Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

EA-PSB 10000 2U: Programmable Bidirectional DC-Power Supply

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

EA-PSB 10000 2U

Programmable Bidirectional
DC-Power Supply

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


EA-PSB 10000 2U
1.5 KW / 3.0 KW
Programmable Bidirectional
DC-Power Supply

Features
 Wide range input, 110 V - 240 V +10 % 1ph AC  Color 5“ TFT display with touch control and intuitive
 Active Power-Factor-Correction, typical 0.99 user interface

 Bidirectional power supply, 2-quadrants in  Galvanically isolated Share-Bus for parallel operation
source and sink of all power classes in the 10000 series

 In load operation, regenerative with energy recovery  Master-Slave bus for parallel operation of up to 64
into the grid units of all power classes in the 10000 series

 Very high efficiency up to over 95 %  Integrated function generator with predefined curves

 Voltage from 0 - 10 V up to 0 - 1500 V  Predefined automotive test procedures for LV123,


LV124 and LV148
 Currents from 0 - 6 A up to 0 - 120 A
 Integrated battery test mode, battery and fuel cell
 Flexible power regulated DC input/output stages
simulation
(autoranging)
 Photovoltaics test mode, MPPT, EN 50530
 Regulation mode CV, CC, CP, CR with fast crossover
 Command languages and drivers: SCPI and ModBus,
 Digital regulation, high resolution with 16bit ADCs and
LabVIEW, IVI
DACs

Build-in Interfaces Optional Interfaces Software


 USB  CAN  EA-Power Control
 Ethernet  CANopen  EA-Battery Simulator
 Analog  RS232
 USB Host  Profibus
 Master-Slave-Bus  EtherCAT
 Share-Bus  Profinet, with one or two ports
 Modbus, with one or two ports
Ethernet, with one or two ports

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


General specifications
AC-Input
Voltage, Phases 110 V / 120 V / 208 V / 220 V / 230 V / 240 V ±10%, 1ph AC (110 V / 120 V 1ph with Derating, see model table)
Frequency 45-66 Hz
Power factor >0.99
Leakage current < 3.5 mA
Overvoltage category 2
Pollution degree 2
DC-Output static
Load regulation CV ≤0.05% FS (0 - 100% load, constant input voltage and constant temperature)
Line regulation CV ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature)
Stability CV ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature)
Temperature coefficient CV ≤30ppm/°C (Following 30 minutes warm up)
Compensation (Remote Sense) ≤5% UNominal
Load regulation CC ≤0.1% FS (0 - 100% load, constant input voltage and constant temperature)
Line regulation CC ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature)
Stability CC ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature)
Temperature coefficient CC ≤50ppm/°C (Following 30 minutes warm up)
Load regulation CP ≤0.3% FS (0 - 100% load, constant input voltage and constant temperature)
Load regulation CR ≤0.3% FS + 0.1% FS current (0 - 100% load, constant input voltage and constant temperature)
Protective functions
OVP Overvoltage protection adjustable, 0 - 110% UNominal
OCP Overcurrent protection adjustable, 0 - 110% INominal
OPP Overpower protection adjustable, 0 - 110% PNominal
OT Overtemperature protection, output shuts down in case of insufficient cooling
DC-Output dynamic
Rise time 10 - 90% CV ≤20 ms
Fall time 90 - 10% CV ≤20 ms
Rise time 10 - 90% CC ≤10 ms
Fall time 90 - 10% CC ≤10 ms
Display accuracy
Voltage ≤0.05% FS
Current ≤0.1% FS
Insulation
AC-Input to DC-Output 3750 Vrms (1 Minute), creepage >8 mm
AC-Input to case (PE) 2500 Vrms
DC-Output to case (PE) Depending on the model, see model table
DC-Output to Interfaces 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output)
Interfaces Digital
USB, Ethernet (100 MBit) for communication
Built-in, galvanically isolated
1x USB Host for data acquisition
Optional, galvanically isolated CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet
Interfaces Analog
Built-in, galvanically isolated 15-pole D-Sub
Signal range 0 - 10 V or 0 - 5 V (switchable)
Inputs U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off
Outputs Monitor U and I, alarms, reference voltage, status DC, status CV/CC
Accuracy U / I / P / R 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4%
Device configuration
Parallel operation Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


General specifications
Safety and EMC
EN 61010-1
IEC 61010-1
Safety UL 61010-1
CSA C22.2 No 61010-1
BS EN 61010-1
EN 55011, class B
CISPR 11, class B
FCC 47 CFR Part 15B, Unintentional Radiator, class B
EN 61326-1 include tests according to:
EMC - EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6
Safety protection class 1
Ingress Protection IP20
Environmental conditions
Operating temperature 0 - 50 °C
Storage temperature -20 - 70 °C
Humidity ≤80% RH, non-condensing
Altitude ≤2000 m (≤6600 ft)
Mechanical construction
Cooling Forced air flow from front to rear, temperature controlled fans
Dimensions (B x H x T) 19“ x 2U x 462 mm (Enclosure only, not over all)
Weight 9,5 kg (21 Lbs) 1500 W unit 12,7 kg (28 Lbs) 3000 W unit

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


Technical Specifications PSB 10010-60 PSB 10060-60 PSB 10080-60 PSB 10200-25 PSB 10360-15
DC-Output
Voltage range 0 - 10 V 0 - 60 V 0 - 80 V 0 -200 V 0 - 360 V
Ripple rms CV 10 mV BW 300 kHz 10 mV BW 300 kHz 10 mV BW 300 kHz 30 mV BW 300 kHz 30 mV BW 300 kHz
Ripple and noise p-p CV 100 mV BW 20 MHz 100 mV BW 20 MHz 100 mV BW 20 MHz 300 mV BW 20 MHz 300 mV BW 20 MHz
UMin for IMax (Sink) 0.8 V 0.8 V 0.8 V 2V 2V
Current range 0 - 60 A 0 - 60 A 0 - 60 A 0 - 25 A 0 - 15 A
Power range *1 0 - 600 W 0 - 1500 W (0 - 1200 W) 0 - 1500 W (0 - 1200 W) 0 - 1500 W (0 - 1200 W) 0 - 1500 W (0 - 1200 W)
Resistance range 0.04 Ω - 80 Ω 0.04 Ω - 80 Ω 0.04 Ω - 80 Ω 0.25 Ω - 500 Ω 0.8 Ω - 1600 Ω
Output capacity 8640 μF 8640 μF 8640 μF 800 μF 330 μF
Efficiency up to 93.0% *2 94.0% *2 94.0% *2 94.5% *2 94.5% *2
Isolation
Negative DC-Pol <-> PE ±1000 V DC ±1000 V DC ±1000 V DC ±1000 V DC ±1000 V DC
Positive DC-Pol <-> PE +1000 V DC +1000 V DC +1000 V DC +1000 V DC +1000 V DC
Article number 30000734 30000720 30000721 30000722 30000723

*1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid
*2 100% Power and 100% Output voltage

Technical Specifications PSB 10500-10 PSB 10750-06


DC-Output
Voltage range 0 - 500 V 0 - 750 V
Ripple rms CV 40 mV BW 300 kHz 50 mV BW 300 kHz
Ripple and noise p-p CV 500 mV BW 20 MHz 500 mV BW 20 MHz
UMin for IMax (Sink) 2.5 V 2.5 V
Current range 0 - 10 A 0-6A
Power range *1 0 - 1500 W (0 - 1200 W) 0 - 1500 W (0 - 1200 W)
Resistance range 2 Ω - 3000 Ω 4 Ω - 6000 Ω
Output capacity 120 μF 40 μF
Efficiency up to 95.0% *2 95.0% *2
Isolation
Negative DC-Pol <-> PE ±1500 V DC ±1500 V DC
Positive DC-Pol <-> PE +2000 V DC +2000 V DC
Article number 30000724 30000725

*1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid
*2 100% Power and 100% Output voltage

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


Technical Specifications PSB 10010-120 PSB 10060-120 PSB 10080-120 PSB 10200-50 PSB 10360-30
DC-Output
Voltage range 0 - 10 V 0 - 60 V 0 - 80 V 0 -200 V 0 - 360 V
Ripple rms CV 10 mV BW 300 kHz 10 mV BW 300 kHz 10 mV BW 300 kHz 30 mV BW 300 kHz 30 mV BW 300 kHz
Ripple and noise p-p CV 100 mV BW 20 MHz 100 mV BW 20 MHz 100 mV BW 20 MHz 300 mV BW 20 MHz 300 mV BW 20 MHz
UMin for IMax (Sink) 0.8 V 0.8 V 0.8 V 2V 2V
Current range 0 - 120 A 0 - 120 A 0 - 120 A 0 - 50 A 0 - 30 A
Power range *1 0 - 1200 W 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W)
Resistance range 0.02 Ω - 24 Ω 0.02 Ω - 24 Ω 0.02 Ω - 40 Ω 0.1 Ω - 250 Ω 0.4 Ω -800 Ω
Output capacity 17280 μF 17280 μF 17280 μF 1600 μF 660 μF
Efficiency up to 93.0% *2 94.0% *2 94.0% *2 94.5% *2 94.5% *2
Isolation
Negative DC-Pol <-> PE ±1000 V DC ±1000 V DC ±1000 V DC ±1000 V DC ±1000 V DC
Positive DC-Pol <-> PE +1000 V DC +1000 V DC +1000 V DC +1000 V DC +1000 V DC
Article number 30000735 30000726 30000727 30000728 30000729

*1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid
*2 100% Power and 100% Output voltage

Technical Specifications PSB 10500-20 PSB 10750-12 PSB 11000-10 PSB 11500-06
DC-Output
Voltage range 0 - 500 V 0 - 750 V 0 - 1000 V 0 - 1500 V
Ripple rms CV 40 mV BW 300 kHz 50 mV BW 300 kHz 100 mV BW 300 kHz 150 mV BW 300 kHz
Ripple and noise p-p CV 500 mV BW 20 MHz 500 mV BW 20 MHz 2000 mV BW 20 MHz 6500 mV BW 20 MHz
UMin for IMax (Sink) 2.5 V 2.5 V 4V 4.2 V
Current range 0 - 20 A 0 - 12 A 0 - 10 A 0-6A
Power range *1 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W) 0 - 3000 W (0 - 1500 W)
Resistance range 1 Ω - 1500 Ω 2 Ω - 3000 Ω 3 Ω - 6000 Ω 8 Ω -6000 Ω
Output capacity 240 μF 80 μF 60 μF 20 μF
Efficiency up to 95.0% *2 95.0% *2 95.0% *2 95.0% *2
Isolation
Negative DC-Pol <-> PE ±1500 V DC ±1500 V DC ±1500 V DC ±1500 V DC
Positive DC-Pol <-> PE +2000 V DC +2000 V DC +2000 V DC +2000 V DC
Article number 30000730 30000731 30000732 30000733

*1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid
*2 100% Power and 100% Output voltage

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


General AC Connection
The bidirectional DC laboratory power supplies in the PSB The bidirectional DC power supplies in the PSB 10000 se-
10000 series from EA Elektro-Automatik are two quadrant ries are equipped with an active PFC which provides a high
devices which can perform the function of power supply as efficiency at a low energy consumption. Furthermore, the
well as that of an electronic load. In load mode the device devices in this series provide a wide input voltage range.
is regenerative and feeds the energy back into the local grid This extends from 1-phase 110/120 V up to 240 V AC mains
with an efficiency up to over 96%. The PSB 10000 series supply and 3-phase 208 V to 380 V, 400 V and 480 V AC
includes single and three phase units, which, together with mains supply. The devices can be operated in the majority
the wide input range, allows use with practically all global of global mains supply. They adjust automatically, without
mains voltages. The DC voltage and current are directed by additional configuration, to the available supply. In a 110/120
the application and the spectrum ranges from 0 - 10 V to V and 208 V AC grid a derating of the output power is set.
0 - 2000 V and from 0 - 6 A up to 0 - 1000 A in a single de-
vice. The DC supply operates as a flexible output stage with Energy recovering
a constant power characteristic (autoranging), and a wide The energy consumed in load mode is feed back into the
voltage, current and power range. To achieve higher power connected mains supply with an efficiency of over 96 %.
and current all units are equipped with a master-slave bus. This reduces cost: as the energy is not converted to heat as
This enables up to 64 parallel connected devices to be com- in other loads, the energy costs are reduced. In addition, the
bined into one system which can provide up to 1920 W and devices generate less heat requiring less cost intensive air
64000 A. Such a system works as a single unit and can use conditioning. One device is sufficient for the whole applica-
different power classes, only the voltage class must remain tion, reducing investment and installation costs.
constant. In this way a user can construct a 75 kW sys-
tem from two 30 kW and one 15 kW devices from the PSB
10000 range. Furthermore, typical laboratory functionality
is provided. This includes an extensive function generator,
alarm and warning management, assorted interfaces and
ports, software solutions and many more functions.

The principle of Energy recovering


This demonstrates, based on an application, how a ‘device
under test’ takes energy from the mains, converts it to DC
and feeds that into an EA device. The bidirectional power
supply PSB 10000 converts this energy back into an AC cur-
rent and feeds it back into the mains..

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


DC Output DC Connection
The output of the bidirectional power supply PSB 10000 Connection of the DC output is via a copper rail on the back
with a DC voltage of 0 - 10 V up to 0 - 2000 V allows positive side of the device. If a system with higher performance is
and negative currents of 0 - 6 A up to 0 - 1000 A as a two- required, the devices are simply connected in parallel. With
quadrant device. The flexible output stages (autoranging) minimal effort devices can be linked with the vertical cop-
provide the user with a wide voltage, current and power ran- per rails. A cover for contact protection is provided.
ge and hence a wider field of working than traditional power
supplies.

The principle of autoranging


This description should clarify the availability the voltage
and current ranges within the power hyperbole.

Function generator Interfaces


All models in the PSB 10000 series are equipped with a As standard EA devices are fitted with the most important
function generator. This allows curve processes such as digital and analogue interfaces and ports which are galva-
sine, triangle, square or trapeze to be simply called up. A nically isolated. These include an analogue interface which
ramp function and a arbitrary generator allow voltage can be parameterised for input and output, control and mo-
and current progression to be freely programmable. Test nitoring, of 0 - 5 V or 0 - 10 V for voltage, current, power and
sequences for repeated tests can be saved and reloaded resistance, assorted inputs and outputs as well as USB and
when needed, that´s saving time. A LUT allows IU and UI ethernet ports. The following options which use a Plug &
reference lines to be stored. For simulation of a photovoltaic Play slot, complete the portfolio:
system or fuel cells, adaptable tables are provided. With the - CAN
standard PV characteristic curve (DIN EN 50530) various - CANopen
solar cells and many other technology parameters can be - RS232
selected and set. In short, the user is supported by a multi-
- Profibus
tude of useful functions.
- EtherCAT
- Profinet, with one or two ports
- Modbus, with one or two ports
- Ethernet, with one or two ports

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


High performance systems Master-Slave-Bus and Share-Bus
High power applications can be covered with high power If the integral master-slave bus and share bus are used, a
systems of up to 1920 kW. These are achieved by using the multi device system behaves as a single device. The master-
outputs of many PSB 10000 devices, changing the copper slave bus and the share bus are simply connected to each
rails to vertical, and connecting in parallel. Thus, a 19” cabi- device. With the master-slave bus the system data such as
net with 42 HE can provide a system with 240 kW occupy- total power and total current are collected and shown in the
ing 0.6 m² floorspace. The master/slave bus enables up to master device. Warnings and alarms of the slave devices
8 cabinets with a maximum of 64 units of 30 kW each to are shown clearly in the display. The share bus provides an
behave as one unit. equal load distribution to the individual devices.

Example representation
In this illustration you can see a fully assembled and wired
240 kW system

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


Application
Battery test for electro mobility On-board charger test
A typical application for the bidirectional power supplies In an on-board charger test (OBC) the electrical features
from EA Elektro-Automatik is the testing of the electrical must be tested under various conditions. This requires a
characteristics of a battery. The wide application spectrum flexible test system which also provides test data. With the
covers cell, module or pack tests, the determination of the sequencing and logging functions of the PSB 10000 devi-
SOH (State-of-Health) for a second life classification as well ces test procedures allow data to be read out and saved. In
as the End-of-Line (EOL) test. These applications put many this way applications can promptly generate reproducible
demands on power electronics which are fulfilled by the test results based on dynamic and highly accurate set point
PSB 10000 range. The excellent features of this device ran- and measurement data. To avoid competition between two
ge are: measurement of voltage and current with the requi- separate control loops of the device under test (DUT) and
red accuracy and dynamism, reproducibility and reliability the test device, the control frequency of the power supply
of these data and the economic and flexible usage. Whether is adjustable. The modes Normal, Fast and Slow allow the
in an automated test system or in an integrated battery test, PSB 10000 devices to match the control characteristics of
all possibilities are open to the user. Furthermore, the de- the on board charger.
vices are clearly economic with efficiencies of 96% or more.
Solar array simulation
Battery simulation The programmable power supplies of the PSB 10000 range
Additional applications include the simulation of batteries are highly suited to use as test systems for PV inverters as
as single cells, modules, or packs. These simulations aid in they can provide the necessary simulation for solar cells.
the optimal configuration of energy storage as well as the Users can readily program simulation models according to
components to be supplied. Wherever reproducible data are EN 50530 or Sandia using diverse solar cell materials. An
needed a battery simulator is the first choice. Also, the use IU curve can be accurately reproduced, parameters such as
of a simulator as a power source provides protection for the irradiation, shadow, temperature, clouds, and rain can be in-
connected consuming component. The Over-Current-Pro- cluded. Thus, the devices can test all the relevant electrical
tection (OCP) can, like a safety fuse, switch off the output features of a PV inverter including the particularly import-
and generate an alarm. The voltage can be monitored and ant determination of the efficiency. Users can select a static
can, if over or under limits, trigger various functions, and or dynamic Maximum-Power-Point-Tracking (MPPT). The
also generate warnings and alarms. Thus, many integrated high resolution of 16-bit technology and a sampling rate
functions can be safely performed. of 1µs enables the programmable power supply to deliver
exact results which can be documented and saved to an
Fuel cell test Excel file.
The devices in the PSB 10000 range may be used for tes-
ting the electrical features of fuel cells, fuel cell stacks and Battery recycling
fuel cell systems. Here they generate highly accurate and The bidirectional power supplies of the PSB 10000 range
reproducible results in all electrical modes. To test the re- enable retired batteries from electric vehicles to be consi-
sistance, performance, and active life of a fuel cell quickly dered for a possible further use. Assessment of the battery
and economically users can readily incorporate the devices pack starts with a State of Health (SOH) check to determine
into an automatic test system. The feedback capability gua- if a second life is feasible. This standard integral function
rantees high level of energy and cost efficiency. If higher can be initiated by press button. If this check shows too litt-
currents are needed for testing a complete fuel cell system, le rest capacity, then the battery must be fully discharged
then multiple devices can be connected in parallel in a mas- before recycling. The autoranging of the devices guaran-
ter-slave system. Here high accuracy and dynamism are tees the maximum possible total discharge though the high
maintained. load current, even with voltages under 2 V. The mains feed-
back of the power grid consumed of 96% efficiency makes
this process highly cost effective.

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


Technical Drawing PSB 10000 2U

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en


Front Panel Description PSB 10000 2U

1. Main switch
2. TFT Control Interface, interactive operation and display
3. Rotary knob with push-button for settings and control
4. USB Host, use USB-stick for data logging and sequencing
5. Rotary knob with push-button for settings and control
6. On / Off push-button with LED status display

Rear Panel Description PSB 10000 2U

1. Slot for Interfaces


2. Master-Slave-Bus interface to set up a system for parallel connection
3. Share-Bus Interface to set up a system for parallel connection
4. Output voltage Remote Sense input terminal
5. Output terminal, Copper busbar
6. Mains input terminal
7. Ethernet interface
8. USB interface
9. Connector (DB15 Female) for isolated analog program, monitor and other functions
10. Grounding connection screw (PE)

© EA Elektro-Automatik in 2021, Errors and changes excepted Datasheet_PSB_10000_2U_3kW_en

You might also like