Autocon III 400 Brochure
Autocon III 400 Brochure
Autocon III 400 Brochure
0 06/2017-E
Additional Information
• Product dimensions (h x w x d) 177 x 447 x 457 mm
• Net weight 12.5 kg
• Line frequency 220-240 V 50/60 Hz (UH 400/UH 401)
• Line frequency 100-127 V 50/60 Hz (UH 400U/UH 401U)
• Maximum unipolar and bipolar power 400 W
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
2
Provides all functions with improved properties for diverse applications
• 18 unipolar and bipolar cutting modes such as, for example, bipolar resection
• 25 unipolar and bipolar coagulation modes such as ROBI® and the BIVASCULARSAFE
mode
Various models
• UH 400 High-End
Generator, suitable for
universal use
• UH 401 High-End
Generator, also suitable
for vessel sealing
Generator Applications
The AUTOCON® III 400 is a multidisciplinary HF unit that can be used
in practically all surgical disciplines:
• Neurosurgery
• Otorhinolaryngology
• Thorax
• Gastroenterology
• Laparoscopy
• Gynecology
• Urology
• Arthroscopy and Sports Medicine
• Spine Surgery
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
New technologies have been integrated into the current generation of the
AUTOCON® family
• For bipolar resection, the energy output has been enhanced and expanded
• For the ROBI® mode, a performance setting has been defined so that the
instruments are not overtaxed with incorrect settings
• The BIVASCULARSAFE mode for sealing arteries, veins and tissue has been
integrated into version UH 401
3
AUTOCON® III 400
The new high-frequency generator with perfected settings
The introduction of the new AUTOCON® III 400 marks a new era in HF surgery for
KARL STORZ. The experience and know-how accumulated over many years was incorporated
into the development of this unit in order to provide new, optimized modes for bipolar
resection, ROBI® instruments and vessel sealing. The AUTOCON® III 400 series features two
different models. The difference between UH 400 / UH 400U and UH 401 / UH 401U is that
the UH 401 model is equipped with the additional BIVASCULARSAFE mode for vessel sealing.
The new HF generator from KARL STORZ has been further enhanced and optimized,
particularly with regard to the performance of bipolar applications. It therefore ideally
complements the KARL STORZ systems for bipolar resection. Precise initial cutting and
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
exactly coordinated power regulation enables the unit to deliver optimal energy for bipolar
resection and thus leads to perfect results.
2. ROBI®
Mode for rotating bipolar instruments ROBI®
The ROBI® mode is used with bipolar laparoscopic instruments for coagulation. In contrast
to the previous generation, the peak voltage of the AUTOCON® III 400 has been limited to
110 Vp to avoid causing damage to the sensitive bipolar instruments.
4
3. BIVASCULARSAFE
Mode for the bipolar sealing of vessels
The BIVASCULARSAFE mode is used for the permanent sealing of veins, arteries and tissue
bundles and is integrated in the UH 401 model. Conventional instruments cannot be used in
this mode.
Automatic instrument recognition and assignment is just one factor that reflects the
intelligence of the HF generator. The unipolar and bipolar sockets flash to clearly indicate
to the user that the connection is correct. Once the socket and cable are connected
successfully, the socket light goes out and the selection panel of the socket lights up on
the touch display. The user-friendly signs and symbols can be used to access the required
setting. If the socket is connected to a RFID cable, e.g., for bipolar resection, the settings
are transmitted automatically without touching the user surface. The unit recognizes the
connecting cable used and automatically selects the correct parameters for the connected
instruments. In addition, the tiny RFID chip in the cable informs the user about the number
of times the cable can be used and provides an explanation of the application. The
AUTOCON® III 400 can be easily integrated into the OR1™ operating room. Consequently, the
unit can be controlled directly from the sterile area and the settings can be adjusted swiftly
and smoothly as required.
The high-resolution touch display of the HF generator allows intuitive use and is therefore
very user-friendly. In addition to standard procedures, which are already stored in the unit,
the user is able to create and save individual procedures. The informative symbols of the
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
AUTOCON® III 400 allow an intuitive selection of modes and programs. Furthermore, the user-
friendly quick access function allows the required settings to be activated with a maximum of
two clicks.
5
Bipolar Resection
With the bipolar resectoscope and the new loop design, KARL STORZ has revolutionized
resection in saline in the fields of urology and gynecology.
Controlled initial cutting and application of energy to the tissue with pinpoint accuracy
Use of saline solution
Reduced risk of TUR syndrome; significantly longer operating time possible
Improved hemostasis
Enables resection of patients with anticoagulants and antiaggregants
Additional bipolar techniques
Bipolar enucleation and vaporization
6
Testimonials
7
Bipolar Resection in Urology – System Overview
UH 400
UF 902 UH 801
Electrotome, bipolar
27040 EBH
Cutting Loop,
24/26 Fr., bladder
27040 JB130
Cutting Loop,
24/26 Fr., bladder
27040 JBE130
8
Bipolar Treatment Methods in Gynecology
In addition to applications in urology, the bipolar resection mode can also be used in
gynecology.
Less risk of interference with other Increased risk of interference with other
electronic equipment, e.g. ECG, which electronic equipment
are connected to the patient • Voltage in unipolar resection is always
higher as the current has to travel longer
through the body
Advantage: Concern:
Physiological saline solution as distension Fluid absorption of non-physiological
medium irrigation fluid
• Result: Easily processed by the body, • Result: Hyponatremia, hypervolemia,
non-toxic, more cost-efficient glycine intoxication
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
Testimonial
9
Bipolar Resection in Gynecology – System Overview
UH 400
UF 902 UH 801
Working Element Set, bipolar, 26 Fr. Working Element Set, bipolar, 22 Fr.
26040 NB 26055 NB
26040 JB1
10
ROBI® Mode for Rotating Bipolar Instruments
By limiting the maximum power setting in the ROBI® mode, KARL STORZ has significantly
reduced the risk of damage to bipolar instruments during use. Consequently, the user can
now select all possible performance settings to achieve the desired surgical outcome without
the risk of overloading the instrument with too much power.
With the rotating, bipolar instruments for minimally invasive surgery in 3.5 mm and 5 mm in
conjunction with the AUTOCON® III 400 generator and components for an optimal imaging
chain, KARL STORZ offers a modular system that provides safety, stability and precision. All
instruments in the ROBI® range feature a modular construction and can be rotated 360°. They
are easy to use, easy to clean, and autoclavable.
Combining the ROBI® instruments with the ROBI® mode of the HF generator allows
the optimization of minimally invasive laparoscopic interventions to make them more
straightforward, faster and safer. As the adjustable maximum voltage is limited in the ROBI®
mode, damage caused by too high a voltage can be prevented. This leads to significantly
lower repair costs.
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
11
ROBI® 3.5 mm for Minimally Invasive, Laparoscopic Surgery –
System Overview
UH 400
Two-Pedal Footswitch Bipolar High Frequency Cord Bipolar High Frequency Cord
12
ROBI® 3.5 mm for Minimally Invasive, Laparoscopic Surgery –
System Overview
UH 400
Two-Pedal Footswitch Bipolar High Frequency Cord Bipolar High Frequency Cord
38600, 38700
38151
For further inserts and instruments please see the following pages
13
Inserts and Complete Instruments with Single Action Jaws
38610 CL
38651 CL
38610 KF
38651 KF
ROBI® Scissors,
ROBI® Scissors Insert, length 36 cm
length 36 cm © KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
38610 MT
38651 MT
ROBI® Scissors,
ROBI® Scissors Insert, length 36 cm
length 36 cm
38610 MZ
38651 MZ
14
Inserts and Complete Instruments with Double Action Jaws
38610 OM
38651 OM
38610 ML
38651 ML
38610 WA
38651 WA
ROBI® Scissors,
ROBI® Scissors Insert, length 36/43 cm
length 36/43 cm
15
The mode for permanent vessel sealing –
BIVASCULARSAFE
During the development of the AUTOCON® III product family, the optimization of HF
coagulation led to the creation of a further discipline, the so-called vessel sealing. This
process allows a high-frequency current to flow through the vessel in combination with
optimal pressure delivery. The heat generated by the energy input in the tissue changes the
structure of the collagen and elastin fibers. These then re-form to create a plastic-like sealing
zone. Vessel sealing enables the sealing of larger vessels that can withstand high burst
pressure.
Vessel sealing produces the same effects as coagulation. With the energy input into tissue,
the intra- and extracellular fluids slowly begin to vaporize and the collagen fibers denature.
The heat-resistant elastin fibers also denature with rising temperatures. Sealing prevents a
rapid increase in vaporization as well as carbonization so that the tissue structure is largely
maintained during sealing. The pressure exerted compresses the vessel walls until the
collagen and elastin fibers fuse with the remaining tissue to form a seal zone.
Hug B, Haag R
(3. Auflage) Medizintechnik (Medical Technology)
Offprint of the chapter
“Hochfrequenzchiurgie (High Frequency Surgery)”
28: 533-538
16
Combination with Other Units
High-frequency units have now become indispensable tools in modern medicine. Numerous
interventions are performed every day that require the use of energy application systems.
Thermal energy from HF units generates surgical smoke and unpleasant odors which can
cause the OR staff to suffer headaches and nausea. Furthermore, the generated smoke
disturbs endoscopic visualization and presents a further risk of hindering surgeons in their
work. The S-PILOT™ from KARL STORZ, with corresponding smoke evacuation filters,
provides excellent visibility through effective smoke evacuation and protects personnel from
exposure to unpleasant odors.
17
As smoke evacuation often leads to a loss in pressure, a reliable unit is required to restore
gas loss safely and securely and to ensure that a stable cavity is maintained. The new
insufflators ENDOFLATOR® 40 and ENDOFLATOR® 50 offer this reliability. The S-PILOT™ is
always connected to a vacuum source, e.g., the UNIMAT® 30. This forms an interface which is
able to control the underpressure generated in the tube and the suction container. Thus, the
UNIMAT® 30 is used as a vacuum source and container and allows fluid suction and smoke
evacuation in parallel. As an alternative to the UNIMAT® 30, an on-site central vacuum can be
connected to the suction container.
25 3200 01 UNIMAT® 30, Suction Pump Set, power supply 230 VAC,
50/60 Hz
including:
Bacterial Filter
Secretion Bottle
Bottle Cap
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
18
AUTOCON® III 400
UH 400 AUTOCON® III 400 High-End, UH 401 AUTOCON® III 400 High-End,
power supply 220-240 VAC, BIVASCULARSAFE,
50/60 Hz power supply 220–240 VAC,
including: 50/60 Hz
Mains Cord including:
Mains Cord
UH 400U AUTOCON® III 400 High-End, UH 401U AUTOCON® III 400 High-End,
power supply 100-127 VAC, BIVASCULARSAFE,
50/60 Hz power supply 100–127 VAC,
including: 50/60 Hz
Mains Cord including:
Mains Cord
Specifications:
Insulation Type / Classification
EMC IEC 60601-1-2
Degree of protection provided by the housing IP 21
Protection class according to EN 60601-1 I
Applied part type according to EN 60601-1 CF
Classification according to EU Directive 93/42/EEC Ilb
Mains Connection
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
19
Accessories for AUTOCON® III 400
20
© KARL STORZ 96212021 UNITS 13 2.0 06/2017/EW
Notes
21
22
Notes
It is recommended to check the suitability of the product for the intended procedure prior to use.
23
96212021 UNITS 13 2.0 06/2017/EW-E