1TB02012 012D03 Una S1 ZZ DWG ST 30001
1TB02012 012D03 Una S1 ZZ DWG ST 30001
1TB02012 012D03 Una S1 ZZ DWG ST 30001
1 2 3 4 5 1TB02012-012D03-UNA-S1-ZZ-DWG-ST-30001 6 7
34275
2475
250 THK. RC UPSTAND 75
85 1840
(TYP.) TOC +4.650
5050
75
500
C04 C04 C04 C01
500
2575
2575
C02
1799
1799
1880
200Wx50DEEP
C04 C01 C01 C01 1675 OPENING
B C03
C03 C03
2200
C04
RF-B03
RC200 C03
C01
RF-B06
SSL +3.840
C C02 C03 250 THK. RC UPSTAND
200Wx50DEEP (TYP.) TOC +4.650
2775
OPENING
C03
C01 C03
RF-B02A
606
RF-B05
C04 C03
RC200
4860
OPENING RC200
C03 200Wx50DEEP
RF-B04
OPENING
E C04 200Wx50DEEP
C04
2190
OPENING
RF-B02
4790
1TB02012-012D03-UNA-S1-ZZ-DWG-ST-30001
3224 RC200
F C04 SSL +3.840
C03
C04 200Wx50DEEP
OPENING
626
775
696
C06
400
C05
RC300
RF-B08
2240 RC220 SSL +3.890
SSL +3.840
C02 C05
3D VIEW -1
ROOF LEVEL
1 : 100
NOTES:-
1. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT DRAWINGS AND
SPECIFICATIONS.
2. ALL STRUCTURAL MEMBERS ARE CENTRAL ABOUT GRID UNLESS NOTED OTHERWISE.
3. THE +0.00 LEVEL FOR EACH BUILDING CORRESPONDS TO THE FINISHED GROUND FLOOR LEVEL FOR THAT
SPECIFIC BUILDING, REFER TO THE ARCHITECTURAL DRAWINGS FOR THE RELATION BETWEEN THIS LOCAL
BUILDING LEVEL AND THE CORRESPONDING MASTERPLAN DATUM LEVEL.
4. REFER TO THE BUILDING SERVICES DRAWINGS FOR THE FLOOR SHAFTS, PENETRATIONS, BUILDERSWORK,
SUMPS, DRAINS, PETROL INTERCEPTORS, MANHOLES, CHAMBERS, AND ALL OTHER SERVICES.
5. OPENING SMALLER THAN 200mm ARE NOT SHOWN IN THE STRUCTURAL GENERAL ARRANGEMENT
DRAWINGS AND SHALL BE REFERED FROM BUILDING SERVICES DRAWINGS.
6. REFER TO THE SPECIALIST DRAWINGS FOR OTHER SERVICES, INCLUDING UTILITIES, SECURITY, KITCHEN,
VT, FLS, ICT, AV, AND ALL OTHER SPECIALIST DRAWINGS.
7. REFER TO THE STRUCTURAL GENERAL NOTES AND STANDARD DETAILS DRAWINGS FOR THE STRUCTURAL
DETAILING TO BE CONSIDERED ALONG WITH THE GENERAL ARRANGEMENT DRAWINGS AND
REINFORCEMENT DETAILS.
8. FOR COLUMN, BEAM & FOUNDATION SCHEDULES REFER DRAWING NO.
1TB02012-012D03-UNA-S1-ZZ-DWG-ST-60001.
9. FOR SLAB REINFORCEMENT REFER DRAWING NO. 1TB02012-012D03-UNA-S1-GF-DWG-ST-40001 AND
1TB02012-012D03-UNA-S1-R1-DWG-ST-40002.
10. FOR LAYOUT OF UPSTAND REFER TO ARCHTECTURAL DRAWINGS.
11. REFER TO THE STRUCTURAL LOADING PLAN DRAWING FOR THE LOADING ALLOWANCES CONSIDERED IN
THE STRUCTURAL DESIGN (DEPENDING ON BUILDING USAGES AND OCCUPANCIES), NOTING THAT NO
CONSTRUCTION TRUCKS SHOULD BE ALLOWED ON THE BUILDINGS ROOF SLAB UNLESS NOTED OTHER
WISE ON THE STRUCTURAL LOADING PLAN.
12. FOR EXTERNAL TERRACES SLAB ON GRADE DETAILS, REFER TO LANDSCAPE DRAWINGS.
13. FOR GENERAL DETAILS RELATED TO PLINTH REINFORCEMENT REFER TO DRAWING NUMBER
1TB02012-012D03-UNA-XX-XX-DWG-ST-00019.
14. FOR SETTING OUT AND DIMENSIONS OF PLINTH REFER TO RELEVANT MEP DRAWINGS.