01 HAZ Metal Stone Fixing Systems Brochure 2
01 HAZ Metal Stone Fixing Systems Brochure 2
01 HAZ Metal Stone Fixing Systems Brochure 2
Technical Catalogue
HAZ-SF-EN/04.20
Company Catalogue
HAZ.CC.EN.10.12
Demir Bank Headquarters, Istanbul
Contents
Company Profile 1
HDM Mortar Anchor Fixing Systems
Natural Stone Fixing System Overview 3
Introduction 34
Design Principles 5
Installation Detail 35
HZ Z Anchor Fixing System
BUN & BUG Product Details 36
Introduction 9
BTN & BTG Product Details 37
Installation Detail 10
MTN & MTG Product Details 38
HZ01 Product Details 11
HN & HG Product Details 39
HZ02 Product Details 12
HSD Mortar Anchor Fixing Systems
HZ05 Product Details 13
Introduction 40
HRS1 Product Details 14
HRD01 Product Details 40
HZ07 Product Details 15
HSD Anchor Product Details 41
HZ08 Product Details 16
HMP Sub Channel Systems
HZ02-S Product Details 17
Introduction 42
Special Z Anchors 18
Installation Detail 43
AXO Body Anchor Fixing Systems
ATS Channel System Introduction 44
Introduction 19
HMP Channel Product Details 45
Installation Detail 20
HCSP Channel Restraint Product Details 46
BA Product Details 21
HCRS Channel Restraint Product Details 47
AXO1&2 Product Details 22
HMP Sub Channel Systems Examples 48
AXO3 Product Details 23
Special Sub Channel Systems 49
AXO4 Product Details 24
Aluminium Channel Systems 50
HRS3 Product Details 25
Heavy Duty Fixing Systems 52
HZTA Product Details 26
HCA Corner Anchors 54
Special Body Anchors 27
HAZ Accessories 55
HA L Anchor Fixing Systems
HB Expansion Bolts
Introduction 28
HB01, HB03 & HB05 Product Details 56
Installation Detail 29
HB06, HB07 & HB11 Product Details 57
HA01 Product Details 30
References 58
HA02&HA03 Product Details 31
HA04&HA05 Product Details 32
Special L Anchors 33
HAZ Metal
• HAZ Metal Sanayi
Sanayi ve Ticaretve
A.S.Ticaret A.S. All
All rights reserved. Aprilrights reserved.
2020.Reproduction March of2012.
and distribution Reproduction
the information and
contained in this distribution
catalogue of the
is forbidden without information
prior
R
contained
written consent. HAZ Copyright. in this catalogue is forbidden
1
Company Profile
The technical department receives the necessary technical The factory is equipped with a coil slitting machine, channel roll
information of the project in order to design the most suitable, secure, formers, press breaks, eccentric presses, automated end part
easy to use and economical fixing systems in accordance with the formers, thread rolling machines, cold forge bolt makers and
project criteria. Custom design and production is also made after various production units. There is also an in house electro
receiving detailed architectural drawings of the project. galvanizing unit where 12 micro thick zinc coating on mild steel
is made. Hot dip galvanizing with over 50 micro thick zinc
HAZ Metal provides the necessary documentation and structural coating is made by prequalified sources outside the factory.
calculation reports for submittal in order to approve the designed
fixing systems. Emphasis has also been given to automation in which faster
production and lower costs are achieved through higher
Quality Standards efficiency. HAZ Metal is able to design and build apparatus and
progressive dies in order speed up production.
HAZ Metal implements internationally recognised standards in the
design and production of fixing systems. Product design and produc- The presence of a work shop with the capability of preparing and
tion is strictly controlled within the specifications of these standards. maintaining the required moulding and tooling, provides flexible
All products are designed and produced by its personnel, applying production. The quick preparation, maintenance, alteration and
the latest production methods with modern machinery. In order to adjustment of machines and tooling are made without
guarantee outstanding quality to their clients, HAZ Metal has interrupting the production process which leads to saving time
established a testing laboratory at the factory, to inspect materials and costs. This enables fast and flexible production to supply
during each stage of production. projects of any size.
3
The following points are taken into consideration when designing • Fixing to concrete with bolts.
a fixing system for natural stone installation. • Projection sizes up to 150 mm.
• Recommended for loads up to 800 N.
• Stone type and dimensions. • Installation at horizontal or vertical joints.
• Cavity structure: projection size and insulation. • Three dimensional adjustability.
• Application type: horizontal or vertical joint installation.
• Joint size.
• Structural wall backing.
• Height of facade.
• Relevant dynamic loads such as wind and seismic loads.
AXO Body Anchor Fixing
• Design criteria of the project.
HAZ Metal is known as a high quality and reliable service provider for the design and supply of fixing systems in the construction industry.
Major projects have been successfully supplied with HAZ Metal fixing systems. The main advantage of HAZ Metal is the ability to custom
design fixing systems and provide fast production to meet the time restraint requirements of projects. The design and supply is done in
accordance with international standards and more importantly with our customers’ expectations.
Design Principles
HAZ Metal can offer the design and engineering services by referring to any
internationally renown standards. The engineering department will relate to the
specifications of the project and conduct its design and dimensioning
according to the requested criteria.
British Standards
German Standards
American Standards
Euro codes
Design Principles
Design Factors
The following design factors are considered
h • Marble
&Limestone: (27000 N/m3)
St C I
• Granite: (28000 N/m3)
K
St w
W • Minimum 2 mm space
should be left between the
h/1
slab below and the bottom
edge of the adjustable arm.
h/2
• A plastic tube is inserted
on the slabs below to
h/3
absorb wind loads.
≥2,5 x St St ≥30 w/2 w/3 w/4
Dead loads:
Weight of natural stone slabs is determined
Fdw= h (m) x w (m) x st(m) ds (KN/m3)
Fdw is multiplied with 1.35 safety factor.
Wind loads:
The max. speed is; vs.
The value of the dynamic pressure of the wind
is q=k Vs2
The max. design pressure is; wp=cp.Q
The max. design suction is; ws=cs.Q
ws=0.7.Q (normal)
ws=2.0.Q (edge)
wp & ws are multiplied with 1.50 safety factor
Thermal loading:
The following temperature is considered.
Design Principles
Application Type
Horizontal Joints
The anchors carry half the weight of the natural stone slabs in horizontal installation. Anchors bear half the weight of the slab above and also
act as restraint, holding the slabs below and restraining them against wind pressure and suction.
Load Bearing
Indirect fixing to channels
Min. Projection size 90 mm.
Vertical Joints
The load bearing anchors carry the full weight of the natural stone slab in vertical installation. Each anchor bears half the weight of the slab on
the right and half the weight of the slab on the left. Restraint anchors hold the slabs below and restrain them against wind pressure and
suction.
Design Principles
Load Principles
Vertical (Dead Load) and Horizontal (Wind Load) loads are determined according to the following diagram. The following principle is applied
before designing a fixing system.
Vertical load from dead load FWP = (w x h x qp) / 2 ( for each anchor)
FDW = (st x w x h x ds) / 2 (for each anchor) FWS = (w x h x qs) / 2 ( for each anchor)
FDW
FWS / FWP
Vertical load from dead load FWP = (w x h x qp) / 2 ( for each anchor)
FDW = (st x w x h x ds) / 1 (for each anchor) FWS = (w x h x qs) / 2 ( for each anchor)
FWS / FWP
FDW
Material Grade
Product Type Stainless Steel Steel
Anchors, adjustable arms and pins must AISI = W.-Nr. DIN = W. -Nr.
be stainless steel grade AISI 304 - 1.4301 304 = 1.4301
(A2) & AISI 316-1.4401 (A4). Anchors 316 = 1.4401 Not Advisable
316Ti = 1.4571
Recommended material specifications for
304 = 1.4301 Hot dip galv. St 37-2 = 1.0037
fixing systems are shown in the following Channels Hot dip galv. St 44-2 = 1.0044
316 = 1.4401
table.
DIN 933
Bolts Electro galv. St 37
(A2/50-A2/70)
Strength class 4.6/8.8
A4/50-A4/70)
DIN 934 & DIN 439
Hexagon Nuts Electro galv. St 37
(A2/50-A2/70)
Strength class 8
A4/50-A4/70)
Washers DIN 125 ST DIN 125
9
• Direct fixing into concrete walls with expansion bolts. Indirect fixing into sub channel system with hex bolts.
• Three dimensional adjustability - Quick and easy fixing.
• Installation at horizontal and vertical joints.
• Recommended projection sizes up to 150 mm & loads up to 800 N.
• Suitable for concrete walls. Anchors are fixed directly on to concrete walls with expansion bolts.
• In horizontal joint installation, slabs are pinned on the bottom and upper sides. Anchors act as load bearing carrying half the weight of
the slabs above. Anchors also act as restraints, holding the slabs below and restraining against wind suction and pressure.
• In vertical joint installation slabs are pinned on the left and right sides. Anchors on the bottom are load-bearing anchors carrying the
whole weight of the slab. Half the weight of the slab on the left and half the weight of the slab on the right. Anchors on the top are
restraint anchors holding the slabs and restraining against wind suction and pressure.
• The design and structural calculations of these anchors are made in our technical department. Special design and manufacturing can
be made for the requirements of each project.
Your Fixing Systems Specialist | 10
Shape C Shape D
Shape E Shape F
Shape G Shape H
1- Through bolt
A 2- Anchor body
3- Serrated washer
4- Round washer
5- Hex nut for through bolt Shape J Shape K
6- Hex nut for adjustable arm
7- Adjustable arm
8- Plastic tube
9- Flanged pin
Restraint
Load Bearing
Restraint
HZ02 Z Anchor
Load Bearing
Fdw
For anchoring into
concrete ≥ C20/25
Cement
grout K
E.b.
Load
Bearing
Ø
Restraint EAL
Plastic
tube
F
St=20-50 mm
St
Technical details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HZ01-452 45 40 55 10 60
HZ01-552 55 45 70 20 60
200 312 219 M8X80 5 M10 3.5
HZ01-752 75 60 90 40 60
HZ01-952 95 80 110 60 60
HZ01-553 55 50 70 20 60
HZ01-753 75 60 90 40 60
300 468 328 M8X80 5 M10 3.5
HZ01-953 95 80 110 60 60
HZ01-1153 115 100 130 80 60
HZ01-554 55 50 65 10 70
HZ01-754 75 60 90 20 90
400 624 437 M10X90 5 M12 4.5
HZ01-954 95 80 110 40 90
HZ01-1154 115 100 130 60 90
HZ01-755 75 60 90 20 90
HZ01-955 95 80 110 40 90
500 780 546 M10X90 5 M12 4.5
HZ01-1155 115 100 130 60 90
HZ01-1355 135 120 150 80 90
HZ01 Z Anchor
• Load bearing & restraint • Projection sizes between 45 and 150 mm • Loads up to 500 N
• Three dimensional adjustability • Suitable for horizontal & vertical joints • Stone thicknesses 20-50 mm
• Fastened on to load bearing walls with expansion bolts and on to channels with set screws
Product Code Description Shape A Shape B Shape C Shape D
HZ01 - 45 2 A
Shape
Dead Load (x10 Kg)
Projection (mm)
Type
Your Fixing Systems Specialist | 12
Fdw
For anchoring into
concrete ≥ C20/25
Cement
grout K
E.b.
Load
Bearing
Restraint EAL
Plastic
tube
F
St St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HZ02-452 45 40 55 10 60
HZ02-552 55 45 70 20 60
200 312 219 M8X80 5 M10 3.5
HZ02-752 75 60 90 40 60
HZ02-952 95 80 110 60 60
HZ02-553 55 45 70 20 60
HZ02-753 75 60 90 40 60
300 468 328 M8X80 5 M10 3.5
HZ02-953 95 80 110 60 60
HZ02-1153 115 100 130 80 60
HZ02-554 55 45 65 10 70
HZ02-754 75 60 90 20 90
400 624 437 M8X80 5 M12 4.5
HZ02-954 95 80 110 40 90
HZ02-1154 115 100 130 60 90
HZ02-755 75 60 90 20 90
HZ02-955 95 80 110 40 90
500 780 546 M8X80 5 M12 4.5
HZ02-1155 115 100 130 60 90
HZ02-1355 135 120 150 80 90
HZ02-756 75 60 90 20 90
HZ02-956 95 80 110 40 90
600 936 655 M10X90 6 M14 5.5
HZ02-1156 115 100 130 60 90
HZ02-1356 135 120 150 80 90
HZ02-758 75 60 90 20 90
HZ02-958 95 80 110 40 90
800 1235 865 M10X90 6 M14 5.5
HZ02-1158 115 100 130 60 90
HZ02-1358 135 120 150 80 90
• Material : Stainless Steel 1.4301 (A2) & 1.4401 (A4).• Table above is prepared according to Eurocode standard.• Loads
stated are working resistance loads. • Other sizes are available for production upon request. • Bolts are provided
separately. • Structural calculation reports are available upon order.
HZ02 Z Anchor
• Load bearing & restraint • Projection sizes between 45 and 150 mm • Loads up to 800 N
• Three dimensional adjustability • Suitable for horizontal & vertical joints • Stone thicknesses 20-50 mm
• Fastened on to load bearing walls with expansion bolts and on to channels with set screws
Product Code Description Shape A Shape B Shape C Shape D
HZ02 - 45 2 A
Shape
Dead Load (x10 Kg)
Projection (mm)
Type
13
Fdw
For anchoring into
concrete ≥ C20/25
Cement
grout K
E.b.
Load
Bearing
Restraint EAL
Plastic
tube
F
St St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HZ05-452 45 40 55 10 60
HZ05-552 55 45 70 20 60
200 312 219 M8X80 5 M10 3.5
HZ05-752 75 60 90 40 60
HZ05-952 95 80 110 60 60
HZ05-553 55 50 70 20 70
HZ05-753 75 60 90 40 70
300 468 328 M8X80 5 M10 3.5
HZ05-953 95 80 110 60 70
HZ05-1153 115 100 130 80 70
HZ05-554 55 50 65 10 70
HZ05-754 75 60 90 20 90
400 624 437 M8X80 5 M12 4.5
HZ05-954 95 80 110 40 90
HZ05-1154 115 100 130 60 90
HZ05-755 75 60 90 20 90
HZ05-955 95 80 110 40 90
500 780 546 M8X80 5 M12 4.5
HZ05-1155 115 100 130 60 90
HZ05-1355 135 120 150 80 90
adjustability
HZ05 Z Anchor
• Load bearing & restraint • Projection sizes between 45 and 150 mm • Loads up to 500 N
• Three dimensional adjustability • Suitable for horizontal & vertical joints • Stone thicknesses 20-50 mm
• Fastened on to load bearing walls with expansion bolts and on to channels with set screws
Product Code Description Shape A Shape B Shape C Shape D
HZ05 - 45 2 A
Shape
Dead Load (x10 Kg)
Projection (mm)
Type
Your Fixing Systems Specialist | 14
Cement
Grout
Restraint E.b.
Fws/Fwp
T M
Plastic Ø EAL
Tube
St St=20-50 mm
Technical Details
Projec- Min. Max. Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Size Pressure Suction Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HRS1-55 * 55 45 60 20 60
HRS1-75 75 60 90 40 60
HRS1-95 95 80 110 60 312 219 M8X80 5 M8 3 60
HRS1-115 115 100 130 60 80
HRS1-135 135 115 150 60 100
Shape
Projection (K mm)
Type
15
E.b. E.b.
M
F
K
EAL
St
Ø
T
Fdw
Cement Grout Plastic Tube
Technical Details
Projec- Min. Max. Dead Forming Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Size Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HZ07-452 45 40 55 10 60
HZ07-552 55 45 70 20 60
200 M8X80 5 M10 3.5
HZ07-752 75 60 90 40 60
HZ07-952 95 80 110 60 60
HZ07-553 55 50 70 20 60
HZ07-753 75 60 90 40 60
300 M8X80 5 M10 3.5
HZ07-953 95 80 110 60 60
HZ07-1153 115 100 130 80 60
HZ07-554 55 50 65 10 70
HZ07-754 75 60 90 20 80
400 M8X80 5 M12 4.5
HZ07-954 95 80 110 40 80
HZ07-1154 115 100 130 60 80
Fdw
For anchoring into
concrete ≥ C20/25
Cement K
grout
E.b.
Load
Bearing
Fws/Fwp
T M M
Restraint EAL
Plastic
tube
F
St St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HZ08-1152 115 85 130 80 60
HZ08-1352 135 105 150 200 100 312 219 M8x80 5 M10 3.5 60
HZ08-1552 155 135 170 120 60
HZ08-1153 115 100 130 80 60
HZ08-1353 135 120 150 300 100 468 328 M8x80 5 M10 3.5 60
HZ08-1553 155 140 170 120 60
HZ08-1154 115 100 130 80 80
HZ08-1354 135 120 150 400 100 624 437 M8x80 5 M12 4.5 80
HZ08-1554 155 140 170 120 80
HZ08 Z Anchor
• Load bearing & restraint • Projection sizes between 115 and 170 mm • Loads up to 400 N
• Three dimensional adjustability • Suitable for horizontal & vertical joints • Stone thicknesses 20-50 mm
• Fastened on to load bearing walls with expansion bolts and on to channels with set screws
Product Code Description Shape A Shape B Shape C Shape D
HZ08 - 115 2 A
Shape
Dead Load (x10 Kg)
Projection (mm)
Type
17
2 5 mm
9 mm Cement
Grout K
LGA TEST REPORT Load E.b.
No : BBW 121 51 21 Bearing
Date : 15.10.2006
M
Ø
M T
Restraint EAL
Plastic
Ø Tube &
EA L
70
Cement Grout F
St St=20-50 mm
Technical Details
Projec- Min. Max. Dead Offset Wind- Wind- Bolt Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Pressure Suction Size Diameter Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
HZ02-S-33010/10 40 40 50 500 10 50
HZ02-S-33015/10 45 45 55 500 15 50
HZ02-S-33020/10 50 50 60 500 20 50
HZ02-S-33030/10 65 50 80 400 30 60
HZ02-S-33040/10 75 60 90 400 40 M10 3.5 60
HZ02-S-33050/10 85 70 100 400 50 60
HZ02-S-33060/10 95 80 110 300 60 60
HZ02-S-33080/10 125 110 140 300 80 312 219 M8x80 ø 5x70 70
HZ02-S-330100/10 145 130 160 250 100 70
HZ02-S-330120/10 165 150 180 250 120 70
HZ02-S-43020/12 60 55 70 500 20 70
HZ02-S-43040/12 90 75 105 500 40 80
HZ02-S-43060/12 110 95 125 400 60 M12 4.5 80
HZ02-S-43080/12 130 115 145 400 80 80
HZ02-S-430100/12 150 135 165 300 100 80
HZ02-S-430120/12 170 155 185 300 120 80
HZ02-S type Z anchors with HZ02-2S Type without HZ05-S Type with HZ05-2S Type with Shape A Shape B
standard sizes. Different serration and with riveted nut. Serrated riveted nut. Without
types available according to plain washer. with serrated serration and with
desired method of fixation. washer. plain washer.
Product Code Description Shape C Shape D
HZ02-S - 330 / 10 A
Shape
Adj. arm M size (mm)
Anchor body size (mm)
Anchor type
Your Fixing Systems Specialist | 18
Can be used for loads that are over 800 N when stronger
vertical stabilization is required
Special Designs
Z Anchors are fixed on sub frame to Z Anchors are fixed on to special steel Z Anchors are fixed on to special steel
install cornice lining. structure for cornice parapet installation. structure for special area installation.
19
• Direct fixing in to concrete walls with expansion bolts. Indirect fixing on to sub channel systems with hex bolts.
• Three dimensional adjustability - Quick and easy fixing.
• Installation at horizontal and vertical joints.
• Optimum static performance and low engineering for higher loads and larger projection sizes.
• Recommended projection sizes up to 260 mm and loads up to 1300 N.
1) Vertical adjustment is provided 2) Adjusting the projection size by simply 3) Adjusting the anchor left and right is
through the body space. The anchor is moving the adjustable arm without provided by sliding the body up to 15
fixed onto the bolt through the wedge rotating. The adjustable arm is safely degrees left or right.
washer and the lock washer at the fixed to the anchor body with the lock
desired level. nut and hex bolt.
• Suitable for concrete walls. Anchors are fixed on to concrete walls with expansion bolts.
• In horizontal installation, slabs are pinned on the bottom and upper sides. The anchors act as load bearing, carrying half the weight of
the slabs above. Anchors also act as restraint holding the slabs below and restraining against wind suction and pressure.
• In vertical installation, slabs are pinned at the left and right sides. The anchors on the bottom are load-bearing anchors carrying the
whole weight of the slab. Half the weight of the slab on the left and half the weight of the slab on the right. The anchors on the top are
restraint anchors holding the slabs and restraining against wind suction and pressure.
• The design and structural calculations of these anchors are made in our technical department. Special design and manufacturing can
be made for the requirements of the project.
Your Fixing Systems Specialist | 20
Shape C Shape D
Shape E Shape F
Restraint
AXO4
Body Anchor
Load Bearing
& Restraint
Load Bearing
Restraint
Load Bearing
Fws/Fwp
T M
Body 1607
Restraint Ø
Body 1207
Body 858 EAL
Body 609 Plastic
tube
St F St=20-50 mm
Fdw
For anchoring into
concrete ≥ C20/25
K
Cement
grout
E.b.
Load
bearing
x
Fws/Fwp
T M
Ø
Ø
Restraint
EAL
Plastic
tube
St F St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length Size
Code tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
BA-609 BODY 1 60 50 75 900 28 1100 770 70
BA-858 BODY 2 85 70 100 800 46 700 700 70
M8X80 5 M12 4.5 50
BA-1207 BODY 3 120 95 135 700 75 650 650 80
BA-1607 BODY 4 160 145 175 700 115 600 600 80
BA Body Anchor
• Load bearing & restraint • Projection sizes between 60 and 160 mm • Loads up to 900 N
• Three dimensional adjustability • Suitable for horizontal & vertical joints • Stone thicknesses 20-50 mm
• Fastened on to load bearing walls with expansion bolts and on to channels with set screws
Product Code Description Shape A Shape B Shape C Shape D
BA - 60 9 A
Shape
Dead Load (x10 Kg)
Projection (K mm)
Type
Your Fixing Systems Specialist | 22
Fws/Fwp
T M
Restraint Ø
EAL
Plastic
tube
St St=20-50 mm
F
Fdw
For anchoring into
concrete ≥ C20/25
K
Cement
grout
E.b.
Load
bearing
x
Fws/Fwp
T M
Ø
Ø
Restraint
EAL
Plastic
tube
St F St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length Size
Code tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
AXO1-705 70 55 85 20
500 780 546 M8X80 5 M12 4.5 80 50
AXO1-1105 110 95 125 60
AXO1-7013 70 55 85 20 80 50
1300 2028 1419 M10X90 6 M16 6
AXO1-11013 110 95 125 60
AXO2-1505 150 135 165 500 100 780 546 M8X80 5 M12 4.5 80 50
AXO2-15013 150 135 165 1300 100 2028 1419 M10X90 6 M16 6
Fdw
For anchoring into
concrete ≥ C20/25
K
Cement
Grout
E.b.
Load
Bearing
x
Fws/Fwp
T M
Ø
Restraint EAL
Plastic
Tube &
F
St St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length Size
Code tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
AXO3-2005 200 180 220 155
AXO3-2205 220 200 240 175
500 780 546 M8X120 5 M12 4.5 80 75
AXO3-2405 240 220 260 195
AXO3-2605 260 240 280 215
AXO3-2009 200 180 220 155
AXO3-2209 220 200 240 175
AXO3-2409 240 220 260 900 195 1430 1000 M10X130 6 M14 5.5 80 75
Fws/Fwp
T M
Ø
Restraint EAL
Plastic
Tube &
F
St St=20-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length Size
Code tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
AXO4-1605 160 140 180 115
AXO4-1805 180 160 200 135
AXO4-2005 200 180 220 155
500 780 546 M8X120 5 M12 4.5 100 75
AXO4-2205 220 200 240 175
AXO4-2405 240 220 260 195
AXO4-2605 260 240 280 215
AXO4-1609 160 140 180 115
AXO4-1809 180 160 200 135
AXO4-2009 200 180 220 155
900 1430 1000 M10X130 6 M14 5.5 100 75
AXO4-2209 220 200 240 175
AXO4-2409 240 220 260 195
AXO4-2609 260 240 280 215
AXO4-16013 160 140 180 115
AXO4-18013 180 160 200 135
AXO4-20013 200 180 220 155
2028 1419 M12X145 6 M16 6 100 80
AXO4-22013 220 200 240 1300 175
AXO4-24013 240 220 260 195
AXO4-26013 260 240 280 215
T Fws/Fwp M
Plastic Ø
Tube &
EAL
St F
St=20-50 mm
Technical Details
Projec- Min. Max. Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product
tion Projec- Projec- Size Pressure Suction Bolt Size Size Metric Flat Length Size
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
HRS03-60 60 40 80 70
25
HRS03-80 80 60 100 90
HRS03-100 100 80 120 100
HRS03-120 120 100 140 120
HRS03-140 140 120 160 32 140
HRS03-160 160 140 180 2028 1419 M8X80 5 M8 3 160 30
HRS03-180 180 160 200 170
HRS03-200 200 180 220 40 190
HRS03-220 220 200 240 210
HRS03-240 240 220 260 220
HRS03-260 260 240 280 50 240
Shape
Projection (K mm)
Type
Your Fixing Systems Specialist | 26
Load
Bearing
x
Fws/Fwp
T M
Ø
Restraint EAL
Plastic
Tube &
F
St
St=30-50 mm
Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Dia. Flat Length Size
Code tion tion Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
HZTA-15011 150 135 165 90
HZTA-18011 180 165 195 120
HZTA-21011 210 195 225 150
1100 1300 1300 M10 6 Ø21,3 4 132 75
HZTA-24011 240 225 255 180
HZTA-27011 270 255 285 210
HZTA-30011 300 285 315 240
Dead Load
Projection (K mm)
Type
27
Special Designs
Body anchors are used for stone Body anchors are used to form an oval Body anchors used for installation of
installation around columns. column in natural stone. parapet area.
t:
5m
m
t:
5m
m
Your Fixing Systems Specialist | 28
• Direct fixing into concrete walls with expansion bolts. Indirect fixing onto sub channel system with hex bolts.
• Economical & easy fixing.
• Installation at horizontal joints.
• Adjustability provided through adjustable plates and slot pin holes.
HA01 L Anchor HA02 L Anchor HA03 L Anchor HA04 L Anchor HA05 L Anchor With Adj. Plate
Double Pin With Kerf With Adjustable Plate & Welded Tie
Adjustability
Fdw/2 Fdw/2
• Suitable for concrete walls. • Suitable for concrete walls. • Suitable for concrete walls.
Recommended projection sizes up to Recommended projection sizes up to Recommended projection sizes up to
55 mm. 55 mm. 180 mm.
• Slabs are pinned at the bottom and • Slabs have slits and the kerf parts of • Slabs are pinned from the bottom and
upper sides. the anchors are inserted in to the slit upper sides.
• Adjustability for projection size can be edges of the slabs. • Adjustability of the projection size is
done by inserting shims between the • Adjustability for projection size can be enabled with the adjustable plate, which
anchor and the wall. done by inserting shims between the is fixed to the body with hex bolts.
• Anchors act as load bearing and anchor and the wall. • Anchors act as load bearing and
restraint, carrying the slabs above and • Anchors act as load bearing and restraint, carrying the slabs above and
restraining the slabs below. restraint, carrying the slabs above and restraining the slabs below.
restraining the slabs below.
29
Anchor
Variations
1- Through bolt
2- Anchor body
3- Serrated washer
4- Round washer for through bolt
5- Hex nut for through bolt
6- Plastic tube
7- Flanged pin
HA01
L Anchor
HA04
L Anchor
Your Fixing Systems Specialist | 30
Fdw
For anchoring into
concrete ≥ C20/25
K
Cement grout
Fws/Fwp
T
Restraining
Plastic tube St L
St=20-50 mm
Technical Details
Product Projection Dead Wind Wind Bolt Size Pin Anchor Anchor
Code Load Pressure Suction Diameter Length Thickness
K (mm) Fdw (N) Fwp (N) Fws (N) E.b. (mm) ø (mm) L (mm) T (mm)
HA01-301 30 36
HA01-351 35 41 2
HA01-401 40 46
100 156 110 M8X80 4
HA01-451 45 51
HA01-501 50 56 2.5
HA01-551 55 61
HA01-302 30 38
HA01-352 35 43 3
HA01-402 40 200 312 219 M8X80 4 48
HA01-452 45 53
HA01-502 50 58
4
HA01-552 55 63
HA01-303 30 38
3
HA01-353 35 43
HA01-403 40 328 5 48
300 468 M8X80
HA01-453 45 53
4
HA01-503 50 58
HA01-553 55 63
HA01-304 30 38 3
HA01-354 35 43
HA01-404 40 48
437 5
HA01-454 45 400 624 M8X80 53 4
HA01-504 50 58
HA01-554 55 63
• Material: Stainless Steel 1.4301 (A2) & 1.4401 (A4). • Other sizes are available for production upon request.
• Table above is prepared according to Eurocode standard. • Bolts are provided separately.
• Loads stated are working resistance loads. • Structural calculation reports are available upon order.
HA01 L Anchor
• Load bearing & restraint • Projection sizes between 30 and 35 mm • Loads up to 400 N
• Limited adjustability • Suitable for horizontal • Stone thicknesses above 20 mm
• Fastened on to load bearing walls with expansion bolts and on to channels with set screws
Product Code Description Shape A Shape B Shape C
HA01 - 30 1 A
Shape
Dead Load (x10 Kg)
Projection (K mm)
Type
31
Technical Details
Product Projection Dead Load Wind Wind Bolt Size Pin Anchor Anchor
Code Pressure Suction Diameter Length Thickness
Shape B
K (mm) Fdw (N) Fwp (N) Fws (N) E.b. (mm) ø (mm) L (mm) T (mm)
HA02-302 30 38
HA02-352 35 43
HA02-402 40 48
200 312 219 M8X80 4 3
Shape C HA02-452 45 53
HA02-502 50 58
HA02-552 55 63
HA02-304 30 38
HA02 - 30 2 A
HA02-354 35 43
Shape
HA02-404 40 48
Dead Load (x10 Kg)
HA02-454 45 400 624 437 M8X80 6 53 4
Projection (K mm)
Type HA02-504 50 58
HA02-554 55 63
20mm.
Fws/Fwp
• Fastened on walls with
expansion bolts. Kr
Technical Details
Product Projection Dead Load Wind Wind Bolt Size Pin Anchor Anchor
Code Pressure Suction Diameter Length Thickness
Shape B
K (mm) Fdw (N) Fwp (N) Fws (N) E.b. (mm) ø (mm) L (mm) T (mm)
HA03-302 30 32
HA03-352 35 37
3
HA03-402 40 42
Shape C 200 312 219 M8X80 12
HA03-452 45 47
HA03-502 50 52
4
HA03-552 55 57
HA03-304 30 32 3
HA03 - 30 2 A
HA03-354 35 37
Shape
HA03-404 40 42
Dead Load (x10 Kg)
HA03-454 45 400 624 437 M8X80 15 47 4
Projection (K mm)
Type HA03-504 50 52
HA03-554 55 57
Your Fixing Systems Specialist | 32
Technical Details
Shape B Product Projec- Min. Max. Dead Wind Wind Bolt Pin Anchor Adj. Adj.
tion Projec- Projec- Load Pressure Suction Size Diameter Length Plate Plate
Code tion tion Length Thickness
K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) E.b. (mm) ø (mm) L (mm) Lp (mm) T (mm)
20mm. Fws/Fwp
T
• Fastened on walls with
expansion bolts. Ø
• Adjustability of the projection
Restraining Lp
size is provided with the
adjustable plate. L
Plastic Tube
St St=20-50 mm
Shape A
Technical Details
Shape B Projec- Min. Max. Dead Wind Wind Bolt Pin Anchor Adj. Adj.
Product
tion Projec- Projec- Load Pressure Suction Size Diameter Length Plate Plate
Code tion tion Length Thickness
K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) E.b. (mm) ø (mm) L (mm) Lp (mm) T (mm)
Special Designs
L anchors are used to install thick L anchors are used to support large semi L anchors used for stone installation
stone slabs around corners. circular stones to forming a massive around column with variations in
column block. stone and projection.
Your Fixing Systems Specialist | 34
Restraint Anchors
• Direct fixing to concrete and masonry walls with mortar
• Economical & easy fixing HN HG
• Installation at vertical and horizontal joints
• Special design for installing heavy loads at large projection sizes
Installation at horizontal joints with BUG anchors Installation at vertical joints with BTN & HG anchors
Fdw/1 Fdw/1
Fdw/2 Fdw/2
Restraint
Load Bearing
Load Bearing &
Restraint
• Holes 6mm larger than the anchor width are drilled in the
walls.
• The holes are filled with mortar and anchors are set into mortar
Fdw/1 Fdw/1 bed.
Restraint • In vertical joint installation, slabs are pinned at the left and
right sides. Anchors on the bottom are load bearing anchors
Load Bearing
carrying the whole weight of the slab.
Half the weight of the slab on the left and half the weight of the
slab on the right. Anchors on the top are restraint anchors
holding the slabs and restraining against wind suction and
pressure.
35
Anchor
Variations
Shape A
Shape B
1- Anchor Body
2- Flanged pin
3- Plastic
Restraint
BUG
Mortar Anchor Load Bearing
Load Bearing
Restraint
HG
Restraint Anchor
Load Bearing
BUN
Mortar Anchor
Load Bearing & Restraint
Your Fixing Systems Specialist | 36
Technical Details
Projec- Min. Max. Dead Wind Wind Z Embedded Pin Bore Anchor
Product
tion Projec- Projec- Load Pressure Suction Size Length Diameter Diameter Thickness
Code tion tion
K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) Z (mm) L1 (mm) ø (mm) Bø (mm) T (mm)
Shape B
BUN-622 220 210 230 600 393 786 22 80 5 34 3
BUN-624 240 230 250 38
BUN-816 160 150 170
BUN-818 180 170 190 32
BUN-820 200 190 210 800 524 1048 22 80 5 4
BUN-822 220 210 230
36
BUN-824 240 230 250
BUN-1016 160 150 170
BUN-1018 180 170 190 32
BUN-1020 200 190 210 1000 655 1310 22 80 6 4
BUN - 6 22 A BUN-1022 220 210 230
Shape BUN-1024 240 230 250
Projection (x10mm)
BUN-1216 160 150 170
BUN-1218 180 170 190
Dead Load (x10 Kg) 36
BUN-1220 200 190 210 1200 818 1636 22 80 6 4
Type BUN-1222 220 210 230
BUN-1224 240 230 250 38
Shape A
K St=20-50 mm
St
Shape A
Technical Details
Projec- Min. Max. Dead Wind Wind Embedded Pin Bore Anchor
Product
tion Projec- Projec- Load Pressure Suction Length Diameter Diameter Thickness
Code tion tion
Shape B K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) L1 (mm) ø (mm) Bø (mm) T (mm)
BTN - 4 16 A
Shape
Projection (x10mm)
Dead Load (x10 Kg)
Type
Shape A K
St=20-50 mm
St
Technical Details
Shape B
Projec- Min. Max. Dead Wind Wind Z Embedded Pin Bore Anchor
Product
tion Projec- Projec- Load Pressure Suction Size Length Diameter Diameter Thickness
Code tion tion
K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) Z (mm) L1 (mm) ø (mm) Bø (mm) T (mm)
Plastic
Ø Tube
(Top View)
Shape A St
Technical Details
Projec- Min. Max. Dead Wind Wind Embedded Pin Bore Anchor
Product
tion Projec- Projec- Load Pressure Suction Length Diameter Diameter Thickness
Code tion tion
Shape B K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) L1 (mm) ø (mm) Bø (mm) T (mm)
MTN-4 8 80 70 90 30 5
MTN-414 140 130 140 400 295 589 90 5 34 5
MTN-418 180 170 180 36 6
MTN-6 6 60 50 70 6
34
MTN-612 120 110 130 600 442 884 90 5 6
MTN-620 200 190 210 38 6
MTN-10 8 80 70 80 38 6
MTN-1024 140 130 140 100 737 1473 90 5 40 6
MTN-1018 180 170 190 42 6
• Material: Stainless Steel 1.4301 (A2) & 1.4401 (A4).
MTN - 4 8 A
• Table below is prepared according to Eurocode standard.
Shape • Loads stated are working resistance loads.
Projection (x10mm) • Other sizes are available for production upon request.
Dead Load (x10 Kg) • Structural calculations are available upon order.
Type
Plastic Tube
Shape A
St
Technical Details
Shape B Product Projec- Min. Max. Dead Wind Wind Z Embedded Pin Bore Anchor
tion Projec- Projec- Load Pressure Suction Size Length Diameter Diameter Thickness
Code tion tion
K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) Z (mm) L1 (mm) ø (mm) Bø (mm) T (mm)
HN Mortar Anchor&Restraint L1
20-50 mm.
• Fastened into concrete
≥C20/25 Masonry M12/II Mortaring into
walls with mortar. concrete ≥ C20/25
K
and Masonry M12/II
Shape A St
Technical Details
Product Projec- Min. Max. Wind Wind Embedded Pin Bore Anchor
tion Projec- Projec- Pressure Suction Length Diameter Diameter Thickness
Code
tion tion
Shape B K (mm) K - (mm) K + (mm) Fwp (N) Fws (N) L1 (mm) ø (mm) Bø (mm) T (mm)
HN - 10 16 A
Shape
Projection (x10mm)
Dead Load (x10 Kg)
Type
HG Mortar Anchor
• Restraint only. St L1
• Projection sizes between 100 Fdw
Technical Details
Shape B Product Projec- Min. Max. Wind Wind Embedded Pin Bore Anchor
tion Projec- Projec- Pressure Suction Length Diameter Diameter Thickness
Code
tion tion
K (mm) K - (mm) K + (mm) Fwp (N) Fws (N) L1 (mm) ø (mm) Bø (mm) T (mm)
HSD01 Mortar Anchor HSD02 Mortar Anchor HSD03 Mortar Anchor HSD04 Mortar Anchor HRD01
W. Plate Twisted Head W. Plate & Twisted Mortar Anchor
Technical Details
Shape B Product Projec- Min. Max. Dead Wind Wind Anchor Dowel Pin Bore Flat
tion Projec- Projec- Load Pressure Suction Length Embedded Diameter Diameter Thickness
Code tion tion Length
K (mm) K - (mm) K + (mm) Fdw (N) Fwp (N) Fws (N) L (mm) L1 (mm) ø (mm) Bø (mm) T (mm)
HSD01-352 35 20 50 135 21
HSD01-452 45 30 60 145
HSD01-552 55 40 70 200 312 219 155 90 4 2.5
HSD01-652 65 50 80 165 24
HSD01-752 75 60 90 175
HSD01-354 35 20 50 135 26
HSD01-454 45 30 60 145
HSD01-554 55 40 70 400 624 437 155 90 5 28 2.5
HSD01-654 65 50 80 165 30
HSD01-754 75 60 90 175 32
HSD01-356 35 20 50 135
HSD01-456 45 30 60 145 26
HSD01-556 55 40 70 600 936 655 155 90 6 28 4
HSD01-656 65 50 80 165 30
HSD01-756 75 60 90 175 32
HSD02-352 35 20 50 135 24
HSD02-452 45 30 60 145
HSD02-552 55 40 70 200 312 219 155 90 4 2.5
HSD02-652 65 50 80 165 28
HSD02-752 75 60 90 175
HSD02-354 35 20 50 135 30
HSD02-454 45 30 60 145
HSD02-554 55 40 70 400 624 437 155 90 5 32 2.5
HSD02-654 65 50 80 165 34
HSD02-754 75 60 90 175 36
HSD02-356 35 20 50 135
HSD02-456 45 30 60 145 30
HSD02-556 55 40 70 600 936 655 155 90 6 32 4
HSD02-656 65 50 80 165 34
HSD02-756 75 60 90 175 36
HSD03-352 35 20 50 135
HSD03-452 45 30 60 145
HSD03-552 55 40 70 200 312 219 155 90 4 26 3
HSD03-652 65 50 80 165
HSD03-752 75 60 90 175
HSD03-354 35 20 50 135
HSD03-454 45 30 60 145 24
HSD03-554 55 40 70 400 624 437 155 90 5 4
HSD03-654 65 50 80 165
26
HSD03-754 75 60 90 175
HSD03-356 35 20 50 135
HSD03-456 45 30 60 145
HSD03-556 55 40 70 600 936 655 155 90 6 34 4
HSD03-656 65 50 80 165
HSD03-756 75 60 90 175
HSD04-352 35 20 50 135
HSD04-452 45 30 60 145
HSD04-552 55 40 70 200 312 219 155 90 4 30 3
HSD04-652 65 50 80 165
HSD04-752 75 60 90 175
HSD04-354 35 20 50 135
HSD04-454 45 30 60 145 28
HSD04-554 55 40 70 400 624 437 155 90 5 4
HSD04-654 65 50 80 165
30
HSD04-754 75 60 90 175
HSD04-356 35 20 50 135
HSD04-456 45 30 60 145
HSD04-556 55 40 70 600 936 655 155 90 6 38 4
HSD04-656 65 50 80 165
HSD04-756 75 60 90 175
Your Fixing Systems Specialist | 42
Channel supports
HCSP1 HCSP2 HCSP3 HCSP4
Channel restraints
HCRS1 HCRS2 HCRS3 HCRS4
concrete beams with HCSP2 channel bearing beams with HCSP1 channel
• Fixing of channels in
the middle to the wall
1- Through Bolt
2- Channel Support
with channel restraints
3- Plain Washer are made to reduce
4- Washer deflection. Installation at
5- Nut horizontal Joints
6- Bolt Set Fdw/2 Fdw/2
7- Channel Restraint • When installation is
8- Channel at vertical joints, the
9- Anchor set
sub channel system
bears the whole load
of the slabs installed.
• When installation is
at horizontal joints, the
sub channel system
bears half the load of
the slabs installed.
HMPA U Channel
HZ02 Z Anchor
HMPB C Channel
HZ02 Z Anchor
Your Fixing Systems Specialist | 44
ATS-HZ Z Anchor
45
• Material: Stainless Steel 1.4301 (A2) & 1.4401 (A4) and Hot dip galvanized mild steel.
• Tables above is prepared according to values with Ø11 drilled holes.
• Channels can be provided up to 6 metres length.
• Load capacity for wind loads and dead loads needs to be verified with stuctural calculations.
Your Fixing Systems Specialist | 46
HCSP3-70 3 120 50 70 11 25 11 30
HCSP3-90 3 120 50 90 11 25 11 30
HCSP3-110 4 120 50 110 11 25 11 30
HCSP3-130 4 120 50 130 11 25 11 30
HCSP3-150 5 120 50 150 11 25 11 30
HCSP3-170 5 120 50 170 11 25 11 30
HCSP3-190 5 120 50 190 11 25 11 30
HCSP3-210 5 120 60 210 11 25 11 30
HCSP3-230 5 120 60 230 11 25 11 30
• Suitable only for HMPA type U channels & HMPL type L channels
• Max dead load 2.5 kN
• Max wind load 1.2 kN
• Material: Stainless Steel 1.4301 (A2) & 1.4401 (A4) and Hot dip galvanized ST37 mild steel.
47
HCRS3-70 3 40 50 70 11 25 11 30
HCRS3-90 3 40 50 90 11 25 11 30
HCRS3-110 4 40 50 110 11 25 11 30
HCRS3-130 4 40 50 130 11 25 11 30
HCRS3-150 5 40 50 150 11 25 11 30
HCRS3-170 5 40 50 170 11 25 11 30
HCRS3-190 5 40 50 190 11 25 11 30
HCRS3-210 5 40 60 210 11 25 11 30
HCRS3-230 5 40 60 230 11 25 11 30
• Suitable only for HMPA type U channels & HMPL type L channels
• Max wind load 1.2 kN
ATS-A ATS-B HMPS ATS-HA HZ-00 HCSP1 HCRS1 HMPC HMPC HZ01
Channel Channel Toothed Special Z Anchor Channel Channel C Channel C Channel Z Anchor
Support Restraint Channel Anchor Support Restraint
49
Fixing systems with aluminium channels are available for the installation of natural stone, ceramics and fibre cement panels. A variety of
systems are available to accommodate the application requirements . Custom designs are also made for special requirements. Three
dimensional adjustability is provided and fast installation is possible due to the light weight of aluminium and the ease of cutting and drilling
on site.
1 Channel support
2 Vert�cal U channel
3 Body anchor
4 Z Anchor
HMP-ALU-SP/H HMP-ALU-SP
Aluminium Sub Channel Aluminium Sub Channel
System System
Fixing systems for the installation of high load natural stone or reconstructed stone are available in a variety of types and size ranges. The
actual system proposal will be made according to the technical requirements of the project. The use of these fixing systems is for high load
coping and cornice stones. Load bearing and restraint anchors are used to install the slabs on to different wall backings using a variety
of attachment methods.
Application Examples
Restraint Anchors
HA-RST HA-RST/K HA-RST/K B HAZ21
Periscope Anchors
HPC1 HPC2 HPC3 HPC4
53
Restraining Brackets
Technical Details
Product Vertical Adjustable Straight
Reveal Size Wind Load
Code Load Arm Pin
Technical Details
Product Vertical Adjustable Straight
Reveal Size Wind Load
Code Load Arm Pin
Type B : With Welded Pin Type C : With Welded Plate Type D : With Welded Plate & Pins Type E : With Welded Shim
HFP Flanged Pin Technical Details HSW Serrated Washer Technical Details
Product Flange Product Thick-
Diameter Length Height Width Length
Code Diameter Code ness
HUP U Shaped Pin Technical Details HSM Shim Plate Technical Details
Product Product Thick- Slot
Diameter Height Width Height Width
Code Code ness Hole
HCP Capped Pin Technical Details HPT Plastic Tube Technical Details
Product Cap Product Inner Outer
Diameter Length Length
Code Diameter Code Diameter Diameter
• Material : Stainless Steel 1.4301 (A2) & 1.4401 (A4). Material for Plastic Tube: Polyacetal.
Your Fixing Systems Specialist | 56
Application
For fastening fixtures to
concrete strength class
C20/25 & solid
concrete block walls.
Available in
Stainless Steel EN
1.4301 & 1.4401 (AISI
304 & AISI 316) and
E.galvanized Mild
Steel.
Application
For fastening fixtures to
concrete strength class
C20/25 & solid
concrete block walls.
Available in
Stainless Steel EN
1.4301 & 1.4401 (AISI
304 & AISI 316) and Technical Details Working Resistance (kN)
E.galvanized mild steel. Min. Max.
Product Bolt Size Drill Hole Drill Fixture Max Bolt Thread C 20/25 Concrete
Embed- Fixture Wall
Code Dia. Length Hole Dia. Torque Length Length
ment Thickness
(mm) D (mm) HT (mm) E min. (mm) Smax (mm) D1 (mm) Mdmax(Nm) L (mm) LG (mm) Pullout Shear
Application
For fastening fixtures to
concrete strength class
C20/25 & solid
concrete block walls.
Available in
Stainless steel EN
1.4301 & 1.4401 (AISI
304 & AISI 316)
Application
For fastening fixtures to
concrete walls.
Available in
Stainless Steel EN
1.4301 & 1.4401 (AISI
304 & AISI 316) and
E.galvanized mild steel.
Application
For fastening fixtures to
concrete walls.
Available in
Stainless Steel EN
1.4301 & 1.4401 (AISI
304 & AISI 316) and
E.galvanized Mild
Steel.
Advantages E min
HT
• Higher pull out values
• Lower bending
moment on panel
• No appearence of
fixing at joints Technical Details Working Resistance (kN)
Product Min. Max. Hard Soft
Product Code Example Bolt Stone Drill Hole Drill
Embed- Fixture
Fixture Max Bolt Thread
Code Size Thickness Dia. Length Hole Dia. Torque Length Length Granite Marble
HB11 - 20 ment Thickness
(mm) St (mm) D/Du (mm) HT (mm) E min. (mm) Smax (mm) Df (mm) Mdmax(Nm) L (mm) (mm) Pullout Shear Pullout Shear
HB11-20 M6X27 20 8/11 12.50 11.50 5 9 5 24 14.5 1.20 1.20 1.00 1.00
ST Thick. 10/13 21.00 20.00 2.50 2.20 2.50 2.20
HB11-30 M8X37 30 5 9 12 34 14.5
Type HB11-40 M8X47 40 10/13 31.00 30.00 5 9 12 39 14.5 2.80 2.50 2.80 2.50
A safety factor of 3 is taken for mean ultimate failure loads.
Your Fixing Systems Specialist | 58
References
Project : Bibliotheca Alexandria Library - Alexandria Project : Texas Engineering University - Doha
Contractor : Balfour Beatty and Arab Contractors JV Contractor : Midmac Contracting
Installation Area : 40.000 m2 Installation Area : 60.000 m2
References
Project : Demir Bank Project : Yapi Kredi Project : Zorlu Holding Project : Istek Vakif Project : Tekfen Tower Project : Garanti Bank
Location : Istanbul Location : Istanbul Location : Istanbul Location : Istanbul Location : Istanbul Location : Istanbul
Project : Admo Apco Project : Emirates Towers Project : Fairmont Hotel Project : Zadgo Gasco Project : Trade Center
Location : Abu Dhabi Location : Dubai Location : Dubai Location : Abu Dhabi Location : Abu Dhabi
Project : American Embassy Project : American Embassy Project : American Embassy Project : American Embassy
Location : Istanbul Location : Kingston Location : Astana Location : Yerevan
Project : Usadba Center Project : Tax Office Project : Lazurnaya Project : Gasprom Project : Riverside Hotel Project : Ritz Carlton Hotel
Location : Moscow Location : Moscow Location : Sochi Location : Moscow Location : Moscow Location : Moscow
Project : Hilton Hotel Project : Kingdom Trade Project : Medinah Project : Four Seasons Hotel Project : The Fund Project : Mauritius Hotel
Location : Jeddah Location : Riyadh Location : Jeddah Location : Cairo Location : Abu Dhabi Location : Mauritius
HAZ Metal is certified with integrated management
HAZ Metal Sanayi ve Ticaret A.S.
systems by TUV SUD for ISO 9001 & OHSAS 18001
is a member of HAZ Group of Companies
HAZ PAZARLAMA İÇ & DIŞ TİC. A.Ş. HAZ METAL SANAYİ VE TİCARET A.Ş. HAZ METAL DEUTSCHLAND GmbH
İçerenköy Mh. Çayır Cd. Özce Center Şehit Er Çıracı Caddesi No. 10 Leonhard Karl Strasse 29
No:3 K:12 34752 Ataşehir Akçay Sanayi Bölgesi 31200 İskenderun 97877 Wertheim, Germany
İstanbul, TÜRKİYE Hatay, TÜRKİYE Tel : +49 (0) 9342 93590
Tel : +90 (0) 216 410 72 06 Tel : +90 (0) 326 626 20 50 Fax : +49 (0) 9342 935929
Fax : +90 (0) 216 410 71 41 Fax : +90 (0) 326 626 20 45 www.hazmetal.de
www.hazpazarlama.com www.hazmetal.com info@hazmetal.de
hazpazarlama@hazgrp.com info@hazmetal.com
HAZ INTERNATIONAL LTD. HAZ MARBLE INDUSTRY & TRADE LLC HAZ ASIA PACIFIC PTE LTD
154 Great North Road Hatfield First Gulf Building Corniche Street Blk 22 Woodlands Link #01-65
Herts. AL9 5JN England 2nd Floor, Flat No. 202 P.O. Box 5721 Singapore 738734
Tel : +44 (0) 1707 - 260 180 Abu Dhabi, United Arab Emirates Tel: +65 6853 7681
Fax : +44 (0) 1707 - 260 190 Tel : +971 (0) 2 622 07 00 Fax: +65 6752 9582
www.hazuk.co.uk Fax : +971 (0) 2 622 17 00 www.hazapac.com
haz@hazuk.co.uk www.hazuae.ae info@hazapac.com
hazuae@hazmarbleuae.ae
HAZ EGYPT LTD HAZ MARBLE QATAR WLL HAZ RUS LTD
Villa no.29-Third Floor.St.no.270 P.O.BOX 31296 C-Ring road 117036, Ul, Profsoyuznaya Dom 3 (office 531)
New Maadi, Cairo, Egypt Doha, Qatar Moscow, Russian Federation
Tel : +20 (2) 2447 09 85 Tel : +974 (4) 467 26 13-47 Tel : +7 (926) 672 31 84
www.hazeg.com Fax : +974 (4) 467 47 49 info@hazrus.ru
info@hazeg.com www.hazqatar.com www.hazrus.ru
hazdoha@hazqatar.com
Always at the forefront of fixing technology, HAZ METAL has earned a reputation as the leaders in fixing systems
innovation and is regarded as the one to follow. HAZ METAL fixing systems of today become the standard of
tomorrow.
HAZ METAL combines the very latest international technology with its own research and development team to
establish a technical excellence within the industry. HAZ METAL readily embraces the responsibility of a major
producer and shares its expertise with problem solving solutions.