INLET DIFFUSER CALCULATION

Document Number Rev. : 0


STORAGE TANK T-110 Document Number
SKH-TTA-CAL-10-008-A4
3 dari 3

0.813 m
Q1 Q2
0.4064 m
v1 v2

Inlet Flowrate

Q1 = 1700 m3/h (Flowrate SPM 3)

Dia nozzle = 0.4064 m

A1 = 0.129651354 m2

Inlet Velocity
Q1
v1 =
A1

v1 = 13112.08833 m/h
= 11.94656936 ft/sec

When,
Q1 = Inlet Flowrate
A1 = Cross Area inlet nozzle
v1 = Inlet velocity

Flowrate out diffuser

Q2 = 1700 m3/h (From SPM 3)

Dia difuser = 0.813 m

A2 = 0.518860665 m2

Velocity out diffuser


Q2
v2 =
A2

v2 = 3276.409477 m/h
= 2.985173079 ft/sec

When,
Q2 = Flowrate out diffuser
A2 = Cross Area out diffuser
v2 = Velocity out diffuser

Limit exit velocity as per API 650 clause 5.8.11.2, to 3 ft/sec