Licence Number 011-7S3021 R


Annex to Solar Keymark Certificate Date issued 2021-06-08
Issued by DIN CERTCO
Licence holder Zhejiang shentai solar energy co.,ltd Country China
Brand (optional) Suntask, SHENTAI Web www.suntasksolar.com
Street, Number 199 lianhong road,yuanhua industry zone E-mail info@suntasksolar.com
Postcode, City 314416 haining, zhejiang Tel +86 573-87861111

Collector Type Evacuated tubular collector


Power output per collector

area (AG)
Gb = 850 W/m2, Gd = 150 W/m2 & u = 1.3 m/s

length

height
ϑ m - ϑa

width
Gross

Gross

Gross

Gross
Collector name
0K 10 K 30 K 50 K 70 K 100 K
m² mm mm mm W W W W W W
SCM10-01 1.56 1,915 815 106 634 617 574 517 446 316
SCM12-01 1.85 1,915 965 106 751 731 680 612 528 374
SCM15-01 2.28 1,915 1,190 106 925 901 838 755 651 462
SCM16-01 2.42 1,915 1,265 106 984 958 891 802 692 491
SCM18-01 2.71 1,915 1,415 106 1,100 1,072 997 897 774 549
SCM20-01 3.00 1,915 1,565 106 1,217 1,185 1,102 993 857 607
SCM22-01 3.28 1,915 1,715 106 1,334 1,299 1,208 1,088 939 665
SCM24-01 3.57 1,915 1,865 106 1,450 1,413 1,313 1,183 1,021 723
SCM25-01 3.72 1,915 1,940 106 1,509 1,469 1,366 1,230 1,062 753
SCM28-01 4.15 1,915 2,165 106 1,684 1,640 1,525 1,373 1,185 840
SCM30-01 4.43 1,915 2,315 106 1,800 1,753 1,630 1,468 1,267 898
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Power output per m² gross area 406 396 368 331 286 203
Performance parameters test method Steady state - outdoor
Performance parameters (related to AG) η0, b a1 a2 a3 a4 a5 a6 a7 a8 Kd
Units - W/(m²K) W/(m²K²) J/(m³K) - J/(m²K) s/m W/(m²K⁴) W/(m²K⁴) -
Test results 0.404 0.949 0.011 0.000 0.000 5,330 0.000 0.000 0.000 1.04
Incidence angle modifier test method Steady state - outdoor
Yes
Incidence angle modifier Angle 10° 20° 30° 40° 50° 60° 70° 80° 90°
Transversal KθT,coll 1.02 1.04 1.14 1.24 1.36 1.46 0.97 0.49 0.00
Longitudinal KθL,coll 1.00 0.99 0.97 0.95 0.91 0.84 0.69 0.23 0.00
Heat transfer medium for testing Water
Flow rate for testing (per gross area, A G) dm/dt 0.020 kg/(sm²)
Maximum temperature difference during thermal performance test (ϑm-ϑa)max 69.57 K
Standard stagnation temperature (G = 1000 W/m²; ϑa = 30 °C) ϑstg 210 °C
Maximum operating temperature ϑmax_op 250 °C
Maximum operating pressure pmax,op 1000 kPa
Intertek Testing Services Shenzhen Ltd. Guangzhou
Testing laboratory http://www.intertek.com
Branch
Test report(s) 161107081GZU-001 Dated 2018/5/2

Comments of testing laboratory Datasheet version: 6.1, 2019-09-26


Above efficiency parameters come from test type SCM10-01;

DIN CERTCO ● Alboinstraße 56 ● D-12103 Berlin


Tel: +49 30 7562-1131 ● Fax: +49 30 7562-1141 ● E-Mail: info@dincertco.de ● www.dincertco.de
Page 2/2
Annex to Solar Keymark Certificate Licence Number 011-7S3021 R
Supplementary Information Issued 2021-06-08
Annual collector output in kWh/collector at mean fluid temperature ϑm
Standard Locations Athens Davos Stockholm Würzburg
Collector name ϑm 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C
SCM10-01 1,177 982 754 972 772 564 711 551 394 767 597 422
SCM12-01 1,393 1,163 892 1,151 914 668 842 653 466 908 707 500
SCM15-01 1,718 1,434 1,101 1,419 1,127 823 1,038 805 575 1,120 872 616
SCM16-01 1,826 1,525 1,170 1,508 1,198 875 1,103 856 611 1,190 927 655
SCM18-01 2,043 1,705 1,309 1,687 1,340 979 1,234 957 684 1,331 1,036 733
SCM20-01 2,259 1,886 1,447 1,866 1,482 1,083 1,365 1,059 756 1,473 1,146 810
SCM22-01 2,476 2,067 1,586 2,045 1,624 1,187 1,496 1,160 828 1,614 1,256 888
SCM24-01 2,692 2,248 1,725 2,224 1,766 1,291 1,627 1,262 901 1,755 1,366 966
SCM25-01 2,801 2,338 1,794 2,313 1,837 1,342 1,692 1,312 937 1,826 1,421 1,005
SCM28-01 3,125 2,609 2,002 2,582 2,050 1,498 1,888 1,465 1,046 2,037 1,586 1,121
SCM30-01 3,342 2,790 2,141 2,761 2,192 1,602 2,019 1,566 1,118 2,178 1,696 1,199

Annual output per m² gross area 754 629 483 623 494 361 455 353 252 491 382 270
Annual efficiency, ηa 43% 36% 27% 38% 30% 22% 39% 30% 22% 39% 31% 22%
Fixed or tracking collector Fixed (slope = latitude - 15°; rounded to nearest 5°)
Annual irradiation on collector plane 1765 kWh/m² 1630 kWh/m² 1166 kWh/m² 1244 kWh/m²
Mean annual ambient air temperature 18.5°C 3.2°C 7.5°C 9.0°C
Collector orientation or tracking mode South, 25° South, 30° South, 45° South, 35°
The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annual collector
performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver. 6.1 (September 2019). A detailed
description of the calculations is available at http://www.estif.org/solarkeymarknew/
Additional Information
Collector heat transfer medium Water-Glycole
The collector is deemed to be suitable for roof integration No

The collector was tested successfully under the following conditions:


Climate class (A+, A, B or C) C --
G (W/m2) > 800 ϑa (°C) > 10 HX (MJ/m2) > 420
Maximum tested positive load 2400 Pa
Maximum tested negative load 2400 Pa
Hail resistance using steel ball (maximum drop height) 1.4 m
Additional collector attribute(s)
Using external power source(s) for normal operation Active or passive measure(s) for self-protection
Co-generating thermal and electrical power Façade collector(s)
Energy Labelling Information Additional Informative Technical Data
2
Reference Area, Asol (m ) Hydraulic Designation Code Aperature Area, Aa (m2)
SCM10-01 1.56 1-H-12S-C:19,891-D 0.94
SCM12-01 1.85 1-H-12S-C:19,1041-D 1.12
SCM15-01 2.28 1-H-12S-C:19,1266-D 1.40
SCM16-01 2.42 1-H-12S-C:19,1341-D 1.49
SCM18-01 2.71 1-H-12S-C:19,1491-D 1.68
SCM20-01 3.00 1-H-12S-C:19,1641-D 1.87
SCM22-01 3.28 1-H-12S-C:19,1791-D 2.05
SCM24-01 3.57 1-H-12S-C:19,1941-D 2.24
SCM25-01 3.72 1-H-12S-C:19,2016-D 2.33
SCM28-01 4.15 1-H-12S-C:19,2241-D 2.61
SCM30-01 4.43 1-H-12S-C:19,2391-D 2.80
Data required for CDR (EU) No 811/2013 - Reference Area A sol Data required for CDR (EU) No 812/2013 - Reference Area A sol
Collector efficiency (ηcol) 35% Zero-loss efficiency (η0 ) 0.41 --
First-order coefficient (a1) 0.95 W/(m²K)
Remark: Collector efficiency (ηcol) is defined in CDR (EU) No 811/2013 Second-order coefficient (a ) 0.011 W/(m²K²)
2
as collector efficiency of the solar collector at a temperature difference
Incidence angle modifier IAM (50°) 1.16 --
between the solar collector and the surrounding air of 40 K and a Remark: The data given in this section are related to collector reference
global solar irradiance of 1000 W/m², expressed in % and rounded to area (A sol ) which is aperture area for values according to EN 12975-2 or
the nearest integer. Deviating from the regulation ηcol is based on
gross area for ISO 9806. Consistent data sets for either aperture or gross
reference area (Asol) which is aperture area for values according to EN
area can be used in calculations like in the regulation 811 and 812 and
12975-2 or gross area for ISO 9806:2017.
simulation programs.
DIN CERTCO ● Alboinstraße 56 ● D-12103 Berlin
Tel: +49 30 7562-1131 ● Fax: +49 30 7562-1141 ● E-Mail: info@dincertco.de ● www.dincertco.de