
FWB*2 Series: NO (normally open) type
(Page 116)
Optional dimensions
(For common dimensions, refer to the grommet lead wire dimensions on the left page.)
Grommet lead wire with surge suppressor DIN terminal box (with light and surge suppressor) HNB/G
FWB*2-*-*-* 2CS FWB*2-*-*-* 2G
2HS USB/G
A B A
FGB/G
FVB
FWB/G
C
D
FHB
IN OUT
IN OUT
F FLB
AB
Model no. A B Model no. A B C D E F
FWB32 29.5 28 FWB32 58.5 47 39 56.5 28 Pg11
AG
FWB42 34 34 FWB42 62 50.5 39 65 34 Pg11
FWB52 37.5 40 FWB52 65.5 54 39 73.5 40 Pg11 AP/AD
APK/
T type terminal box (with light and surge suppressor) (G1/2) Conduit (CTC19, G1/2)
ADK
FWB*2-*-*-* 3T FWB*2-*-*-* 2CG
3RS 2CH For
dry air
A C (coil width)
A
(Coil width) Explosion
proof
B E
D HVB/
35 HVL
SAB/
SVB
NP/NAP/
NVP
36
CHB/G
C
Other G.P.
Model no. A B C D E Model no. A B C D systems
CTC19
FWB32 92 60.5 58 84 28 FWB32 39 58 28 G1/2 PD/FAD/
CTC19 PJ
FWB42 96 64.5 67 93 34 FWB42 43 67 34 G1/2
CTC19 CVE/
FWB52 99.5 68 75 101 40 FWB52 46.5 75 40 G1/2 CVSE
CPE/
Mounting plate CPD
FWB*2-*-*-** B
Medical
A analysis
C 4-G Custom
order
Special purpose valve for water
Direct acting 2 port solenoid valve
D
B
6-H
E
J
L
K
Model no. A B C D E F G H J K L
FWB32 52 42 40 30 18 18 6 5.5 7 1.6 25
FWB42/52 56 48 44 36 18 18 6 5.5 7 1.6 30
83