Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Deney 3

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

EXPERIMENT NUMBER: 23

A) EXPERIMENT NAME: Venturimeter Experiment

B) EXPERIMENTAL SETUP: Venturimeter

Figure 1: Venturimeter

Figure 2: Schematic Diagram of Venturimeter


C) AIM OF THE EXPERIMENT: To measure the discharge (volume flow) along a pipe by
using Venturimeter.

D)EXPERIMENTAL PROCEDURE:

1. Put the apparatus on the top of a Hydraulic Bench (supplied separately).

2. Connect the bench supply hose to the upstream (left) side of the Venturi meter.

3. Connect the downstream end of the Venturi Meter to the plastic tube supplied and direct it into
the Hydraulic Bench for flow measurement.

4. Set both the apparatus flow control and bench supply valve to approximately one third fully open
positions.

5. Check that the air valve on the upper manifold is tightly closed.

6. Switch on the bench supply and allow water to flow. To clear air from the manometer tubes it
may help to slightly tilt the apparatus or lightly tap the tubes with your finger.

7. Shut the apparatus flow control valve. Air will now be trapped in the upper parts of the
manometer tubing and the manifold.

8. Open the air valve just enough to allow water to rise approximately halfway up the manometer
scale.

9. Shut the air valve.

10. Adjust both the bench supply and the apparatus control valves to give full flow.

11. At this condition the maximum pressure difference between the Venturi inlet and throat should
be about 240 mm. You may need to connect the pump to the air valve, and add some air to see all
levels on the scale.

12. Watch the water levels for a few moments to ensure the air valve is sealing properly.
Sample Calculations

Figure 3: An incompressible fluid flowing along a convergent-divergent pipe with three pressure tappings

Bernoulli’s principle stated that a change in fluid velocity is directly linked to a change in its
pressure (or potential energy). To obey the laws of fluid dynamics for an incompressible fluid, its
velocity increases as it passes through a constriction, thereby conserving mass. If the flow remains
constant, its pressure must decrease, thereby conserving energy. Figure 11 shows an incompressible
fluid flowing along a convergent-divergent pipe with three pressure tappings. One tapping
measures upstream pressure at section 1, the second measures pressure at the throat (section 2) and
the third measures pressure downstream (section 3). The cross-sectional area at the upstream
section 1 is a1 and at throat section 2 is a2. Any other arbitrary section n is an. Piezometer tubes at
these sections register h1, h2 and hn as shown.

Symbol Meaning Units


V Velocity of flow m/s
D Diameter of the pipe m
h Head of water m
Δh Head differential of water m
Q Flow rate m3/s
a Cross-sectional areas m2
Cd Discharge coefficient -

Finding the Coefficient of Discharge (Cd)

The Bernoulli equation is a relation between pressure, velocity, and elevation in steady,
incompressible flow, and is expressed along a streamline and in regions where net viscous forces
are negligible as
𝑝1 𝑉 2 (1)
+ + 𝑔𝑧 = 𝑐𝑜𝑛𝑠𝑡𝑎𝑛𝑡
𝜌 2

It can also be expressed between any two points on a streamline as

𝑝1 𝑉12 𝑝2 𝑉22 (2)


+ + 𝑔𝑧1 = + + 𝑔𝑧2
𝜌 2 𝜌 2

The Bernoulli equation is an expression of mechanical energy balance and can be stated as: The
sum of the kinetic, potential, and flow energies of a fluid particle is constant along a streamline
during steady flow when the compressibility and frictional effects are negligible.

After these definitions, to explain the relationship between pressure, velocity and flow rate, the
mass balance and the Bernoulli equations between a location before the constriction (point 1) and
the location where constriction occurs (point 2) can be written as
𝑎
Q1=Q2 V1.a1= V2.a2 𝑉1 =𝑎2 𝑉2 (Mass Balance) (3)
1

𝑝1 𝑉12 𝑝2 𝑉22 (4)


+ = + Bernoulli Equation where (z1=z2)
𝛾 2𝑔 𝛾 2𝑔

Combining eqs. (3) and (4) and solving for velocity V2 gives

(5)
1 22𝑔(𝑝 −𝑝 )
𝑉2 = √ 𝑎2 2
𝛾[1−( ) ]
𝑎1

Eq. (5) can be written as

(6)
1 22𝑔(ℎ −ℎ )
𝑉2 = √ 𝑎2 2
[1−( ) ]
𝑎1

Theoretical Flow rate is

(7)
2𝑔(ℎ1 −ℎ2 )
𝑄𝑡𝑒𝑜 = 𝑎2 √ 𝑎 2
[1−( 2 ) ]
𝑎1

The flow actually losses some energy between section 1 and 2, and the velocity is not absolutely
constant across either of these sections. As a result, the measured value of Q is always slightly less
than value calculated from theory (Eq. 7). To allow for this, the equation becomes
(8)
2𝑔(ℎ1 −ℎ2 )
𝑄𝑒𝑥𝑝 = 𝐶𝑑. 𝑎2 √ 𝑎 2
[1−( 2 ) ]
𝑎1

Where Cd is an adjustment factor called the discharge coefficient, which you can find by
experiment. It is usually between 0.92 to 0.99.

V(lt) t (s) Qexp Qexp h1(m) h2(m) Δh=(h1-h2)m Cd D(m) V(m/s) Re


(lt/s) (m3/s)

E) REQUIREMENTS IN REPORT: Experiment number, name and aim of the experiment. The
table values, calculations and explanations. Plot a graph of Δℎ vs experimental flow rate (Qexp)
m3/s and find f (Δℎ) equation in terms of experimental flow rate Qexp.Find Cd. Plot a graph of
Reynolds number (Re) vs Cd and find Cd equation in terms of Reynolds number (Re).

You might also like