Firemask-Sq-2600 TDS
Firemask-Sq-2600 TDS
Firemask-Sq-2600 TDS
Intumescent paint FIREMASK SQ-2600(column) is a middle coat in solvent-borne anti-fire paint to provide fire-protection
of plants or facilities that have a steel construction and handle flammable materials.
FIREMASK SQ-2600(column) is approved with its superior heat insulation ability by Korea standard test for 2 hours
intumescent paint under license of KOREA INSTITUTE of CIVIL ENGINEERING and BUILDING TECHNOLOGY.
Recommended Middle-coat for columns in anti-fire paint to provide fire-protection for plants or facilities having steel
us e construction.
(On-site application, Interior use applicable)
Physical Properties
Finis h and
Flat / White
Color
Specific
Approx. 1.25 (Kg/L)
gravity
Solids by
65%
volume
Spreading rate
4.00 L/㎡ in 2,600 microns dry film thickness on a smooth surface.
(Theoretical)
Application details
Surface * Remove old paint film, dust, oil and grease, other contaminants.
preparation
Preceding * As a rust protective primer : Epoxy based primer KOREPOX PRIMER EP170, Red-lead based paint
coat KSM6030(Class 1), Inorganic zinc primer GALVANY IZ180N, Organic zinc primer
KOREPOX ZINC RICH PRIMER EZ175.
* If GALVANY IZ180N is applied as primer, mist coat will help to avoid popping of the subsequent coat.
Application The surface must be completely clean and dry. Do not apply when relative humidity is above 85%.
conditions The surface temperatures must be at least 3℃(5℉) above dew point to prevent condensation.
Film thicknes s Recommended per coat 1,333 microns wet film (Apply 3 times)
Recommended per coat 1,000 microns wet film (Apply 4 times)
Drying time
Set to touch 5h 2h
Dry through 24 h 12 h
※ The actual drying time is subject to the film thickness, ventilation, humidity etc., and drying time under
Subs equent KORETAN TOPCOAT UT6581, or according to specification. Top coat must be applied after 3 days(in
Coat summer) and 7 days (in winter) of the last mid-coat spay. Impossible for exterior Application. (If
interval Minimum 24 hours In highly humid conditions(ex. In heavy rain), recoating interval can be extended as
delayed period.
Packing Unit 18 L
Remarks
Handling * Avoid the cause of fire and direct sunlight during storage.
* Protect skin and eyes, and avoid prolonged breathing of Solvent Vapors.
1's t is s ue 2016-09-01
Revis ion
Dis claimer : The information in this data s heet is believed to the bes t of our knowledge bas ed on laboratory tes t and practical
experience. However, there are many factors affecting the performance of product and the product quality its elf, s o we are not
able to guarantee without the confirmation of the purpos e of us ing the product from us in writing. We res erve the right to change
the data without notice and you s hould check that this data s heet is current prior to us ing the product.