Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
11 views

Tutorials and Assignment #5

The document provides details for a structural engineering tutorial and assignment on column design. It includes questions about checking if a column is short, determining reinforcement requirements, and designing longitudinal reinforcement for columns under axial and biaxial loading conditions.

Uploaded by

Chin Ho Cheung
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

Tutorials and Assignment #5

The document provides details for a structural engineering tutorial and assignment on column design. It includes questions about checking if a column is short, determining reinforcement requirements, and designing longitudinal reinforcement for columns under axial and biaxial loading conditions.

Uploaded by

Chin Ho Cheung
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

CSE30310 Tutorial #5 and Assignment #4 Design of columns

Tutorials:
Q1. A short, braced column is subjected to an ultimate applied axial load of 3000kN and a nominal
moment only. Using the design data given:
1. Check that the column is short;
2. Determine the required area of main reinforcement; and
3. Determine suitable links.
Given:
Characteristic concrete strength fcu = 40N/mm2.
Characteristic strength of main steel fy = 460N/mm2.
Width of column b=350 mm
Depth of column h = 375 mm
Clear height between the end restraints about both axis = 5.0 m
End condition at the top of the column for x-x axis = 1
End condition at the top of the column for y-y axis = 2
End condition at the bottom of the column for x-x axis = 3
End condition at the bottom of the column for y-y axis = 3

Q2. Design the longitudinal reinforcement for the 500 by 300 mm column section if N = 2300 kN, Mx-x =
300 kNm and My-y = 120kN·m.
Given:
Characteristic concrete strength fcu = 40 N/mm2.
Characteristic strength of main steel fy = 460 N/mm2.
The column interaction design Chart No.39 is attached.

1
2
3
Assignments:
Q3. Use the simplified method of HK2013 to design the longitudinal reinforcement for the braced slender
column as shown below, for bi-axial bending. The column’s effective lengths about both axes are 6.5 m.
Given:
Characteristic concrete strength fcu = 40N/mm2.
Characteristic strength of main steel fy = 460N/mm2.
Axial load N=2500 kN; double curvature bending moments:
Support 1 - M1x=200 kN·m, M1y=100 kN·m;
Support 2 - M2x=250 kN·m, M2y=120 kN·m.

50

400
Y Y

50
X

50 50
500

Fig.Q3
Q4. Figure Q4 shows a square short column with the dimensions of 600 mm by 600 mm and reinforced
with T32 bars. Consider a 45 mm cover to main steel reinforcement and assume that the characteristic
material strengths are fy = 460 N/mm2 for steel and fcu = 30 N/mm2 for concrete.
(1) Estimate the axial load-carrying capacity (Na) of the column assuming there is no bending and a
nominal eccentricity.
(2) The column is now subjected to equal biaxial bending (the moment about x-x axis is equal to the
moment about y-y axis). Under an axial load of Na/2, calculate the maximum moment the column can
safely resist.

Fig.Q4

4
5

You might also like