f$ I 2720 ( Part III/k i ) - 1980

( Reaffirmed 2002 )

Indian Standard
METHODS OF TEST FOR SOILS
PART III DETERMINATION OF SPECIFIC GRAVITY

Section 1 Fine Grained Soils

( First Revision )

First Reprint APRIL 1989

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
UDC 624.131.431.1

@ Copyright 1980

BUREAU OF INDIAN STANDARDS


hlANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002

Gr 2 Decernhrr 1YSO
t8:2720(hdIl/Secl)-h80

Indian Standard
METHODS OF TEST FOR SOILS
PART III DETERMINATION OF SPECIFIC GRAVITY

Section 1 Fine Gralned Soils

( First Revision)

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
Soil Engineering and Rock Mechanics Sectional Committee, BDC 23

Chainnan Repremlfing
DB JAODIBHNAMIN University of Roorkee, Roorkee

ADDITIONAL DIBIOTOB, IRI Irrigation Department, Government of Bihar,


Patna
ADDITIONAL DI~WTO~ REEEABOE Ministry of Railways
( F. E. ), RDSO
DEPUTY DIREOTO~ ~~E~BOR
PBor ~;-B&H 1, RDSO ( Alh+ 1
Unlve-rsity of Jodhpur, Jodhpur
CAL AVTA~ SINGE Engineer-in-Chief’s Branch, Army Headquarters
LT-COL V. K. KANITXAB ( Ahnuts )
Da A. BANERJEE Cemindia Co Ltd, Bombay
SHRI S. GUPTA ( Ahmale )
DR R. K. BHANDARI Central Building Research Instittite, Roorkea
CHIEF ENWNEEB ( B&R ) Irrigation Department, Government of Punjab,
Chandigarh
Da G. S. Dhillon ( AlternaIe )
SHRI M. G. DANDAVATB The Concrete Association of India, Bombay
SHBI N. C. DUWUL ( Ahnuts )
SERI A. G. DASTIDAB In personal capacitv (5 H&I rr ad Courr, 12/l
Hunbwfwd Strut, Colcut~aRX&/,
DR G. S. DHILLON Indian eotechnical Society, New Delhi
DIREOTOR, IRI Irrigation Department, Government of Uttar
Pradesh, Roorkee

@ Cow+ 1980
BUREAU OF INDIAN STANDARDS
This publication is protected under the Indian Cobrig& Act ( XIV of 1957 ) and
reproduction in whole or in part by any means except with written permission of the
publisher shall be deemed to be an infringement of copyright under the said Act.
IS 8 2720 ( Part III/Set 1) - 1980

( Contiwdfrom pa&y 1)

Mambers Rqmwnting
SERI A. H. DIVANJI Asia Foundations & Construction (P) Ltd,
Bombay
SHRI A. N. JANQLE ( Ahmate )
Pnos GOPALRANJAN University of Roorkee, Roorkee
Pnov GOPAL RANJAN Institution of Engineers ( India ), Calcutta
Da SHASHI K. GULAATI Indian Institute of Technology, New Delhi
DR G. B. RAO ( Altcrnntc )
San1 0. P. MALHOTBA Public Works Department, Chandigarh Adminis-
tration, Chandigarh
SERI T. K. NATBAJAN Central Road Research Institute, New Delhi
PRESIDENT( IMDA ) All India Instrument Manufacturers & Dealers
Association, Bombay

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


DEPUTY SECRETARY( AIIMDA ) ( Altcrnatc )

for internal use by subscribing member only.


SH~I R. V. RANTHIDEVAN Central Water Commission, New Delhi
DEPUTY DIRECTOR( CSMRS ) ( Ahmate 1
RE&AI~CH OBBICER( B&RRL ) Public Works Department, Government of Punjab,
Chandiqarh
SHRI K. R. SAXENA Public Works Department, Government of Andhra
Pradesh, Hyderabad
SECRETARY Central Board of Irrigation & Power, New Delhi
DEPUTY SECRETARY( Ahmate )
SHBI N. SIVAQURU Roads Wing, Ministry of Shipping 8t Transport
SHRI D. V. SlxxA (Altmats)
SH~I K. S. SRINIVASAN National Buildings Organization, New Delhi
SHRI SUNIL BEHRY ( Aftmats )
SUPERINTENDINGE N Q I N E E R Public Works Department, Government of Tamil
(P&D) Nadu, Madras
EXECUTIVEENGINEER( SMRD ) ( Alternate )
SHRI H. C. VEBMA All India Instrument Manufacturers & Dealers
Association, Bombay
SHBI H. K. GUIZIA ( Altmuk)
Ssar S. D. VIDYARTHI Public Works Department, Government of Uttar
Pradesh, Lucknow
DR B. L. DHAWAN ( Al&ma& )
SBRI G. RAYAN, Director General, IS1 ( J&-o@& Muakr )
Director (Civ Engg )

SEEI K. M. MATHW
Deputy Director ( Civ Engg ), IS1

(Conh’wdonpogr8)
IS I 2720 ( Part III/&x 1) - 1980

Indian Standard
METHODS OF TEST FOR SOILS
PART III DETERMINATION OF SPECIFIC GRAVITY

Section 1 Fine Grained Soils

( First Revision)

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
0. FOREWORD
0.1 This Indian Standard ( Part III/Set 1 ) ( First Revision ) was adopted
by the Indian Standards Institution on 3 October 1980, after the’ draft
finalized by the Soil and Rock Mechanics Sectional Committee had been
approved by the Civil Engineering Division Council.

0.2 With a view to establishing uniform procedures for the determination


of different characteristics of soils and also for facilitating a comparative
study of the results, the Indian Standards Institution is bringing out a
series of standards on methods of test for soils ( IS : 2720 ). This standard
( Part III ) deals with the method of test for determination of specific
gravity of soils which finds application in finding out the degree of
saturation and unit weight of moist soils. The unit weights are needed
in pressure, settlement and stability problems in soil engineering. This
standard was published in the year 1964. In view of the further work done
in this field in this, as well as in other countries, the revision has been pre-
pared so as to give the latest method of test which has separate provision
for fine grained and coarse soils. The revision is being prepared in two
sections : Section 1, dealing with the method for fine grained soil which is
a basically laboratory method and Section 2 for fine, medium and coarse
grained soils which is field method.

0.3 In reporting the result of a test or analysis made in accordance with


this standard, if the final value, observed or calculated, is to be rounded
off, it shall be done in accordance with IS : 2-1960*.

*Rules for rounding off numerical values ( r&red).

3
IS I 2720 ( Part III/kc 1) - 1980

1. SCOPE
1.1 This standard ( Part III/Set 1 ) lays down the methods of test for the
determination of the ,specific gravity of soil particle of fine grained soils
( see Note ) .
NOTE - The method may also he used for medium and coarse grained soils if
the coarse parttcles are grained to pass 4*75-mm IS sieve before using.
2. TERMINOLOGY
2.1 For the purpose of this standard, the definition of terms given
in IS : 2809-1972* shall apply.
3. APPARATUS
3.1 The following apparatus is required:
4 Two density bottles ( pyknometers ) of approximately 50 ml
capacity with stoppers.
b) A water-bath maintained at a constant temperature to within

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
f 02°C. ( If standard density bottles are used this constant tem-
perature is 27°C. )
Cl A vacuum desiccator ( a convenient size is one about 200 mm to
250 mm in diameter ).
4 A desiccator ( a convenient size is one about 200 mm to 250 mm
in diameter ) containing anhydrous silica gel.
4 A thermostatically controlled drying oven, capable of maintain-
ing a temperature of 105 to 110°C.
f 1 A balance readable and accurate to O*OOl g.
.!a A source of vacuum, such as a good filter pump or a vacuum
pump.
4 A spatula ( a convenient size is one having a blade 150 mm long
and 3 mm wide; the blade has to be small enough to go through
the neck of the density bottle ), or a piece of glass rod about
150 mm long and 3 mm diameter.
j) A wash bottle, preferably made of plastics, containing air-free
distilled water ( see Note ).
k) A sample divider of the multiple slot type ( S%le box ) with 7 mm
width of opening.
“1 A length of rubber tubing to fit the vacuum pump and the
desiccator.
NOTE - Obtain the air-free distilled water for at least 30 minute in a container
that can be sealed from the atmosphere during cooling. Take care to see that the
container is strong enough to resist the reduction in pressure inside it during
cooling.

*Glossary of terms and symbols relating to soil engineering .( JirJl n&ion ).

?
1s I 2720 ( Part III/Set 1 ) - 1980

4. PROCEDURE
4.1 The complete density bottle with stopper, shall be dried at 105 to
1 lO”C, cooled in the desiccator and weighed to the nearest 0.001 g ( ml )
( Je Note 1 ).
4.2 The 50 g sample obtained as described in the procedure for the pre-
paration of-disturbed samples for testing ( see 1.5 ) shall if necessary be
ground to pass a 2-mm IS test sieve. A 5 to 10 g subsample shall be
obtained by riffling, and oven dried at 105 to 110°C ( see Note 2 ). This
sample shall be transferred to the density bottle direct from the desiccator
in which it has been cooled. The bottle and contents together with the
stopper shall be weighed to the nearest 0.001 g ( ma).
4.3 Sufficient air-free distilled water ( see Note 3 ) shall be added so that
the soil in the bottle is just covered. The bottle containing the soil and

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
liquid, but without the stopper, shall be placed in the vacuum desiccator,
which shall then be evacuated gradually. The pressure shall be reduced
to about 20 mmHg. When using a water pump, because of variation in
mains pressure, care shall be taken to ensure that the required vacuum is
maintained. Care shall be taken during this operation to see that the air
trapped in the soil does not bubble too violently, so as to prevent small
drops of the suspension being lost through the mouth of the bottle. The
bottle shall be allowed to remain in the desiccator for at least 1 hour until
no further loss of air is apparent.

4.4 The vacuum shall be released and the lid of the desiccator removed.
The soil in the bottle shall be stirred carefully with the spatula, or
the bottle vibrated. Before removing the spatula from the bottle the
particles of soil adhering to the blade shall be washed off with a few drops
of air-free liquid. The lid of the desiccator shall then be replaced and the
desiccator evacuaied again.
4.5 The procedure outlined in 4.3 and 4.4 shall be repeated until no more
air is evolved from the soil ( see Note 4 ).
4.5.1 Alternately, the entrapped air can be removed by getting heat-
ing the pyknometer placed on a water-bath or sand-bath.
4.6 The bottle and cohtents shall then be removed from the desiccator
and further air-free liquid added until the bottle is full. The stopper shall
then be inserted. The stoppered bottle shall be immersed up to the neck
in the constant-temperature bath for approximately 1 hour or until it has
attained the constant temperature of the bath ( see Note 5 ).
If there is an apparent decrease in volume of the liquid the stopper
shall be removed and further liquid added to fill the bottle and the
stopper.replaced. The bottle shall then be returned to the bath and sufi-
cient time shall be allowed to elapse after this operation to ensure that the

5
IS : 2720 ( Part III/SW 1 ) - 1980

bottle and its contents again attain the constant temperature of the bath.
If the bottle is still not completely full this process shall be repeated.
4.7 The stoppered bottle shall then be taken out of the bath, wiped dry
and the whole weighed to the nearest O*OOlg (ma).
4.8 The bottle shall then be cleaned out and filled completely with air-
free liquid, the stopper inserted and then the whole immersed in the
constant temperature bath for 1 hour or until it has attained the constant
temperature of the bath. If there is an apparent decrease in the volume
of the liquid, the stopper shall be removed and further liquid added to
fill the bottle and the stopper replaced. The stoppered bottle shall then
be returned to the batch and sufficient time shall be allowed to elapse
after this operation to ensure that the bottle and its contents again attain
the constant temperature. If the bottle is still not completely full this
process shall be repeated. The bottle shall then be taken out of the bath,
wiped dry and the whole weighed to the nearest OS001 g (md)

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
( see Note 6 ).
4.9 Two determinations of the specific gravity of the same soils sample
shall be made ( see Notes 7 and 8 ).
NOTE 1 - S!andord Density Bolllcr - If a density bottle is used then in order to
avoid distortion it should not bc dried by placing it in an oven. It may be dried by
rinsing with acetone or an alcohol-ether mixture and then blowing warm air
through it.
NOTE 2 - Oven drying of the soil has been specified for convenience. If there
is any reason to believe that this will change the specific gravity due to loss of water
of hydration the soil should be dried at not more than 80°C. This fact should be
rep&ted.
NOTR 3 - Alternative Liquidsfor .Speci/icGrad/y Defcrminufion- With certain soils,
for c*x;~rnpl~~those containing 5oluble salts, kerosene ( paraffin oil ) or white spirit
may 1)~ prcft*rrt*(l. If one of these is used, record the fact and carry ollt a separate
oxp(arinlcn! to d<,tc:rmine the specific gravity of the liquid at the room tempt*rature
of the! tt,st. ‘I’hc equation for the specific gravity of the soil particles, G. given in 5.1
thcan becomes:

where

CL = specific gravity of the liquid used, at the constant temperature;


m, = mass of density bottle in g;
ms = mass of bottle and dry soil in g;
m3 = mass of bottle, soil and liquid in g; and
mg = mass of bottle when f@ll of liquid only in g.
Nom 4- Experience has shown that the largest source of ‘error in the test is
due to the diflicllltv in ensurine the comnlete removal of air from the sample.
I
To
obtain reliable results the soil should be left under vacuum for scvrral hours, pre-
ferably overnight. Shaking the ‘bottle in hand once or twice intcruppting the
vacuum gives quicker results.

6
fS : 2720 ( Part IfI/&c 1 ) - 1930

NOTE 5 - If a constant temperature room or cabinet is available then thir PIO=


cedure need not be carried out in a water-bath.
NOTE 6 - If method given in 4.8 is used to find the volume of the density
bottle then the test may be carried out at any temperature provided it is constant
throughout the test.
NOTE 7 - Many soils have a substantial proportion of heavier or lighter parti-
cles. Such soils will give erratic values for the specific gravity even with the
greatest care in testing and a number of repeated tests may be needed to obtain
a good average value.
NOTE 8 - Clean quartz and flint sands generally have a specific gravity close to
2.65; low values would suggest the presence of organic matter.

5. CALCULATION
5.1 The specific gravity of the soil particles G shall be measured at ioom

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


temperature If water has been psed as the air-free liquid, then the

for internal use by subscribing member only.


following equation shall be used:
ms - ml
G-
(m4-ml) - (m8-4 ?.
where
ml = mass of density bottle in g;
ms =i mass of bottle and dry soil in g;
ms - mass of bottle, soil and water in g; and
m, = mass of bottle when. full of water only in g.
If some other air-free liquid has been used reference should be made
to Note 3.
5.2 The specific gravity shall be calculated at 27OC. If the room tempe
rature is different than 27”C, the following correction shall be done:
G’ -KG
where
G’ - Corrected specific gravity at 27OC, and
Relative density of water at room temperature
x
= Relative density of water at 27%.

6. REPORTING OF RESULTS
6.1 The average of the values obtained shall be taken as the rpcci6c
gravity of the soil particles and shall be reported to the nearest 0.01. If
the two results differ by more than 0.03 the teats shall be repeated.

7
1%: 2720 ( Part lff/Sec 1) - 1986

Soil Testing Procedures and Equipment Subcommittee, BDC 23:3

Convcnsr Represenfing
Pros ALAM SINQE University of Jodhpur, Jodhpur
Members
SIIRI
_ AMAR- SINGI~ Central Building Research Institute, Roorkee
~RPUTY UIIIECTOIZ RESEA~CII Ministry of Railways
(FE-II ), RDSO
DEPUTY DIRECTOR RESEA~CII

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


( SM-III ), RDSO ( Alternafc )

for internal use by subscribing member only.


Druncron ( CSMRS ) Central Water Commission, New Delhi
DEPUTY DIIIEC’~OR( CSMRS ) ( a4lfnnafc)
PI~OFGOPAL RANJAN University of Roorkee, Roorkee
Dn S. C. HANI~A ( Al&mare )
DB SIIAEIII K. GULHAYI Indian Institute of Technology, New Delhi
Sunx H. K. GUIIA Geologists Syndicate Pvt Ltd, Calcutta
&RI H. N. BIIATTACIIAHAYA ( Altemnfe )
Sam 0. P. MALHOTRA Public Works Department, Chandigarh Adminis-
I tration
SH~I M. D. NAIR Associated Instruments Manufacturers ( I ) Pvt
Ltd, New Delhi
Pnos T. S. NA~ARAJ ( Alfe~dc )
Snnr N. M. PATEL Delhi College of Engineering, Delhi
SI~ICIP. JAOANATIIA RAO Central Road Research Institute, New Delhi
COL AVTAR Sr~o~r Engineer-in-Chief’s Branch, Army Hcadquartcrs
LT-COL V. K. KANIT~AB ( Alfernatc )
Snap S. D. VIDYAI~TIII Public Works Department, Government of Uttar
Pradesh, Lucknow
DR B. L. D~AWAN ( Alkmute )
BUREAU OF INDIAN STANDARDS

Headquatiers :
Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002
Telephones : 3 31 01 31,3 31 13 75 Telegrams : Manaksanstha
( Common to all Offices )
Regional Offices : Telephone
*Western ; Manakalaya, E9 MIDC, Marol, Andheri ( East ). 6 32 92 95
BOMBAY 400093
TEastern : l/l4 C. I. T. Scheme VII M, V. I. P. Road, 36 24 99
Maniktola, CALCUTTA 700054
Northern : SC0 445-446, Sector 35-C

Supplied by Book Supply Bureau to CSIR E JOURNALS Consortium


for internal use by subscribing member only.
CHANDIGARH 160036 { :1:::
Southern : C. I. T. Campus, MADRAS 600113 41 24 42
l 41 25 19
141 29 16
Branch Offices :
Pushpak,’ Nurmohamed Shaikh Marg, Khanpur, 2 63 48
4HMADABAD 380001 C 2 63 49
‘F’ Block, Unity Bldg, Narasimharaja Square, 22 48 05
BANGALORE 560002
Gangotri Complex, 5th Floor, Bhadbhada Road, T. T. Nagar. 6 27 l6
BHOPAL 462003
Plot No. 82/83, Lewis Road, BHUBANESHWAR 751002 5 36 27
5315 Ward No. 29, R. G. Barua Road. -
5th Byelane. GUWAHATI 781003
5-8-56C L N. Gupta Marg. (Nampally Station Road), 22 10 83
HYDERABAD 500001
R14 Yudhister Marg, C Scheme, JAIPUR 302005

11714188 Sarvodaya Nagar KANPUR 208005

Patliputra Industrial Estate, PATNA 800013 6 23 05


Hantex Bldg ( 2nd Floor ). Rly Station Road, 52 27
TRIVANDRUM 695001
inspection Office ( With Sale Point ):
Institution of Engineers ( India) Building, 1332 Shivaji Nagar, 5 24 35
PUNE 410005

*Sales Office in Bombay is st Novelty Chambers, Grant Road, 09 65 28


Bombay 400007
t.Sales Office in Calcutta is at 5 Chowringhee Approach, P. 0. Princrp 27 68 00
Street. Calcutta 700072