PRODUCT DATA SHEET

Sikafloor®-264 SG
2-part High-build Solvent Free Epoxy Coating

DESCRIPTION FEATURES
Sikafloor®-264 SG is a two-part, high-build, solvent ▪ Good chemical and mechanical resistance
free, coloured epoxy resin. ▪ Easy application
Suitable for use in hot and tropical climatic conditions. ▪ Economical
▪ Liquid proof
USES ▪ Gloss finish
▪ High Slip resistant surface when broadcasted
Sikafloor®-264 SG may only be used by experienced
professionals. SUSTAINABILITY
Sikafloor®-264 SG can be used as a: ▪ Sikafloor®-264 SG is certified according "Low Emit-
▪ Roller coat for concrete and cement screeds with ting Materials as per Al Sa'fat - Dubai Green Building
normal up to medium heavy wear for example stor- Evaluation System" by Dubai Central Laboratory
age and assembly halls, maintenance workshops, (DCL), certificate No. CL17020432
garages and loading ramps. ▪ LEED Raiting: Sikafloor®-264 SG conforms to the re-
▪ A broadcast system for multi-storey and under- quirements of LEED EQ Credit 4.2: Low-Emitting Ma-
ground car parks, maintenance hangars and for wet terials: Paints and Coatings with VOC Content <100
process areas, for example beverage and food in- g/l
dustry. ▪ California Department of Public Health (CDPH) Meth-
od - VOC emission test: PASS

CERTIFICATES AND TEST REPORTS


▪ Certified by Dubai Civil Defence (DCD)

Product Data Sheet


Sikafloor®-264 SG
October 2023, Version 04.04
020811020020000065

1/6
PRODUCT INFORMATION
Composition Pigmented epoxy resin
Packaging Please refer to local country price list for available packaging sizes:
Part A (container) 4.12 kg 19.80 kg 23.10 kg
Part B (container) 0.88 kg 4.20 kg 4.90 kg
Part A + B (set) 5.00 kg 24.00 kg 28.00 kg

Shelf life 12 months from date of production.


Storage conditions Store in a dry area in original sealed packaging at temperatures between
+5 °C and +30 °C. Protect from direct sunlight, heat and moisture.
Appearance and colour Resin - Part A Coloured, liquid
Hardener - Part B Transparent, liquid
Available in various colour shades, please request Sika sales representative for col-
our chart.
Under direct sun light there might be some discolouration and colour variation
which have no influence on the function and performance of the coating.
Density Part A (at 23 °C) ~1.73 kg/l (DIN EN ISO 2811-1)
Part B (at 23 °C) ~1.00 kg/l
Mixed resin (at 23 °C) ~1.55 kg/l

Solid content by mass ~100 %


Note: Total solid epoxy composition acc. to the test method Deutsche Bauchemie e.V. (German Association
for construction chemicals)

Solid content by volume ~100 %


Note: Total solid epoxy composition acc. to the test method Deutsche Bauchemie e.V. (German Association
for construction chemicals)

TECHNICAL INFORMATION
Shore D Hardness ~80 (7 d / +23 °C) (ASTM D2240-15)

Abrasion resistance <50 mg (CS 17/1000/1000) (28 d / +23 °C) (ASTM D4060-14)
(Taber Abraser Test)

Resistance to impact ~1.5 kg-m (ASTM D2794-93)

Compressive strength ≥ 75 N/mm2 (28 d / +23 °C) (ASTM C579-18)

Tensile strength ~18 N/mm2 (28 d / +23 °C) (ASTM C307-18)

Tensile adhesion strength > 1.5 N/mm2 (failure in concrete) (BS 1881 Part 207)

Temperature resistance Exposure Dry heat


Permanent +50 °C
Short-term max. 7d +80 °C
Short-term max. 12 h +100 °C
Short-term moist / wet heat* up to +80 °C where exposure is only occasional
(steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
Water absorption ~0.05% (ASTM C413-01)

Chemical resistance Resistant to many chemicals. Please contact Sika's Technical Department
for chemical resistance table.

Product Data Sheet


Sikafloor®-264 SG
October 2023, Version 04.04
020811020020000065

2/6
SYSTEM INFORMATION
Systems Roller coating:
Primer*: 1 - 2 x Sikafloor®-161 (optional)
Coating: 2 x Sikafloor®-264 SG

Textured roller coating:


Primer*: 1 - 2 x Sikafloor®-161 (optional)
Coating: 1 - 2 x Sikafloor®-264 SG + Extender T

Textured roller coating with improved slip resistance:


Primer*: 1 - 2 x Sikafloor®-161 (optional)
Coating: 1 x Sikafloor®-264 SG + Extender T + Sikadur®-504

Broadcast system:
Primer*: 1 - 2 x Sikafloor®-161 (optional)
Base coat: 1 x Sikafloor®-264 SG
Broadcasting: Sikadur®-507 / Sikadur®-509
Sealer coat: 1 x Sikafloor®-264 SG

*Note: In cases of limited exposure and good sound low absorbent con-
crete substrates, priming with Sikafloor®-161 is not mandatory. It is recom-
mended to check the absorbency in case pinholes will occur.
Consumption Coating System Product Consumption
Primer 1 - 2 x Sikafloor® -161 0.25 - 0.40 kg/m2 per
coat
Levelling (optional) Sikafloor® PS or, Refer to relevant PDS
Sikafloor®-161 levelling
mortar
Roller coating 2 x Sikafloor®-264 SG 0.25 - 0.35 kg/m2 per
coat
Textured roller coating 1 - 2 x Sikafloor®-264 SG 0.5 - 0.8 kg/m2 per coat
+ Extender T 2-3%
Textured roller coating 10 pbw Sikafloor®-264 0.5 - 0.8 kg/m2
with improved slip res- SG + Extender T + 1 pbw 2 - 3 %
istance Sikadur®-504 0.05 - 0.07 kg/m2
Broadcast system Sikafloor®-264 SG + 0.25 - 0.30 kg/m2
broadcasting Sikadur®- 0.50 - 2.00 kg/m2
507 / Sikadur®-509 + 0.35 - 0.40 kg/m2
Sealcoat Sikafloor®-264
SG
These figures are theoretical and do not allow for any additional material
due to surface porosity, surface profile, variations in level and wastage etc.
Ambient air temperature +10 °C min. / +35 °C max.
Relative air humidity 80 % r.h. max.
Dew point Beware of condensation!
The substrate and uncured floor must be at least 3 °C above dew point to
reduce the risk of condensation or blooming on the floor finish.
Note: Low temperatures and high humidity conditions increase the prob-
ability of blooming.
Substrate temperature +10 °C min. / +35 °C max.
Substrate moisture content < 4 % pbw moisture content.
Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-meth-
od.
No rising moisture according to ASTM (Polyethylene-sheet).

Product Data Sheet


Sikafloor®-264 SG
October 2023, Version 04.04
020811020020000065

3/6
Pot Life Temperature Time
+10 °C ~60 min
+20 °C ~30 min
+30 °C ~15 min

Curing time Before applying Sikafloor®-264 SG on Sikafloor®-161 allow:


Substrate temperature Minimum Maximum
+10 °C 24 h 3d
+20 °C 12 h 2d
+30 °C 8h 1d
Before applying Sikafloor®-264 SG on Sikafloor®-264 SG allow:
Substrate temperature Minimum Maximum
+10 °C 30 h 3d
+20 °C 24 h 2d
+30 °C 16 h 1d
Times are approximate and will be affected by changes in ambient condi-
tions, particularly temperature and relative humidity.
Applied product ready for use Temperature Foot Traffic Light Traffic Full cure
+10 °C ~72 h ~6 d ~10 d
+20 °C ~24 h ~4 d ~7 d
+30 °C ~18 h ~2 d ~5 d
Note: Curing times are approximate and will be affected by changing ambi-
ent conditions

BASIS OF PRODUCT DATA IMPORTANT CONSIDERATIONS


All technical data stated in this Data Sheet are based ▪ Do not apply Sikafloor®-264 SG on substrates with
on laboratory tests. Actual measured data may vary rising moisture.
due to circumstances beyond our control. ▪ Freshly applied Sikafloor®-264 SG must be protected
from damp, condensation and water for at least 24
FURTHER INFORMATION hours.
▪ For areas with limited exposure and normally ab-
▪ General Method Statement sorbent concrete substrates priming with Sikafloor®-
Please refer to Sikafloor®-264 SG - General MS 161 is not necessary for roller or textured coating
▪ Substrate quality & Preparation systems.
Please refer to Sika Method Statement: “EVALUATION ▪ For roller / textured coatings: Uneven substrates as
AND PREPARATION OF SURFACES FOR FLOORING SYS- well as inclusions of dirt cannot and should not be
TEMS”. covered by thin sealer coats. Therefore both sub-
▪ Application instructions strate and adjacent areas must always be prepared
Please refer to Sika Method Statement: “MIXING & and cleaned thoroughly prior to application.
▪ The incorrect assessment and treatment of cracks
APPLICATION OF FLOORING SYSTEMS”.
may lead to a reduced service life and reflective
▪ Maintenance
cracking.
Please refer to “Sikafloor®- CLEANING REGIME”. ▪ For exact colour matching, ensure the Sikafloor®-264
SG in each area is applied from the same control
batch numbers.
▪ Under certain conditions, underfloor heating com-
bined with high point loading, may lead to imprints
in the resin.
▪ If heating is required do not use gas, oil, paraffin or
other fossil fuel heaters, these produce large quantit-
ies of both CO2 and H2O water vapour, which may
adversely affect the finish. For heating use only elec-
tric powered warm air blower systems.

Product Data Sheet


Sikafloor®-264 SG
October 2023, Version 04.04
020811020020000065

4/6
ECOLOGY, HEALTH AND SAFETY APPLICATION
Prior to application, confirm substrate moisture con-
User must read the most recent corresponding Safety tent, relative air humidity and dew point. If > 4 % pbw
Data Sheets (SDS) before using any products. The SDS moisture content, Sikafloor® EpoCem® may be applied
provides information and advice on the safe handling, as a T.M.B. (temporary moisture barrier) system.
storage and disposal of chemical products and con- Primer:
tains physical, ecological, toxicological and other Make sure that a continuous, pore free coat covers
safety-related data. the substrate. If necessary, apply two priming coats.
Apply Sikafloor®-151, Sikafloor®-161 and Sikafloor®-
APPLICATION INSTRUCTIONS 161 G by brush, roller or squeegee. Preferred applica-
tion is by using a squeegee and then backrolling cross-
SUBSTRATE QUALITY / PRE-TREATMENT wise.
▪ The concrete substrate must be sound and of suffi-
cient compressive strength (minimum 25 N/mm2) Levelling:
with a minimum pull off strength of 1.5 N/mm2. Rough or unlevelled surfaces need to be levelled first.
▪ The substrate must be clean, dry and free of all con- Use Sikafloor®-161 levelling mortar or Sikafloor® PS
taminants such as dirt, oil, grease, coatings and sur- (see Product Data Sheet) for minor thickness surface
face treatments, etc. leveling. For higher thickness leveling, use Sikafloor®-
▪ Concrete substrates must be prepared mechanically 190 Screed.
using abrasive blast cleaning or scarifying equipment Coating:
to remove cement laitance and achieve an open tex- Sikafloor®-264 SG as coating, can be applied by short-
tured surface. piled roller (crosswise).
▪ Weak concrete must be removed and surface defects Seal coat:
such as blow holes and voids must be fully exposed. Sealer coats can be applied by squeegee and then
▪ Repairs to the substrate, filling of blowholes/voids back-rolled (crosswise) with a short-piled roller.
and surface levelling must be carried out using ap-
propriate products from the Sikafloor®, Sikadur® and CLEANING OF EQUIPMENT
Sikagard® range of materials.
▪ All dust, loose and friable material must be com- Clean all tools and application equipment with Thinner
pletely removed from all surfaces before application C immediately after use. Hardened and/or cured ma-
of the product, preferably by brush or vacuum. terial can only be removed mechanically.

MIXING MAINTENANCE
Prior to mixing, stir part A mechanically. When all of CLEANING
part B has been added to part A, mix continuously for
3 minutes until a uniform mix has been achieved. To maintain the appearance of the floor after applica-
When parts A and B have been mixed, add the quartz tion, Sikafloor®-264 SG must have all spillages re-
sand and if required the Extender T and mix for a fur- moved immediately and must be regularly cleaned us-
ther 2 minutes until a uniform mix has been achieved. ing rotary brush, mechanical scrubbers, scrubber dry-
To ensure thorough mixing pour materials into anoth- er, high pressure washer, wash and vacuum tech-
er container and mix again to achieve a consistent mix. niques etc. using suitable detergents and waxes. For
Over mixing must be avoided to minimise air entrain- further details please refer to the Method Statement
ment. "Cleaning & Maintenance of Sikafloor® Systems".

MIXING TOOL LOCAL RESTRICTIONS


Sikafloor®-264 SG must be thoroughly mixed using a
low speed electric stirrer (300 to 400 rpm) or other Note that as a result of specific local regulations the
suitable equipment. For the preparation of mortars declared data and recommended uses for this product
use a forced action mixer of rotating pan, paddle or may vary from country to country. Consult the local
trough type. Free fall mixers should not be used. Product Data Sheet for exact product data and uses.

Product Data Sheet


Sikafloor®-264 SG
October 2023, Version 04.04
020811020020000065

5/6
LEGAL NOTES
The information, and, in particular, the recommenda-
tions relating to the application and end-use of Sika
products, are given in good faith based on Sika's cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika's recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which
will be supplied on request.

SIKA NORTHERN GULF SIKA SOUTHERN GULF Sika Saudi Arabia


Bahrain / Kuwait UAE / Oman / SIC Riyadh / Jeddah / Dammam
Tel: +973 177 38188 Tel: +971 4 439 8200 Tel. +966 11 217 6532
info@bh.sika.com info@ae.sika.com info@sa.sika.com
gcc.sika.com gcc.sika.com gcc.sika.com

Sikafloor-264SG-en-AE-(10-2023)-4-4.pdf

Product Data Sheet


Sikafloor®-264 SG
October 2023, Version 04.04
020811020020000065