Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SC Cee Uk 2023 Low

Download as pdf or txt
Download as pdf or txt
You are on page 1of 116

Catalogue UK

INDUSTRIAL PLUGS AND SOCKETS


„I’m proud to work for a company that treats everyone
with dignity and respect and operates free from
pretence or deceit. Integrity, honesty and sincerity are at the
heart of everything we do.”
Chris Stockdale, Managing Director MENNEKES UK

„Local service, availability, competence, excellent


products and the desire to provide tailored solutions are
MENNEKES’s factors for success in international markets.
This is what we provide in over 80 countries worldwide.”
Karsten Hauck, Head of International Sales

„We accelerate our company’s internationalisation


through close cooperation with our customers all over
the world. Client-oriented operations and efficient processes
lead to the best service and help us reach our goals with our
partners.“
Anne Schnieder-Sievers, Team Leader Customer Services Europe

We like to communicate with


you. Do you have special
requests and requirements?
Talk to us, we like to give
you advice and will provide
individual solutions for you.
Content
Page
1 About us

1
The company 4 - 7
Contact persons at MENNEKES in UK 8 - 9

2 Sockets
Wall mounted sockets 14 - 16
Wall mounted sockets switched and interlocked or fused 17 - 21
Sockets Cepex 22
Panel mounted sockets 23 - 26
Panel mounted sockets, switched and interlocked 27

3 Plugs and connectors


Plugs
Wall mounted inlets
Panel mounted inlets
33 -
35
36 -
34

37
2
Phase sequence test plugs 37
Phase inverter plugs 38
Accessories for plugs 38
Wall and panel mounted phase inverter inlets 39
Connectors 40 - 41

4 Combination units
AMAXX, wall mounted, IP44 47 - 49
AMAXX, wall mounted, IP67
Accessories for AMAXX
50 -
52
51
3
High resistance to chemicals, made of AMELAN 53
AMAXX supporter, suspended 54
DELTA-BOXES, Wall mounted combination units, Socket strips 55 - 57
EverGUM 59
Stainless steel 61

5 Special plugs and sockets


SCHUKO® and grounding-type 63 - 65

4
7 pole 67 - 68
600 V to 690 V 69
Special 1 h clock position 70
For low voltage 71 - 73
Isolating transformer 12 h 74
Energy and data 76 - 80
For reefer containers 82 - 84
TM for military purpose 85 - 86
Camping 87
Switch disconnectors 88
Hinged windows 89

6 Service 5
References 90 - 91
Regulations and standards 92 - 99
Drawings and Dimensions 100 - 111
Index of part numbers 112 - 115

6
„I am proud to be able
to continue this tradition
in the third generation.“
Christopher Mennekes, General Management Director

4 | MENNEKES www.MENNEKES.co.uk
MENNEKES – 1

The company.
When my grandfather, Aloys Mennekes, received his Master I am proud to be able to continue this tradition in the third
Electrician‘s certificate in 1935, he surely was not aware of what generation.
would develop from his commitment to electrical engineering.
These are fascinating times for the preservation of tradition
At that time, he knew only one thing: he wanted to put his ideas
because, due to the digital revolution, many things are going
into practice and manufacture his own products.
to change in the next decade. In this world flooded with
As you leaf through the pages of this catalogue, you get information, MENNEKES wants to be a point of reference on
a feeling of how strongly this initial entrepreneurial desire which our customers can rely for quality, safety and functionality.
continues to design us today. The variety of the products We say with confidence: Our brand is a promise.
on display clearly shows that we still have great pleasure in
Thank you for believing this promise and thus supporting our
converting our ideas into new products. But marketable ideas
business philosophy.
are rarely generated behind closed doors. As specialists,
we therefore develop individual solutions together with our
customers. Hence our product portfolio today consists of more Christopher Mennekes
than 10,000 customised products, far more than we can show in General Management Director
this catalogue.

Since it was founded over 80 years ago, MENNEKES has been


a wholly owned family business, responsibly managed by
members of the owning family throughout. Responsibility for the
Company also means responsibility for the people who are at
the heart of our thinking and actions at MENNEKES. Through
their awareness of the values of diligence, reliability and loyalty,
they constitute an important cornerstone of the Company.

Aloys Mennekes (center) with apprentice Plugs and sockets for toughest conditions Family Mennekes (from left): Petra and Walter, Daniela
and journeymen on their way to work and Christopher and Michael and Steffen

MENNEKES | 5
1 Quality –
Tested under extreme conditions.
When a MENNEKES product leaves our factory, it has already
survived the harshest testing. In our test lab it is exposed to cold,
heat, dust and water over and over again. Only the products
that withstand these tests are worthy of the name MENNEKES.
Our products are of course certified to national and international
standards by recognised institutions. Like the MENNEKES
company itself:
Our international quality management system is certified to
DIN EN ISO 9001.

Independent test organiza-


tions certify that our products
offer the highest levels of
safety, quality and trouble
free use.

Zertifikat
Certificate
für stückgeprüfte Qualität
nach DIN EN 61439.
for individually tested quality
according to IEC 61439.

Hiermit bestätigen wir, dass diese Steckdosen-Kombination


einer Stückprüfung unterzogen wurde.
Herewith we confirm that this receptacle combination has
passed a routine test.

Der MENNEKES-Sicherheitstest berücksichtigt nicht nur


die elektrischen Prüfanforderungen nach DIN EN 61439,
sondern beinhaltet darüber hinaus auch eine allpolige
Hochspannungsprüfung.
The MENNEKES safety test not just include the requirements
for electrical tests acc. to IEC 61439 but also a high voltage
test for all poles.

Only the combination of first-class raw materials and advanced manufacturing


Dietmar Löcker
We guarantee the high quality standard of our products by our own test
Bereichsleiter Qualität / Division Manager Quality
processes guarantee a premium product. This is why we use only first-grade laboratory. This laboratory is approved and will be used for product tests of
243000DS10T05.18V

MENNEKES Phone: +49 2723 41-1

plastics which are processed by a highly skilled workforce in state-of-the-art


Elektrotechnik GmbH & Co. KG
Aloys-Mennekes-Straße 1
Fax: +49 2723 41-214
our products to get test marks acc. to DIN EN 60309 by approval authorities
57399 KIRCHHUNDEM / GERMANY www.MENNEKES.de

production facilities to create certified MENNEKES products. like the VDE etc.
Zertifikat_243000DS_D_und_GB_Finale.indd 1 17.05.2018 11:05:28

6 | MENNEKES www.MENNEKES.co.uk
Regionally rooted – 1

At home around the world.


Everywhere, close to the customer: Our domestic market, You must be able to rely on MENNEKES. This is and remains
Germany, is supported from our corporate headquarters in the motivation of our 1,200 employees worldwide. It is they
Kirchhundem, as well as by sales agencies and our own field who, through their efforts on a daily basis, demonstrate the
service team. With our subsidiaries and sales offices, we are commitment to the MENNEKES brand.
represented by our own employees in the most important
international growth markets.

Germany
Kirchhundem & Neudorf Denmark
Great Britain Hejnsvig
London Russia
St. Petersburg Kazakhstan
Almaty

China
Suzhou
Italy Thailand
USA France Milan Bangkok
Fairfield Lyon
Vietnam
Ho Chi Minh City
Singapore
India Singapore
Chennai

Malaysia Indonesia
Seri Kembangan Jakarta

Subsidiaries: Representative Commercial agencies:


• Great Britain Offices: • 15 in Germany
• USA • Thailand • 29 in Europe
• China • Indonesia • 46 outside of Europe
• Singapore • Malaysia
• Italy • Kazakhstan
• France • Denmark
• Russia • Vietnam
• India

MENNEKES | 7
1 About us –
Contact persons at MENNEKES UK.
MENNEKES Electric Ltd. Management Team

Unit 4, Crayfields Industrial Park Chris Stockdale David Lumley


Main Road, St. Pauls Cray Managing Director Works Manager
Orpington, KENT BR5 3HP, UK Phone 01689 881 600 Phone 01689 833 522
Phone 01689 833 522 Fax 01689 833 378 Fax 01689 833 378
Fax 01689 833 378 christopher.stockdale@ david.lumley@MENNEKES.co.uk
sales@MENNEKES.co.uk MENNEKES.co.uk

Sales Office Team

Wendy Sargent Roy Choules Russell Massey


Accounts Department Internal Sales Internal Sales
Phone 01689 881 607 Phone 01689 833 522 Phone 01689 833 522
Fax 01689 881 601 Fax 01689 833 378 Fax 01689 833 378
wendy.sargent@MENNEKES.co.uk roy.choules@MENNEKES.co.uk russell.massey@MENNEKES.co.uk

Regional Sales Engineers

01 - North & Scotland 02 - Central 03 - Midlands 04 - South East


To be announced Paul O‘Brien Nigel Sheehan Andy Duddy
Phone +44 1689 833 522 Phone +44 1689 833 522 Phone +44 1689 833 522 Phone +44 1689 833 522
Mobile +44 7950 394015 Mobile +44 7793 220931 Mobile +44 7711 054819 Mobile +44 7704 156581
Fax +44 1689 833 378 Fax +44 1689 833 378 Fax +44 1689 833 378 Fax +44 1689 833 378
paul.obrien@mennekes.co.uk nigel.sheehan@mennekes.co.uk andy.duddy@mennekes.co.uk

05 - South West
Paul Brocklebank
Phone +44 1689 833 522
Mobile +44 7985 260180
Fax +44 1689 833 378
paul.brocklebank@mennekes.co.uk

8 | MENNEKES www.MENNEKES.co.uk
About us – 1

Regional Sales Areas.

01

01

02

03
04
05

MENNEKES | 9
Sockets – Product information

X-CONTACT
The future is now.
The new generation of contact sleeves.

As a specialist for plugs and sockets MENNEKES is known Less effort


all over the world for setting standards. In the past few years, The special design of the X-CONTACT reduces the effort of
we dealt intensively with current requirements of the electric insertion and withdrawal by up to 50 %. An advantage that simplifies
mobility and automotive sectors. We used the know-how work processes and improves safety especially with high electrical
gained to develop a completely new contact sleeve solution currents. With X-CONTACT, MENNEKES creates a safe contact
for industrial connectors and sockets: X-CONTACT closure and easy handling at a new, equally high level.

Better contact But how does X-CONTACT achieve these benefits even with
It is important to achieve the best possible balance between a currents of 63 A or 125 A? A glance into the opening of an
safe contact closure and ease of insertion. We have successfully X-CONTACT sleeve reveals the intelligent functional principle: the
implemented this with X-CONTACT in an entirely new way. X-shaped slot and groove in the inner wall provides four advantages
This technology is already used in our PowerTOP Xtra plugs and of the new design:
connectors in 16 to 125 A and our DUO wall mounted socket in 16 innovative, simple, durable and safe. We call it the X principle.
and 32 A.

Due to a completely new manufacturing process, the X-CONTACT


sleeve has resilient properties based solely on its material
characteristics, without the need to use any additional spring
elements. Thanks to the shape of the X-CONTACT sleeve, a
particularly safe contact closure can be achieved.

10 | MENNEKES www.MENNEKES.co.uk
Sockets – Product information

In our 63 and 125 A wall mounted and panel mounted sockets


and our DUO wall mounted sockets in 16 and 32 A.

Innovative Simple 2

Due to the slotted sleeves with their resilient In practice, X-CONTACT simplifies work
material properties, X-CONTACT is the simplest processes. The connection is easier to handle
possible mechanical solution: the plug pin simply when compared to conventional contact sleeves.
expands the opening of the resilient contact X-CONTACT – simply brilliant!
sleeve, which reduces the force needed to
connect and disconnect the plug by up to 50 %.
X-CONTACT – intelligently innovative!

Durable Safe

Even in cases when the plug is connected and A higher degree of safety of handling is provided
disconnected frequently, there are no signs by the easier connection and disconnection. The
of wear and the sleeve material remains groove within the inner wall in connection with the
fatigue-proof in the long term even after resilient material of the contact sleeves provides
rough handling. Due to the quality of the new for a safe contact closure.
sleeves, contamination and surface corrosion X-CONTACT – double safety!
is automatically removed by connecting and
disconnecting.
X-CONTACT – lasting solution!

Get more information on the new


generaton of contact sleeves at:
www.mennekes.co.uk/x-contact

MENNEKES | 11
Sockets – Product information

TwinCONTACT
The swift connection.
Looking for quick and easy connection?
You can’t miss the MENNEKES TwinCONTACT – a spring terminal in a newly designed socket. Remove the insulation, insert the conductors, and
you’re done. The contact is safely in place and it is even approved as a connection terminal – undo the conductor, that’s all it takes. Press
the red button and remove the conductor – this is our concept of convenient and time-saving handling.

Colour-coded terminals for unmistakable


2 connections.

Suitable for solid conductors and


flexible conductors (with end sleeve for
strands, crimped so as to be gas-tight or
ultrasonically welded).
Cond. cross section:
at 16 A: 1.5 - 4.0 mm²
at 32 A: 2.5 - 10.0 mm²

Sockets
with screw terminals.

Removable cover for easy All contact screws face the same
access to wiring space. way. Open terminals.
Terminals visible through slits.

12 | MENNEKES www.MENNEKES.co.uk
Sockets – Product information

DUO wall mounted socket


NEW
Fuse protection, switched and interlocked.

Machines and systems operate day and night, conveyor belts


run without pause and cranes work nonstop to lift and carry
materials weighing tons. Everywhere there‘s a need for safe reliable
power in order to work smoothly and cost-effectively.

Practical mounting plate


The mounting plate is removable for easy cable installation.
The socket and switch disconnector are on the mounting
plate and come prewired. You can also easily remove the
mounting plate with the socket and switch as a single unit
at any time, for example to place them on a firm surface for
maintenance work.

Practical aperture with hinged lid Lockout/tagout padlock for additional protection
For comfortable use and reliable operation without mishaps: Do you need to play it absolutely safe? The selector knob of every
the sockets hinged cap is easy to open and close. It opens DUO wall mounted sockets switch has a hole for attaching your own
upward instead of toward the wall. This prevents collisions with lockout/tagout padlock. This gives you added safety by preventing
connected cables and cable glands. the switch from being unintentionally turned on when a plug is in the
socket. The result is complete safety, for example for carrying out
maintenance tasks.

MENNEKES | 13
Sockets – Wall mounted, with screw terminals
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


external fixing 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 27001
16 4 27002 27003
16 5 27004
32 3 27005
IP44 32 4 27006 27007
Std. Pack. Qty: 10 32 5 27008
Drawing: 1 MB 463

2 Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


internal fixing, 4 p and 5 p sockets 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
the enclosure can be turned 180° 16 3 100 101 102 2169 2241
16 4 103 104 105 106 107
16 5 109 110 111 2000 2199

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 209

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


internal fixing, enclosure base can be 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
turned 180°, sockets are designed for 16 4 3030 3034 1418 3032 3035 3028
adding an auxiliary contact switch
16 5 3141 3045 1419 3043 3046 3039
32 3 1420 1421 1422 3139 3134
32 4 1423 1424 1425 1426 1427 1428
IP44 32 5 1555 1556 1557 3152 3154 3149
Std. Pack. Qty: 10
Drawing: 1 MB 43

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, suitable for through 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
wiring, internal fixing, enclosure 63 3 1136A 1137A
base can be turned 180°
63 4 1140A 1141A 1142A
63 5 1144A 1145A

IP44
Std. Pack. Qty: 5
Drawing: 1 MB 213

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly resistant to chemicals, with 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
2 external fixing points, enclosure 16 3 9300 9301 9302
base can be turned 180°, sockets
are designed for adding an auxiliary 16 4 9320 9321 9322 9323
contact switch 16 5 9341 9342
32 3 9350 9351 9352
IP67 32 4 9370 9371 9372 9373
Std. Pack. Qty: 10 32 5 9380 9381 9382
Drawing: 1 MB 622

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, internal fixing, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
enclosure base can be turned 180°, 63 3 856 128A 129A
with 6 fixing points to accommodate
special terminals 63 4 130A 131A 132A 133A
63 5 134A 135A 136A 2007A

IP67
Std. Pack. Qty: 5
Drawing: 1 MB 112

14 | MENNEKES www.MENNEKES.co.uk
Sockets – Wall mounted, with screw terminals
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, highly resistant to 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
chemicals, highly heat resistant 63 4 3773
contact carrier, nickel plated
contacts 63 5 3774

IP67
Std. Pack. Qty: 5
Drawing: 1 MB 112

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
X-CONTACT 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

125 4 137 138 139 140


125 5 142 143 2139

IP67
Std. Pack. Qty: 3
Drawing: 1 MB 162

High resistance to chemicals


High quality plastics.
For use in industrial premises or places of work where the use of chemicals or other aggressive substances makes it necessary to use other
plastic materials, MENNEKES offers products with increased stability against fuel, oil and grease, diluted acids and alkali, cleaner and the most
aqueous salt solutions. These products are marked in the catalogue with . Products made of AMELAN (grey RAL 7000 or light grey RAL 7035)
combine high mechanical, thermal and electrical properties with excellent dimensional stability and resistance to chemicals and are fit for action in
chemical plants, in refineries, in the food processing industry, in washdown areas and so on.

High resistance to:


• sea water
• detergents
• edible fat
• aqueous soap solution
• caustic soda
• motor oils
• milk
• caustic potash
• fruit juices
• diesel oil
• gasoline
• aqueous ammonia solution

MENNEKES | 15
Sockets – Wall mounted, screwless, with TwinCONTACT
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
external fixing 16 3 1340 1341
16 4 1342 1343 1344
16 5 31
32 3 1345 1346
IP44 32 4 1347 1348 1349
Std. Pack. Qty: 10 32 5 32
Drawing: 1 MB 463

2 Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
suitable for through wiring, internal 16 3 1719 1720 1721
fixing, 4 p and 5 p sockets the
16 4 1723 1724 1725 1727
enclosure base can be turned 180°
16 5 1730 3331

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 209

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
suitable for through wiring, 16 4 1750 1751 418 1752 1753 1754
internal fixing, enclosure base can
be turned 180° 16 5 1755 1756 419 1757
32 3 1851 420 1852
32 4 1856 421 1857 1858 1859
IP44 32 5 1860 1861 422 1862 1864
Std. Pack. Qty: 10
Drawing: 1 MB 43

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, highly 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
resistant to chemicals, suitable for 16 3 9104 9105 9106
through wiring, with 2 external fixing
points, sockets are designed for 16 4 9120 9121 9122 9123 9124 9125
adding an auxiliary contact switch, 16 5 9140 9141 9142
enclosure base can be turned 180°
32 3 9150 9151 9152
IP67 32 4 9171 9172 9173 9174
Std. Pack. Qty: 10 32 5 9180 9181 9182
Drawing: 1 MB 622

Double Box A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
CEE and socket SCHUKO® 16 5 1649
in one enclosure

IP67
Std. Pack. Qty: 10
Drawing: 1 MB 622

Double Box A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
CEE and socket SCHUKO® 16 5 1650
in one enclosure, with fuse holder,
32 5 1651
max. 10 A H, also available with
French/Belgian, Danish and Swiss
standards

IP44
Std. Pack. Qty: 5
Drawing: 1 MB 354

16 | MENNEKES www.MENNEKES.co.uk
Sockets – Wall mounted, switched and interlocked or fused
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

NEW Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V
screw terminals, pre-wired for 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
installation, X-CONTACT, switched, 16 3 5601304G 5601306G
mechanical DUO-interlock, 3 pole
switch, sockets can be padlocked 16 4 5601409G 5601406G 5601407G
16 5 5601506G 5601507G
32 3 5603304G 5603306G
IP44 32 4 5603404G 5603409G 5603406G 5603407G
Std. Pack. Qty: 1 32 5 5603509G 5603506G 5603507G
Drawing: 1 MB 713

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
X-CONTACT, switched, with 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
mechanical DUO-interlock 63 3 6571
63 4 5955A 5956A 5957A
63 5 5959A

IP44
Std. Pack. Qty: 1
Drawing: 1 MB 234

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock 16 3 7602 7603
16 4 7604 7605
16 5 7607
32 3 7612
IP44 32 4 7613 7614
Std. Pack. Qty: 1 32 5 7616
Drawing: 1 MB 550

NEW Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V
screw terminals, pre-wired for 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
installation, X-CONTACT, switched, 16 3 5602304G 5602306G
mechanical DUO-interlock, 3 pole
switch, sockets can be padlocked 16 4 5602406G 5602407G
16 5 5602506G
32 3 5604304G 5604306G
IP67 32 4 5604409G 5604406G 5604407G
Std. Pack. Qty: 1 32 5 5604509G 5604506G
Drawing: 1 MB 714

NEW Wall mounted socket R A P 110 V 230 V 400 V 500 V >50 - ​500 V
screw terminals, pre-wired for 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
installation, X-CONTACT, highly 16 3 5802306G
resistant to chemicals, switched,
mechanical DUO-interlock, highly 16 4 5802406G
heat resistant contact carrier, nickel 16 5 5802506G
plated contacts, 3 pole switch,
sockets can be padlocked 32 3 5804306G

IP67 32 4 5804406G
Std. Pack. Qty: 1 32 5 5804506G
Drawing: 1 MB 714

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
switched, with mechanical 63 3 5925A 5911A
DUO-interlock
63 4 5109A 5110A 5111A
63 5 5112A 5113A 5759A

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 180

MENNEKES | 17
Sockets – Wall mounted, switched and interlocked or fused
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, highly resistant to 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
chemicals, highly heat resistant 63 4 7289
contact carrier, nickel plated
contacts, with mechanical 63 5 7290
DUO-interlock

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 180

2 Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, switched, with 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
mechanical DUO-interlock 125 3 7000
125 4 5887A 5691A 5690A
125 5 5888A 5692A

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 177

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock 16 3 7620 7621
16 4 7624 7625
16 5 7626
32 3 7628 7629
IP67 32 4 7633 7634 7635
Std. Pack. Qty: 1 32 5 7636
Drawing: 1 MB 551

X-CONTACT
The new generation of contact sleeves.

Video:
X-CONTACT

Get more information on the new


generation of contact sleeves:
on pages 10/11 or at
www.mennekes.co.uk/x-contact

18 | MENNEKES www.MENNEKES.co.uk
Sockets – Wall mounted, switched and interlocked or fused
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly resistant to chemicals, highly 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
heat resistant contact carrier, nickel 16 3 7394
plated contacts, switched, with
mechanical DUO-interlock, DIN-rail 16 4 7291ZA
16 5 7292
32 5 7294
IP67
Std. Pack. Qty: 1
Drawing: 1 MB 181/620

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
X-CONTACT, highly resistant to 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
chemicals, highly heat resistant 63 4 7295
contact carrier, nickel plated
contacts, switched, with mechanical 63 5 7296
DUO-interlock, DIN-rail

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 181/620

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 RCD 30 mA 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 7123 7125
16 4 7126
16 5 7312
32 3 7469
IP44 32 4 7127
Std. Pack. Qty: 1 32 5 7313
Drawing: 1 MB 168

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 RCD 30 mA 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 7148
16 5 7150
32 5 7152

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 378

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 “C”-type MCB 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 910253

IP44
Std. Pack. Qty: 1
Drawing: 1 MB 531

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 RCD 30 mA 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
and 1 “C”-type MCB 16 5 920958
32 4 920961
32 5 920962

IP44
Std. Pack. Qty: 1
Drawing: 1 MB 521

MENNEKES | 19
Sockets – Wall mounted, switched and interlocked or fused
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 RCD 30 mA 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 910244
16 5 920838
32 3 920845

IP44
Std. Pack. Qty: 1
Drawing: 1 MB 531/ 1 MB 521

2 Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 RCD 30 mA 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
and 1 “C”-type MCB 16 3 910245 910584
16 5 920860
32 4 920863

IP44
Std. Pack. Qty: 1
Drawing: 1 MB 531/ 1 MB 521

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock, 16 3 921380 922452
protected by 1 RCD 30 mA
16 4 922517
16 5 922453
32 3 922519 921442
IP67 32 4 922518
Std. Pack. Qty: 1 32 5 922218
Drawing: 1 MB 521

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock, 16 3 931539
protected by 2 RCD´s 30 mA
32 3 934285
32 5 932285

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 522

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


protected by 1 RCD 30 mA 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 920700 920649
16 4 920791
16 5 920278
32 3 921160
IP67
Std. Pack. Qty: 1
Drawing: 1 MB 521

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly resistant to chemicals, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
protected by 1 RCD 30 mA 16 3 920821
16 5 923275
32 3 923276
32 4 923297
IP67
Std. Pack. Qty: 1
Drawing: 1 MB 521

20 | MENNEKES www.MENNEKES.co.uk
Sockets – Wall mounted, switched and interlocked or fused
to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111. Products with pilot contact available on request.

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
protected by 1 RCD 30 mA 63 3 920666
63 4 920668
63 5 920670

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 521

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock, protected by 16 3 7393UK 7245UK
1 RCD 30 mA
16 4 7246UK
16 5 7247UK
32 3 7434 7470UK
IP67 32 4 7248UK
Std. Pack. Qty: 1 32 5 7249UK
Drawing: 1 MB 181/620

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock, protected by 16 3 7252
1 RCD 30 mA and
1 ”K“-type MCB 16 4 7253
16 5 7254UK
32 4 7255
IP67 32 5 7256UK
Std. Pack. Qty: 1
Drawing: 1 MB 181/620

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
switched, with mechanical 63 3 7260
DUO-interlock, protected by
1 RCD 30 mA 63 4 7250
63 5 7251

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 181/620

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
switched, with mechanical 63 4 7257
DUO-interlock, protected by
1 RCD 30 mA and 63 5 7258
1 ”K“-type MCB

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 181/620

Wall mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
switched, with mechanical 125 5 5692AM
DUO-interlock, protected by
1 RCD 30 mA, add-on equipment is
required to install a padlock

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 177

MENNEKES | 21
Sockets – Cepex
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Wall mounted socket Cepex A P 110 V 230 V 400 V 500 V >50 - ​500 V
grey, amend index YA to part 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
number for version without rubber 16 3 4101 4102
gland
16 4 4254 4103 4104
16 5 4105
32 3 4106 4107
IP44 32 4 4108
Std. Pack. Qty: 5 32 5 4110
Drawing: 1 MB 312

2 Wall mounted socket Cepex A P 110 V 230 V 400 V 500 V >50 - ​500 V
grey, with labelling field 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 4132
16 4 4133
16 5 4135
32 3 4137
IP44 32 4 4138
Std. Pack. Qty: 5 32 5 4140
Drawing: 1 MB 317

Panel mounted socket Cepex A P 110 V 230 V 400 V 500 V >50 - ​500 V
pearl white 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 4111 4112
16 4 4233 4113 4114
16 5 4115
32 3 4116 4117
IP44 32 4 4118 4119
Std. Pack. Qty: 5 32 5 4120
Drawing: 1 MB 315

Flush mounted socket Cepex A P 110 V 230 V 400 V 500 V >50 - ​500 V
pearl white, with flush mounted 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
installation box 16 3 4122
16 4 4123
16 5 4125
32 3 4127
IP44 32 4 4128
Std. Pack. Qty: 5 32 5 4130
Drawing: 1 MB 336

Cepex double socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


grey, amend index YA to part 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
number for version without rubber 16 3 4219
gland
16 4 4220
16 5 4204
32 3 4224
IP44 32 5 4226
Std. Pack. Qty: 5/4
Drawing: 1 MB 350

N.B.: All above mentioned types are available in three designs and with SCHUKO® insert:
– with smooth cover
– with labelling field
– with labelling field and lockable cover
Also available with data port inserts. For products see page 77.
Distance frame on request.
Cepex range panel sockets rated 16 A and 32 A have the same dimensions.
It is, therefore, possible to interchange single or 3 phase sockets on a 2-gang enclosure to
suit your own requirements.

22 | MENNEKES www.MENNEKES.co.uk
Sockets – Panel mounted, with screw terminals
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.
Products with pilot contact available on request.

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


flange 75 x 75 mm, straight 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 1365 1366 1367 3054 3055


16 4 1388 1389 1390 1391 1392 1393
16 5 1384 1386 1385 3057 3059 3060
32 3 1394 1395 1396
IP44 32 4 1398 1399 1400 1401 1402
Std. Pack. Qty: 10 32 5 3449 3454 3451 3452 3455 3447
Drawing: 1 MB 464

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange 107 x 110 mm, straight 63 3 1260A 1261A
63 4 1247A 1248A 1249A
63 5 1252A

IP44
Std. Pack. Qty: 5
Drawing: 1 MB 211

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


flange 16 A, 3 p: 73.5 x 64 mm, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
16 A, 4 + 5 p, 32 A: 100 x 92 mm, 16 3 1462 1463 1464 3186 3187
inclination 20°, 32 A: sockets
optional fitted with auxiliary contact 16 4 1465 1466 1467 1468 1469 1470
16 5 1471 1472 1473 3188 3189 3190
32 3 1491 1492 1493 3201 3202
IP44 32 4 1494 1495 1496 1497 1486 1487
Std. Pack. Qty: 10 32 5 1498 1499 1500 3191 3192 3193
Drawing: 1 MB 260

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange 110 x 106 mm, 63 3 1146A 1147A 1148A
inclination 20°
63 4 1149A 1150A 1151A 1152A
63 5 1153A 1154A 1155A

IP44
Std. Pack. Qty: 5
Drawing: 1 MB 297

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


standard flange, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
dimensions 85 x 85 mm, 16 3 3031 3036
20° inclination
16 4 3072 3074
16 5 3093
32 3 3110 3112
IP44 32 4 3140 3136 3114
Std. Pack. Qty: 10 32 5 3153
Drawing: 1 MB 453

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


miniflange: 68 x 62 mm, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
inclination 20° 16 3 858 857

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 472

MENNEKES | 23
Sockets – Panel mounted, with screw terminals
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.
Products with pilot contact available on request.

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


flange 16 A: 75 x 75 mm, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
32 A: 85 x 75 mm, straight 16 3 217A 218A 219A
16 4 221A 222A 223A 224A
16 5 226A 227A 228A
32 3 229A 230A 231A
IP67 32 4 232A 233A 234A 235A 236A
Std. Pack. Qty: 10 32 5 239A 240A
Drawing: 1 MB 141

2 Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


flange 16 A, 3 p: 73.5 x 64 mm, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
16 A, 4 + 5 p, 32 A: 100 x 92 mm, 16 3 1474 1475 1476
inclination 20°, 32 A sockets
optional fitted with auxiliary contact 16 4 1477 1478 1479 1480 1481
16 5 1484 1485
32 3 1501 1502 1503
IP67 32 4 1504 1505 1506 1507
Std. Pack. Qty: 10 32 5 1490 1551
Drawing: 1 MB 251

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


standard flange dimensions 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
85 x 85 mm, inclination 20°, 16 3 903 905
optional fitted with auxiliary contact
16 4 1081 1082
16 5 1103
32 3 3197 3200
IP67 32 4 3254 3256
Std. Pack. Qty: 10 32 5 3524
Drawing: 1 MB 452

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange 63 A: 107 x 100 mm, 63 3 1263A 1264A 1265A
125 A: 130 x 130 mm, straight
63 4 1123A 1124A 1125A
63 5 1127A 1128A
125 3 3380
IP67 125 4 1455 1456 1457 1458
Std. Pack. Qty: 5 125 5 1460 1461 3283
Drawing: 1 MB 212/258

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange 63 A: 110 x 106 mm, 63 3 2179A 2180A 2181A
inclination 20°,
125 A: 114 x 110 mm, 63 4 203A 204A 205A 206A
inclination 15° 63 5 207A 208A 209A 3507
125 3 3575
IP67 125 4 211A 212A 213A
Std. Pack. Qty: 5 125 5 215A 216A
Drawing: 1 MB 298/601

Auxiliary contact
Part no.
for standard sockets
and panel mounted 41000
sockets 16 A and 32 A

Std. Pack. Qty: 10

24 | MENNEKES www.MENNEKES.co.uk
Sockets – Panel mounted, screwless, with TwinCONTACT
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange 75 x 75 mm, straight 16 3 1667 1668 1669 1671
16 4 1672 1673 1674 1675 1676 1677
16 5 1678 1679 3385 1680 1682
32 3 1786 1787 1788
IP44 32 4 1790 1791 1792 1793 1794
Std. Pack. Qty: 10 32 5 1795 1796 1797 1798 1800
Drawing: 1 MB 464

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange 16 A, 3 p: 73.5 x 64 mm, 16 3 1631 1632 1633 1635
16 A, 4 + 5 p, 32 A: 100 x 92 mm,
inclination 20°, 32 A: optional fitted 16 4 1637 1638 1639 1640 1641
with auxiliary contact 16 5 1642 1643 3473 1644 1646
32 3 1733 1734 1735 1737
IP44 32 4 1739 1740 1741 1742 1743
Std. Pack. Qty: 10 32 5 1744 1745 1746 1747 1749
Drawing: 1 MB 465

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
standard flange dimensions 16 3 3004 3008
85 x 85 mm, 20° inclination,
optional fitted with auxiliary contact 16 4 3048 3049
16 5 3070
32 3 3124 3126
IP44 32 4 3155 3157
Std. Pack. Qty: 10 32 5 3171
Drawing: 1 MB 519

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
miniflange: 55 x 55 mm, straight 16 3 1618 1619

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 426

MENNEKES | 25
Sockets – Panel mounted sockets, screwless, with TwinCONTACT
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange: 16 A: 75 x 75 mm, 16 3 1707 1708 1709
32 A: 85 x 75 mm, straight
16 4 1710 1711 1712 1713 1714
16 5 1716 1717 1131
32 3 1809 1810
IP67 32 4 1813 1814 1815
Std. Pack. Qty: 10 32 5 1818 1819 1820
Drawing: 1 MB 467

2 Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
flange: 16 A, 3 p: 73.5 x 64 mm, 16 3 1700 1701 1702
16 A, 4 + 5 p, 32 A: 100 x 92 mm,
inclination 20°, 32 A: optionally fitted 16 4 1703 1704 1705 1706
with auxiliary contact 16 5 3485
32 3 1801 1802 1803
IP67 32 4 1804 1805 1806
Std. Pack. Qty: 10 32 5 1808
Drawing: 1 MB 466

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with TwinCONTACT, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
standard flange dimensions 16 3 1168
85 x 85 mm, inclination 20°,
optionally fitted with auxiliary contact 16 4 1169 1171
16 5 1173
32 3 3566 3573
IP67 32 4 3581 3587
Std. Pack. Qty: 10 32 5 3590
Drawing: 1 MB 520

Auxiliary contact
Part no.
for standard sockets
and panel mounted 41000
sockets 16 A and 32 A

Std. Pack. Qty: 10

Auxiliary contact.
Function: Change-over contact = NC/NO
Connected load: 16 A (4 A)*/ ~ 250 V
10 A (3 A)*/ ~ 400 V
* for inductive or motor load

26 | MENNEKES www.MENNEKES.co.uk
Sockets – Panel mounted sockets, switched and interlocked
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock 16 3 7502 7503
16 4 7505
16 5 7507
32 3 7512
IP44 32 5 7516
Std. Pack. Qty: 1
Drawing: 5 MB 59

Panel mounted socket A P 110 V 230 V 400 V 500 V >50 - ​500 V


2
switched, with mechanical 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
DUO-interlock 16 3 7520 7521
16 4 7523 7524 7525
16 5 7526
32 3 7530 7531
IP67 32 4 7534 7535
Std. Pack. Qty: 1 32 5 7536
Drawing: 5 MB 57

MENNEKES | 27
Plugs and connectors – Product information

Our PowerTOP Xtra Family from 16 to 125 A.


Plugs and sockets for all applications.
In industrial applications, in mining, in railway and transport companies, in 16, 32, 63, and 125 A versions. Many of them have been proving
in ports, harbors, shipyards and campgrounds: in all of these situations themselves in practice in a wide variety of work environments worldwide
and many more, it‘s imperative to safely and reliably distribute electricity for years. All PowerTOP Xtra connectors feature our ingenious
in challenging or harsh conditions. As specialists for plugs and sockets, X-CONTACT contact sleeve technology.
we‘ve packed our formidable CEE know-how into a top-notch product
family for you. The PowerTOP Xtra plugs and connectors are available PowerTOP Xtra: plugs and connectors for professional electricians!

PowerTOP Xtra is a complete product family with solutions for every The new members of the PowerTOP Xtra family bring four success
application area. In this regard plugs and connectors 16 A and 32 A factors from professionals for professionals:
have been completely reworked and optimized in every detail!

Ergonomically optimized design

Simplified assembly

Easier and safer connection

Effortless connecting and disconnecting


with X-CONTACT

28 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Product information

Easier and safer connection


with ErgoCONTACT.
All products of the PowerTOP Xtra family are available with 16 and 32 A plugs and connectors. They enable easy, secure
screw terminals. We‘ve developed them further to create our and time-saving installation.
easy-to-use ErgoCONTACT connection technology for

3
3

1 2
1 Ergonomically effective installation
With ErgoCONTACT, you insert the screwdriver from
the top instead of from the side. This makes it easier
3 Guide collar
The screw trajectory is additionally supported by a
guide collar which prevents slide-off and minimises
to achieve the required torque and the pressure is the danger of injury.
applied directly from the grip. All of the screws point
in the same direction. This saves time, because it‘s no
longer necessary to rotate the front part in your hand
in order to tighten the contact screws of the individual
poles one after the other.
4 Captive combination head screw
Each contact has only one screw: a captive
combination head screw that is permanently
integrated in the guide collar in the factory and

2 Conductor insertion
Curved conductor guidance channels easily and
securely move the conductor ends into the contacts.
can be turned using either a Phillips or a flathead
screwdriver. Since only one screw has to be set for
each contact, installation is easy and time-saving.

MENNEKES | 29
Plugs and connectors – Product information

X-CONTACT
The new generation of contact sleeves.

Better contact
Due to a completely new manufacturing process, the
X-CONTACT sleeve has resilient properties based solely
on its material characteristics, without the need to use any
additional spring elements. Thanks to the shape of the
X-CONTACT sleeve, a particularly safe contact closure can
be achieved.

Less effort!
The special design of the X-CONTACT reduces the effort of insertion and withdrawal by up to 50%. An advantage that simplifies
work processes and improves safety especially with high electrical currents. With X-CONTACT, MENNEKES creates a safe contact
closure and easy handling at a new, equally high level.
Learn more about the new generation of contact sleeves at:
www.mennekes.co.uk/x-contact

30 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Product information

The X principle
Easy handling meets safe connections.
Innovative Simple
Slotted sleeves with their resilient material The connection is easier to handle when
properties reduces the force needed to compared to conventional contact sleeves.
connect and disconnect the plug by up to
50 %. X-CONTACT – simply brilliant!

X-CONTACT – intelligently innovative!

Durable Safe
No signs of wear, permanently A higher degree of safety of handling –
fatigue-proof and self-cleaning by for a safe contact closure.
connecting and disconnecting.
X-CONTACT – double safety!
X-CONTACT – lasting solution! 3

MENNEKES | 31
Plugs and connectors – Product information

AM-TOP and PowerTOP Xtra


for use in corrosive environments.

Highly heat resistant contact carrier and nickel plated contacts.


These appliances are guaranteed to be resistant to corrosive environments: High humidity, salt or acidic air, corrosive gases and vapours.
Accordingly, they are mainly used in the food processing industry, breweries, dairies, farms, market gardens and wineries.

AM-TOP
Phase inverter plug 16 A
and 32 A.
If three phase equipment rotates in the wrong direction
the phase inverter plug solves the problem rapidly and
safely. Release the lock with a screw-driver and turn the
insulating element in which the two phase pins are fitted.
Done - the motor will rotate in the correct direction.
Two outer conductors rotatable through 180°.

Angled plug VarioTOP


Ergonomic. Practical.
Safe.
The first CEE angled plug with cable entry rotating
up to 60° to the left or to the right.

32 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Plugs
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request.

Plug PowerTOP Xtra with A P 110 V 230 V 400 V 500 V >50 - ​500 V
ErgoCONTACT 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
ergonomic enclosure design with 16 3 13502
nubbed grip zones, rubberised
cable gland with sealing, strain relief 16 4 13506
and protection against kinking, 16 5 13509 13510 13511
thread lock and safety slide, area for
self-adhesive labels 32 3 13513
IP54 32 4 13516
Std. Pack. Qty: 10 32 5 13519 13520

Plug AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


single part body 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 247 249 2168 2271


16 4 250 251 253 254 255
16 5 2189 2243
32 3 259 261 2195 2341
IP44 32 4 262 263 265 266 267
Std. Pack. Qty: 10 32 5 2015 2244 2178

Plug PowerTOP Xtra S A P 110 V 230 V 400 V 500 V >50 - ​500 V


screwless, with insulation
displacement technology,
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
3
16 3 13521
ergonomic enclosure design with
nubbed grip zones, rubberised 16 5 13522
cable gland with sealing, strain relief 32 5 13523
and protection against kinking,
thread lock and safety slide
IP54
Std. Pack. Qty: 10

Plug PowerTOP Xtra R A P 110 V 230 V 400 V 500 V >50 - ​500 V


rubberised grip area, highly heat 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
resistant contact carrier, frame 63 3 13101 13102
terminals, nickel plated contacts,
cable gland and sealing, strain relief 63 4 13105 13106 13107
and protection against kinking 63 5 13111 13112

IP54
Std. Pack. Qty: 5

MENNEKES | 33
Plugs and connectors – Plugs
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request.

Angled plug VarioTOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


cable entry hood rotating up to 60° 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
to the left or the right, 16 5 3981 3980
3981 and 3980: in colour code
3983 and 3982: in electric grey 16 5 3983 3982

IP44
Std. Pack. Qty: 10

Angled plug A P 110 V 230 V 400 V 500 V >50 - ​500 V


with grommet 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 1410 1411
16 4 891 315
32 3 3312 3306
32 4 3646 3987
IP44 32 5 3424 3266
Std. Pack. Qty: 10

Plug AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


3 single part body, cable gland and
sealing, strain relief and protection
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 277 278 279


against kinking
16 4 280 281 282 283 284 285
16 5 286 287 288
32 3 289 290 291
IP67 32 4 292 293 294 295 296 297
Std. Pack. Qty: 10 32 5 298 299 300

Plug PowerTOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


with external cable grip, highly heat 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
resistant contact carrier and nickel 16 3 3794 3796 3799
plated contacts
16 4 3807 3811 3809 3810
16 5 3819 3823 3821
32 3 3829 3830 3832
IP67 32 4 3844 3841 3842
Std. Pack. Qty: 10 32 5 3851 3855 3853

Plug PowerTOP Xtra R with A P 110 V 230 V 400 V 500 V >50 - ​500 V
ErgoCONTACT 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
highly heat resistant contact carrier, 16 5 13561 13562 13563 13564 13565 13567
nickel plated contacts, ergonomic
enclosure design with nubbed grip 32 5 13582 13583 13584 13585 13586 13587
zones, rubberised cable gland with
sealing, thread lock and safety slide

IP54
Std. Pack. Qty: 10

Plug PowerTOP Xtra R A P 110 V 230 V 400 V 500 V >50 - ​500 V


rubberised grip area, highly heat 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
resistant contact carrier, frame 63 3 13201 13202 13203
terminals, nickel plated contacts,
cable gland and sealing, strain relief 63 4 13204 13205 13206 13207 13208 13209
and protection against kinking 63 5 13210 13211 13212 13213 13214
125 3 13215 13216
IP67 125 4 13217 13218 13219 13220
Std. Pack. Qty: 5 125 5 13223 13224 13225 13226 13227

34 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Wall mounted inlets
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Wall mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


for internal and external fixing, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
for hinged lids for retrofit see 16 3 843 844
part no. 41482 and 41489

IP44
Std. Pack. Qty: 10
Drawing: 2 MB 213

Wall mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


with hinged lid, for internal 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
and external fixing 16 3 846 847

IP44
Std. Pack. Qty: 10
Drawing: 2 MB 212

Wall mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


for external fixing,
for hinged lids for retrofit see
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
3
16 4 800
part no. 41482 and 41489
16 5 801
32 3 802
32 4 803
IP44 32 5 804
Std. Pack. Qty: 10
Drawing: 2 MB 221

Wall mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


enclosure base with stamped recess 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
for quick cutting out 16 3 331 332 333
16 4 334 335 336 337 921 922
16 5 340 341 342 2359 2668 2400
32 3 343 344 345
IP44 32 4 347 348 349
Std. Pack. Qty: 10 32 5 352 353 354 2386
Drawing: 2 MB 32

Wall mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


for a suitable watertight protective 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
cover for 63 A see part no. 40434 63 3 1216 1107 1217
63 4 355 356 357 358
63 5 359 360 361
125 4 362 363 364 365
IP67 125 5 367 368
Std. Pack. Qty: 5/3
Drawing: 2 MB 36

Hinged lid
Description Part no.
for retrofitting for wall mounted inlets
for part no. 843 and 844 41482
for part no. 800, 801 and 3517 41489

Std. Pack. Qty: 10

MENNEKES | 35
Plugs and connectors – Panel mounted inlets
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


16 A: flange 66 x 66 mm, fixing 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
distance 52 x 52 mm, 32 A: flange 16 5 1408
72 x 72 mm, fixing distance
60 x 60 mm, a retaining nose to 32 5 1409
hold the hinged lid of the connector
must be provided by the customer in
order to ensure satisfactory locking
IP44
Std. Pack. Qty: 10
Drawing: 2 MB 68

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


flange 75 x 75 mm, fixing distance: 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
60 x 60 mm, a retaining nose to 16 5 853
hold the hinged lid of the connector
must be provided by the customer
in order to ensure satisfactory
locking

IP44
Std. Pack. Qty: 10
Drawing: 2 MB 68/853

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


3 nickel plated contacts, a retaining
nose to hold the hinged lid of the
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 812
connector must be provided by
the customer in order to ensure 16 4 837 813 814
satisfactory locking 16 5 815
32 3 817
IP44 32 4 838 819 820
Std. Pack. Qty: 10 32 5 821
Drawing: 2 MB 173/2

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nickel plated contacts, a retaining 63 3 1981
nose to hold the hinged lid of the
connector must be provided by 63 4 1984 1982 824
the customer in order to ensure 63 5 1688
satisfactory locking

IP44
Std. Pack. Qty: 5
Drawing: 2 MB 155

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


nickel plated contacts, a retaining 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nose to hold the hinged lid of the 16 3 825 826
connector must be provided by
the customer in order to ensure 16 4 839 827 828
satisfactory locking 16 5 829
32 3 830 831
IP67 32 4 840 832 833
Std. Pack. Qty: 10 32 5 834
Drawing: 2 MB 187/2

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nickel plated contacts, 63 A: a 63 3 835 836
retaining nose to hold the hinged lid
of the connector must be provided 63 4 3704 3656 3657
by the customer in order to ensure 63 5 3658
satisfactory locking
125 3 3665
IP67 125 4 3413 3583 3600
Std. Pack. Qty: 5 125 5 1983
Drawing: 2 MB 166

36 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Panel mounted inlets, phase sequence test plugs
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 4 371 372 373


16 5 379
32 3 380 381
32 4 383 384 385 386
IP44 32 5 390 391
Std. Pack. Qty: 10
Drawing: 2 MB 73

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


with hinged lid 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 4 392 393 394 395


16 5 398 399 400
32 3 401 402 403
32 4 405 406 407
IP44 32 5 410 411 412
Std. Pack. Qty: 10
Drawing: 2 MB 43

Phase sequence test plug A P 110 V 230 V 400 V 500 V >50 - ​500 V
to VDE 0413, part 7,
DIN-EN 61557-7
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
3
16 4 3527 3458 3459
16 5 3231 1414
32 4 3528 3460 3461
32 5 3232 1415
IP44 63 4 3420 1436 3917
Std. Pack. Qty: 5 63 5 1437

Phase sequence test plug


Enables safe control of the direction of
the rotating field for CEE sockets.
According to VDE 0100-550 part 4.7 rotary current sockets must be connected such that a right-hand rotating field is achieved - the sockets
seen from front in clockwise direction.

The test plug differs from a standard plug by its transparent enclosure
indicating a right-hand or left-hand rotating field or a missing phase by
means of two control lamps.

Correct rotating field: Green lamp lights up.

Incorrect rotating field: Red lamp lights up.

Phase missing: Both lamps light up.

The control lamps inside the transparent enclosure are arranged so as


to be perfectly visible from all sides.

MENNEKES | 37
Plugs and connectors – Phase inverter plugs, accessories for plugs
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request.

Phase inverter plug AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V
single part body, cable gland and 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
sealing, strain relief and protection 16 4 338 339
against kinking
16 5 318 319
32 4 396 397
32 5 321 322
IP44
Std. Pack. Qty: 10

Phase inverter plug AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V
single part body 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 4 3338 3339
16 5 325
32 4 3340 3341
32 5 327 328
IP67
Std. Pack. Qty: 10

Protective cover
Description Part no.
3 for IP67 inlets and plugs
16 A, 3 p 40784
16 A, 4 p 40778
16 A, 5 + 7 p 40785
32 A, 3 + 4 p 40841
32 A, 5 + 7 p 40786
63 A, 3, 4 + 5 p 40787
Std. Pack. Qty: 50
125 A, 3, 4 + 5 p 40788

Plug guard
Part no.
prevents insertion of the plug
that unauthorised persons 41416
cannot use appliances or
installations

Std. Pack. Qty: 1

Plug guard.
Fits all CEE-plugs, panel mounted and wall mounted inlets from 16 A, 3 p up to 125 A, 5 p
(not suitable for low voltage).

38 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Phase inverter inlets
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Wall mounted phase inverter inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 4 3342 3343
16 5 2511
32 4 3345 3346
32 5 3347 2478
IP44
Std. Pack. Qty: 10
Drawing: 2 MB 32

Panel mounted phase inverter A P 110 V 230 V 400 V 500 V >50 - ​500 V
inlet 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 4 855
16 5 329
32 4 3368
32 5 913 330
IP44
Std. Pack. Qty: 10
Drawing: 2 MB 73

X-CONTACT 3

The new generation of contact sleeves.

Video:
X-CONTACT

Get more information on the new


generation of contact sleeves:
on pages 10/11 or at
www.mennekes.co.uk/x-contact

MENNEKES | 39
Plugs and connectors – Connectors
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. Products with pilot contact available on request.

Connector PowerTOP Xtra with A P 110 V 230 V 400 V 500 V >50 - ​500 V
ErgoCONTACT 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
X-CONTACT, ergonomic enclosure 16 3 14502
design with nubbed grip zones,
rubberised cable gland with sealing, 16 4 14506
strain relief and protection against 16 5 14509 14510 14511
kinking, thread lock and safety slide,
area for self-adhesive labels 32 3 14513
IP54 32 4 14516
Std. Pack. Qty: 10 32 5 14519 14520

Connector AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


single part body 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 509 511 2441 2517


16 4 512 513 515 516 517
16 5 2193 2495
32 3 521 523 2196 2674
IP44 32 4 524 525 527 528 529
Std. Pack. Qty: 10 32 5 530 531 2245 2493

Connector PowerTOP Xtra A P 110 V 230 V 400 V 500 V >50 - ​500 V


3 X-CONTACT,
rubberised grip area, frame
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

63 3 14101 14102
terminals, cable gland and sealing
63 4 14105 14106 14107
63 5 14111 14112

IP54
Std. Pack. Qty: 5

Angled Connector A P 110 V 230 V 400 V 500 V >50 - ​500 V


with grommet 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz

16 3 1438

IP44
Std. Pack. Qty: 10

40 | MENNEKES www.MENNEKES.co.uk
Plugs and connectors – Connectors
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. Products with pilot contact available on request.

Hanging connector PowerTOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


with highly heat resistant contact 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
carrier, cable gland and external 16 5 3778
cable grip, hanging clip
32 5 3999

IP44
Std. Pack. Qty: 10

Connector PowerTOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


with external cable grip and 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
highly heat resistant contact 16 3 3859 3860 3862
carrier
16 4 3873 3871 3872
16 5 3879 3883 3881
32 3 3887 3888 3891
IP67 32 4 3899 3897 3898
Std. Pack. Qty: 10 32 5 3909 3907

Connector AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


single part body, cable gland and
sealing, strain relief and protection
50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
3
16 3 539 540 541
against kinking
16 4 542 543 544 545 546
16 5 548 549 550
32 3 551 552 553
IP67 32 4 554 555 556 557 558
Std. Pack. Qty: 10 32 5 560 561 562

Connector PowerTOP Xtra R with A P 110 V 230 V 400 V 500 V >50 - ​500 V
ErgoCONTACT 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
X-CONTACT, ergonomic enclosure 16 5 14561 14562 14563 14565 14567
design with nubbed grip zones,
highly heat resistant contact carrier, 32 5 14582 14584 14585 14586 14587
nickel plated contacts, rubberised
cable gland with sealing, strain relief
and protection against kinking
IP54
Std. Pack. Qty: 10

Connector PowerTOP Xtra A P 110 V 230 V 400 V 500 V >50 - ​500 V


X-CONTACT, rubberised grip area, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
highly heat resistant contact carrier, 63 3 14201 14202 14203
frame terminals, cable gland and
sealing, strain relief and protection 63 4 14204 14205 14206 14207 14208 14209
against kinking 63 5 14210 14211 14212 14213 14214
125 3 14215 14216

IP67 125 4 14217 14218 14219 14220


Std. Pack. Qty: 5 125 5 14223 14224 14225 14226 14227

Hanging clip Description Part no.


for PowerTOP plugs and connectors
for 16 A, 3 to 5 p and 32 A, 3 + 4 p 15453000
for 32 A, 5 p 15452000

Std. Pack. Qty: 100

MENNEKES | 41
Combination units – Product information AMAXX

Success in series.
A new approach to combination units. Extensively configurable combination units in six different sizes – the AMAXX range by MENNEKES.
With an appealing and unique design in many variations for almost all applications.

The AMAXX combination with AMAXX Supporter – AMAXX combination and mounting unit
five segments completes the Our mounting unit AMAXX Supporter allows you to use our wall mounted AMAXX receptacle
program. We also feature combinations as a hanging combination unit. This way you effectively reach more areas of your
largescale combination units with factory or plant. The mounting unit has appropriate drill holes for front and back mounting of
all known AMAXX AMAXX combinations in 260 x 225 mm or 390 x 225 mm. The Supporter can selectively be
advantages. fitted with a pressurised air outlet and the respective maintenance unit, making it an individually
equipped supply station and a cost-efficient solution.

AMAXX s is the combination unit for restricted


installation in widths and depths. It can be optionally The smallest AMAXX combination unit with
attached on the side or swivel-mounted. one segment rounds off the program. It is
available in protection type IP44 and
IP67 as well as from 16 A, 3-pole up to
32 A, 5-pole and as AMAXX DUO
switched and interlocked.

The space-saver AMAXX s


AMAXX s is the optimum solution for restricted spaces.
Besides mounting on the rear, you can also mount it on the
right or the left thanks to the optionally available attachment
set. Or you opt for the variant that can be swivelled by
90 degrees on the left or the right for even more comfortable
application.

42 | MENNEKES www.MENNEKES.co.uk
Combination units – Product information AMAXX

AMAXX combination units by MENNEKES combine energy and data in one product family and have been highly successful for many years.

MENNEKES offers the right combination for each requirement: from the smallest AMAXX combination unit with one segment, through
the largest with five segments to the suspended combination unit. Fully configurable in six different enclosure dimensions and as
always in an attractive design. AMAXX by MENNEKES provides the electrician with almost infinite combination possibilities.

MENNEKES | 43
Combination units – Product information AMAXX

Variety of versions.
• Protection type: IP44 and IP67.
• Enclosure made of high-quality plastic or AMELAN in aggressive atmospheres with high resistance to chemicals as well as highly heat resistant
contact carrier and nickel plated contacts.
• Colours: bottom part black, top part grey (grey RAL 7035 (IP44) or yellow RAL 1021 available on request).
• Equipped with: CEE sockets from 16 A, 3 p up to 63 A, 5 p, grounding-type sockets in acc. with many national standards, DUO sockets
switched and interlocked from 16 A, 3 p up to 32 A, 5 p as well as fuse elements.

4
You can rely on it.

MENNEKES quality: tested and certified.


Like all other MENNEKES combinations, the AMAXX products are also subject to the extensive MENNEKES quality control. Each AMAXX
combination unit is thoroughly tested and certified prior to delivery.

Zertifikat
Certificate
für stückgeprüfte Qualität
nach DIN EN 61439.
for individually tested quality
according to IEC 61439.

Hiermit bestätigen wir, dass diese Steckdosen-Kombination


einer Stückprüfung unterzogen wurde.
Herewith we confirm that this receptacle combination has
passed a routine test.

Der MENNEKES-Sicherheitstest berücksichtigt nicht nur


die elektrischen Prüfanforderungen nach DIN EN 61439,
sondern beinhaltet darüber hinaus auch eine allpolige
Hochspannungsprüfung.
The MENNEKES safety test not just include the requirements
for electrical tests acc. to IEC 61439 but also a high voltage
test for all poles.

Dietmar Löcker
Bereichsleiter Qualität / Division Manager Quality
243000DS10T05.18V

MENNEKES Phone: +49 2723 41-1


Elektrotechnik GmbH & Co. KG Fax: +49 2723 41-214
Aloys-Mennekes-Straße 1
57399 KIRCHHUNDEM / GERMANY www.MENNEKES.de

Zertifikat_243000DS_D_und_GB_Finale.indd 1 17.05.2018 11:05:28


44 | MENNEKES www.MENNEKES.co.uk
Combination units – Product information AMAXX

Sophisticated details.
1 Liftable DIN rails.

3 Liftable DIN rails and a large, smooth wiring space


significantly ease the insertion as well as connection
of large cables.

2 One-man installation.
Shorter installation times with the new, user-friendly external
fixing.

3 Hinged cover.
The hinged cover, which opens to one side, eases
connection work.

1 4
4 Ready for application.
All combinations are pre-wired for installation and tested for
electric safety and quality.

4
•  enerally angled insertion
G • Keeps both hands free
direction, also with sockets because inspection windows
SCHUKO® fold downwards

• Especially fast opening and • Window can be locked with


closing of the enclosure due to a padlock, enclosure can be
captive double-threaded cover lead sealed
screws

MENNEKES | 45
Combination units – Product information AMAXX

Standard for low voltage switchgear and control gear assemblies - IEC 61439.

The standard IEC 61439 replaces IEC 60439 and describes the design and test specifications for low voltage switchgear and control gear
assemblies. The new standard has implications for the distribution of electrical energy in industry, domestic electrical installations and on
construction sites.

In the future two main standards will be required for each design of a low voltage switchgear and control gear assembly:
• the basic standard that is referenced as „Part 1“ in the specific standards;
• the applicable parts 2 to 7 of the switchgear and control gear assembly standard that deals with the particularities of the application.

The demands imposed on combination units that must be classified as a switchgear and control gear assembly have changed.
Structure and manner of verification have been redefined.

In the Service tab on pages 94 to 97 you will find additional information, excerpts from the standard for low voltage switchgear and control
gear assemblies - IEC 61439, and a listing of the agreements between manufacturers of the switchgear and control gear assemblies and users.

What has changed with the switchgear standard – IEC 61439 and what are the benefits for the MENNEKES customer?

• Product safety • Clear specifi cations


In the future, all low voltage switchgear and control gear Requests for a custom solution require clearly defined specifications
assemblies must be tested in accordance with IEC 61439. The by the user (such as installation site, ambient temperatures, etc.).
requirement of design verification is new. Design verification Your advantage: You get a need-based solution by MENNEKES
replaces the type test. MENNEKS combination units are tailored to the specific application.
subjected to additional standard-compliant routine tests. The
outgoing circuits are individually loaded with the respective
rated current. • Distinction:
Original manufacturer manufacturer If a product is modified on site,
Your advantage: This guarantees an even higher standard of the company in question is considered to be the manufacturer. In this
safety. case a new verification and documentation are required from this
company.

• Clear documentation Your advantage: For combination units that are prewired
Significant rating plate – clearly defined mandatory information, for installation, MENNEKES is the original manufacturer
4 such as rated diversity factor RDF (previously: simultaneity and manufacturer and therefore bears the complete product
factor). responsibility.

Your advantage: The main technical product information is


visible on the rating plate at a glance.

Example – rating plate

InA Rated current of the switchgear and


RDF Rated diversity factor
control gear assembly

Un Rated voltage Icc Conditional rated short-circuit current

fn Rated frequency Protection class


IP Ingress protection

46 | MENNEKES www.MENNEKES.co.uk
Combination units – Wall mounted, AMAXX
Pre-wired for installation (except part no. 910214 and 910394), IP44, enclosure front cover light grey RAL 7035, hinged to the side (except
enclosure size 130 x 225 mm and 650 x 112.5 mm). Fusing behind a transparent cover. For drawings and dimensions see page 109 - 110.

CEE sockets CEE sockets CEE sockets CEE sockets


2 CEE 16 A, 3 p, 110 V 1 CEE 16 A, 5 p, 400 V

4
CEE sockets CEE sockets CEE sockets CEE sockets
2 CEE 16 A, 3 p, 230 V

Sockets British standard Sockets British standard Sockets British standard Sockets British standard
3 x 13 A, 2 p+E, 230 V 2 x 13 A, 2 p+E, 230 V
Fusing Fusing Fusing Fusing
1 RCD 40 A, 4 p, 0.03 A 1 RCD 40 A, 4 p, 0.03 A
3 MCB´s 13 A, 1 p, C 1 MCB 16 A, 3 p, C
2 MCB´s 13 A, 1 p, C

Connection Connection Connection Connection


For 1 cable up to 5 x 10 mm2 For 2 cables up to 3 x 4 mm2 For 2 cables up to 3 x 4 mm2 For 1 cable up to 5 x 10 mm2

Connection and load values Connection and load values Connection and load values Connection and load values
Pre-fuse max. 63 A Pre-fuse max. 63 A
InA 39 A InA 28 A
RDF 1 RDF 0.95
Enclosure size Enclosure size Enclosure size Enclosure size
260 x 225 mm (H x W) 130 x 225 mm (H x W) 130 x 225 mm (H x W) 260 x 225 mm (H x W)
Part no. Part no. Part no. Part no.
921015 910214 910394 920286

MENNEKES | 47
Combination units – Wall mounted, AMAXX
Pre-wired for installation, IP44, enclosure front cover light grey RAL 7035, hinged to the side (except enclosure size 130 x 225 mm
and 650 x 112.5 mm). Fusing behind a transparent cover. For drawings and dimensions see page 109 - 110.

CEE sockets CEE sockets CEE sockets CEE sockets


1 CEE 16 A, 5 p, 400 V 2 CEE 16 A, 5 p, 400 V 1 CEE 16 A, 5 p, 400 V 2 CEE 16 A, 5 p, 400 V
Sockets, switched, with
4 mechanical DUO-interlock

CEE sockets CEE sockets CEE sockets CEE sockets

Sockets British standard Sockets British standard Sockets British standard Sockets British standard
2 x 13 A, 2 p+E, 230 V 2 x 13 A, 2 p+E, 230 V
Fusing Fusing Fusing Fusing
1 MCB 16 A, 3 p, C 2 MCB´s 16 A, 3 p, C 1 RCD 40 A, 4 p, 0.03 A 1 RCD 40 A, 4 p, 0.03 A
2 MCB´s 13 A, 1 p, C 1 MCB 16 A, 3 p, C 1 MCB 16 A, 3 p, C
1 MCB 13 A, 1 p, C

Connection Connection Connection Connection


For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2

Connection and load values Connection and load values Connection and load values Connection and load values
Pre-fuse max. 63 A Pre-fuse max. 100 A Pre-fuse max. 63 A Pre-fuse max. 63 A
InA 29 A InA 32 A InA 29 A InA 16 A
RDF 1 RDF 1 RDF 1 RDF 1
Enclosure size Enclosure size Enclosure size Enclosure size
260 x 225 mm (H x W) 390 x 225 mm (H x W) 650 x 112.5 mm (H x W) 260 x 225 mm (H x W)
Part no. Part no. Part no. Part no.
920464 931227 960043 920860

48 | MENNEKES www.MENNEKES.co.uk
Combination units – Wall mounted, AMAXX
Pre-wired for installation, IP44, enclosure front cover light grey RAL 7035, hinged to the side (except enclosure size 130 x 225 mm
and 650 x 112.5 mm). Fusing behind a transparent cover. For drawings and dimensions see page 109 - 110.

CEE sockets CEE sockets CEE sockets


2 CEE 16 A, 5 p, 400 V 1 CEE 32 A, 5 p, 400 V 1 CEE 63 A, 5 p, 400 V
1 CEE 16 A, 5 p, 400 V 1 CEE 32 A, 5 p, 400 V
1 CEE 16 A, 5 p, 400 V 4
CEE sockets CEE sockets CEE sockets

Sockets British standard Sockets British standard Sockets British standard


2 x 13 A, 2 p+E, 230 V 2 x 13 A, 2 p+E, 230 V
Fusing Fusing Fusing
2 RCD´s 40 A, 4 p, 0.03 A 1 RCD 40 A, 4 p, 0.03 A 1 RCD 63 A, 4 p, 0.03 A
1 MCB 32 A, 3 p, C 1 MCB 32 A, 3 p, C
1 MCB 16 A, 3 p, C 1 MCB 16 A, 3 p, C
2 MCB´s 13 A, 1 p, C 2 MCB´s 13 A, 1 p, C

Connection Connection Connection


For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 16 mm2 For 1 cable up to 5 x 16 mm2

Connection and load values Connection and load values Connection and load values
Pre-fuse max. 16 A Pre-fuse max. 40 A Pre-fuse max. 63 A
InA 16 A InA 40 A InA 63 A
RDF 1 RDF 0.85 RDF 0.65
Enclosure size Enclosure size Enclosure size
260 x 225 mm (H x W) 390 x 225 mm (H x W) 520 x 225 mm (H x W)
Part no. Part no. Part no.
920851 931234 941137

MENNEKES | 49
Combination units – Wall mounted, AMAXX
Pre-wired for installation, IP67, enclosure front cover light grey RAL 7035, hinged to the side (except enclosure size 130 x 225 mm and
650 x 112.5 mm). Fusing behind a transparent cover. For drawings and dimensions see page 109 - 110.

CEE sockets CEE sockets CEE sockets CEE sockets


2 CEE 16 A, 3 p, 110 V

4
CEE sockets CEE sockets CEE sockets CEE sockets
2 CEE 16 A, 3 p, 230 V 2 CEE 16 A, 3 p, 230 V 2 CEE 16 A, 3 p, 230 V

Sockets British standard Sockets British standard Sockets British standard Sockets British standard

Fusing Fusing Fusing Fusing


1 RCD 25 A, 2 p, 0.03 A 1 RCD 25 A, 2 p, 0.03 A 1 RCD 25 A, 2 p, 0.03 A
1 MCB 16 A, 1 p, C

Connection Connection Connection Connection


For 1 cable up to 3 x 10 mm2 For 1 cable up to 3 x 10 mm2 For 1 cable up to 3 x 10 mm2 For 1 cable up to 3 x 10 mm2

Connection and load values Connection and load values Connection and load values Connection and load values
Pre-fuse max. 16 A Pre-fuse max. 63 A Pre-fuse max. 16 A
InA 25 A InA 16 A InA 25 A
RDF 1 RDF 1 RDF 1
Enclosure size Enclosure size Enclosure size Enclosure size
130 x 225 mm (H x W) 260 x 225 mm (H x W) 260 x 225 mm (H x W) 260 x 225 mm (H x W)
Part no. Part no. Part no. Part no.
910355 920700 920714 920649

50 | MENNEKES www.MENNEKES.co.uk
Combination units – Wall mounted, AMAXX
Pre-wired for installation, IP67, enclosure front cover light grey RAL 7035, hinged to the side (except enclosure size 130 x 225 mm and
650 x 112.5 mm). Fusing behind a transparent cover. For drawings and dimensions see page 109 - 110.

CEE sockets
2 CEE 32 A, 5 p, 400 V
Sockets, switched, with
mechanical DUO-interlock 4
2 CEE 16 A, 5 p, 400 V

CEE sockets

Sockets British standard

Fusing
1 RCD 63 A, 4 p, 0.03 A
2 MCB´s 32 A, 3 p, C
1 MCB 16 A, 3 p, C

Connection
For 1 cable up to 5 x 16 mm2

Connection and load values


Pre-fuse max. 63 A
InA 58 A
RDF 0.6
Enclosure size
260 x 225 mm (H x W)
Part no.
900946

MENNEKES | 51
Combination units – Accessories, wall mounted
Accessories for AMAXX combination units.

AMAXX standard AMAXX AMAXX AMAXX


cable glands screw set attachment set support/carrier frame

deep black RAL 9005 consisting of for lateral installation signal yellow RAL 1003,
4 screws 6 x 70 mm of AMAXX s combinations, for suitable for AMAXX
M 20 - for cable from 6-13 mm Pozidrive size 3, steel mounting either on the left or combination units
IP44: Part no. 990607 galvanized and right hand side with the sizes:
IP67: Part no. 990611 4 dowels 8 x 50 mm, for (set of 2 for 1 combination) 260 x 225 mm,
concrete, porous concrete, solid 390 x 225 mm and
M 25 - for cable from 9-17 mm brick, perforated brick 520 x 225 mm
IP44: Part no. 990610 for wall mounting in
protection type IP67 or as
M 32 - for cable from 13-21 mm mobile combination units with
IP44: Part no. 990608 carrying handle and with
IP67: Part no. 990612 feeder cable in protection
type IP44 and IP67
M 40 - for cable from 14-28 mm
IP67: Part no. 990609

Part no. 990606 Part no. 990620 Part no. 15696

Selection chart for membrane cable glands


4 AMAXX Standard Recommandation of usage
combination units cable entries membrane cable gland*

with 1 segment top: 2 x M 25 1 x M 25 alternative: 1 x M 20


Enclosure: 2 x M 20
130 x 225 mm (H x W) bottom: 2 x M 25
2 x M 20
with 2 segments top: 2 x M 32 1 x M 32 alternative: 2 x M 20
Enclosure: 2 x M 20
230 x 225 mm (H x W) bottom: 2 x M 32
AMAXX membrane 2 x M 20
cable glands
with 3 segments top: 2 x M 40 1 x M 40 alternative: 2 x M 20
deep black RAL 9005, Enclosure: 2 x M 20
incl. blanking plug 390 x 225 mm (H x W) bottom: 2 x M 40
2 x M 20
M 25 - for cable from 9-17 mm
with 4 segments top: 2 x M 40 1 x M 40 and 1 x M 20 alternative: 3 x M 20
Part no. 990623
Enclosure: 2 x M 20
520 x 225 mm (H x W) bottom: 2 x M 40
M 32 - for cable from 13-21 mm
2 x M 20
Part no. 990625
with 5 segments top: 2 x M 40 1 x M 40 and 2 x M 20 alternative: 4 x M 20
M 40 - for cable from 16-28 mm Enclosure: 2 x M 20
Part no. 990627 650 x 225 mm (H x W) bottom: 2 x M 40
2 x M 20
* At least required for the following ambient conditions:
Reduction of the ambient temperature by 45 °C through 10-minutes of heavy rain (enclosure, e.g heated to
60 °C through sunlight, subsequent cloudburst with water temperature of 15 °C).
If temperature differentials are greater/less, accordingly more or fewer membrane cable glands must be
used.

52 | MENNEKES www.MENNEKES.co.uk
Combination units – Wall mounted, AMAXX
Highly resistant to chemicals made of AMELAN, pre-wired for installation, IP44 and IP67, enclosure front cover grey
RAL 7000, hinged to the side (except enclosure size 130 x 225 mm and 650 x 112.5 mm).
Fusing behind a transparent cover. For drawings and dimensions see page 109 - 110.

CEE sockets CEE sockets CEE sockets


1 CEE 32 A, 5 p, 400 V 1 CEE 32 A, 5 p, 400 V
1 CEE 16 A, 5 p, 400 V
4
CEE sockets CEE sockets CEE sockets
2 CEE 16 A, 3 p, 230 V

Sockets British standard Sockets British standard Sockets British standard


3 x 13 A, 2 p+E, 230 V
Fusing Fusing Fusing
1 RCD 63 A, 4 p, 0.03 A 1 RCD 25 A, 2 p, 0.03 A 1 RCD 40 A, 4 p, 0.03 A
1 MCB 32 A, 3 p, C
1 MCB 16 A, 3 p, C
3 MCB´s 13 A, 1 p, C

Connection Connection Connection


For 1 cable up to 5 x 16 mm2 For 1 cable up to 3 x 10 mm2 For 1 cable up to 5 x 10 mm2

Connection and load values Connection and load values Connection and load values
Pre-fuse max. 63 A Pre-fuse max. 63 A Pre-fuse max. 32 A
InA 63 A InA 63 A InA 63 A
RDF 0.75 RDF 0.75 RDF 0.75
Enclosure size Enclosure size Enclosure size
520 x 225 mm (H x W) 260 x 225 mm (H x W) 260 x 225 mm (H x W)
Part no. Part no. Part no.
941142 920821 921024

MENNEKES | 53
Combination units – Suspended, Supporter
Mounting unit made from light metal.
Installation according to ingress protection classes IP44 and IP67 available.

Mounting unit Pneumatic maintenance unit Pneumatic connection

Hangable mounting unit, made ¼“ pre-assembled single,


from light metal, with holes for inlet pressure max. 16 bar, ​ 1 quick coupling ​¼“,
front and rearinstallation of 1 oil mist lubricator, ​ connection: 1 hreaded nozzle of
sockets and combination units water separator 0 - 10 b ​ ar, 9 mm
2 enclosures 260 x 225 mm​ pressure reducer with pressure
2 enclosures 390 x 225 mm gauge,
dimensions (H x D x W): 1 quick coupling ¼“, ​
535 x 233 x​ 348 mm connection: 1 threaded nozzle of
colour: 9 mm
grey (RAL ​9006)

Part no. 18444 Part no. 18431 Part no. 18430

Drilled holes to
4 accommodate the 4 round
steel chains which are
held together with a 6 mm
Bohrungen zur Aufnahme der
karbiner. Zeichnung
Rundstahlketten,
With holesdie obenandmit
for front 1 MB 451
rearinstallation for AMAXX
einemcombination
6mm Karabinerhaken
units
Maße in mm
zusammengehalten
260 x 225 mm or
390 x 225 mm.
werden.
235
535

passend vorgebohrt
450

für die vorder- und


rückseitige Montage von
260 x 225 mm oder
390 x 225 mm
348 1 MB 451
Bestelnr. 18444

Power distributor for electricity and pressurised air. A fast and


cost-efficient solution with individual configuration with combination
units and compressed air equipment.

Includes a 350 mm chain set for ceiling installation.

54 | MENNEKES www.MENNEKES.co.uk
Combination units – DELTA-BOX
Pre-wired for installation, IP441) / 67 1)
Regarding portable combination units in IP44 please see page 99 for further information.
With cable grip and installed hanging hook. Other combination units on request. Dimensions page 111.

Fitted with Fitted with Fitted with Fitted with


3 CEE 16 A, 5 p, 400 V 3 CEE 32 A, 5 p, 400 V 1 CEE 16 A, 5 p, 400 V 2 CEE 16 A, 5 p, 400 V
3 SCHUKO® 16 A, 230 V 1 CEE 16 A, 5 p, 400 V

Fusing Fusing Fusing Fusing


1 RCD 25 A, 2 p, 0.03 A

Connection Connection Connection Connection


For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2

Connection and load values Connection and load values Connection and load values Connection and load values

Protection type Protection type Protection type Protection type


IP44 IP44 IP44 IP44
Part no. Part no. Part no. Part no.
92917 90839 92658 92893
4

DELTA-BOX
the classic unit.
With cable grip. Each DELTA-BOX comes with a suspension bracket.
Available in IP44, IP67 and IP68.

MENNEKES | 55
Combination units – Wall mounted combination units
Pre-wired for installation, IP44 / 45, enclosure front cover light grey RAL 7035, Fusing behind a transparent cover. For drawings and dimensions see
page 107.

CEE sockets CEE sockets


1 CEE 63 A, 5 p, 400 V 1 CEE 32 A, 5 p, 400 V
1 CEE 32 A, 5 p, 400 V
4 CEE sockets CEE sockets
1 CEE 32 A, 3 p, 230 V 1 CEE 16 A, 3 p, 230 V

CEE sockets CEE sockets


1 CEE 16 A, 3 p, 100-130 V 1 CEE 16 A, 3 p, 100-130 V

Fusing Fusing
1 RCD 63 A, 4 p, 0.03 A 1 RCD 40 A, 4 p, 0.03 A
1 RCD 40 A, 4 p, 0.03 A 1 RCD 25 A, 2 p, 0.03 A
1 RCD/MCB 32 A, 1 p+N, C, 0.03 A 1 RCD 25 A, 2 p, 0.03 A
1 RCD 25 A, 2 p, 0.03 A 1 MCB 32 A, 3 p, C
1 MCB 63 A, 3 p, C 1 MCB 16 A, 2 p, C
1 MCB 32 A, 3 p, C 1 MCB 16 A, 1 p, C
1 MCB 10 A, 1 p, D 1 MCB 10 A, 1 p, D
1 MCB 10 A, 2 p, C 1 Switch Disconnector 63 A, 3 p
1 Single-Phase Transformer 1 Single-Phase Transformer
230V/110V (55-0-55V) 1.8KVA 230V/110V (55-0-55V) 1.8KVA

Connection Connection
For 1 cable up to 5 x 35 mm2 For 1 cable up to 5 x 16 mm2

Connection and load values Connection and load values


Pre-fuse max. 63 A
InA 42 A
RDF 0.75
Enclosure size Enclosure size
460 x 260 mm (H x W) 460 x 260 mm (H x W)
Part no. Part no.
8063261 8067864

56 | MENNEKES www.MENNEKES.co.uk
Combination units – Socket strips
Pre-wired for installation, IP441) / 67 1)
Regarding portable combination units in IP44 please see page 99 for further information.
Other combinations on request. For drawings and dimensions see page 111.

Fitted with Fitted with Fitted with Fitted with


3 CEE 16 A, 5 p, 400 V 2 CEE 16 A, 5 p, 400 V 3 CEE 16 A, 3 p, 110 V 3 CEE 16 A, 3 p, 230 V
1 SCHUKO® 16 A, 230 V

Fusing Fusing Fusing Fusing


1 RCD 0.03 A

Connection Connection Connection Connection


For 1 cable up to 5 x 10 mm2 For 1 cable up to 5 x 10 mm2 For 1 cable up to 3 x 10 mm2 For 1 cable up to 3 x 10 mm2

Connection and load values Connection and load values Connection and load values Connection and load values

Protection type Protection type Protection type Protection type


IP44 IP44 IP44 IP44
Part no. Part no. Part no. Part no.
95472 96703 96227 96489
4

Socket strips
the versatile units.
Suspendable, portable or for wall mounting. Pre-wired for installation.
With cable gland. Available in IP44.

MENNEKES | 57
Combination units – Product information EverGUM

EverGUM
Flexible safety.
With the EverGUM range MENNEKES provide
a solid rubber alternative to enclosures in
plastics and sheet steel. This is an alternative
which is suitable for the most diverse
environments, especially when there is
likely to be exposure to rough handling or
aggressive cleaning agents. These products
can also be supplied to conform to the
standards of other European countries.

The outstanding advantages:


• Resistant to weather and ageing
• High dimensional stability and precision
• Good resistance to acids and alkalis
• High dieletric strength and creep
resistance

The allround power-packages for mobile


use in industry, craft and trade. They can
accept quite a knock – neither their design
4 nor their function will be impaired. Additional
benefit: they are stackable which allows
space-saving storage.

Tested safety, EverGUM details. Socket strip EverGUM.


The closed lower side of the enclosure with a ground clearance of 77 mm prevents ingress of Window size for six or eight modules for
water. The panel mounted sockets can be replaced from outside. Hinged cover provided with vertical installation.
stainless steel quick release clips. MCBʼs and in RCD´s are immediately accessible after opening
the lid. All energised parts even with the lid open are covered so that they are contact safe – in
accordance with BGV A3. Screw or padlock offers additional safety.

58 | MENNEKES www.MENNEKES.co.uk
Combination units – EverGUM
Pre-wired for installation, IP441) 1)
Regarding portable combination units in IP44 please see page 99 for further information.
Fusing behind a transparent cover. Colour: signal yellow. Other variations with CEE sockets 3, 4 or 5 pole and with grounding-type sockets
of French/Belgian, British, Swiss and US-standards on request. Dimensions page 111.

Fitted with
3 CEE 16 A, 5 p, 400 V

Fusing

Connection
2 m H07RN-F5G2.5 with
CEE-plug 16 A, 5 p, 400 V
Connection and load values

Protection type
IP44
Part no.
70029

Fitted with
1 CEE 32 A, 3 p, 230 V
4 CEE 16 A, 3 p, 230 V

Fusing
1 RCD/MCB 32 A, 1 p+N, C, 0.03 A
4 MCB´s 16 A, 1 p, C

Connection
1 Inlet 32 A, 3 p, 230 V

Connection and load values


Pre-fuse max. 32 A
InA 32 A
RDF 1
Protection type
IP44
Part no.
7420224

MENNEKES | 59
Combination units – Steel and stainless steel, product information

Stainless steel
surface mounted and
flush mounted combination
units.

Safe. Practical. Timelessly elegant.


• Protection type IP43 or IP44 with closed door, even when
plugs are inserted
• The cable guard aperture is sufficiently dimensioned for
leading through cables
• Safety lock protects against unauthorised access

CombiTOWER
Outdoors and indoors.
Short routes to your energy source for industry,
workshops, assembly shops, loading platforms, etc.

Power posts
Rugged. Vandalism-proof.
Steel power posts provide a safe means of energy supply, protection
against car-crossing. Hot-dip galvanised and powder coated.
Available in various sizes.

60 | MENNEKES www.MENNEKES.co.uk
Combination units – Stainless steel
CombiTOWER from stainless steel (material 1.4301), material 1.4571 on request.
For drawings and dimensions see page 111.

Title Title
CombiTOWER CombiTOWER
Fitted with Fitted with
with removable cover, with lockable door
painted signal yellow (RAL 1003) and removable cover,
or bright finish. painted signal yellow (RAL 1003)
or bright finish

Part no. Part no.


for AMAXX enclosures for AMAXX enclosures
260 x 225 mm, 260 x 225 mm,
390 x 225 mm and 390 x 225 mm and
520 x 225 mm 520 x 225 mm
4
* Part no. * Part no.
for AMAXX enclosures for AMAXX enclosures
650 x 225 mm 650 x 225 mm

Enclosure size Enclosure size


1043 x 254.5 x 250 mm (H x W x D) 1043 x 254 x 415 mm (H x W x D)
Part no. Part no.
15679 / * 15739 yellow 15681 / * 15741 yellow
15678 / * 15738 bright finish 15680 / * 15740 bright finish

MENNEKES | 61
Special plugs and sockets – Product information SCHUKO® and grounding-type

SCHUKO®
Plugs and sockets for harsh conditions.
SCHUKO® by MENNEKES with the
hammer symbol.
Acc. to VDE 0105 part 115. Made of
high-grade plastic. Acc. to VDE 0620
for harsh conditions. Application
amongst others in agriculture or at
construction sites. Resistant against
oil, grease and fuel. Long lasting due
to high resistance against abrasion
and breaking strenght. Durable due
to resistance against embrittlement.

Panel mounted sockets SCHUKO® with front gasket for portable units.

The attachment sockets SCHUKO® Product advantages:


with sealing collars, from MENNEKES • retention of the installation dimensions and
comply with the requirements in the conditions
new standard, IEC 620-1. • conversion without problems
• flange sealing made of thermoplastic
With the hinged lid closed, they satisfy elastomer (TPE)
the requirements for the IP54 degree • captive due to two components technology
of protection in every position. • safe against accidental actuation with a
finger or the back of the hand according to
Even with the compatible IP44 plug, IEC 60529
plugged-in, the IP44 protection rating • optionally screw or plug-in terminals
is ensured regardless of the operating • with hammer symbol for toughest
position conditions
• also available with flange dimensions
75 x 75 mm for cable ducts and flush
mounted boxes

SCHUKO®. Pressure watertight.


Whether fixed or mobile: in the event of flooding or water jets,
pressure watertight plugs and sockets are the first choice.
Protection type IP68.

62 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – SCHUKO® and grounding-type
SCHUKO® to DIN 49440-1, 2 p+E, 230 V. Other versions available on request. For drawings and dimensions see page 100 - 111.

Panel mounted socket SCHUKO® Colour Ampere Voltage with plug-in screw
with hinged lid, 3 plug-in terminals shutter terminals terminals
or 3 screw terminals as connecting grey 16 230 11010 11030
terminals for 1.5 - 2.5 mm2
blue 16 230 11011 11031
black 16 230 11012 11032
red 16 230 11013 11033
IP54 grey 16 230  11060
Std. Pack. Qty: 100/20
blue 16 230  11061 11081
Drawing: 1 MB 410

Panel mounted socket SCHUKO® Colour Ampere Voltage with plug-in screw
with front gasket shutter terminals terminals
with hinged lid, 3 plug-in terminals grey 16 230 11310 11330
or 3 screw terminals as connecting
terminals for 1.5 - 2.5 mm2 blue 16 230 11311 11331
black 16 230 11312 11332
red 16 230 11313 11333
IP54
Std. Pack. Qty: 100
Drawing: 1 MB 586

Panel mounted socket SCHUKO® Colour Ampere Voltage with plug-in screw
without hinged lid, 3 plug-in shutter terminals terminals
terminals or 3 screw terminals as blue 16 230 11511 11531
connecting terminals for
1.5 - 2.5 mm2 black 16 230 11512 11532
blue 16 230  11561 11581

IP20
Std. Pack. Qty: 100
Drawing: 1 MB 450

Wall mounted socket SCHUKO® Colour Ampere Voltage with plug-in screw
with hinged lid, 3 plug-in terminals shutter terminals terminals
as connecting terminals for 1.5 - 2.5 grey 16 230 10081
mm2, sockets can be linked in a row
vertically. Slide on top, slot on bottom blue 16 230 10082
of enclosure black 16 230 10083

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 27/30

Wall mounted socket Colour Ampere Voltage with plug-in screw


grounding-type shutter terminals terminals
French/Belgian system (NF) with blue 16 230  10092
hinged lid, 3 plug-in terminals as
connecting terminals for 1.5 - 2.5
mm2, sockets can be linked in a row 5
vertically. Slide on top, slot on bottom
of enclosure
IP44
Std. Pack. Qty: 10
Drawing: 1 MB 27/30

Panel mounted socket Colour Ampere Voltage with plug-in screw


grounding-type shutter terminals terminals
French/Belgian system (NF), with grey 16 230 11110
hinged lid, 3 plug-in terminals or
3 screw terminals as connecting blue 16 230 11111 11131
terminals for 1.5 - 2.5 mm2 grey 16 230  11160 11180
blue 16 230  11161 11181
IP44 black 16 230  11162 11182
Std. Pack. Qty: 10
Drawing: 1 MB 410

MENNEKES | 63
Special plugs and sockets – SCHUKO® and grounding-type
SCHUKO® to DIN 49440-1, 2 p+E, 230 V. Other versions available on request. For drawings and dimensions see page 100 - 111.

Panel mounted socket Colour Ampere Voltage with plug-in screw


grounding-type shutter terminals terminals
French/Belgian system (NF), without blue 16 230  11611
hinged lid, 3 plug-in terminals or
3 screw terminals as connecting blue 16 230 11661 11681
terminals for 1.5 - 2.5 mm2

IP20
Std. Pack. Qty: 100/20
Drawing: 1 MB 450

Panel mounted socket Colour Ampere Voltage with plug-in screw


grounding-type shutter terminals terminals
British standard, with hinged lid and blue 13 230  10718
seal; flange 50 x 50 mm, fixing holes
38 x 38 mm

IP44
Std. Pack. Qty: 20
Drawing: 1 MB 584

Panel mounted socket Colour Ampere Voltage with plug-in screw


grounding-type shutter terminals terminals
British standard, matching cover black 13 230  10713
frame, with hinged lid and seal

IP44
Std. Pack. Qty: 20
Drawing: 1 MB 422

Panel mounted socket NEMA Colour Ampere Voltage with plug-in screw
USA and Canada, with hinged lid shutter terminals terminals
blu 15 125 10087

IP44
Std. Pack. Qty: 20
Drawing: 1 MB 421

Plug SCHUKO® Colour Ampere Voltage Part no.


with combined PE-conductor acc.
to German and French/Belgian grey 16 230 10749
standards, with grommet, for cables
black 16 230 10754
up to 3 x 2.5 mm2 up to H07RN-F
5 orange 16 230 10837
blue 16 230 10838
red 16 230 10839
IP44 yellow 16 230 10840
Std. Pack. Qty: 20
green 16 230 10841

Connector SCHUKO® Colour Ampere Voltage Part no.


with grommet and lid for cables up
to 3 x 2.5 mm2 up to H07RN-F grey 16 230 10751
black 16 230 10755
orange 16 230 10842
blue 16 230 10843
red 16 230 10844
IP44 yellow 16 230 10845
Std. Pack. Qty: 10
green 16 230 10846

64 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – SCHUKO® and grounding-type
to DIN 49442/43 and DIN VDE 0620. Other versions available on request. For drawings and dimensions see page 100 - 111.

Wall mounted socket Colour Ampere Voltage with plug-in screw


SCHUKO® shutter terminals terminals
with hinged bayonet lock lid
blue / grey 16 230 10863

IP68
Std. Pack. Qty: 10
Drawing: 1 MB 347

Panel mounted socket Colour Ampere Voltage with plug-in screw


SCHUKO® or NF shutter terminals terminals
with hinged bayonet lock lid, blue / grey 16 230 17002 17006
rectangular flange, four fixing holes
or two stamped recesses for quick blue / grey 16 230  17014
perforation

IP68
Std. Pack. Qty: 10
Drawing: 1 MB 627

Plug SCHUKO® Colour Ampere Voltage plug-in screw


combined PE-conductor acc. terminals terminals
to German and French/Belgian blue / grey 16 230 10828
standards, with bayonet ring, with
protective cap attached by a strap,
for cables up to 3 x 2.5 mm2, up to
H07RN-F

IP68
Std. Pack. Qty: 10

Connector SCHUKO® Colour Ampere Voltage plug-in screw


with bayonet lock lid attached by a terminals terminals
strap, for cables up to 3 x 2.5 mm2, blue / grey 16 230 10833
up to H07RN-F

IP68
Std. Pack. Qty: 10

MENNEKES | 65
Special plugs and sockets – Product information 7 pole

7 pole
For multifunctional applications.

These 7 pole plugs and sockets provide solutions where there are multifunctional requirements in industry, farming and commerce.

This number of poles provides solutions in the following fields:


• 
Star-delta start-up
• Closed loop control
• Open loop control
• Monitoring
• Detection and alarms
• Clearing alarms
• 
Electrical interlocking

Position of ground contact tube with respect to polarisation keyway, designated by clockface position for 6 p + , 16 A and 32 A.

5
Frequency
Hz
Rated operating voltage
V
Position of ground
contact 6 p+
100 to 300 above 50 10
above 300 to 500 above 50 2
110 4
230 9
50
400 6
500 7
220 to 240
50 downstream from isolating 12
transformer
6 p+

66 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – 7 pole
to DIN VDE 0623-1, EN 60309-1. Colour: light grey and/or colour code. Highly resistant to chemicals. Other voltages and frequencies available
on request. For drawings and dimensions see page 100 - 111.

Wall mounted socket A P 230 V 400 V 500 V


with highly heat resistant contact 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz
carrier, nickel plated contacts, 16 7 733 734 1035
internal fixing, enclosure base can
be turned 180° 32 7 735 736 1040

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 43/257

Wall mounted socket A P 230 V 400 V 500 V


highly resistant to chemicals, highly 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz
heat resistant contact carrier, nickel 16 7 9530 9531 9532
plated contacts, 2 external fixings,
enclosure can be turned 180° 32 7 9590 9591 9592

IP67
Std. Pack. Qty: 10
Drawing: 1 MB 622

Wall mounted socket A P 230 V 400 V 500 V


switched, mechanical DUO-interlock, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz
highly heat resistant contact carrier, 16 7 7306
nickel plated contacts, 6 pole switch
with 2 auxiliary contacts (1 NO and 32 7 7307
1 NC), sockets can be padlocked

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 382

Panel mounted socket A P 230 V 400 V 500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz
nickel plated contacts, 16 7 737 738 1045
20° inclination
32 7 739 740 1050

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 260

Panel mounted socket A P 230 V 400 V 500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz
nickel plated contacts, 16 7 2883 2459 2296
20° inclination
32 7 3775 2317 2212
5

IP67
Std. Pack. Qty: 10
Drawing: 1 MB 251

Plug AM-TOP A P 230 V 400 V 500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz
nickel plated contacts, single part 16 7 741 742 1055
body, cable gland and sealing, strain
relief and protection against kinking 32 7 743 744 1060

IP44
Std. Pack. Qty: 10

MENNEKES | 67
Special plugs and sockets – 7 pole
to DIN VDE 0623-1, EN 60309-1. Colour: light grey and/or colour code. Other voltages and frequencies available on request. For drawings and
dimensions see page 100 - 111.

Plug AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nickel plated contacts, single part 16 7 3776 3777 3913
body, cable gland and sealing, strain
relief and protection against kinking 32 7 2405 2324 2213

IP67
Std. Pack. Qty: 10

Wall mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nickel plated contacts 16 7 2166
32 7 2167

IP44
Std. Pack. Qty: 10
Drawing: 2 MB 147

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nickel plated contacts 16 7 749 750 1075
32 7 751 752 1080

IP44
Std. Pack. Qty: 10
Drawing: 2 MB 71

Panel mounted inlet A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
carrier, nickel plated contacts, with 16 7 3914
protective cap
32 7 3915

IP67
Std. Pack. Qty: 10
Drawing: 2 MB 203

Connector AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


with highly heat resistant contact 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
carrier, nickel plated contacts, single 16 7 745 746 1065
part body, cable gland and sealing,
strain relief and protection against 32 7 747 748 1070
5 kinking

IP44
Std. Pack. Qty: 10

Connector AM-TOP A P 110 V 230 V 400 V 500 V >50 - ​500 V


highly heat resistant contact carrier, 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 50 a. 60 Hz 100-300 Hz 300-500 Hz
nickel plated contacts, single part 16 7 3783 3916 3784
body, cable gland and sealing, strain
relief and protection against kinking 32 7 2406 2255 2460

IP67
Std. Pack. Qty: 10

68 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – 600 V to 690 V
to DIN VDE 0623-1, EN 60309-1. Colour: grey

Plug PowerTOP Xtra R with A P 600 - 690 V


ErgoCONTACT 50 a. 60 Hz
screw terminals ErgoCONTACT, 16 5 13599
highly heat resistant contact carrier,
nickel plated contacts, ergonomic 32 5 13610
enclosure design with nubbed grip
areas, rubberised cable gland with
sealing, thread lock and safety slide
IP54
Std. Pack. Qty: 10

Connector PowerTOP Xtra R with A P 600 - 690 V


ErgoCONTACT 50 a. 60 Hz
screw terminals ErgoCONTACT, 16 5 14599
X-CONTACT, highly heat resistant
contact carrier, nickel plated
contacts, ergonomic enclosure
design with nubbed grip areas,
rubberised cable gland with sealing
IP54
Std. Pack. Qty: 10

Plug PowerTOP Xtra R A P 600 - 690 V


screw terminals, highly heat resistant 50 a. 60 Hz
contact carrier, nickel plated 63 4 13236
contacts, rubberised grip area, cable
gland and sealing, enclosure with 63 5 13237
thread lock and safety slide, strain 125 4 13238
relief and protection against kinking
125 5 13239
IP67
Std. Pack. Qty: 10

MENNEKES | 69
Special plugs and sockets – Special 1 h clock position
to DIN VDE 0623-1, EN 60309-1. Colour: grey

Plug PowerTOP Xtra R with A P 50 - 500 V


ErgoCONTACT
screw terminals ErgoCONTACT,
highly heat resistant contact carrier, 16 5 13597
nickel plated contacts, ergonomic
enclosure design with nubbed grip 32 5 13609
areas, rubberised cable gland with
sealing, thread lock and safety slide
IP54
Std. Pack. Qty: 10

Connector PowerTOP Xtra R with A P 50 - 500 V


ErgoCONTACT
screw terminals ErgoCONTACT,
X-CONTACT, highly heat resi- 16 5 14597
stant contact carrier, nickel plated
contacts, ergonomic enclosure 32 5 14609
design with nubbed grip areas,
rubberised cable gland with sealing
IP54
Std. Pack. Qty: 10

70 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – For low voltage
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Low voltages.
When portable electric appliances are used in
environments where conductive materials are present
and where movement is restricted, they must be
operated at low voltage or they must be electrically
isolated, e.g. in or on boilers, containers, pipework
systems, steel scaffolding or similar installations. The
same applies to rooms containing exposed conductive
materials. Portable lamps must be operated at low
voltage.

Stationary appliances may be operated at a safe low


voltage or they may be electrically isolated, e.g. lamps
installed temporarily for maintenance purposes, cleaning
or other types of work, which are connected to the
power supply by means of movable cables. Only use
tools of protection type II or III. Also, lamps for barrels
and movable lamps for ovens must be operated at low
voltage.

Furthermore, low voltage 25 V AC should be used for all


mobile appliances without insulation which are used on
animals, e.g. shears, milking machines, etc.

Requirements on plugs and sockets for low voltages.


Plugs and sockets must be different from those used at
other voltages and must not be provided with an earth
contact (VDE 0100 part 410:1997-01).

Wall mounted socket A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 1825 1831 1829


16 3 1832 1837 1835 5
32 2 1838 1844 1842
IP44 32 3 1845 1850 1848
Std. Pack. Qty: 10
Drawing: 1 MB 294

Wall mounted socket A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 577 578 583


16 3 584 585 586
32 2 590 591 596
IP44 32 3 597 598 599
Std. Pack. Qty: 10
Drawing: 1 MB 137

MENNEKES | 71
Special plugs and sockets – For low voltage
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Panel mounted socket A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


flange 55 x 55 mm, straight 40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 603 604 609


16 3 610 611 612
32 2 616 617 622
IP44 32 3 623 624 625
Std. Pack. Qty: 10
Drawing: 1 MB 136

Panel mounted socket A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


flange 75 x 75 mm, straight 40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 1602 1603 2617A


16 3 1657 1661 1823
32 2 1693 3290 2488A
IP44 32 3 1594 1579
Std. Pack. Qty: 10
Drawing: 1 MB 292

Panel mounted socket A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


flange 68 x 62 mm, 20° inclination 40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 1270 2855 2841


16 3 2845 1272 2860
32 2 1271 2864 2869
IP44 32 3 2870 1273 2852
Std. Pack. Qty: 10
Drawing: 1 MB 231

Panel mounted socket A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


20° inclination 40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

32 3 2837

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 236

72 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – For low voltage
to DIN VDE 0623, EN 60309-2. Other voltages and frequencies available on request. For drawings and dimensions see page 100 - 111.

Plug A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V
with cable gland 40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 655A 656A 661A


16 3 662A 663A 664A
32 2 668A 669A 674A

IP44 32 3 675A 676A 677A


Std. Pack. Qty: 10

Wall mounted inlet A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V


40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 1955 1961 1959


16 3 1962 1967 1965
32 2 1968 1974 1972

IP44 32 3 1975 1980 1978


Std. Pack. Qty: 10
Drawing: 2 MB 160

Connector A P 20 - 25 V 40 - 50 V 20 - 25 V 20 - 25 V
with cable gland 40 - 50 V 40 - 50 V
50 a. 60 Hz 50 a. 60 Hz 100-200 Hz

16 2 707A 708A 713A


16 3 714A 715A 716A
32 2 720A 721A 726A

IP44 32 3 727A 728A 729A


Std. Pack. Qty: 10

MENNEKES | 73
Special plugs and sockets – Isolating transformer 12 h
Color: grey. Other voltages and frequencies on request.

Plug PowerTOP Xtra R with A P Isolating transformer


ErgoCONTACT
screw terminals ErgoCONTACT,
highly heat resistant contact carrier, 16 5 13601
nickel plated contacts, ergonomic
enclosure design with nubbed grip 32 5 13613
areas, rubberised cable gland with
sealing, thread lock and safety slide
IP54
Std. Pack. Qty: 10

Connector PowerTOP Xtra R with A P Isolating transformer


ErgoCONTACT
screw terminals ErgoCONTACT,
X-CONTACT, highly heat 16 5 14601
resistant contact carrier, nickel
plated contacts, ergonomic
enclosure design with nubbed grip
areas, thread lock and safety slide
IP54
Std. Pack. Qty: 10

74 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – Product information 160 A up to 600 A

160 A - 600 A
Heavy duty versions
for industry.
The heavy duty range supplements the plugs and sockets currently
covered by EN 60309-2, making available rated currents of
160 A - 600 A and rated voltages of up to 1000 V. Their design is
based on the following standard: EN 60309-1.

•S
 hock hazard protected using contact covers on sockets and
connectors
• Surface protection against corrosive environment for contacts
•M echanical lock and electrical lock with fuse protection for specific
heavy duty sockets

Visit our website to explore our entire range of heavy duty products
for 160 A - 600 A.

You can find our heavy duty versions on our website:


www.MENNEKES.co.uk/heavydutyversions

MENNEKES | 75
Special plugs and sockets – Energy and data
Protection type IP44.
The right choice for control stations, storage areas, laboratories, airports, production lines, etc. Cepex data port sockets are operated with standard
patch cables and can be combined with Cepex sockets CEE and/or SCHUKO®. For wall-/panel mounting or installation in cable ducts.

Cepex data port sockets.


4

5
2

3
Title
1 Network enclosure AMAXX
Fitted with
2 Cepex enclosures
(part no.: 4345G)
prepared for 4 RJ45 connection
modules, type E-DAT module or
OpDAT module LC or ST (brand

1 The bottom part of the


enclosure can be turned
4 Lockable even
with connected
BTR - Not in scope of supply)

by 180 degrees, which cables. The safety Cable entry:


allows cable insertion from lock prevents 2 x M 25 at the top (closed),
above or below without unauthorized access. 2 x M 25 at the bottom (closed)
additional work. and
2 x M 20 top and bottom (closed)

2 Protection
 type IP44 with
5 Visible labeling field.

closed cover or with plug


inserted.

3 Suitable for double RJ45


ports, Cat. 3 to Cat. 7 and
manufacturerindependent
5 RJ45 Keystones. Openings
according to IEC 60603-7.

Network enclosure AMAXX


also available with
1 Cepex enclosure
(part no.: 25104, 25104GE)

Simple: Extra:
A metric cable gland M 25 / 2 x 8 Enclosure size
All types are equipped with a
membrane gland fitting M 25 for is optionally available. 130 x 225 mm (H x W)
two cables 3-9 mm. Part no.
Simply push in the cable – done!
25102GE yellow
25102 light grey

76 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – Energy and data
Colours: light grey (RAL 7035), pure white (RAL 9010), grey (RAL 9006), deep black (RAL 9005). For drawings and dimensions see page 100 - 111.

Cepex enclosure, light grey


Brand Type Data module Part no.
as wall mounted socket, for
installation of RJ45 data port AMP Twist — 4350 1)
sockets, 2 keys, identical lock: AMP Jack 2 x 41457 4360
Part no. + Index “G“ AMP CO Plus — 4370 *
BTR E-DAT module 2 x 41455 4340 3)
Rutenbeck iso-8/8 Up0S 1 x 41492 4320
IP44 TKM KDMF 1 x 41452 4300 1)
Std. Pack. Qty: 5
Reichle & De-Massari Module Real 10 2 x 25056 4375 2)
Drawing: 1 MB 313

Cepex enclosure, light grey


Brand Type Data module Part no.
as panel mounted socket, for
installation of RJ45 data port AMP Twist — 4352 1)
sockets, 2 keys, identical lock: AMP Jack 2 x 41457 4362
Part no. + Index “G“ AMP CO Plus — 4372 *
BTR E-DAT module 2 x 41455 4342 3)
Rutenbeck iso-8/8 Up0S 1 x 41492 4322
IP44 TKM KDMF 1 x 41452 4302 1)
Std. Pack. Qty: 5
Reichle & De-Massari Module Real 10 2 x 25056 4377 2)
Drawing: 1 MB 305

Cepex enclosure, pure white


Brand Type Data module Part no.
as panel mounted socket, for
installation of RJ45 data port AMP Twist — 4354 1)
sockets, 2 keys, identical lock: AMP Jack 2 x 41457 4364
Part no. + Index “G“ AMP CO Plus — 4374 *
BTR E-DAT module 2 x 41455 4344 3)
Rutenbeck iso-8/8 Up0S 1 x 41492 4324
IP44 TKM KDMF 1 x 41452 4304 1)
Std. Pack. Qty: 5
Drawing: 1 MB 305

Cepex enclosure, grey


Brand Type Data module Part no.
as panel mounted socket, for
installation of RJ45 data port Rutenbeck iso-8/8 Up0S 4326
sockets, 2 keys, identical lock:
Part no. + Index “G“

IP44
Std. Pack. Qty: 5
Drawing: 1 MB 305

Cepex enclosure, deep black


Brand Type Data module Part no.
as panel mounted socket, for
installation of RJ45 data port BTR Module E-DAT 2 x 41455 4345 3)
sockets, 2 keys, identical lock: Rutenbeck iso-8/8 Up0S 1 x 41492 4367
Part no. + Index “G“ Reichle & De-Massari Module Real 10 2 x 25056 4378 2)
5

IP44
Std. Pack. Qty: 5
Drawing: 1 MB 305

1)
Cepex enclosures also suited for data modules of Telegärtner (AMJ 45 Up/O, cat.6a) and Nexans (LANmark-6 Snap-in Connector with fixing
ring Modular Outlet 50).

2)
Cepex enclosures also suited for the connection modules Telegärtner (AMJ/UMJ cat.6+, Setec (XKJ), Corning (FutureCOM S10TENe Keystone),
Dätwyler (KS-T6A, MS-K, PS-GG45), Rutenbeck (UM real cat.6a, A), LEONI MegaLine, Keystone.

3)
Cepex enclosures also suited for LEONI MegaLine.

* The data inserts/modules AMP CO Plus are not part of the MENNEKES delivery program!

MENNEKES | 77
Special plugs and sockets – Energy and data

Overview of mounting options for RJ45 modules in empty Cepex enclosures.

RJ45 modules and Cepex panel mounted socket Cepex surface-


Keystones mounted socket
Brand Type Part no. Part no. Part no. Part no. Part no. Part no.
data enclosure enclosure enclo- enclosure enclosure
module Light grey (RAL 7035) Pure white sure Grey Light grey (RAL 7035)
(RAL 9010) Deep (RAL
black 9006)
(RAL
9005)

4377*

4378*

4375*
4302
4322
4342
4352
4362
4372

4304
4324
4344
4354
4364
4374
4345
4367

4326

4300
4320
4340
4350
4360
4370
AMP Jack 41557
• • •
AMP CO Plus
• • •
Telegärtner AMJ 45 Up/O
• • • • •
Telegärtner AMJ/UMJ module
• • •
Nexans LANmark
connector • • • • • •
BTR E-DAT module 41455
• • • •
Rutenbeck iso-8/8 UP0S 41492
• • • • •
Rutenbeck UM real
• • •
TKM KDMF 41452
• • •
Reichle & De-
Massari
Module
Real 10
25056
• • •
Setec XKJ
• • •
Corning FutureCom
• • •
Dätwyler KS-T6A
• • •
LEONI MegaLine
• • • • • • •
* Keystones

Our keystone-variations can be fitted with supplier independent modules. Beside RJ45 modules a large variety of electrical and optical
connections for data transmission can be fitted.

78 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – Energy and data

Data module Part no.


BTR, type: RJ45 connection module
270° (type E-DAT module 41455
8(8) jack cat.6), suitable for Cepex
data port sockets, part no. 4340,
4342, 4344, 4355, strain relief per
locking clip directly on the stuffer
cap

Std. Pack. Qty: 20

Data module Part no.


AMP, type: RJ45 connection module
(type Cat.6 SL Jack), suitable for 41457
Cepex data port sockets, part no.
4360 and versions

Std. Pack. Qty: 12

Data module Part no.


Reichle & De-Massari, type: data
port sockets insert Real 10, Cat.6, 25056
screened, including frame for snap-
in, suitable for Cepex data port
sockets, Part no. 4375 and versions

Std. Pack. Qty: 10

Data module Part no.


Rutenbeck, type: data port insert
2 x RJ45, Cat.6a, (type UP0S), 41492
suitable for Cepex data port
sockets, Part no. 4320 and versions

Std. Pack. Qty: 10

Data module Part no.


TKM, type: data port insert 2 x RJ45,
Cat.6, (type KDMF), suitable for 41452
Cepex data port sockets,
Part no. 4300 and versions
5

Std. Pack. Qty: 10

Data module Part no.


RJ45 connection module, type
E-DAT module, connector 8(8) 25042
90º, Cat.6 (recommended for
improved cable routing), for Cepex
data port sockets

Std. Pack. Qty: 10

MENNEKES | 79
Special plugs and sockets – Energy and data
Protection type IP44.
Pre-wired for installation, enclosure front cover light grey RAL 7035, yellow (GE) RAL 1021 also available on request. Enclosure hinged to the side.

MENNEKES network distributor.

AMAXX
cable gland set

enclosed with each media


distributor
Deep black RAL 9005,
2 screw fittings M 40
2 multiple seals with
6 openings for a cable diameter
of 6-9 mm
including each 5 blind plugs
1 screw fitting M 20

Fitted with
Patch and mounting panel with
threaded ground bolt M 6 for
the optional connection of an
external ground conductor
With the new industrial network distributor from the AMAXX family,
MENNEKES offers a product for the expansion of network solutions. 2 SCHUKO® sockets for the
power supply of active network
components
By using a robust plastic enclosure, the installation of standard
network components is possible in more demanding environments, 1 Cepex data port socket (deep
such as those that prevail in trade and industry, with regard to black RAL 9005) with 2 RJ45
protection class, mechanical influences or similar factors. right angle connector modules
for direct connection of patch
Existing networks can thus be quickly expanded, while smaller cables
networks can easily be rebuilt. The user can act freely in the
4 Velcro connectors for fastening Velcro connector
selection of active network components and Keystones. Hence the
installed components on the
5 preferred switches or routers can be easily and safely attached to the
base plate enclosed with each media
integrated mounting plate. The patch panel for mounting up to eight distributor
Keystones can be equipped with RJ45 sockets or other inserts. 2 screw fittings M 40 with Set of 4 Velcro connectors for
multiple seal, 6 openings for fastening installed components
Two SCHUKO® sockets integrated into the enclosure are used a cable diameter of 6-9 mm on the base plate
for the power supply of the active network components. Another including 5 each blanking plugs
advantage for the user: After the power supply has been connected
by the qualified electrician, the further equipping and manipulation of 1 screw fitting M 20
the enclosure can be performed by laymen in the field of electrical
1 screw set
technology.

Enclosure size
520 x 225 mm (H x W)
Part no.
25405

80 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – Product information for reefer containers

Plugs and sockets for reefer containers


On ships and in terminals.

AM-TOP plugs and connectors.


Stable enclosure consisting of one part. The teeth on the cable gland secure a safe grip and protect against loosening. The cable gland serves
as an anti-bend protection for the cables at the same time.

Wall mounted sockets, switched and interlocked. Combination units with sockets,
Sockets with the patented, mechanical DUO-interlocking ensure that switched and interlocked. 5
the socket can only be switched when inserting a plug.

380 -
32 A
440 V 3h
3 p+
MENNEKES | 81
Special plugs and sockets – For reefer containers
Ground contact at 3 o‘clock position conforming to DIN VDE 0623, EN 60309-2. Highly resistant to chemicals.
Other versions available on request. For drawings and dimensions see page 100 - 111.

Wall mounted socket A P 380 - 440 V


highly resistant to chemicals, with 50 a. 60 Hz
highly heat resistant contact carrier 32 4 9562
and nickel plated contacts

IP67
Std. Pack. Qty: 10
Drawing: 1 MB 622

NEW Wall mounted socket R A P 380 - 440 V


with highly heat resistant contact 50 a. 60 Hz
carrier and nickel plated contacts, 32 4 5704403G
switched, with mechanical
DUO-interlock

IP67
Std. Pack. Qty: 1
Drawing: 1 MB 714

Wall mounted socket A P 380 - 440 V


with highly heat resistant contact 50 a. 60 Hz
carrier and nickel plated contacts, 32 4 5946AN
switched, with mechanical
DUO-interlock and DIN rail,
protected by 1 RCD 30 mA

IP67
Std. Pack. Qty: 2
Drawing: 1 MB 181/620

Panel mounted socket A P 380 - 440 V


with highly heat resistant contact 50 a. 60 Hz
carrier and nickel plated contacts, 32 4 2123A
flange 85 x 75 mm, straight

IP67
Std. Pack. Qty: 10
Drawing: 1 MB 141

Plug AM-TOP A P 380 - 440 V


with highly heat resistant contact 50 a. 60 Hz
carrier and nickel plated contacts, 32 4 2175B
with screw terminals and single part
body
5

IP67
Std. Pack. Qty: 10

Phase sequence test plug A P 380 - 440 V


earthing contact in the 3 o‘clock 50 a. 60 Hz
position, conforming to VDE 0413 32 4 3718
part 7

IP44
Std. Pack. Qty: 5

82 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – For reefer containers
Ground contact at 3 o‘clock position conforming to DIN VDE 0623, EN 60309-2.
Other versions available on request. For drawings and dimensions see page 100 - 111.

Panel mounted inlet A P 380 - 440 V


with highly heat resistant contact 50 a. 60 Hz
carrier and nickel plated contacts, 32 4 2692
with hinged lid

IP67
Std. Pack. Qty: 10
Drawing: 2 MB 40

Connector AM-TOP A P 380 - 440 V


with highly heat resistant contact 50 a. 60 Hz
carrier and nickel plated contacts, 32 4 2177A
with screw terminals and single part
body

IP67
Std. Pack. Qty: 10

Protective cap
Part no.
for plugs 32 A, 4 p
40841

Std. Pack. Qty: 10

Houlder
Part no.
for plugs 32 A, 4 p
41342

Std. Pack. Qty: 10

MENNEKES | 83
Special plugs and sockets – For reefer containers
Protection type IP67.
Ground contact at 3 o‘clock position conforming to DIN VDE 0623, EN 60309-2. Other versions available on request. Sockets switched, with
mechanical DUO-interlock with highly heat resistant contact carrier and nickel plated contacts. For drawings and dimensions see page 109 - 110..
It is self - evident for us to offer customized solutions which are especially made for your demand. Please contact us!

AIDAbella, Jos. L. Meyer-Werft, Papenburg, Germany

CEE sockets
3 CEE 32 A, 4 p, 380-440 V, 3 h
For reefer containers, switched,
with mechanical DUO-interlock

CEE sockets

Sockets British standard

Fusing
3 MCB‘s 32 A, 3 p, C
1 earth bolt M 10, V2A

5 Connection
For 1 cable up to 5 x 25 mm²

Connection and load values


Pre-fuse max. 100 A
InA 58 A
RDF 0.6
Jos. L. Meyer-Werft, Papenburg, Germany
Enclosure size
520 x 225 mm (H x W)
Part no.
940027

84 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – TM for military purpose
to DIN EN 60309-2, colour: bronze-green RAL 6031-F9. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111.

Defence Equipment Standard 96919 and 96926.

MENNEKES TM plugs and sockets, colour bronze-green RAL 60301, have been designed to stand up to especially tough conditions.
TM plugs and sockets in accordance with VG 96919 or VG 96926 are suitable for use at ambient temperatures from -35 °C to +60 °C.
At ambient temperatures over +40 °C the rated current must be reduced.

Panel mounted socket TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


highly heat resistant contact carrier, nickel 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
plated contacts, straight, (form AS) 16 3 22928
63 A: X-CONTACT AS013
16 5 20458 23163 23175
AS001 AS003 AS004
32 3 23293A
AS042
32 5 20459 23176
IP67 AS005 AS008
Std. Pack. Qty: 10/5 63 5 20460 23165 23177
Drawing: 1 MB 217/1 AS009 AS011 AS012

Panel mounted socket TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


X-CONTACT, highly heat resistant contact 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
carrier, nickel plated contacts, straight, 125 5 23432
(form AS) AS014

IP67
Std. Pack. Qty: 5
Drawing: 1 MB 212/258

Panel mounted socket TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


highly heat resistant contact carrier, nickel 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
plated contacts, 20° inclination, (form BS) 16 3 24630
63 A: X-CONTACT BS017
16 5 24640 24643

32 3 24730
BS001 BS004
5
BS042
32 5 24740
IP67 BS005
Std. Pack. Qty: 10/5 63 5 24840
Drawing: 1 MB 474 BS009

Panel mounted socket TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


X-CONTACT, highly heat resistant contact 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
carrier, nickel plated contacts, 15° 125 5 22189A
inclination, (form BS) BS013

IP67
Std. Pack. Qty: 5
Drawing: 1 MB 339

MENNEKES | 85
Special plugs and sockets – TM for military purpose
to DIN EN 60309-2, colour: bronze-green RAL 6031-F9. Other voltages and frequencies available on request.
For drawings and dimensions see page 100 - 111.

Plug AM-TOP TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


highly heat resistant contact carrier, nickel 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
plated contacts, with protective cap, 16 3 24660
(form CP) CP017
16 5 24671 24670 24672
CP002 CP001 CP003
32 3 24760
CP042
32 5 24770 24772 24773
IP67 CP005 CP007 CP008
Std. Pack. Qty: 10

Plug PowerTOP Xtra TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


rubberised grip area, frame terminals, 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
highly heat resistant contact carrier, nickel 63 5 24870 24873
plated contacts, cable gland and sealing, CP009 CP012
strain relief and protection against kinking, 125 5 24970 24973
enclosure with thread lock, two safety CP013 CP016
slides, with protective cap, (form CP)

IP67
Std. Pack. Qty: 5

Panel mounted inlet TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


highly heat resistant contact carrier, nickel 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
plated contacts, with protective cap, 16 3 24210
(form BP) BP013
16 5 20461
BP001
32 3 23249
BP042
32 5 20462
IP67 BP005
Std. Pack. Qty: 10/5 63 5 20463
Drawing: 2 MB 62/1 BP009

Panel mounted inlet TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


highly heat resistant contact carrier, nickel 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
plated contacts, with protective cap,
(form AP) 125 5 23433

IP67
Std. Pack. Qty: 5
Drawing: 2 MB 206

Connector AM-TOP TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


highly heat resistant contact carrier, nickel 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
plated contacts, with protective cap, 16 3 24675
(form DS) DS017
16 5 24686 24685 24687
5 32 3
DS002
24775
DS001 DS003

DS042
32 5 24785 24787 24788
IP67 DS005 DS007 DS008
Std. Pack. Qty: 10

Connector PowerTOP Xtra TM A P 230 V 400 V 440 V- 460 V >50 - ​500 V


X-CONTACT, 50 a. 60 Hz 50 a. 60 Hz 60 Hz >300-500 Hz
rubberised grip area, frame terminals, 63 5 24885 24888
highly heat resistant contact carrier, nickel DS009 DS012
plated contacts, cable gland and sealing, 125 5 24985 24988
strain relief and protection against kinking, DS013 DS016
enclosure with thread lock, two safety
slides, with protective cap, (form DS)
IP67
Std. Pack. Qty: 5

86 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – Camping
For drawings and dimensions see page 100 - 111.

Wall mounted socket with


Description Part no.
TwinCONTACT
screwless spring terminal, external 16 A, 3 p, 230 V 1341
fixing

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 463

Panel mounted socket


Description Part no.
with eyelet, 20° inclination,
flange: 68 x 62 mm, 16 A, 3 p, 230 V 851
fixing hole spacing: 47 x 47 mm Plug with eyelet 16 A, 3 p, 230 V, 852
for panel mounted socket 851

IP44
Std. Pack. Qty: 10
Drawing: 1 MB 456

Plug ProTOP
Description Part no.
cable gland and sealing, strain relief
and protection against kinking, 16 A, 3 p, 230 V 13502
enclosure with thread lock and
safety slide

IP44
Std. Pack. Qty: 10

Built-in Plug
Description Part no.
nickel plated contacts
16 A, 3 p, 230 V, Lid: electric grey 8001
16 A, 3 p, 230 V, Lid: black 8008
Counter frame for built-in plugs 40744
CaraCONTACT 8001 and 8008

IP44
Std. Pack. Qty: 10
Drawing: 2 MB 70

Connector ProTOP
Description Part no.
cable gland and sealing, strain relief
and protection against kinking, 16 A, 3 p, 230 V 14502
enclosure with thread lock and
safety slide
5

IP44
Std. Pack. Qty: 10

Angled connector
Description Part no.
with grommet
16 A, 3 p, 230 V 1438

IP44
Std. Pack. Qty: 10

MENNEKES | 87
Special plugs and sockets – Switch disconnectors made of AMELAN
Disconnecting property in acc. with EN 60947 (up to 690 V). Finger protection in acc. with DIN 57106 / VDE 0106 T.100. Products with additional
aux.contact (1 x NO and 1 x NC). For drawings and dimensions see page 100 - 111.

Switch disconnector Rated Current Poles Auxiliary BS Motor rating Part no.
rigid enclosures, ample space Ampere contact AC3/440 V kilowatt
for wiring, padlocking facilities, 25 3 7,5 52241
excellent switching capacity, open
terminals and captive terminal 25 3  7,5 52242
screws 40 3 18,5 52243
40 3  18,5 52244
IP67 80 3 30.0 52245
Std. Pack. Qty: 1
80 3  30.0 52246
Drawing: 1 MB 412/3

Characteristics switch disconnector

without aux. with aux. without aux. with aux. without aux. with aux.
contact contact contact contact contact contact
Part numbers 52241 52242 52243 52244 52245 52246
Rated operational voltage Ue
IEC / EN / VDE / SEV 690 V 690 V 690 V
Main switch: Isol. voltage up to 690 V 690 V 690 V
Rated continuous current lu
IEC / EN / VDE 25 A 40 A 80 A
Rated operational current le
IEC / EN 25 A 40 A 80 A
Rated operational current at 50 up to 60 Hz
AC-23A IEC / EN / VDE
3 phase 220-240 V 5.5 kW 11.0 kW 18.5 kW
3 pole 380-440 V 11.0 kW 22.0 kW 18.5 kW
600-690 V 11.0 kW 18.5 kW 30.0 kW
AC-3 IEC / EN / VDE
3 phase 220-240 V 4.0 kW 7.5 kW 15.0 kW
3 pole 380-440 V 7.5 kW 18.5 kW 30.0 kW
600-690 V 7.5 kW 15.0 kW 30.0 kW
Rated breaking capacity
AC-23 A / AC-3 motor switch 220-240 V 220 A 350 A 550 A
380-440 V 220 A 350 A 550 A
600-690 V 135 A 190 A 285 A
Maximum fuse size (gL) 35 A 63 A 80 A
Terminal cross section
Single / multiple wire min. 1.0 mm2 4.0 mm2 6.0 mm2
max. 6.0 mm 2
16.0 mm 2
35.0 mm2

5 Fine-strand wire with sleeve min. 0.75 mm2 2.5 mm2 6.0 mm2
max. 4.0 mm2 10.0 mm2 25.0 mm2

Characteristics auxiliary contacts

Part numbers 52242 52244 52246


Auxiliary module 500 V 690 V 690 V
Rated operational voltage Ue
Rated continuous current lu 16 A 16 A 16 A
Rated operational current le 220-240 V
AC-15A IEC / EN 380-440 V 2.5 A / 1.5 A 6A/3A 6A/4A
Terminal cross section

Single / multiple wire min. 1.0 mm2 1.0 mm2 1.0 mm2
Fine-strand wire with sleeve max. 1.5 mm 2
2.5 mm 2
2.5 mm2

88 | MENNEKES www.MENNEKES.co.uk
Special plugs and sockets – Hinged windows

Hinged window Description Part no.


without protective cover,
with knurled screws,
frame colour electric grey, 2 modules 40444
window smoked glass
5 modules 40871
40871
without springs to close window automatically

IP44
Std. Pack. Qty: 100

Hinged window Description Part no.


without protective cover,
with knurled screws,
frame colour electric grey, 5 modules
40243
window smoked glass without springs to close window automatically

IP44
Std. Pack. Qty: 50

Hinged window Description Part no.


without protective cover,
with knurled screws,
frame colour electric grey, 6 modules 40985
window smoked glass

8 modules 40978

IP67
12 modules 40980
Std. Pack. Qty: 50

Hinged window Description Part no.


without protective cover,
with knurled screws,
frame colour black, 6 modules 40985ZB
window smoked glass

8 modules 40978ZA

IP67
12 modules 40980ZC
Std. Pack. Qty: 50

Hinged window Description Part no.


without protective cover,
with knurled screws,
frame colour electric grey, 6 modules 40986
window smoked glass
5
8 modules 40979

IP67
12 modules 40981
Std. Pack. Qty: 50

Installation kit Description Part no.


for hinged window with protective
cover, for fitting modules in doors
and enclosure covers for 6 modules
41431
for hinged window 40986

for 8 modules
41432
for hinged window 40979

for 12 modules
41433
Std. Pack. Qty: 10 for hinged window 40981

MENNEKES | 89
Service – References

BMW motorcycle plant, Berlin – Germany AIDAbella, Jos. L. Meyer Werft, Papenburg – Germany

Formula 1 circuit, Manama – Bahrain Constitution, Heerema Marine Contractors – Netherland

Port of Salalah – Oman Container Terminal, Le Havre – France

90 | MENNEKES www.MENNEKES.co.uk
Service – References

Container Terminal, Altenwerder – Germany Yas Marina Circuit, (Formula 1 Race Course), Abu Dhabi – UAE

Shanghai International Circuit, (Formula 1 Race Course), Brunnenmarkt, (Market Square), Vienna – Austria
Shanghai – China

KORDSA GLOBAL A.S., Industrial Yarn and Cord Factory, Izmit – Turkey Bauernmarkt, (Market Square), Hannover – Germany

MENNEKES | 91
Service – Regulations and standards
While correct to the best of our knowledge, the information we provide with respect to laws and regulations is in no way binding. Such information is
provided purely by way of assistance and makes no claim to completeness. The nature and composition of our appliances are exclusively as quoted
in the product description to which the part numbers refer directly.

Installation guidelines
It is best to proceed carefully with the installation and the use of electrical devices. The valid directives and standards, as well as the legal accident
prevention regulations must be complied with. The installer is responsible for compliance with the respective regulations.

MENNEKES CEE plugs and sockets conform to the following standards and regulations:
IEC 60309-1
IEC 60309-2
EN 60309-1
EN 60309-2
IEC 60309-1/VDE 0623 part 1
IEC 60309-2/VDE 0623 part 2

Applications
CEE plugs and sockets can and, under certain circumstances, must be used in industry, in commerce, in agriculture, in parks, in damp and wet
environments, outdoors, on building sites, in caravans, on boats and yachts, on camp sites, for dockside power supply installations (marinas), on
works premises where there is a fire hazard, at markets and fairground booths and for trailers and mobile homes.

Using CEE plugs and sockets will usually enable the planners and builders of electrical installations to comply with the „regulations for the
construction of low voltage systems as per DIN VDE 0100“.

Enclosure material

Plastic material
MENNEKES generally uses high-grade plastic material with the following excellent properties: Excellent electrical insulation, break-proof,
wearresistant, abrasion-resistant, dimensionally stable, self-extinguishing, heat-resistant, cold-resistant, stabilised against aging, resistant to seawater,
oil, and petrol. For use in industrial premises or place of work where the use of chemicals or other aggressive substances makes it necessary to use
other plastic materials, MENNEKES offers products with increased stability against fuel, oil and grease, diluted acids and alkali, cleaner and the most
aqueous salt solutions. These products are marked in the catalogue with . Products made of this plastic combine high mechanical, thermal and
electrical properties with excellent dimensional stability and resistance to chemicals and are fit for action in chemical plants, in refineries, in the food
processing industry, in washdown areas and so on.

Solid rubber
Solid rubber blends are preferably used wherever products are exposed to high mechanical and/or chemical loads. Solid rubber excels by its
outstanding dimensional stability; it is largely resistant to acid and lye and has a high resistance to breakdown and leakage current. Products made
from solid rubber blends, e.g. MENNEKES EverGUM, are resistant to weather and ageing. Under UV radiation, colour pigments may fade with time.
This is inevitable even to the latest state of the art yet it does not compromise the function in any way.

Stainless steel
Our high-quality stainless steel products are ideally suited for continuous use in buildings and outdoors. There is a potential risk of corrosion in open
air and indoor swimming pools, in coastal regions, offshore and in industrial areas with high air pollution. Subject to location and climatic conditions
discoloration and corrosion can arise. Through specific cleaning and maintenance procedures, impairments of the surface can be reduced or
avoided. In particularly aggressive ambient conditions we recommend the use of special stainless steels or coating the surfaces to further increase
corrosion resistance.

Contact material, small parts


Female and male contacts are made of brass; screws, springs, etc. are made of rust-proof material or surface-coated steel.

Characteristics of CEE plugs and sockets


MENNEKES CEE plugs and sockets are distinguished by the following features, which keep maintenance costs to a minimum:

• Easy to install
• Wiring space easily accessible
• Power screwdrivers can be used for installation
• Mostly fitted with Pozidriv screws (size 2)
• High contact pressure
• Low effort required for insertion and withdrawal
• Low transition resistance
• Easy-to-grip plugs

Application
CEE plugs and sockets with operating voltages up to 1000 V DC or AC, frequencies up to 500 Hz and rated currents up to 800 A, including plugs
and sockets for low voltage systems have become the standard all over the world. Basically suitable for indoor and outdoor applications in industry,
they are also used on building sites, farms, commercial premises, for caravans, mobile homes, boats, yachts and in households. CEE plugs and
sockets are polarised and non-reversible.

Ambient temperature

6 CEE plugs and sockets are suitable for ambient temperatures between -25 °C up to +40 °C.

Low voltage directive 2014/35/EU


CEE plugs and sockets are subject to the EC low voltage directive and must therefore be provided with the CE mark to ensure free traffic of goods
within the EU. A manufacturer‘s declaration is available on request.

92 | MENNEKES www.MENNEKES.co.uk
Service – Regulations and standards
Declaration of Conformity
Current plugs and sockets have been tested by the VDE Test and Certification Institute in Offenbach, Germany. Furthermore, various other certificates
from international inspection authorities have been obtained. A copy of test certificates is available on request.
The CE mark is not a compliance mark. MENNEKES CEE plugs and sockets satisfy the requirements specified in the low voltage directive and the
device and/or the packaging bears the „CE“ mark „ “ .

Cable glands

Metric Typical sealing area Typical capacity of terminal


M 12 2.5 - 6.5 mm 3.0 - 6.5 mm
M 16 2.5 - 8.0 mm 3.5 - 8.0 mm
M 20 5.0 - 12.0 mm 6.0 - 12.0 mm
M 25 9.0 - 18.0 mm 12.0 - 18.0 mm
M 32 14.0 - 25.0 mm 17.0 - 25.0 mm
M 40 18.0 - 32.0 mm 20.0 - 32.0 mm
M 50 24.0 - 38.0 mm 26.0 - 38.0 mm
M 63 30.0 - 44.0 mm 30.0 - 44.0 mm

Standard for low voltage switchgear and control gear assemblies - IEC 61439
The standard, IEC 61439, replaces IEC 60439 and describes the design and the test specifications for low voltage switchgear and control
gear assemblies. The new standard has influence on the distribution of electrical energy in industry, the domestic electrical installation and on
construction sites.

In 2012, the restructuring and revision of the safety requirements for low voltage switchgear was finalized with publication of the standard,
IEC 61439-1:2012. The preceding standard, IEC 60439-1 will be replaced by IEC 61439-1:2012. The former Standard IEC 60439 was replaced
by IEC 61439-1:2012 in September 2014. For all switchgear assemblies comissioned after this date, planning and documentation must be in
accordance with IEC 61439-1: 2012 and its parts.

The purpose of this standard is the harmonisation of most of the general regulations and requirements for low voltage switchgear and control gear
assemblies to achieve uniform requirements and verifications for switchgear and control assemblies and to avoid the necessity of verifications in
accordance with other standards. All requirements of the different switchgear and control gear assemblies have been combined in this fundamental
standard, together with topics of broad interest and application, e.g heating, insulation properties, etc.

In the future two main standards will be required for each design of a low voltage switchgear and control gear assembly:
• The basic standard that is referenced as „Part 1“ in the specific standards;
• The applicable parts 2 to 7 of the switchgear and control gear assembly standard that deals with the particularities of the application.

The IEC 61439 consists of the following parts:

IEC ...
61439-1: General definitions
61439-2: Power switchgear and control gear assemblies (PSC switchgear combinations)
61439-3: Installation distributor for operation by laymen (DBO)
61439-4: Special requirements for construction power distributors (BV)
61439-5: Switchgear combinations in public power distribution networks
61439-6: Busbar trunking systems (busways)
61439-7: Switchgear combinations for specific applications such as marinas, campsites, marketplaces, charging
stations for electric vehicles
IEC TR 61439-0: Guide for the specification of switchgear and controlgear assemblies

Requirements in this standard, which are object of an agreement between manufacturer of the switchgear and control gear assemblies and user, are
summarized on page 97 - 99. This listing facilitates provision of information concerning basic conditions and supplemental user definitions.

Design verification
Additionally to the type verification, the producer has to provide an article proof which guarantees a correct set-up acc. to the norm, excludes
material failures and the compliance with electrical safety requirements.

Definition – „original manufacturer“ and „manufacturer of the switchgear and control gear assembly“
Original manufacturer
Organisation / enterSockets that executed the original design and the associated verifications in accordance with the standard.

Manufacturer of the switchgear and control gear assembly


Organisation that completes a device and assembles it into a functional unit. The manufacturer is responsible for piece verification and thus for the
product (Declaration of Conformity).

Significance for MENNEKES products:


For pre-wired devices MENNEKES is simultaneously the original manufacturer and the manufacturer. The responsibility and provision of verifications
6
rest with us. We cannot declare partially wired devices that we manufacture as standard compliant. In this case the „finishing entity“ becomes
the manufacturer and must declare conformity. It is required to forward information to this organisation so that the device ultimately can get a
„Declaration of Conformity“.Heating

MENNEKES | 93
Service – Regulations and standards
Heating
The max. ambient temperature is +40 °C.
The average value of the ambient temperature over a period of 24 hours must not be higher than +35 °C.
The verification of heating can be provided through various methods. Through testing of the switchgear and control gear combination, or through
derivation of a known reference, and through an expert assessment, e.g in accordance with applicable design rules. Regardless of the method that
is selected to determine the heat and thus the maximum current load of the combination, compliance with the appropriate temperature limit values
must be ensured.
The switchgear and control gear assembly and its electrical circuits must be capable of bearing their rated currents under defined conditions and the
rated values of the components, their suitability and application must be taken into account, without exceeding limit values specified in IEC 61439-1
Table 6, Part 1. The limit temperatures in table 6 apply for the average ambient temperature of +35 °C.
▶ The limit temperatures of the installed equipment must be taken into account!

Heating – replacement of components


A device/component may only be replaced through a similar, identically constructed device a of a series other than the series used in the verification,
if the power loss, and thus the heating of the connections is less than or equal to that of the device that is being replaced.

Load of the largest electric circuit and of all outgoing circuits individually with rated current
The requirement of IEC 61439 is, that all electric circuits must be individually capable to carry their rated current, without exceeding temperature limit
values in the process. If additional power circuits are added, a rated load factor can be set.

Rated values InA, Inc, RDF


• Rated current of a switchgear and controlgear assembly InA
Rated current that can be distributed by a switchgear and controlgear assembly without exceeding the specified excess temperatures of the various

• Rated current of a main circuit Inc


Rated current that a main circuit can carry if it is the only circuit in a bay of a switchgear assembly that carries a current.

• Rated load factor RDF


Value calculated by dividing the rated operational current of the outgoing main circuit Ing by the rated current Inc of the same outgoing main circuit.
main circuit, where Ing and Inc are determined from tests.

Table 101 from IEC 61439-3 Values for assumed load

Number of outgoing circuits Assumed load factor


2 and 3 0.8
4 and 5 0.7
6, up to and including 9 0.6
10 (and more) 0.5

This table provides guide values, if in doubt the manufacturer‘s specification always applies.

MENNEKES standard values in accordance with Table C of IEC 61439


The information below represents specified standard values for MENNEKES catalogue assemblies. If there are deviations from this standard or in the
case of special project planning, appropriate coordination must take place beforehand between user and manufacturer. These agreements must be
arranged between MENNEKES and the user / customer during the quotation phase (prior to production and prior to sale).
The table below is a „blank“ that is applicable for approximately 98 % of the MENNEKES devices. Special project planning is not covered by the
specifications, and must be separately disclosed by the user prior to project planning. In these special cases, it is required that additional details be
considered with the aid of the standards cited and their product sub-standards (see Section 7.2, in Part 1).

Characteristic Standard value Normative option MENNEKES standard


System according to type of earth Design in accordance with the local TT / TN-C / TN-C-S / IT / TN-S TN / TT
connection requirements
Rated voltage In accordance with local installation max. 1000 V AC or 1500 V DC 400 V AC
conditions
Transient overvoltages determined through the electrical Overvoltage category Kat. III / plugs and sockets Kat. II
system I / II / III / IV
Occasional overvoltages min. rated voltage + 1200 V See Table 8 + 9 or 10 for the 1890 V (AC)
values
Rated frequency In accordance with local installation DC / 50 Hz / 60 Hz 50 Hz
conditions
Short circuit resistance determined through the system N + PE max 60 % of the outer Icc max. ≤ 10 kA
conductor values
SCPD in the supply In accordance with local installation yes / no no
conditions
Coordination between shortcircuit In accordance with local installation present / install / integrate Item-dependent
6 protection devices inside or conditions
outside of the switchgear and
control gear assembly

94 | MENNEKES www.MENNEKES.co.uk
Service – Regulations and standards
Characteristic Standard value Normative option MENNEKES standard
Information of loads that could No loads are permitted that none none
possibly contribute to short-circuit could possibly contribute to the
current shortcircuit current
Type of protection against electric Basic protection Comply with local requirements Basic protection
shock – basic protection
Type of protection against electric Protection against indirect contact / Automatic disconnection of the Item-dependent
shock – earth fault protection comply with local requirements power supply / protective
separation / Double or reinforced
insulation
Installation site Execution of the manufacturer Indoors / outdoors Item-dependent
Protection type Indoors min. IP 2x / IP xx (A-D) IP44
outdoors min. IP23
Protection against mechanical if necessary specification of the IK Information on request
effects code (IEC 62208)
Resistance to UV radiation Required for enclosures in outdoor Information on request
installation
Resistance to corrosion For indoor and outdoor installation yes / no Item-dependent
Ambient temperature limit values Indoors: min. -5 °C none Standard values! see product for
Outdoors: min. -25 °C deviations
High limit (both): +40 °C
max. average value (24 h): +35 °C
Maximum relative humidity indoor: indoor: Standard values! see product for
95 % at -5 °C to +30 °C 95 % at -5 °C to +30 °C deviations
70 % at +35 °C 70 % at +35 °C
57 % at +40 °C 57 % at +40 °C
Outdoor: Outdoor:
100 % at -25 °C to +27 °C 100 % at -25 °C to +27 °C
60 % at 35 °C 60 % at 35 °C
46 % at 40 °C 46 % at 40 °C
Pollution degree Industrial environment 3 1, 2, 3, 4 3
Altitude ≤ 2000 m Pay attention to the factors ≤ 2000 m
EMC environment A or B A/B B
Special operating conditions No particular conditions none Not defined!
(vibration, Ex-area, strong magnetic
fields or contamination)
External structural design in accordance with manufacturer‘s Open / closed / standing / in-wall closed
specifications installation & on-wall installation /
console
Mobile or stationary stationary yes / no Item-dependent
Dimensions and masses in accordance with manufacturer‘s none Item-dependent
specifications
Type of conductors introduced in accordance with manufacturer‘s Cables / busbar trunking systems Cables
from outside specifications
Materials of the conductors Copper Copper / aluminum Copper
introduced from the outside
Cross-sections of the outer As specified in the standard none none
conductors, PE, N & PEN
conductors
Special requirements imposed on in accordance with manufacturer‘s none Manufacturer execution
the marking of connections specifications
Requirements imposed on storage Standard of the manufacturer none Information on request
& transport (type of transport,
deviating ambient conditions,
max. dimensions, packaging
requirements)
Operability (access, activation Easy reachability Authorized persons, ordinary Item-dependent
rights, disconnect) persons, etc.
Requirements imposed on Inspection, component none Inspection, replacement, extension,
accessibility for operation, replacement, extension, maintenance, etc. only through
inspection, maintenance or maintenance, etc. only by specialized persons
extension specialized persons (requirement)
Separation of the outgoing electric in accordance with manufacturer‘s Individually / in groups / all Item-dependent 6
circuits specifications
Type of interior subdivision in accordance with manufacturer‘s Form 1, 2, 3, 4 none
specifications

MENNEKES | 95
Service – Regulations and standards
Characteristic Standard value Normative option MENNEKES standard
Maximum total load current to be Manufacturers standard; in none Item-dependent
supplied by the assembly (from accordance with the application
which the rated current of the
assembly InA (A) will be
determined)
Cross-section ratio between outer Ø ≤ 16 mm² = 100 % For currents in N to 50 % of the Outer conductor = neutral
conductor and N* Ø > 16 mm² = 50 % outer conductors, otherwise a conductor cross-section
(min. 16 mm²) special agreement is necessary!

* MENNEKES designs the size of the Neutral conductor accordingly to the max. allowed current for the phases. For special operating conditions (see IEC 61439, section 7.2 and IEC 61439-1
supplement 1, section 13.5) which relate to the ratio of neutral conductor to outer conductor (alternating current consumption with very low and different cosφ or excessive harmonics in the supply
voltage or load current) can lead to a different size relation between neutral conductor to external conductor. This must be announced by the user.

Clock positions acc. to EN 60309-2:1999 + A1:2007 + A2:2012, Series I (Europe)


Position of ground contact sleeve with respect to major keyway for various voltages and frequencies. The colour codes correspond to the nominal
voltage.

* F or nominal operating voltages and/or frequencies not covered otherwise and for special applications
** Clock positions not used.

96 | MENNEKES www.MENNEKES.co.uk
Service – Regulations and standards
Colour coding
If the rated operating voltage is indicated by a colour coding in addition to compulsory markings, such colour coding must be in accordance with
IEC 60309-1:2013-02, table 2:

Rated operating voltage and frequency Colour code RAL*

100 to 130 V yellow 1021

200 to 250 V blue 5007

380 to 480 V red 3013

500 to 1.000 V black 9005

above 60 to 500 Hz green 6010

*RAL determined by MENNEKES, as in EN 60309-1:2013

CEE plugs and sockets for rated operating voltages above 50 V

Position of the earth contact


Plugs and sockets with rated voltages above 50 V must have an earth contact. To prevent incorrect insertion, a nose on the plug fits into a keyway
in the socket, thus ensuring that the earth contact pin or tube is correctly positioned in accordance with the required electrical standard. The earth
contact positions for the various frequencies and voltages are assigned a clockface position, in accordance with table 104 taken from
EN 60309-2:1999 + A1:2007 + A2:2012 (see below).

CEE plugs and sockets for rated voltages of up to 50 V (low voltage)


Since no earth contact is required in plugs and sockets of rated voltage up to 50 V, two keyways instead of one are provided the collar. They are
accordingly termed the major and minor keyways. The major keyway is always in the 6 o‘clock position. Depending on voltages and frequencies,
the minor keyway is always in accordance with table 103 taken from EN 60309-2 (VDE 0623-2): 2013-01, standard sheet 2-VIII (and in the following
drawings).

Drawing: sockets and connectors U 16/32 A Minor keyway


= 40 to 50 V, 50 to
60 Hz, minor keyway in 12 o‘clock
position

Major
Keyway

Arrangement of the minor keyway (major keyway 6 o‘clock) for various voltages and frequencies using clockface positions in accordance with table
103 taken from EN 60309-2:1999 + A1:2007 + A2:2012

Rated operating Frequency Hz Clockface position of keyway (major keyway = 6 o´clock) Positions 1 and 9 are reserved
voltage V for future standards. For design
reasons, positions 5, 6 and 7 are
20 to 25 50 and 60 no minor keyway not available for use.
40 to 50 50 and 60 12
20 to 25 100 to 200 4
and
300 2
40 to 50
400 3
> 400 to 500 11
DC 10
25 DC* 8 *for portable electrical incubators – use with 12 V or
24 V direct-current voltage in ambulances or
helicopters.

Colour coding
If the rated operating voltage is indicated by a colour coding in addition to compulsory markings, such colour coding must be in accordance with
IEC 60309-1:2013, table 2:

Rated operating voltage Colour code RAL*

20 to 25 V violet 4001

40 to 50 V white 7035
* RAL determined by MENNEKES, as in EN 60309-1:1999 no specification is provided for. 6

MENNEKES | 97
Service – Regulations and standards
Interlocks and breaking capacity
Plugs and sockets without an interlock must have an adequate breaking capacity, i.e. it must be possible to insert and withdraw plugs in the manner
specified and as often as specified. After testing they must exhibit no damage that would impair further use, and the holes for the plug contacts
must not show any significant sign of damage. Sockets and connectors that do not meet the test requirements for breaking capacity and service
characteristics must be fitted with an interlock. An interlock is a mechanical or electrical device which ensures that voltage is only applied to the
contacts of a plug once they have been inserted into a socket or connector as intended, which prevents a plug being withdrawn with the power
switched on or which makes contacts voltage-free before disconnecting. A distinction is made between interlocked plugs and sockets with
- mechanical interlocks
- electrical interlocks.

In the case of sockets and connectors ≥ 63/60 A, EN 60309-2 requires that a distinction is made between products used with or without interlocks.
As MENNEKES plugs and sockets have adequate breaking capacity, standard ≥ 63/60 A versions are fitted with short contact tubes without pilot
contact. In the 63 A and 125 A versions, the short contact tubes meet the finger-touch requirements of IEC 60529. Sockets and connectors 63/60 A
for electrical interlocking are fitted with long contact tubes and pilot contact for leading and lagging. The interlock makes up for the lack of finger-
touch safety.

Plugs and sockets with mechanical interlocks


Mechanical interlocks for plugs and sockets with a rated operating voltage greater than 50 V must conform to EN 60309-2:2013, standard sheet 2-V.
The mechanical switch of a mechanically interlocked socket or connector must not be operational until the proper plug has been inserted. Built-in
switches for mechanical interlocking of switched AC sockets must have a breaking capacity conforming at least to IEC 60947-3 (VDE 0660 part 107),
utilisation category AC 22. The breaking capacity must be suitable for the appliance connected.

Plugs and sockets with electrical interlocks


In the case of plugs and sockets ≥ 63/60 A with a rated operating voltage greater than 50 V intended for electrical interlocking (part no. + index „P“),
a built-in pilot contact can be used to switch off power to a socket or connector. The requisite switch can either be provided in the socket or on the
corresponding circuit distribution board. In the case of sockets with an integrated auxiliary switch fitted behind the pilot tube, the switch is triggered
by the pilot pin of the plug. The advantage of this solution is that the pilot tube itself is not live (PCS interlock).

Plugs and sockets for isolating and switching purposes


In accordance with IEC 0100-460, each electrical circuit must be capable of being disconnected from all active conductors of the power supply.
This also applies for every piece of electrical equipment, which must be capable of being disconnected from the power supply via an installed or
assigned switch. For the term, „disconnect“, the term „isolate“ is also used. As a rule, electrical equipment must be disconnected from the power grid
for mechanical and electrical maintenance tasks. According to DIN VDE 0100-537, plugs and sockets isolating all conductors are suitable for the
disconnection of power for maintenance purposes if they are able to switch off the load current in the electrical equipment in question. A plug and
socket connection is a simple way of satisfying the requirement for „visible isolation“.

Shock hazard protection


Shock hazard protection must be achieved in accordance with EN 60309-1:2013, section 9 by designing plugs and sockets in such a way that, when
engaged properly, no live parts of sockets, connectors, plugs and inlets are exposed so that they may be touched.

It must also be impossible to establish a connection of plugs and connectors while any of the contacts are exposed to touch.

Neutral contact tubes and pilot contacts of sockets and connectors are deemed to be live parts.

Protection type
Plugs and sockets used to be classified according to the degree of protection against the entry of moisture:
– splashproof ⎯▶ drop in a triangle
– watertight ⎯▶ 2 drops

Today, complete IP protection according to IEC 60529, EN 60529 is specified for plugs and sockets, as they are tested in line with this standard.

IP44 = Protection from solid bodies with a diameter ≥ 1 mm, splashproof


IP67 = Protection from dust ingress, protection against temporary immersion

Information on IP protection (IP code) can be found in IEC 60529:2014-09 (VDE 0470 part 1).

Having been properly installed, sockets and connectors must provide the degree of protection defined by the rating, whether the plug is inserted or
not.

The protection type for plugs and inlets only applies if they are in contact with the matching piece of the connector or with a fixed cover, if applicable.

CEE plugs and sockets must be IP44 or IP67. CEE plugs and sockets with rated currents of 100/125 A must be IP67.

100/125 A sockets that are fastened to an enclosure or form a structural unit with the enclosure can be IP44.

For sockets IP67, a bayonet system has been adopted as the standard in order to simplify their use especially under rough working conditions.

IP44 or IP67 is indicated on the appliances.

Notice for the use of mobile power distribution boxes:


Please consider when using SCHUKO® sockets that due to the construction the degree of protection is achieved only when the lid is closed. Otherwise
the ingress of water at the ground contact area may not be prevented (see DIN VDE 0620-1 and DIN 49440 et sqq.)
6

98 | MENNEKES www.MENNEKES.co.uk
Service – Regulations and standards
Degree of protection of SCHUKO® plugs and sockets. Standard change of DIN VDE 620.
For use in mobile devices, in accordance with the current specifications, attachment sockets that satisfy the IP X4 degree of protection requirements
with closed flip-lid cover and with a plugged-in plug in every operating position. Before the standard change in February 2010, the
IP X4 degree of protection was considered as fulfilled if the conditions are satisfied with vertical install position of the sockets. For sockets for
stationary implementation, this also continues to be the case.

Important application instructions concerning the change in the standard.


• The latest amendment of IEC 620 (March 2013) makes a distinction in the case of IP X4 SCHUKO® sockets, between stationary and mobile
implementation conditions
• SCHUKO® IP X4 sockets for stationary and mobile implementation conditions differ in their design (mobile with additional sealing collar, stationary
unchanged).
• SCHUKO® IP X4 connectors, like mobile SCHUKO® IP X4 sockets likewise have a supplemental sealing collar.
Attention!
• SCHUKO® plugs > IP X4 (in accordance with DIN 49442, resistant to pressurised water) when plugged into mobile IP X4 SCHUKO® sockets or
connectors do not achieve adequate contacting due to the design and thus they must not be operated with such sockets!
• The same applies for AC adapters and angled right angle plugs < IP X4!
• On the appropriate SCHUKO® sockets or connectors this circumstance is presented with an engraved right angle SCHUKO® plug with IP X4 mark.
Before processing, ensure that the SCHUKO® articles at hand correspond to the implementation conditions for which they are intended.

Notice for the use of mobile power distribution boxes with RJ45 data sockets:
The installed data sockets without lid have a degree of protection of IP20 which is reducing the degree of the whole unit accordingly.

IP protection types for enclosures in accordance with IEC 60529, EN 60529, IEC 60529 (VDE 0470 part 1)
1st number of the code: 2nd number of the code:
Protection against the ingress of foreign bodies and shock hazard protection. Protection against the ingress of moisture
Code Description Code Description
Enclosure protected Test Protection against Test Enclosure protected Test
against ingress of: contact with: against ingress of:

0 0

Solid body larger Drop of water falling


1 than 50 mm
Back of hand 1 vertically
Gauge probe
Gauge plug
diameter Ø 50 mm
diameter Ø 50 mm

Drop of water
Solid body larger falling vertically on
2 than12.5 mm
Finger 2 enclosure inclined
Gauge plug by up to 15°
Jointed metal finger
diameter Ø 12.5 mm

Solid body larger


3 than 2.5 mm
Tool 3 Water spray

Gauge plug Gauge probe


diameter Ø 2.5 mm diameter Ø 2.5 mm

Solid body larger


4 than 1 mm 4 Splash water
Gauge plug
diameter Ø 1 mm

Dust in harmful
5 quantities
Wire Gauge probe
diameter Ø 1 mm
5 Water jet

Talc

6 Dust overall 6 Strong water jet

Talc

Temporary
7 immersion

By arrangement
between manufacturer
Continuous
8 immersion
and user. Extra severe
test conditions as
compared to code 7

9
Water at high
pressure and steam
6
cleaning

MENNEKES | 99
Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

1 MB 27/30 1 MB 43
Drawing Drawing Amp. 16 32
1 MB 27/30 1 MB 43 Poles 4 5 3 4 5
Dim. in mm a 128 128 128 128 128
Dim. in mm b 84 84 84 84 84
c 122 124 136 136 138
d 11 11 11 11 11
e 68 68 68 68 68
f 5.3 5.3 5.3 5.3 5.3
g. 4 4 4 4 4
h 144 145 158 158 160
M 25 25 32 32 32
M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out
Max. cable diam. (mm) 18 18 18/25 18/25 18/25
Terminal for cond. cross 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —10 —10 —10

1 MB 43/257 1 MB 112
Drawing Amp. 16 32 Drawing Amp. 63
1 MB 43_257 Poles 4 5/7 3 4 5/7 1 MB 112 Poles 3 4 5
Dim. in mm a 128 128 128 128 128 Dim. in mm a 170 170 170
b 84 84 84 84 84 b 118 118 118
c 122 124 136 136 138 c 175 175 175
d 11 11 11 11 11 d 134.5 134.5 134.5
e 68 68 68 68 68 e 103 103 103
f 5.3 5.3 5.3 5.3 5.3 f 6.1 6.1 6.1
g. 4 4 4 4 4 g. 6 6 6
h 144 145 158 158 160 h 219 219 219
M 25 25 32 32 32 M 40 40 40
M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out M* 2x40 (blind) to be cut out
Max. cable diam. (mm) 18 18 18/25 18/25 18/25 Max. cable diam. (mm) 27 27 27
Terminal for cond. cross 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 6 6 6
section (mm2) min.-max. —4 —4 —10 —10 —10 section (mm2) min.-max. —25 —25 —25

1 MB 136 1 MB 137
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 136 Poles 2 3 2 3 1 MB 137 Poles 2 3 2 3
Dim. in mm a 55 55 55 55 Dim. in mm a 128 128 128 128
b 55 55 55 55 b 84 84 84 84
c 44 44 44 44 c 120 120 120 120
d 45 45 45 45 d 11 11 11 11
e 45 45 45 45 e 68 68 68 68
f 4.2 4.2 4.2 4.2 f 5.3 5.3 5.3 5.3
g. 8 8 8 8 g. 4 4 4 4
g.1 2 2 2 2 h 146 146 146 146
h 67 67 67 67 M 25 25 32 32
k 22 22 22 22 M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out
l 34 34 34 34 Max. cable diam. (mm) 18 18 25 25
Terminal for cond. cross 4 4 4 4 Terminal for cond. cross 4 4 4 4
section (mm2) min.-max. —10 —10 —10 —10 section (mm2) min.-max. —2x6 —10 —2x6 —10

1 MB 141 1 MB 162
Drawing Amp. 16 32 Drawing Amp. 125
1 MB 141 Poles 3 4 5 3 4 5 1 MB 162 Poles 4 5
Dim. in mm a 75 75 75 85 85 85 Dim. in mm a 264 264
b 75 75 75 75 75 75 b 163 163
c 60 61 61 70 70 72 c 200 200
d 60 60 60 60 60 60 d 240 240
e 60 60 60 60 60 60
e 140 140
f 5.5 5.5 5.5 5.5 5.5 5.5
f 8.1 8.1
g. 8 8 8 8 8 8
g.1 2 2 2 2 2 2 g 8 8
h 83 88 95 99 99 105 h 306 306
i 78 85 96 103 103 110 M 50 50
k 31 32 32 39 39 39 M* 50 50
l 43 52 54 58 58 65 Max. cable diam. (mm) 38 38
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 25 25
section (mm2) min.-max. —4 —4 —4 —10 —10 —10 section (mm2) min.-max. —35 —35

1 MB 168 1 MB 177
Drawing Amp. 16 32 Drawing Amp. 125
1 MB 168 Poles 3 4 5 3 4 5 1 MB 177 Poles 3 4 5
Dim. in mm a 225 225 225 225 225 225 Dim. in mm a 460 460 460
b 118 118 118 118 118 118 b 260 260 260
c 141 141 141 146 146 146 c 270 270 270
d 208 208 208 208 208 208 d 434 434 434
e 101 101 101 101 101 101 e 234 234 234
f 6.3 6.3 6.3 6.3 6.3 6.3 f 11 11 11
g. 8 8 8 8 8 8 g. 9 9 9
h 250 252 254 264 264 264 h 519 519 519
M 1x25 and 1x32 1x25 and 1x32 M 63 63 63
M* 2x25 2x25 2x25 2x25 2x25 2x25 M* 2x63 2x63 2x63
Max. cable diam. (mm) 25 25 25 25 25 25 Max. cable diam. (mm) 44 44 44
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 25 25 25
section (mm2) min.-max. —4 —4 —4 —10 —10 —10 section (mm2) min.-max. —70 —70 —70

1 MB 180 1 MB 181/620
Drawing Amp. 63 Drawing Amp. 16 32 63
1 MB 180 Poles 3 4 5 1 MB 181/620 Poles 3 4 5 4 5 4 5
Dim. in mm a 260 260 260 Dim. in mm a 364 364 364 364 364 460 460
b 160 160 160 b 134 134 134 134 134 180 180
c 198 198 198 c 160 162 163 168 168 202 202
d 240 240 240 d 347 347 347 347 347 440 440
e 140 140 140 e 117 117 117 117 117 160 160
f 8.1 8.1 8.1 f 6.3 6.3 6.3 6.3 6.3 8.1 8.1
6 g.
h 303
8
303
8
303
8 g.
h 391
8
395
8
398
8 8
408 411
8 8
505 505
8

M 40 40 40 M 32/40 32/40 32/40 32/40 32/40 40 40


M* 2 x 40 2 x 40 2 x 40 M* 2x32 2x32 2x32 2x32 2x32 2x40 2x40
Max. cable diam. (mm) 27 27 27 Max. cable diam. (mm) 27 27 27 27 27 27 27
Terminal for cond. cross 6 6 6 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 6 6
section (mm2) min.-max. —25 —25 —25 section (mm2) min.-max. —4 —4 —4 —10 —10 —25 —25

100 | MENNEKES www.MENNEKES.co.uk


Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

1 MB 209 1 MB 211
Drawing Amp. 16 Drawing Amp. 63
1 MB 209 Poles 3 4 5 1 MB 211 Poles 3 4 5
Dim. in mm a 87 100 100 Dim. in mm a 107 107 107
b 64 75 75 b 100 100 100
c 99 110 113 c 80 80 80
d 40 – –
d 85 85 85
d1 – 11 11
e 77 77 77
e 50 59 59
f 6 6 6
f 4.5 5 5
g. 4 4 4
g. 12 12 12
h 115 125 128 g.1 2 2 2
M 20 20 20 h 113 113 113
M* M20 (blind) to be cut out k 55 55 55
Max. cable diam. (mm) 15 15 15 l 88 88 88
Terminal for cond. cross 1.5 1.5 1.5 Terminal for cond. cross 6 6 6
section (mm2) min.-max. —4 —4 —4 section (mm2) min.-max. —25 —25 —25

1 MB 212/258 1 MB 213
Drawing Amp. 63 125 Drawing Amp. 63
1 MB 212/258 Poles 3 4 5 4 5 1 MB 213 Poles 3 4 5
Dim. in mm a 107 107 107 130 130 Dim. in mm a 170 170 170
b 100 100 100 130 130 b 118 118 118
c 81 81 81 119 119 c 164 164 164
d 85 85 85 104 104
d 134.5 134.5 134.5
e 77 77 77 104 104
f 6 6 6 6.5 6.5 e 103 103 103
g 12 12 12 18 18 f 6.1 6.1 6.1
g.1 2 2 2 2 2 g. 6 6 6
h 117 117 117 129 129 h 216 216 216
i 113 113 113 126 126 M 40 40 40
k 55 55 55 43 43 M* 2xM40 (blind) to be cut out
l 88 88 88 95 95 Max. cable diam. (mm) 32 32 32
Terminal for cond. cross 6 6 6 25 25 Terminal for cond. cross 6 6 6
section (mm2) min.-max. —25 —25 —25 —70 —70 section (mm2) min.-max. —25 —25 —25

1 MB 217/1 1 MB 231
Drawing Amp. 16 32 63 Drawing Amp. 16 32
1 MB 217/1 Poles 3 5 3 5 5 1 MB 231 Poles 2 3 2 3
Dim. in mm a 75 75 85 85 107 Dim. in mm a 68 68 68 68
b 75 75 75 75 100
b 62 62 62 62
c 60 60 67 73 82
d 60 60 60 60 85 c 42 42 42 42
e 60 60 60 60 77 d 53 53 53 53
f 5.5 5.5 5.5 5.5 6.5 e 47 47 47 47
g. 8 8 8 8 12 f 4.5 4.5 4.5 4.5
g.1 2 2 2 2 2 g. 8 8 8 8
h 81 95 95 106 115 g.1 2 2 2 2
i 70 88 94 102 114 h 72 72 72 72
k 26 27 34 34 55 k 32 32 32 32
l 52 57 58 65 88 l 55 55 55 55
Terminal for cond. cross 1.5 1.5 2.5 2.5 6 Terminal for cond. cross 4 4 4 4
section (mm ) min.-max.
2
—4 —4 —10 —10 —25
section (mm2) min.-max. —10 —10 —10 —10

1 MB 234 1 MB 236
Drawing Amp. 63 Drawing Amp. 32
1 MB 234 Poles 3 4 5 1 MB 236 Poles 3
Dim. in mm a 264 264 264 Dim. in mm a 100
b 163 163 163 b 92
c 192 192 192 c 42
d 240 240 240 d 85
e 140 140 140 e 77
f 8.1 8.1 8.1 f 5.1
g. 8 8 8
g. 8
h 300 300 300
g.1 2
M 40 40 40
k 31
M* 2x40 2x40 2x40
Max. cable diam. (mm) 27 27 27 l 60
Terminal for cond. cross 6 6 6 Terminal for cond. cross 4
section (mm2) min.-max. —25 —25 —25 section (mm2) min.-max. —10

1 MB 251 1 MB 260
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 251 Poles 3 4 5 3 4 5 1 MB 260 Poles 3 4 5 3 4 5
gle
le

an

Dim. in mm a 73.5 100 100 100 100 100 Dim. in mm a 73.5 100 100 100 100 100
ang

b 64 92 92 92 92 92 b 64 92 92 92 92 92
c 52 60 62 64 64 66 c 50 59 58 62 62 61
d 60 85 85 85 85 85 d 60 85 85 85 85 85
e 52 77 77 77 77 77 e 52 77 77 77 77 77
f 5.5 5.5 5.5 5.5 5.5 5.5 f 5.5 5.5 5.5 5.5 5.5 5.5
g. 8 8 8 8 8 8
g. 7 8 8 8 8 8
g.1 2 2 2 2 2 2
g.1 2 2 2 2 2 2
h 84 100 105 109 109 113
i 78 85 96 103 103 110 h 79 100 100 103 103 106
k 43 32 32 53 53 45 k 44 34 34 54 54 49
l 52 55 65 67 67 72 l 52 55 65 67 67 72
l1 60 63 72 82 82 85 l1 60 63 72 82 82 85
α 20° 20° 20° 20° 20° 20° α 20° 20° 20° 20° 20° 20°
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —10 —10 —10 section (mm2) min.-max. —4 —4 —4 —10 —10 —10

1 MB 292 1 MB 294
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 292 Poles 2 3 2 3 1 MB 294 Poles 2 3 2 3
Dim. in mm a 75 75 75 75 Dim. in mm a 96 96 96 96
b 75 75 75 75 b 73 73 73 73
c 44 44 44 44 c 90 90 90 90
d 60 60 60 60 d 53 53 53 53
e 60 60 60 60 d1 52 52 52 52
f 5.5 5.5 5.5 5.5
g.
g.1
8
2
8
2
8
2
8
2
d2
e
f
62
2

5.3
2
62
5.3
2
62
5.3
2
62
5.3
6
h 77 77 77 77
k 22 22 22 22 g 8 8 8 8
l 34 34 34 34 h 129 129 129 129
Terminal for cond. cross 4 4 4 4 Terminal for cond. cross 4 4 4 4
section (mm2) min.-max. —10 —10 —10 —10 section (mm2) min.-max. —10 —10 —10 —10

MENNEKES | 101
Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

1 MB 297 1 MB 298/601
Drawing Amp. 63 1 MB 298 Amp. 63 125
1 MB 297 Poles 3 4 5 1 MB 601 Poles 3 4 5 3 4 5
Dim. in mm a 110 110 110 Dim. in mm a 110 110 110 114 114 114
b 106 106 106 110 110 110
b 106 106 106
c 85 85 85 75 75 75
c 82 82 82 d 85 85 85 90 90 90
d 85 85 85 e 77 77 77 90 90 90
e 77 77 77 f 6.2 6.2 6.2 6.2 6.2 6.2
f 6.5 6.5 6.5 g. 12 12 12 13 13 13
g. 12 12 12 g.1 2 2 2 2 2 2
g.1 2 2 2 h 128 128 128 133 133 133
i 113 113 113 126 126 126
h 122 122 122
k 67 67 67 103 103 103
k 69 69 69 l 92 92 92 94 94 94
R 46 46 46 l1 98 98 98 107 107 107
α 20° 20° 20° ˂ 20° 20° 20° 15° 15° 15°
Terminal for cond. cross 6 6 6 Terminal for cond. cross 6 6 6 25 25 25
section (mm2) min.-max. —25 —25 —25 section (mm2) min.-max. —25 —25 —25 70 70 70

1 MB 305 1 MB 312
Drawing Drawing Amp. 16 32
1 MB 305 1 MB 312 Poles 3 4 5 3 4 5
Dim. in mm a 93 93 93 93 93 93
Dim. in mm b 90 90 90 90 90 90
c 87 87 87 99 99 99
d 75 75 75 75 75 75
e 73 73 73 73 73 73
Fixing details f 5.5 5.5 5.5 5.5 5.5 5.5
g. 4.2 4.2 4.2 4.2 4.2 4.2
k 33 33 33 33 33 33
y 25.5 25.5 25.5 25.5 25.5 25.5
M 25x1.5 25x1.5 25x1.5 25x1.5 25x1.5 25x1.5
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 313 1 MB 315
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 313 Poles 3 4 5 3 4 5 1 MB 315 Poles 3 4 5 3 4 5
Dim. in mm a 93 93 93 93 93 93 Dim. in mm k 32 32 32 48 48 48
b 90 90 90 90 90 90 l 50 60 67 65 65 73
c 90 90 90 102 102 102 m - - - 70 70 76
d 75 75 75 75 75 75
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
e 73 73 73 73 73 73
section (mm2) min.-max. —4 —4 —4 —6 —6 —6
f 5.5 5.5 5.5 5.5 5.5 5.5
g. 4.2 4.2 4.2 4.2 4.2 4.2
k 36 36 36 36 36 36
y 25.5 25.5 25.5 25.5 25.5 25.5
M 25x1.5 25x1.5 25x1.5 25x1.5 25x1.5 25x1.5
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 317 1 MB 336
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 317 Poles 3 4 5 3 4 5 1 MB 336 Poles 3 4 5 3 4 5
Dim. in mm a 93 93 93 93 93 93 Dim. in mm a 93 93 93 93 93 93
b 90 90 90 90 90 90 b 90 90 90 90 90 90
c 88 88 88 100 100 100
c 95 95 95 95 95 95
d 75 75 75 75 75 75
e 73 73 73 73 73 73 h 111 111 111 111 111 111
f 5.5 5.5 5.5 5.5 5.5 5.5 i 124 124 124 124 124 124
g. 4.2 4.2 4.2 4.2 4.2 4.2 k 33 33 33 33 33 33
k 34 34 34 34 34 34 n 91 91 91 91 91 91
y 25.5 25.5 25.5 25.5 25.5 25.5
o 95 95 95 95 95 95
M 25x1.5 25x1.5 25x1.5 25x1.5 25x1.5 25x1.5
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —6 —6 —6 section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 339 1 MB 347
Drawing Amp. 125 Drawing
1 MB 339 Poles 4 5 1 MB 347
Dim. in mm a 114 114
b 110 110
Dim. in mm
c 85 85
d 90 90
e 90 90
f 6.2 6.2
g. 13 13
g.1 2 2
h 135 135
i 135 135
k 103 103
R 47 47
α 15° 15°
Terminal for cond. cross 25 25
section (mm2) min.-max. 70 70 closed by membrane

1 MB 350 1 MB 354
Drawing Amp. 16 Drawing Amp. 16 32
1 MB 350 Poles 3 4 5 1 MB 354 Poles 4 5 5
Dim. in mm Dim. in mm a 141 141 141
Terminal for cond. cross 1.5 1.5 1.5 b 84 84 85
Membrane section (mm2) min.-max. —4 —4 —4 c 136 140 158
d 61 61 61
e 68 68 68

6 f
g.
h
5.5

142
5
5.5

145
5
5.5

161
5

M 25 25 25
Membrane Ø 28,7 Max. cable diam. (mm) 18 18 18
Terminal for cond. cross 1.5 1.5 2.5
section (mm2) min.-max. —4 —4 —10

102 | MENNEKES www.MENNEKES.co.uk


Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

1 MB 378 1 MB 382
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 378 Poles 3 4 5 4 5 1 MB 382 Poles 7 7
Dim. in mm a 225 225 225 225 225 Dim. in mm a 225 225
b 118 118 118 118 118 b 118 118
c 144 146 147 152 153 c 147 153
d 208 208 208 208 208 d 208 208
e 101 101 101 101 101 e 101 101
f 6.3 6.3 6.3 6.3 6.3 f 6.3 6.3
g. 8 8 8 8 8 g. 8 8
h 252 255 259 268 274 h 259 274
M 1x25 and 1x32 1x25 and 1x32 M 1x25 and 1x32 1x25 and 1x32
M* 2x25 2x25 2x25 2x25 2x25 M* 2x25 2x25
Max. cable diam. (mm) 25 25 25 25 25 Max. cable diam. (mm) 25 25
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 Terminal for cond. cross 1.5 2.5
section (mm2) min.-max. —4 —4 —4 —10 —10 section (mm2) min.-max. —4 —10

1 MB 410 1 MB 412/3
Drawing Drawing Amp. 25 40 80
1 MB 410 1 MB 412/3 Pole 3/3+HS 3/3+HS 3/3+HS
Dim. in mm A 170 263 263
Dim. in mm
B 118 168.5 168.5

C 98 130 130

D 131 161 161

Installation dimensions in mm

1 MB 421 1 MB 422
Drawing Drawing
1 MB 421 1 MB 422

Dim. in mm Dim. in mm

Acceptance angle ~ 106°

1 MB 426 1 MB 450
Drawing Amp. 16 Drawing
1 MB 426 Poles 3 1 MB 450 Dim. A
Dim. in mm a 55 Dim. in mm
b 55
c 54
d 45 SCHUKO 18.3
e 45 French/Belgian standards 15.8
f 5.5 Danish standards 15.8
g. 8
g.1 2
h 70
h1 12
k 28
I 47
Terminal for cond. cross 1.5
section (mm2) min.-max. —4

1 MB 451 1 MB 452
Drilled holes to accommodate the Drawing Drawing Amp. 16 32
4 round steel chains which are 1 MB 451 1 MB 452 Poles 3 4 5 3 4 5
Dim. in mm a 85 85 85 85 85 85
held together with a 6 mm b 85 85 85 85 85 85
Dim. in mm
karabiner c 57 59 60 68 68 72
d 70 70 70 70 70 70
e 70 70 70 70 70 70
le

With holes for front


ang

f 5.5 5.5 5.5 5.5 5.5 5.5


and rearinstallation for g 8 8 8 8 8 8
enclosures g.1 2 2 2 2 2 2
h 87 91 99 105 105 110
i 78 85 96 103 103 110
260 x 225 mm or k 39 34 33 53 53 41
390 x 172 mm I min. 57 64 70 78 78 78
I max. 78 78 78 78 78 78
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
Part no. 18444 section (mm2) min.-max. —4 —4 —4 —10 —10 —10

1 MB 453 1 MB 456
Drawing Amp. 16 32 Drawing Amp. 16
1 MB 453 Poles 3 4 5 3 4 5 1 MB 456 Poles 3
Dim. in mm a 85 85 85 85 85 85 Dim. in mm a 68
b 85 85 85 85 85 85 b 62
c 53 57 57 60 60 67 c 52
d 70 70 70 70 70 70 d 47
e 70 70 70 70 70 70 e 47
le

Øf 5.5
ang

f 5.5 5.5 5.5 5.5 5.5 5.5


g. 8
g
g.1
h 89
8
2
96
8
2
101
8
2
103
8
2
103
8
2
110
8
2
g.1
h
i
1.5
74
64
6
k 39 34 33 53 53 41 k 37
I min. 57 64 70 78 78 78 l 52
I max. 78 78 78 78 78 78 l1 56
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 1.5
section (mm2) min.-max. —4 —4 —4 —10 —10 —10 section (mm2) min.-max. —4

MENNEKES | 103
Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

1 MB 463 1 MB 464
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 463 Poles 3 4 5 3 4 5 1 MB 464 Poles 3 4 5 3 4 5
Dim. in mm a 95 93 92.5 102 102 102 Dim. in mm a 75 75 75 75 75 75
b 73.5 87.5 87.5 94 94 94 b 75 75 75 75 75 75
c 93 107.5 110 115.5 115.5 119.5 c 53 53 54 64 64 64
d 55.5 55.5 55.5 62 62 62
d 60 60 60 60 60 60
e 60 60 60 60 60 60
e 61 76 76 84 84 84
f 5.5 5.5 5.5 5.5 5.5 5.5
f1 5.3 5.3 5.3 5.1 5.1 5.1 g. 8 8 8 8 8 8
f2 5.3 5.3 5.3 5.1 5.1 5.1 g.1 2 2 2 2 2 2
h 139 139 136.5 160 160 156.5 h 75 80 85 89 89 95
i 19.8 21.5 21.5 26.5 26.5 26.5 h1 5 8 10 10 12
M M20x M25x M25x M25x M32x M32x k 22 22 22 28 28 28
1.5 1.5 1.5 1.5 1.5 1.5 l 43 52 57 60 60 64
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —6 —6 —6 section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 465 1 MB 466
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 465 Poles 3 4 5 3 4 5 1 MB 466 Poles 3 4 5 3 4 5
Dim. in mm a 73.5 100 100 100 100 100 Dim. in mm a 73.5 100 100 100 100 100
b 64 92 92 92 92 92 b 64 92 92 92 92 92
c 52 58 58 61 61 60 c 52 60 62 66 66 66
d 60 85 85 85 85 85 d 60 85 85 85 85 85
e 52 77 77 77 77 77 e 52 77 77 77 77 77
f 5.5 5.5 5.5 5.5 5.5 5.5 f 5.5 5.5 5.5 5.5 5.5 5.5
g. 7 8 8 8 8 8 g. 7 8 8 8 8 8
g.1 2 2 2 2 2 2 g.1 2 2 2 2 2 2
h 79 100 100 103 103 105 h 84 100 106 109 109 113
k 31 31 31 44 44 54 k 31 31 31 44 44 54
l 52 55 65 70 70 73 l 52 55 65 70 70 73
l1 60 63 72 82 82 85 l1 60 63 72 82 82 85
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —6 —6 —6 section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 467 1 MB 472
Drawing Amp. 16 32 Drawing Amp. 16
1 MB 467 Poles 3 4 5 3 4 5 1 MB 472 Poles 3
Dim. in mm a 75 75 75 85 85 85 Dim. in mm a 68
b 75 75 75 75 75 75 b 62
c 60 61 61 69 69 72 c 52
d 60 60 60 60 60 60 d 47
e 60 60 60 60 60 60
e 47
f 5.5 5.5 5.5 5.5 5.5 5.5
f 5.5
g. 8 8 8 8 8 8
g.1 2 2 2 2 2 2 g. 8
h 83 88 95 99 99 105 g.1 1.5
i 78 85 96 103 103 110 h 76
k 21 21 21 28 28 38 k 37
l 43 52 54 60 60 65 Terminal for cond. cross 1.5
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 section (mm2) min.-max. —4
section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 474 1 MB 519
Drawing Amp. 16 32 63 Drawing Amp. 16 32
1 MB 474 Pole 3 5 3/4 5 3/4/5
1 MB 519 Poles 3 4 5 3 4 5
Dim. in mm a 85 85 85 85 114
b 85 85 85 85 114 Dim. in mm a 85 85 85 85 85 85
c 71 65 65 80 98 b 85 85 85 85 85 85
d 70 70 70 70 90 c 52 57 55 61 60 66
e 70 70 70 70 90 d 70 70 70 70 70 70
f 5.5 5.5 5.5 5.5 5.5 e 70 70 70 70 70 70
g 8 8 8 8 12 f 5.5 5.5 5.5 5.5 5.5 5.5
g.1 2 2 2 2 2 g 8 8 8 8 8 8
h 92 98 101 115 135 g.1 2 2 2 2 2 2
i 70 87 94 101 112 h 86 96 100 96 104 110
k 39 33 53 53 70 k 31 32 33 43 44 48
I min. 57 70 78 78 92 I min. 57 64 70 78 78 78
I max. 78 78 78 78 105 I max. 76 76 76 78 78 78
l1 — — — — 105 ∂ 20 20 20 20 20 20
Terminal for cond. cross 1.5 1.5 2.5 2.5 6 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —10 —10 —25 section (mm2) min.-max. —4 —4 —4 —10 —10 —10

1 MB 520 1 MB 523
Drawing Amp. 16 32 Drawing 1 MB 531
1 MB 520 Poles 3 4 5 3 4 5
Dim. in mm a 85 85 85 85 85 85 Depth dimensions at various fittings.
b 85 85 85 85 85 85 Sockets Degrees Depth
c 56 59 59 64 64 71 SCHUKO®16A, 230 V IP 44 175 mm
d 70 70 70 70 70 70 IP 67 194 mm
e 70 70 70 70 70 70 CEE 16A, 3p, 230V IP 44 204 mm
f 5.5 5.5 5.5 5.5 5.5 5.5
IP 67 205 mm
g 8 8 8 8 8 8
CEE 16A, 5p, 400V IP 44 209 mm
g.1 2 2 2 2 2 2
IP 67 213 mm
h 87 91 99 103 103 110
CEE 32A, 5p, 400V IP 44 221 mm
i 78 85 89 103 103 106
IP 67 227 mm
k 32 32 33 44 44 49
CEE 63A, 5p, 400V IP 44 248 mm
I min. 57 64 70 78 78 78
IP 67 248 mm
I max. 76 76 76 78 78 78
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Cable entries: closed for cut out. 2 x M 25 each on top and bottom,
section (mm2) min.-max. —4 —4 —4 —6 —6 —6 2 x M 20 each on top and bottom for cut out.

1 MB 550 1 MB 551
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 550 Poles 3 4 5 3 4 5 1 MB 551 Poles 3 4 5 3 4 5
Dim. in mm a 225 225 225 225 225 225 Dim. in mm a 225 225 225 225 225 225
b 168 168 168 168 168 168 b 168 168 168 168 168 168
b1 130 130 130 130 130 130 b1 130 130 130 130 130 130
c 80 80 80 80 80 80 c 80 80 80 80 80 80
c1 166 166 166 166 166 166 c1 166 166 166 166 166 166
c2 182 183 183 193 193 193 c2 182 185 186 197 197 198

6 d
d1
204
145
204
145
204
145
204
145
204
145
204
145
d
d1
e
204
145
150
204
145
150
204
145
150
204
145
150
204
145
150
204
145
150
e 150 150 150 150 150 150
f 7 7 7 7 7 7
f 7 7 7 7 7 7
f1 Ø7 Ø7 Ø7 Ø7 Ø7 Ø7
f1 Ø7 Ø7 Ø7 Ø7 Ø7 Ø7
g 8 8 8 8 8 8
g 8 8 8 8 8 8

104 | MENNEKES www.MENNEKES.co.uk


Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

1 MB 584 1 MB 586
Drawing Drawing
1 MB 584 1 MB 586

Dim. in mm

1 MB 622 1 MB 627
Drawing Amp. 16 32 Drawing
1 MB 622 Poles 3 4 5 3 4 5 1 MB 627
Dim. in mm a 100 100 100 100 100 100
b 101 101 101 109 109 109 Dim. in mm
c 117 125 131 157 157 160
d 50 50 50 50 50 50
e 84 84 84 92 92 92
f1 5.3 5.3 5.3 5.3 5.3 5.3
f2 5.3 5.3 5.3 5.3 5.3 5.3
g 6.5 6.5 6.5 6.5 6.5 6.5
h 131 131 132 148 148 148
i 24.7 24.7 24.7 27.5 27.5 27.5
M 25 (optional M20) 32 (optional M25)
M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out
Max. cable diam. (mm) 18 (M25) and 15 (M20) 25 (M32) and 18 (M25)
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —6 —6 —6

1 MB 713 1 MB 714
Drawing Amp. 16 32 Drawing Amp. 16 32
1 MB 713 Poles 3 4 5 3 4 5 1 MB 714 Poles 3 4 5 3 4 5
Dim. in mm a 225 225 225 225 225 225 Dim. in mm a 225 225 225 225 225 225
b 118 118 118 118 118 118 b 118 118 118 118 118 118
c 160 160 160 162 162 162 c 163 163 165 168 168 169
d 208 208 208 208 208 208 d 208 208 208 208 208 208
e 101 101 101 101 101 101 e 101 101 101 101 101 101
f 6.4 6.4 6.4 6.4 6.4 6.4 f 6.4 6.4 6.4 6.4 6.4 6.4
g. 5 5 5 5 5 5 g. 5 5 5 5 5 5
h 238 244 243 249 249 250 h 241 245 249 252 252 255
α 25 25 α 25 25
M 1x25 and 1x32 1x25 and 1x32 M 1x25 and 1x32 1x25 and 1x32
M* 2x25 2x25 2x25 2x25 2x25 2x25 M* 2x25 2x25 2x25 2x25 2x25 2x25
Max. cable diam. (mm) 25 25 25 25 25 25 Max. cable diam. (mm) 25 25 25 25 25 25
Terminal for cond. cross 2.5 2.5 2.5 2.5 2.5 2.5 Terminal for cond. cross 2.5 2.5 2.5 2.5 2.5 2.5
section (mm2) min.-max. —10 —10 —10 —10 —10 —10 section (mm2) min.-max. —10 —10 —10 —10 —10 —10

2 MB 32 2 MB 36
Drawing Amp. 16 32 Drawing Amp. 63 125
2 MB 32 Poles 3 4 5 3 4 5 2 MB 36 Poles 3 4 5 4 5
Dim. in mm a 87 100 100 128 128 128 Dim. in mm a 170 170 170 264 264
b 64 75 75 84 84 84 b 118 118 118 163 163
c 93 106 110 133 133 135 c 171 171 171 205 205
d 40 — — — — — d 134.5 134.5 134.5 240 240
d1 — 10.5 10.5 11 11 11 e 103 103 103 140 140
e 50.5 59 59 68 68 68 f 6,1 6,1 6,1 8,1 8,1
f 4,5 5 5 5.3 5.3 5.3 g. 6 6 6 8 8
g. 4 4 4 4 4 4 h 250 250 250 355 355
h 122 133 135 169 169 170 M 40 40 40 50 50
M 20 20 20 32 32 32 M* 2x40 2x40 2x40 50 50
M* 1x20 (blind) to be cut out 2x25 (blind) to be cut out α 25° 25° 25° 20° 20°
Max. cable diam. (mm) 15 15 15 18/25 18/25 18/25 Max. cable diam. (mm) 27 27 27 38 38
Terminal for cond. cross 1 1 1 2.5 2.5 2.5 Terminal for cond. cross 6 6 6 16 16
section (mm2) min.-max. —2.5 —2.5 —2.5 —6 —6 —6 section (mm2) min.-max. —16 —16 —16 —35 —35

2 MB 40 2 MB 43
Drawing Amp. 16 32 63 Drawing Amp. 16 32
2 MB 40 Poles 5 3 4 5 4 5 2 MB 43 Poles 4 5 3 4 5
Dim. in mm a 85 85 85 85 114 114 Dim. in mm a 85 85 75 75 75
b 85 85 85 85 114 114 b 85 85 90 90 90
c 141 141 141 144 180 180 c 104 106 115 115 117
d 70 70 70 70 90 90 d 64 64 45 45 45
e 70 70 70 70 90 90 d1 10 10 13 13 13
f 6.2 6.2 6.2 6.2 6.2 6.2 e 64 64 78 78 78
g. 6 6 6 6 6 6 f 5.5 5.5 5.5 5.5 5.5
g.1 2 2 2 2 2 2 g. 27 27 27 27 27
h 181 181 181 188 242 242 g.1 2 2 1 1 1
s 86 93 93 100 113 113 h 140 140 150 150 150
l 30 30 30 30 40 40 l 50 50 55 55 55
Terminal for cond. cross 1 2.5 2.5 2.5 4 4 Terminal for cond. cross 1 1 2.5 2.5 2.5
section (mm2) min.-max. —2.5 —6 —6 —6 —16 —16 section (mm2) min.-max. —2.5 —2.5 —6 —6 —6

2 MB 62/1 2 MB 68
Drawing Amp. 16 32 63 Drawing Amp. 16 32
2 MB 62/1 Poles 3 5 3 5 5 2 MB 68 Poles 5 5
Dim. in mm a 85 85 85 85 106 Dim. in mm a 66 72
b 85 85 85 85 101 a1 69 78
b 66 72
c 128 128 129 135 152
c 43 52
d 70 70 70 70 85 d 52 60
e 70 70 70 70 77 e 52 60
f
g.
6.3
11
6.3
11
6.3
11
6.3
11
6.5
12
f
g.
4.5
4.5
4.5
4.5
6
h 105 107 108 111 130 g.1 2 2
k 27 32
s 70 86 92 101,5 114
l 59 63
Terminal for cond. cross 1 1 2.5 2.5 4 Terminal for cond. cross 1 2.5
section (mm2) min.-max. —2.5 —2.5 —6 —6 —10 section (mm2) min.-max. —2.5 —6

MENNEKES | 105
Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

2 MB 68/853 2 MB 70
Drawing Amp. 16 Drawing
2 MB 68/853 Poles 5 2 MB 70
Dim. in mm a 75
b 75 Dim. in mm
c 42
d 60
e 60
f 5.5
g. 7.3
g.1 2
k 13
l 52
Terminal for cond. cross 1
section (mm2) min.-max. —2.5

2 MB 71 2 MB 73
Drawing Amp. 16 32 Drawing Amp. 16 32
2 MB 71 Poles 7 7 2 MB 73 Poles 4 5 3 4 5
Dim. in mm a 85 75 Dim. in mm a 85 85 75 75 75
b 85 90 b 85 85 90 90 90
c 79 90 c 75 79 87 87 90
d 64 45 d 64 64 45 45 45
d1 10 10 13 13 13
d1 10 13
e 64 64 78 78 78
e 64 78
f 5.5 5.5 5.5 5.5 5.5
f 5.5 5.5
g. 6 6 6 6 6
g. 6 6 g.1 2 2 2 2 2
g.1 2 2 h 129 129 137 137 138
h 129 138 l 50 50 55 55 55
Terminal for cond. cross 1 2.5 Terminal for cond. cross 1 1 2.5 2.5 2.5
section (mm2) min.-max. —2.5 —6 section (mm2) min.-max. —2.5 —2.5 —6 —6 —6

2 MB 147 2 MB 155
Drawing Amp. 16 32 Drawing Amp. 63
2 MB 147 Poles 7 7 2 MB 155 Poles 3 4 5
Dim. in mm a 100 128 Dim. in mm a 110 110 110
b 75 84
b 106 106 106
c 110 135
d — — c 86 86 86
d1 10.5 11 d 90 90 90
e 59 68 e 90 90 90
f 5 5.3 f 5.5 5.5 5.5
g. 4 4
h 135 170
g. 12 12 12
M 20 32 g.1 2 2 2
M* 20 (blind) to be cut out 2x25 (blind) to be cut out k 28 28 28
l 88.5 88.5 88.5
Max. cable diam. (mm) 15 18
Terminal for cond. cross 6 6 6
Terminal for cond. cross 1 2.5
section (mm2) min.-max. —2.5 —4
section (mm2) min.-max. —16 —16 —16

2 MB 160 2 MB 166
Drawing Amp. 16 32 Drawing Amp. 63 125
2 MB 160 Poles 2 3 2 3 2 MB 166 Poles 3 4 5 3 4 5
Dim. in mm a 96 96 96 96 Dim. in mm a 110 110 110 130 130 130
b 73 73 73 73 b 106 106 106 130 130 130
c 74 74 74 74 c 86 86 86 112 112 112
d 53 53 53 53 d 90 90 90 104 104 104
d1 52 52 52 52 e 90 90 90 104 104 104
f 5.5 5.5 5.5 6.5 6.5 6.5
d2 2 2 2 2
g. 12 12 12 18 18 18
e 62 62 62 62 g.1 2 2 2 2 2 2
f 5.3 5.3 5.3 5.3 k 28 28 28 28 28 28
g. 8 8 8 8 l 88.5 88.5 88.5 98 98 98
h 116 116 116 116 s 113 113 113 132 132 132
Terminal for cond. cross 4 4 4 4 Terminal for cond. cross 6 6 6 25 25 25
section (mm2) min.-max. —10 —10 —10 —10 section (mm2) min.-max. —16 —16 —16 —70 —70 —70

2 MB 173/2 2 MB 187/2
Drawing Amp. 16 32 Drawing Amp. 16 32
2 MB 173/2 Poles 3 4 5 3 4 5 2 MB 187/2 Poles 3 4 5 3 4 5
Dim. in mm a 85.7 85.7 85.7 85.7 85.7 85.7 Dim. in mm a 85.7 85.7 85.7 85.7 85.7 85.7
b 85.7 85.7 85.7 85.7 85.7 85.7 b 85.7 85.7 85.7 85.7 85.7 85.7
c 72 72 72 90 90 90 c 72 72 72 90 90 90
d 69.5 69.5 69.5 69.5 69.5 69.5 d 69.5 69.5 69.5 69.5 69.5 69.5
e 69.5 69.5 69.5 69.5 69.5 69.5
e 69.5 69.5 69.5 69.5 69.5 69.5
f 5.5 5.5 5.5 5.5 5.5 5.5
f 5.5 5.5 5.5 5.5 5.5 5.5
g. 11 11 11 11 11 11
g. 11 11 11 11 11 11
g.1 2 2 2 2 2 2
g.1 2 2 2 2 2 2 l 32 36 47 47 47 47
l 32 36 36 47 47 47 s 71 79 89 94 94 102
Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5 Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5
section (mm2) min.-max. —4 —4 —4 —10 —10 —10 section (mm2) min.-max. —4 —4 —4 —10 —10 —10

2 MB 203 2 MB 206
Drawing Amp. 16 32 Drawing Amp. 125
2 MB 203 Poles 7 7 2 MB 206 Poles 5
Dim. in mm a 85 85 Dim. in mm a 130
b 85 85 b 130
c 132 137 c 120
d 70 70 d 104
e 70 70 e 104
f 6.3 6.3 f 6.5
6 g.
g.1
11
2
11
2
g.
g.1
18
2
h 107 111 h 131
s 86 102 k 28
l 30 30 l 98
Terminal for cond. cross 1 2.5 Terminal for cond. cross 25
section (mm 2) min.-max. —2.5 —6 section (mm2) min.-max. —70

106 | MENNEKES www.MENNEKES.co.uk


Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

2 MB 212 2 MB 213
Drawing Drawing
2 MB 212 2 MB 213

Dim. in mm Dim. in mm

2 MB 221 5 MB 30
Drawing Amp. 16 32 Drawing
2 MB 221 Poles 4 5 3 4 5 5 MB 30 Typ 10186 / 10188 10189 10441 / 10442
Dim. in mm a 92.5 92.5 102 102 102 Dim. in mm a 460 460 460
b 87 87 94 94 94 b 260 260 180
c 150 228 148
c 84.5 84.5 94 94 94
d 434 434 440
d 55.5 55.5 62 62 62
e 234 234 160
e 76 76 84 84 84 f 11 11 8,1
f1 5.3 5.3 5.3 5.3 5.3 g 9 9 8
f2 5.3 5.3 5.3 5.3 5.3
h 128 128 146 146 146
i 21.5 21.5 26 26 26
M 25x1.5 25x1.5 25x1.5 25x1.5 32x1.5

5 MB 57 5 MB 59
Drawing Amp. 16 32 Drawing Amp. 16 32
5 MB 57 Poles 3 4 5 3 4 5 5 MB 59 Poles 3 4 5 3 4 5
Dim. in mm a 200 200 200 200 200 200 Dim. in mm a 200 200 200 200 200 200
b 110 110 110 110 110 110 b 110 110 110 110 110 110
c 47 50 51 59 59 60 c 46 49 46 56 56 53
d 190 190 190 190 190 190 d 190 190 190 190 190 190
e 100 100 100 100 100 100 e 100 100 100 100 100 100
f 5 5 5 5 5 5 f 5 5 5 5 5 5
g 13 13 13 13 13 13 g 13 13 13 13 13 13
k max. 56 56 56 56 56 56 k max. 56 56 56 56 56 56

6 MB 2 / 5 TE 6 MB 3 / 2 TE

Part no. 40243 / Draw. 6 MB 2 / 5 modules Part no. 40444 / Draw. 6 MB 3 / 2 modules Part no. 40871 / Draw. 6 MB 4 / 5 modules

6 MB 4 / 5 TE 6 MB 12 / 8 TE

thread holes
thread holes
thread holes for M4
for M4
for M4 center line
center line
center line

MB 3 / 2 modules Part no. 40871 / Draw. 6 MB 4 / 5 modules Part no. 40986ZA / Draw. 6 MB 17 / 6 modules Part no. 40979ZA / Draw. 6 MB 12 / 8 modules Part no. 40981ZE / Draw. 6 MB 13 / 12 modules

6 MB 13 / 12 TE 6 MB 14 / 12 TE

thread holes

6
hread holes for M4
thread holes

thread holes

or M4 center line
for M4
for M4

for M4

6 MB 12 / 8 modules Part no. 40981ZE / Draw.


Part no.1340985
6 MB / Draw. 6 MB 16 / 6 modules
/ 12 modules Part no. 40978 / Draw. 6 MB 15 / 8 modules Part no. 40980 / Draw. 6 MB 14 / 12 modules

MENNEKES | 107
Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

6 MB 15 / 8 TE 6 MB 16 / 6 TE
thread holes

thread holes

thread holes
for M4

for M4
for M4

for M4

for M4
MB 16 / 6 modules Part no. 40978 / Draw. 6 MB 15 / 8 modules Part no. 40980 / Draw. 6 MB 14 / 12 modules Part no. 40985 / Draw. 6 MB 16 / 6 modules Part no. 40978 / Draw. 6 MB 15 / 8 modules Part no. 40980 / Draw. 6 MB 14 / 12

6 MB 17 / 6 TE 6 MB 18
Drawing
6 MB 18

Number of
spacing modules 6 8 12
Dim. in mm b 115 150 222
thread holes e 105 140 212
thread holes
thread holes for M4
for M4
for M4 center line
center line
center line

Part no. 40986ZA / Draw. 6 MB 17 / 6 modules Part no. 40979ZA / Draw. 6 MB 12 / 8 modules Part no. 40981ZE / Draw. 6 MB 13 / 12 modules

108 | MENNEKES www.MENNEKES.co.uk


Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

AMAXX. Combination units.

AMAXX with 1 segment Depth dimensions of the AMAXX enclosures


with 1, 2, or 3 segments and various fittings.
Sockets IP-degrees Depth
SCHUKO® 16 A, 230 V IP44 175 mm
IP67 194 mm
CEE 16 A, 3 p, 230 V IP44 204 mm
IP67 205 mm
CEE 16 A, 5 p, 400 V IP44 209 mm
IP67 213 mm
1 MB 531 CEE 32 A, 5 p, 400 V IP44 221 mm
IP67 227 mm
CEE 63 A, 5 p, 400 V IP44 248 mm
IP67 248 mm
AMAXX with 2 segments

Cable entries: closed for cut out.

single enclosure 130 mm x 225 mm:


2 x M 25 on top and bottom
double enclosure 260 mm x 225 mm:
2 x M 32 on top and bottom
triple enclosure 390 mm x 225 mm:
2 x M 40 on top and bottom

1 MB 521 For all enclosures: 2 x M 20 on top and


bottom for cut out.

AMAXX with 3 segments

1 MB 522

AMAXX with 4 segments Depth dimensions of the AMAXX enclosures


with 4 or 5 segments and various fittings.

Sockets IP-degrees Depth


SCHUKO® 16 A, 230 V IP44 186 mm
IP67 208 mm
CEE 16 A, 3 p, 230 V IP44 216 mm
IP67 220 mm
CEE 16 A, 5 p, 400 V IP44 222 mm
IP67 226 mm
CEE 32 A, 5 p, 400 V IP44 231 mm
IP67 236 mm
CEE 63 A, 5 p, 400 V IP44 260 mm
6
1MB523 IP67 260 mm

MENNEKES | 109
Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

AMAXX. Combination units.


AMAXX with 5 segments Cable entries: closed for cut out.

quadruple enclosure 520 mm x 225 mm :


quintuple enclosure 650 mm x 225 mm :
2 x M 40 on top and bottom

For both enclosures: 2 x M 20 on top


and bottom for cut out.

1MB540

AMAXX s with 5 segments Depth dimensions of the AMAXX s enclosures


with 5 segments and various fittings.

Sockets IP-degrees Depth


SCHUKO® 16 A, 230 V IP44 140 mm
IP67 157 mm
CEE 16 A, 3 p, 230 V IP44 170 mm
IP67 169 mm
CEE 16 A, 5 p, 400 V IP44 172 mm
IP67 174 mm
CEE 32 A, 5 p, 400 V IP44 182 mm
IP67 188 mm

Cable entries: closed for cut out.


AMAXX s 650 mm x 112,5 mm:
1 x M 25 each on top and bottom or
1 x M 32 each on top and bottom
Additionally: 1 x M 20 each on top and
1MB541
bottom to cut out.

110 | MENNEKES www.MENNEKES.co.uk


Service – Drawings and dimensions
The sizes for the entries on the drawings can be different to the real existing entry sizes. Subject to modification and amendments without prior
notice. Errors and omissions excepted.

3 MB 44
3 MB 44
Cable entry: 1 x with gland diameter,
Pos. Receptacles IP-degrees Dim. Ø 17 mm or 27 mm
a 114.0 mm
a1 SCHUKO®, 16 A, 230 V IP 44 max. 30.0 mm
a1 CEE 16 A, 3 p, 230 V IP 44 52.7 mm
a1 CEE 16 A, 5 p, 400 V IP 44 50.5 mm
a1 CEE 32 A, 5 p, 400 V IP 44 64.0 mm
a2 30.0 mm
b 160.0 mm
b1 SCHUKO®, 16 A, 230 V IP 44 max. 18.0 mm
b1 CEE 16 A, 3 p, 230 V IP 44 42.0 mm
b1 CEE 16 A, 5 p, 400 V IP 44 40.0 mm
b1 CEE 32 A, 5 p, 400 V IP 44 53.2 mm
c 133.0 mm
d 97.0 mm
y 17.0 mm

3 MB 45
3 MB 45 Cable entry: 1 x with gland diameter,
Pos.
a
Receptacles IP-degrees Dim.
114.0 mm
Ø 17 mm or 27 mm
a1 SCHUKO®, 16 A, 230 V IP 68 35.0 mm
a1 CEE 16 A, 3 p, 230 V IP 67 56.3 mm
a1 CEE 16 A, 5 p, 400 V IP 67 59.0 mm
a2 30.0 mm
b 160.0 mm
b1 SCHUKO®, 16 A, 230 V IP 44 24.0 mm
b1 CEE 16 A, 3 p, 230 V IP 44 44.3 mm
b1 CEE 16 A, 5 p, 400 V IP 44 47.0 mm
c 133.0 mm
d 97.0 mm
y 17.0 mm

5 MB 35
Drawing Enclosure size: 401 x 97 mm
5 MB 35 Cable entry: 1 x M 20 plugged at the top‚
Dim. in mm a 401
b 97
1 x M 20 with gland at the bottom
c 63
d 364
e 56
f 5.5
g. 4
M 25
M* 25

5 MB 44
Drawing Enclosure size: 445 x 135 mm
5 MB 44

Dim. in mm

max. installation depth

5 MB 48a
Drawing Enclosure size: 300 x 230 x 287.5 mm
5 MB 48a

Dim. in mm

1 MB 517 1 MB 518

254 415 Drawing


1 MB 518

Blind Dim. in mm
plug
M 20
Earthing
1043

stud
M8
250.5
180 6
390,9

5
01
250
170

for part no. for part no.


320 B-B
15678 and 15679 245.5 15680 and 15681

MENNEKES | 111
Service – Index of part numbers
Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page
31 16 250 33 348 35 524 40 675A 73 838 36 1217 35
32 16 251 33 349 35 525 40 676A 73 839 36 1247A 23
100 14 253 33 352 35 527 40 677A 73 840 36 1248A 23
101 14 254 33 353 35 528 40 707A 73 843 35 1249A 23
102 14 255 33 354 35 529 40 708A 73 844 35 1252A 23
103 14 259 33 355 35 530 40 713A 73 846 35 1260A 23
104 14 261 33 356 35 531 40 714A 73 847 35 1261A 23
105 14 262 33 357 35 539 41 715A 73 851 87 1263A 24
106 14 263 33 358 35 540 41 716A 73 852 87 1264A 24
107 14 265 33 359 35 541 41 720A 73 853 36 1265A 24
109 14 266 33 360 35 542 41 721A 73 855 39 1270 72
110 14 267 33 361 35 543 41 726A 73 856 14 1271 72
111 14 277 34 362 35 544 41 727A 73 857 23 1272 72
128A 14 278 34 363 35 545 41 728A 73 858 23 1273 72
129A 14 279 34 364 35 546 41 729A 73 891 34 1340 16
130A 14 280 34 365 35 548 41 733 67 903 24 1341 16,87
131A 14 281 34 367 35 549 41 734 67 905 24 1342 16
132A 14 282 34 368 35 550 41 735 67 913 39 1343 16
133A 14 283 34 371 37 551 41 736 67 921 35 1344 16
134A 14 284 34 372 37 552 41 737 67 922 35 1345 16
135A 14 285 34 373 37 553 41 738 67 1035 67 1346 16
136A 14 286 34 379 37 554 41 739 67 1040 67 1347 16
137 15 287 34 380 37 555 41 740 67 1045 67 1348 16
138 15 288 34 381 37 556 41 741 67 1050 67 1349 16
139 15 289 34 383 37 557 41 742 67 1055 67 1365 23
140 15 290 34 384 37 558 41 743 67 1060 67 1366 23
142 15 291 34 385 37 560 41 744 67 1065 68 1367 23
143 15 292 34 386 37 561 41 745 68 1070 68 1384 23
203A 24 293 34 390 37 562 41 746 68 1075 68 1385 23
204A 24 294 34 391 37 577 71 747 68 1080 68 1386 23
205A 24 295 34 392 37 578 71 748 68 1081 24 1388 23
206A 24 296 34 393 37 583 71 749 68 1082 24 1389 23
207A 24 297 34 394 37 584 71 750 68 1103 24 1390 23
208A 24 298 34 395 37 585 71 751 68 1107 35 1391 23
209A 24 299 34 396 38 586 71 752 68 1123A 24 1392 23
211A 24 300 34 397 38 590 71 800 35 1124A 24 1393 23
212A 24 315 34 398 37 591 71 801 35 1125A 24 1394 23
213A 24 318 38 399 37 596 71 802 35 1127A 24 1395 23
215A 24 319 38 400 37 597 71 803 35 1128A 24 1396 23
216A 24 321 38 401 37 598 71 804 35 1131 26 1398 23
217A 24 322 38 402 37 599 71 812 36 1136A 14 1399 23
218A 24 325 38 403 37 603 72 813 36 1137A 14 1400 23
219A 24 327 38 405 37 604 72 814 36 1140A 14 1401 23
221A 24 328 38 406 37 609 72 815 36 1141A 14 1402 23
222A 24 329 39 407 37 610 72 817 36 1142A 14 1408 36
223A 24 330 39 410 37 611 72 819 36 1144A 14 1409 36
224A 24 331 35 411 37 612 72 820 36 1145A 14 1410 34
226A 24 332 35 412 37 616 72 821 36 1146A 23 1411 34
227A 24 333 35 418 16 617 72 824 36 1147A 23 1414 37
228A 24 334 35 419 16 622 72 825 36 1148A 23 1415 37
229A 24 335 35 420 16 623 72 826 36 1149A 23 1418 14
230A 24 336 35 421 16 624 72 827 36 1150A 23 1419 14
231A 24 337 35 422 16 625 72 828 36 1151A 23 1420 14
232A 24 338 38 509 40 655A 73 829 36 1152A 23 1421 14
233A 24 339 38 511 40 656A 73 830 36 1153A 23 1422 14
234A 24 340 35 512 40 661A 73 831 36 1154A 23 1423 14
235A 24 341 35 513 40 662A 73 832 36 1155A 23 1424 14
236A 24 342 35 515 40 663A 73 833 36 1168 26 1425 14

6 239A 24 343 35 516 40 664A 73 834 36 1169 26 1426 14


240A 24 344 35 517 40 668A 73 835 36 1171 26 1427 14
247 33 345 35 521 40 669A 73 836 36 1173 26 1428 14
249 33 347 35 523 40 674A 73 837 36 1216 35 1436 37

112 | MENNEKES www.MENNEKES.co.uk


Service – Index of part numbers
Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page
1437 37 1633 25 1740 25 1858 16 2478 39 3187 23 3657 36
1438 40,87 1635 25 1741 25 1859 16 2488A 72 3188 23 3658 36
1455 24 1637 25 1742 25 1860 16 2493 40 3189 23 3665 36
1456 24 1638 25 1743 25 1861 16 2495 40 3190 23 3704 36
1457 24 1639 25 1744 25 1862 16 2511 39 3191 23 3718 82
1458 24 1640 25 1745 25 1864 16 2517 40 3192 23 3773 15
1460 24 1641 25 1746 25 1955 73 2617A 72 3193 23 3774 15
1461 24 1642 25 1747 25 1959 73 2668 35 3197 24 3775 67
1462 23 1643 25 1749 25 1961 73 2674 40 3200 24 3776 68
1463 23 1644 25 1750 16 1962 73 2692 83 3201 23 3777 68
1464 23 1646 25 1751 16 1965 73 2837 72 3202 23 3778 41
1465 23 1649 16 1752 16 1967 73 2841 72 3231 37 3783 68
1466 23 1650 16 1753 16 1968 73 2845 72 3232 37 3784 68
1467 23 1651 16 1754 16 1972 73 2852 72 3254 24 3794 34
1468 23 1657 72 1755 16 1974 73 2855 72 3256 24 3796 34
1469 23 1661 72 1756 16 1975 73 2860 72 3266 34 3799 34
1470 23 1667 25 1757 16 1978 73 2864 72 3283 24 3807 34
1471 23 1668 25 1786 25 1980 73 2869 72 3290 72 3809 34
1472 23 1669 25 1787 25 1981 36 2870 72 3306 34 3810 34
1473 23 1671 25 1788 25 1982 36 2883 67 3312 34 3811 34
1474 24 1672 25 1790 25 1983 36 3004 25 3331 16 3819 34
1475 24 1673 25 1791 25 1984 36 3008 25 3338 38 3821 34
1476 24 1674 25 1792 25 2000 14 3028 14 3339 38 3823 34
1477 24 1675 25 1793 25 2007A 14 3030 14 3340 38 3829 34
1478 24 1676 25 1794 25 2015 33 3031 23 3341 38 3830 34
1479 24 1677 25 1795 25 2123A 82 3032 14 3342 39 3832 34
1480 24 1678 25 1796 25 2139 15 3034 14 3343 39 3841 34
1481 24 1679 25 1797 25 2166 68 3035 14 3345 39 3842 34
1484 24 1680 25 1798 25 2167 68 3036 23 3346 39 3844 34
1485 24 1682 25 1800 25 2168 33 3039 14 3347 39 3851 34
1486 23 1688 36 1801 26 2169 14 3043 14 3368 39 3853 34
1487 23 1693 72 1802 26 2175B 82 3045 14 3380 24 3855 34
1490 24 1700 26 1803 26 2177A 83 3046 14 3385 25 3859 41
1491 23 1701 26 1804 26 2178 33 3048 25 3413 36 3860 41
1492 23 1702 26 1805 26 2179A 24 3049 25 3420 37 3862 41
1493 23 1703 26 1806 26 2180A 24 3054 23 3424 34 3871 41
1494 23 1704 26 1808 26 2181A 24 3055 23 3447 23 3872 41
1495 23 1705 26 1809 26 2189 33 3057 23 3449 23 3873 41
1496 23 1706 26 1810 26 2193 40 3059 23 3451 23 3879 41
1497 23 1707 26 1813 26 2195 33 3060 23 3452 23 3881 41
1498 23 1708 26 1814 26 2196 40 3070 25 3454 23 3883 41
1499 23 1709 26 1815 26 2199 14 3072 23 3455 23 3887 41
1500 23 1710 26 1818 26 2212 67 3074 23 3458 37 3888 41
1501 24 1711 26 1819 26 2213 68 3093 23 3459 37 3891 41
1502 24 1712 26 1820 26 2241 14 3110 23 3460 37 3897 41
1503 24 1713 26 1823 72 2243 33 3112 23 3461 37 3898 41
1504 24 1714 26 1825 71 2244 33 3114 23 3473 25 3899 41
1505 24 1716 26 1829 71 2245 40 3124 25 3485 26 3907 41
1506 24 1717 26 1831 71 2255 68 3126 25 3507 24 3909 41
1507 24 1719 16 1832 71 2271 33 3134 14 3524 24 3913 68
1551 24 1720 16 1835 71 2296 67 3136 23 3527 37 3914 68
1555 14 1721 16 1837 71 2317 67 3139 14 3528 37 3915 68
1556 14 1723 16 1838 71 2324 68 3140 23 3566 26 3916 68
1557 14 1724 16 1842 71 2341 33 3141 14 3573 26 3917 37
1579 72 1725 16 1844 71 2359 35 3149 14 3575 24 3980 34
1594 72 1727 16 1845 71 2386 35 3152 14 3581 26 3981 34
1602 72 1730 16 1848 71 2400 35 3153 23 3583 36 3982 34
1603 72 1733 25 1850 71 2405 68 3154 14 3587 26 3983 34
1618 25 1734 25 1851 16 2406 68 3155 25 3590 26 3987 34
6
1619 25 1735 25 1852 16 2441 40 3157 25 3600 36 3999 41
1631 25 1737 25 1856 16 2459 67 3171 25 3646 34 4101 22
1632 25 1739 25 1857 16 2460 68 3186 23 3656 36 4102 22

MENNEKES | 113
Service – Index of part numbers
Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page Part no. Page
4103 22 5111A 17 7516 27 9323 14 11181 63 13519 33 14519 40
4104 22 5112A 17 7520 27 9341 14 11182 63 13520 33 14520 40
4105 22 5113A 17 7521 27 9342 14 11310 63 13521 33 14561 41
4106 22 5690A 18 7523 27 9350 14 11311 63 13522 33 14562 41
4107 22 5691A 18 7524 27 9351 14 11312 63 13523 33 14563 41
4108 22 5692A 18 7525 27 9352 14 11313 63 13561 34 14565 41
4110 22 5692AM 21 7526 27 9370 14 11330 63 13562 34 14567 41
4111 22 5759A 17 7530 27 9371 14 11331 63 13563 34 14582 41
4112 22 5887A 18 7531 27 9372 14 11332 63 13564 34 14584 41
4113 22 5888A 18 7534 27 9373 14 11333 63 13565 34 14585 41
4114 22 5911A 17 7535 27 9380 14 11511 63 13567 34 14586 41
4115 22 5925A 17 7536 27 9381 14 11512 63 13582 34 14587 41
4116 22 5946A 82 7602 17 9382 14 11531 63 13583 34 14597 70
4117 22 5955A 17 7603 17 9530 67 11532 63 13584 34 14599 69
4118 22 5956A 17 7604 17 9531 67 11561 63 13585 34 14601 74
4119 22 5957A 17 7605 17 9532 67 11581 63 13586 34 14609 70
4120 22 5959A 17 7607 17 9562 82 11611 64 13587 34 15678 61
4122 22 6571 17 7612 17 9590 67 11661 64 13597 70 15679 61
4123 22 7000 18 7613 17 9591 67 11681 64 13599 69 15680 61
4125 22 7123 19 7614 17 9592 67 13101 33 13601 74 15681 61
4127 22 7125 19 7616 17 10081 63 13102 33 13609 70 15696 52
4128 22 7126 19 7620 18 10082 63 13105 33 13610 69 15738 61
4130 22 7127 19 7621 18 10083 63 13106 33 13613 74 15739 61
4132 22 7148 19 7624 18 10087 64 13107 33 14101 40 15740 61
4133 22 7150 19 7625 18 10092 63 13111 33 14102 40 15741 61
4135 22 7152 19 7626 18 10713 64 13112 33 14105 40 17002 65
4137 22 7245UK 21 7628 18 10718 64 13201 34 14106 40 17006 65
4138 22 7246UK 21 7629 18 10749 64 13202 34 14107 40 17014 65
4140 22 7247UK 21 7633 18 10751 64 13203 34 14111 40 18430 54
4204 22 7248UK 21 7634 18 10754 64 13204 34 14112 40 18431 54
4219 22 7249UK 21 7635 18 10755 64 13205 34 14201 41 18444 54
4220 22 7250 21 7636 18 10828 65 13206 34 14202 41 20458 85
4224 22 7251 21 8001 87 10833 65 13207 34 14203 41 20459 85
4226 22 7252 21 8008 87 10837 64 13208 34 14204 41 20460 85
4233 22 7253 21 9104 16 10838 64 13209 34 14205 41 20461 86
4254 22 7254UK 21 9105 16 10839 64 13210 34 14206 41 20462 86
4300 77 7255 21 9106 16 10840 64 13211 34 14207 41 20463 86
4302 77 7256UK 21 9120 16 10841 64 13212 34 14208 41 22189A 85
4304 77 7257 21 9121 16 10842 64 13213 34 14209 41 22928 85
4320 77 7258 21 9122 16 10843 64 13214 34 14210 41 23163 85
4322 77 7260 21 9123 16 10844 64 13215 34 14211 41 23165 85
4324 77 7289 18 9124 16 10845 64 13216 34 14212 41 23175 85
4326 77 7290 18 9125 16 10846 64 13217 34 14213 41 23176 85
4340 77 7291ZA 19 9140 16 10863 65 13218 34 14214 41 23177 85
4342 77 7292 19 9141 16 11010 63 13219 34 14215 41 23249 86
4344 77 7294 19 9142 16 11011 63 13220 34 14216 41 23293A 85
4345 77 7295 19 9150 16 11012 63 13223 34 14217 41 23432 85
4350 77 7296 19 9151 16 11013 63 13224 34 14218 41 23433 86
4352 77 7306 67 9152 16 11030 63 13225 34 14219 41 24210 86
4354 77 7307 67 9171 16 11031 63 13226 34 14220 41 24630 85
4360 77 7312 19 9172 16 11032 63 13227 34 14223 41 24640 85
4362 77 7313 19 9173 16 11033 63 13236 69 14224 41 24643 85
4364 77 7393UK 21 9174 16 11060 63 13237 69 14225 41 24660 86
4367 77 7394 19 9180 16 11061 63 13238 69 14226 41 24670 86
4370 77 7434 21 9181 16 11081 63 13239 69 14227 41 24671 86
4372 77 7469 19 9182 16 11110 63 13502 33,87 14502 40,87 24672 86
4374 77 7470UK 21 9300 14 11111 63 13506 33 14506 40 24675 86
4375 77 7502 27 9301 14 11131 63 13509 33 14509 40 24685 86

6 4377 77 7503 27 9302 14 11160 63 13510 33 14510 40 24686 86


4378 77 7505 27 9320 14 11161 63 13511 33 14511 40 24687 86
5109A 17 7507 27 9321 14 11162 63 13513 33 14513 40 24730 85
5110A 17 7512 27 9322 14 11180 63 13516 33 14516 40 24740 85

114 | MENNEKES www.MENNEKES.co.uk


Service – Index of part numbers
Part no. Page Part no. Page Part no. Page
24760 86 52241 88 941137 49
24770 86 52242 88 941142 53
24772 86 52243 88 960043 48
24773 86 52244 88 990606 52
24775 86 52245 88 990607 52
24785 86 52246 88 990608 52
24787 86 70029 59 990609 52
24788 86 90839 55 990610 52
24840 85 92658 55 990611 52
24870 86 92893 55 990612 52
24873 86 92917 55 990620 52
24885 86 95472 57 990623 52
24888 86 96227 57 990625 52
24970 86 96489 57 990627 52
24973 86 96703 57 5601304G 17
24985 86 900946 51 5601306G 17
24988 86 910214 47 5601406G 17
25042 79 910244 20 5601407G 17
25056 79 910245 20 5601409G 17
25102 76 910253 19 5601506G 17
25102GE 76 910355 50 5601507G 17
25405 80 910394 47 5602304G 17
27001 14 910584 20 5602306G 17
27002 14 920278 20 5602406G 17
27003 14 920286 47 5602506G 17
27004 14 920464 48 5603304G 17
27005 14 920649 20,50 5603306G 17
27006 14 920666 21 5603404G 17
27007 14 920668 21 5603406G 17
27008 14 920670 21 5603407G 17
40243 89 920700 20,50 5603409G 17
40444 89 920714 50 5603506G 17
40744 87 920791 20 5603507G 17
40778 38 920821 20,53 5603509G 17
40784 38 920838 20 5604304G 17
40785 38 920845 20 5604306G 17
40786 38 920851 49 5604406G 17
40787 38 920860 20,48 5604407G 17
40788 38 920863 20 5604409G 17
40841 38,83 920958 19 5604506G 17
40871 89 920961 19 5604509G 17
40978 89 920962 19 5704403G 82
40978ZA 89 921015 47 5802306G 17
40979 89 921024 53 5802406G 17
40980 89 921160 20 5802506G 17
40980ZC 89 921380 20 5804306G 17
40981 89 921442 20 5804406G 17
40985 89 922218 20 5804506G 17
40985ZB 89 922452 20 7420224 59
40986 89 922453 20 8063261 56
41000 24,26 922517 20 8067864 56
41342 83 922518 20 15452000 41
41416 38 922519 20 15453000 41
41431 89 923275 20
41432 89 923276 20
41433 89 923297 20
41452 79 931227 48
41455 79 931234 49
41457 79 931539 20
6
41482 35 932285 20
41489 35 934285 20
41492 79 940027 84

MENNEKES | 115
MENNEKES
Electric Ltd.

Unit 4, Crayfields Industrial Park


Main Road, St. Pauls Cray
Orpington, KENT
BR5 3HP, UK

Phone +44 1689 833522


Fax +44 1689 833378
sales@MENNEKES.co.uk

www.MENNEKES.co.uk

Headquarters:
MENNEKES
Elektrotechnik GmbH & Co. KG
1050700DS 1TA 07.23 K
Aloys-Mennekes-Straße 1
57399 KIRCHHUNDEM Subject to change without notice.
GERMANY No liability accepted for printing
errors.
Phone +49 2723 41-1
Fax +49 2723 41-214
info@MENNEKES.de

www.MENNEKES.com

You might also like