Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Schneider Electric - Altivar-312 - ATV312HU40N4

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Product datasheet

Specifications

variable speed drive ATV312 -


4kW - 9.2kVA - 150 W - 380..500
V - 3-phase supply
ATV312HU40N4

notification_critical_stroke To be discontinued on: Sep 4, 2027

Discontinued - Service only


notification_critical_stroke To be end-of-service on: Sep 4, 2033
notification_critical_stroke

Main
Range Of Product Altivar 312

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product Or Component Type Variable speed drive

Product Destination Asynchronous motors

Product Specific Application Simple machine

Assembly Style With heat sink

Component Name ATV312

Motor Power Kw 4 kW

Motor Power Hp 5 hp

[Us] Rated Supply Voltage 380...500 V - 15...10 %

Supply Frequency 50...60 Hz - 5...5 %

Network Number Of Phases 3 phases

Line Current 13.9 A at 380 V, Isc = 5 kA


10.6 A at 500 V

Emc Filter Integrated

Apparent Power 9.2 kVA

Maximum Transient Current 14.3 A for 60 s

Power Dissipation In W 150 W at nominal load

Speed Range 1…50

Asynchronous Motor Control Sensorless flux vector control with PWM type motor control signal
Profile Factory set : constant torque

Electrical Connection Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm²
AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 5 mm² AWG 10

Supply Internal supply for logic inputs: 19...30 V 100 mA, protection type: overload and
short-circuit protection
Internal supply for reference potentiometer (2.2 to 10 kOhm): 10...10.8 V 10 mA,
protection type: overload and short-circuit protection

Communication Port Protocol Modbus


CANopen

Ip Degree Of Protection IP20 on upper part without cover plate


IP21 on connection terminals
IP31 on upper part
IP41 on upper part

Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.

Apr 1, 2024 1
Option Card Communication card for CANopen daisy chain
Communication card for DeviceNet
Communication card for Fipio
Communication card for Modbus TCP
Communication card for Profibus DP

Complementary
Supply Voltage Limits 323…550 V

Prospective Line Isc 5 kA

Continuous Output Current 9.5 A at 4 kHz

Output Frequency 0…500 Hz

Nominal Switching Frequency 4 kHz

Switching Frequency 2...16 kHz adjustable

Transient Overtorque 170…200 % of nominal motor torque

Braking Torque 150 % during 60 s with braking resistor


100 % with braking resistor continuously
150 % without braking resistor

Regulation Loop Frequency PI regulator

Motor Slip Compensation Suppressable


Automatic whatever the load
Adjustable

Output Voltage <= power supply voltage

Tightening Torque Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6: 0.6 N.m
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 1.2 N.m

Insulation Electrical between power and control

Analogue Input Number 3

Analogue Input Type AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance: 30000 Ohm
AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm
AI3 configurable current 0...20 mA, impedance: 250 Ohm

Sampling Duration AI1, AI2, AI3: 8 ms analog


LI1...LI6: 4 ms discrete

Response Time AOV, AOC 8 ms for analog


R1A, R1B, R1C, R2A, R2B 8 ms for discrete

Linearity Error +/- 0.2 % for output

Analogue Output Number 1

Analogue Output Type AOC configurable current: 0...20 mA, impedance: 800 Ohm, resolution: 8 bits
AOV configurable voltage: 0...10 V, impedance: 470 Ohm, resolution: 8 bits

Discrete Input Logic Logic input not wired (LI1...LI4), < 13 V (state 1)
Negative logic (source) (LI1...LI6), > 19 V (state 0)
Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)

Discrete Output Number 2

Discrete Output Type Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NC - 100000 cycles

Minimum Switching Current R1-R2 10 mA at 5 V DC

Maximum Switching Current R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms
R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms
R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms
R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms

Discrete Input Number 6

Discrete Input Type (LI1...LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm

2 Apr 1, 2024
Acceleration And Deceleration S, U or customized
Ramps Linear adjustable separately from 0.1 to 999.9 s

Braking To Standstill By DC injection

Protection Type Input phase breaks: drive


Line supply overvoltage and undervoltage safety circuits: drive
Line supply phase loss safety function, for three phases supply: drive
Motor phase breaks: drive
Overcurrent between output phases and earth (on power up only): drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: motor

Insulation Resistance >= 500 mOhm 500 V DC for 1 minute

Local Signalling 1 LED (red) for drive voltage


Four 7-segment display units for CANopen bus status

Time Constant 5 ms for reference change

Frequency Resolution Analog input: 0.1...100 Hz


Display unit: 0.1 Hz

Connector Type 1 RJ45 for Modbus/CANopen

Physical Interface RS485 multidrop serial link

Transmission Frame RTU

Transmission Rate 10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen
4800, 9600 or 19200 bps for Modbus

Number Of Addresses 1…127 for CANopen


1…247 for Modbus

Number Of Drive 127 for CANopen


31 for Modbus

Marking CE

Operating Position Vertical +/- 10 degree

Outer Dimension 215 x 185 x 158 mm


184 x 140 x 150 mm
402 x 239 x 192 mm

Height 184 mm

Width 142 mm

Depth 152 mm

Net Weight 3.1 kg

Environment
Dielectric Strength 2410 V DC between earth and power terminals
3400 V AC between control and power terminals

Electromagnetic Compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to
IEC 61000-4-3

Standards IEC 61800-3


IEC 61800-5-1

Product Certifications CSA


C-Tick
DNV
NOM
GOST
UL

Pollution Degree 2

Protective Treatment TC

Apr 1, 2024 3
Vibration Resistance 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6

Shock Resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27

Relative Humidity 5…95 % without condensation conforming to IEC 60068-2-3


5…95 % without dripping water conforming to IEC 60068-2-3

Ambient Air Temperature For -25…70 °C


Storage
Ambient Air Temperature For -10…50 °C without derating (with protective cover on top of the drive)
Operation -10…60 °C with derating factor (without protective cover on top of the drive)

Operating Altitude <= 1000 m without derating


1000...3000 m with current derating 1 % per 100 m

Packing Units
Unit Type Of Package 1 PCE

Number Of Units In Package 1 1

Package 1 Height 20.791 cm

Package 1 Width 21.71 cm

Package 1 Length 21.828 cm

Package 1 Weight 3.151 kg

Unit Type Of Package 2 S06

Number Of Units In Package 2 12

Package 2 Height 73.5 cm

Package 2 Width 60.0 cm

Package 2 Length 80.0 cm

Package 2 Weight 47.0 kg

Contractual warranty
Warranty 18 months

4 Apr 1, 2024
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-
class environmental performance. Green Premium promises compliance with the latest regulations,
transparency on environmental impacts, as well as circular and low-CO2 products.
Guide to assessing product sustainability is a white paper that clarifies global eco-label
standards and how to interpret environmental declarations.
Learn more about Green Premium arrow2_right
Guide to assess a product’s sustainability arrow2_right

RoHS/REACh

Well-being performance

 Mercury Free

 Rohs Exemption Information Yes

Certifications & Standards


Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)

EU RoHS Declaration

China Rohs Regulation China RoHS declaration

Weee The product must be disposed on European Union markets following specific waste
collection and never end up in rubbish bins

Circularity Profile End of Life Information

Apr 1, 2024 5

You might also like