Vickers Eaton
Vickers Eaton
Vickers Eaton
Technical Catalog
PVX
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Code
Form Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Basic Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
No Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DF Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DQ Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
HG Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
FE Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Special Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Combination Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Examples for Combination units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Pump Specifications
US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Performance Curves
Performance Curves, Outlet Flow & Inlet Power, Shaft Input Power, 066 to 250 Series . . . . . . . . . 21
Operating Data: Theoretical Bearing Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Operating Data: Typical Drain Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Controls
DF, LR Pressure Compensator/Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DQ Mooring Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FE, HG Manual Displacement Adj. Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Electric Motor Displacement Control ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Pressure Signal Displacement Control DP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Proportional Valve Displacement Control SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Table of Contents
(cont.)
Pump Dimensions *
PFXS 066. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
PFXS 090. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
PFXS 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
PFXS 180. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PFXS 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
PVXS 066 - 250 DF, Two Stage Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
PVXS 066 - 250 DF, with Load Sensing Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
PVXS 066 - 250 LR, with Pressure Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
PVXS 066 - 250 ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PVXS 066 - 250 DP, with Prop. Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PVXS 066 - 250 SP, with Prop. Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Thru - drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Splined Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
SAE4 - Bolt Mounting, Installation Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Application Data
Fluid Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 3
Introduction
• Axial piston pumps • Oversize shafts and • "Building block" design AVAILABLE DISPLACEMENT
SIZES
with swashplate bearings. gives these pumps a
design for reliable wide range of 66 ccm
• Rotating and pressure
operation and long life. application. 90 ccm
loaded parts are
• Pressure up to 420 pressure balanced. • Fast response times. 130 ccm
bar. Rated speed up 180 ccm
• Integrated pilot pump,
to 1800 min-1. Higher filter and pressure AVAILABLE REPLACEMENT
speeds possible. relief valves available. UNIT DISPLACEMENT SIZES
250 ccm
4 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Fixed & Variable
Displacement Pumps
"X" Series
Form Page
The following 48-digit coding system has been Some characters are already filled out on the
developed to identify all of the configuration options following pages. For such characters there is
for the "X" series (Open Loop) fixed and variable no option available.
displacement pumps. Use this model code to
specify a unit with the desired features. All 48-digits Explanation for each character can be found
must be present when ordering. You may want to as follows:
photocopy the matrix below to ensure that each CHARACTER PAGE
number is entered in the correct box. If adjustments Basic Pump Model Code 1...23 6
other than the standard setting (character 40 ... 43)
Control Options 24...39 7 - 15
or special features (character 44 ... 48) are needed,
Customer Adjustment Specification 40...43 7 - 15
please provide the information when ordering.
Special Features 44...46 16
Design Number 47...48 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
P X – M 1 S V A
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
1 0
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 5
Model Code
Open Loop Pumps
P * X * — * * * M * * * * * * 1 * * * S V * A #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
ISO 3019/2-125A2HW • •
ISO 3019/2-160A2HW • •
ISO 3019/2-200A2HW •
Right Hand • • • • •
Left Hand • • • •
SAE A • • • • •
SAE B • • •
6 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps
0 0 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
24 25 Control Type 30 Extra Functions 35 Pilot Oil Filter 38 Electric Motor Type
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 7
Model Code
Open Loop Pumps
D F 0 0 0 A * * 0 0 0 0 * 0 0 * * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
8 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps
D Q 0 0 0 C 0 * 0 0 0 0 * 0 0 * * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 9
Model Code
Open Loop Pumps
L R 0 0 0 A * * * * * 0 * 0 0 * * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
10 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps
E S * 0 0 A 0 * 0 0 0 0 0 * * 0 * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
ES – Electric Motor A – Single Side of Center “A” 0 – Not Applicable Adjustment Specification
Displacement 0000 – None
30 Extra Functions 37 Position Monitoring ???? – Yes (final number will
26 Displacement be assigned by Eaton.
0 – Not Required A –4 Limit Switches
Adjustment Options B – 8 Limit Switches Specify on table
M – Electric Motor - 31 Pressure Control P – 4 Limit Switches below)
Fast Response* Options w/Sensor
44 Special Features
N – Electric Motor - 0 – Not Applicable T – 8 Limit Switches
Medium Response* w/Sensor Add special feature
P – Electric Motor - 32 33 34 Power Control description (characters
Slow Response* 38 Electric Motor Type 44...46) on page 16 if
000 – Not Applicable
2 – Motor With Brake (IP-54) required.
27 28 Electronic Controls 35 Pilot Oil Filter 3 – Motor Without Brake
00 – Not Required 0 – Not Applicable (Explosion Proof)
39 Control Voltage of
Venting Valve
0 – Not Applicable
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 11
Model Code
Open Loop Pumps
H G 0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
24 25 Control Type 29 Yoke Displacement Zone 35 Pilot Oil Filter 39 Control Voltage of
12 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps
F E 0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
00 – Not Required 000 – Not Applicable 39 Control Voltage of Add special feature
Venting Valve description (characters
29 Yoke Displacement Zone 35 Pilot Oil Filter
0 – Not Applicable 44...46) on page 16 if
A – Single Side of Center “A” 0 – Not Applicable required.
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 13
Model Code
Open Loop Pumps
D P * 0 0 A 0 0 0 0 0 * 0 0 0 0 * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
24 25 Control Type 29 Yoke Displacement Zone 35 Pilot Oil Filter 39 Control Voltage of
DP – Pressure Signal A – Single Side of Center “A” 0 – Not Applicable Venting Valve
Adjustment V – Filter with Visual 0 – Not Applicable
Displacement Control 30 Extra Functions Indicator
E – Filter with Electrical 40 41 42 43 Customer
0 – Not Required
26 Displacement Indicator Adjustment Specification
Adjustment Options 31 Pressure Control 0000 – None
36 Venting Valve
G – Mounting Interface Options ???? – Yes (final number will
CETOP 3 Only 0 – Not Applicable 0 – Not Applicable be assigned by Eaton.
H – Remote Port G 1/4 Specify on table
J – Proportional Relief Inc. 32 33 34 37 Position Monitoring
Power Control below)
Electronics 000 – Not Applicable 0 – No Position Monitoring
44 Special Features
27 28 Electronic Controls 38 Electric Motor Type Add special feature
00 – Not Required 0 – No Electric Motor description (characters
44...46) on page 16 if
required.
14 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps
S P * * * A 0 0 0 0 0 * 0 0 0 0 * * * * #
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 15
Model Code
Open Loop Pumps
* * * 1 0
44 45 46 47 48
44 45 46 Special Features
000 – None
*** – Defined by Eaton
47 48 Design Number
10 – Design Number
16 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Combination Units
* * * C — * * * * * * * * * * * * * * * * * * * *
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
H C 8 1 * * * * * * * * * *
26 27 28 29 30 31 32 33 34 35 36 37 38 39
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 17
Model Code
Examples for
Combination Units
Example 1: Combination
of two open loop pumps
Model Code Front Unit PVWF-500M08R0001R02SVMASPC03A0000000000000000010
Model Code Rear Unit PVXR-250M07R0001R02SVMASPC03A0000000000000000010
Model Code Combination Unit PVWC-500SP250SP0000000000HC81**********
Example 2: Combination
of one closed loop - and
two open loop pumps
(For other product
model codes refer to the
according catalog)
Mode Code Front Unit TVWF-500M08R0000H1R02SVMA20SPC03C00000000E000H000000010
Model Code Middle Unit PVWM-250M07R0001R02SV0ADF000A0000000000000000010
Model Code Rear Unit PFXR-130M02R00P1A02SV0A00000A0000000000000000010
Model Code Combination Unit TVWC-500SP250DF1300000000HC81**********
18 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Specifications -
US
HYDRAULIC CHARACTERISTICS
DRIVE
Maximum driving torque - single unit M1 Single lb.ft. 325 444 640 887 1233
(p2 max., = 100%)
Maximum power consumption - single unit P1 Single hp 93 126 182 254 355
(p2 max., = 100%; n= 1800 rpm)
Maximum driving torque limited to M1 Comb. lb.ft. 2x325 2x444 2x640 2x887 2x1233
splined shaft only - comb. unit
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 19
Pump
Specifications -
Metric
HYDRAULIC CHARACTERISTICS
DRIVE
Maximum driving torque - single unit M1 Single Nm 440 600 868 1202 1671
(p2 max., = 100%)
Maximum power consumption - single unit P1 Single kW 69 94 136 189 265
(p2 max., = 100%; n= 1800 min-1)
Maximum driving torque limited to M1 Comb. Nm 2x440 2x600 2x868 2x1202 2x1671
splined shaft only - comb. unit
20 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Performance
Curves -
066, 090, 130,
180, 250 Series
hp
kW 350 vol.
250 tot.
100
300 tot for 100 % Vg
L/min PFX/PVX 90
USgpm 400 tot for 50 % Vg
200
250 80
100 250
tot for 25 % Vg
Theoretical Power Consumption P
70
80 300 150 200
180 60
Efficiency (%)
Effective Outlet Flow
50
60 150
200 100
40
130
40 100
30
90
100 50 20
20 066 50
10
0 0 0 0
0 100 200 300 400 bar 0 100 200 300 400 bar
0 1000 3000 5000 5800 psi 0 1000 2000 3000 4000 5000 5800 psi
Operating Pressure Operating Pressure
Typical at 1500 min-1 with anti-wear oil at 40 cSt For Calculation: Peff = Pth/ tot
Single displacement pumps: PFX,PVX
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 21
Performance Pump size 066
Curves - 10 5
Operating Data:
Theoretical Bearing Life Time
1500 min -1
1800 min -1
10 4
3
3 x 10
bar 50 100 200 300 400
At maximum displacement
and various speeds. psi 725 1450 2900 4350 5800
Operating Pressure
-1
Basic Rating Life L10 [h]
-1 1000 min
1000 min
Basic Rating Life L10 [h]
-1
1500 min
-1
1500 min 1800 min -1
1800 min -1
10 4 10 4
3 3
3 x 10 3 x 10
bar 50 100 200 300 400 bar 50 100 200 300 400
psi 725 1450 2900 4350 5800 psi 725 1450 2900 4350 5800
Operating Pressure Operating Pressure
-1 -1
1000 min 1000 min
3
3 x 10 3 x 10 3
bar 50 100 200 300 400 bar 50 100 200 300 400
psi 725 1450 2900 4350 5800 psi 725 1450 2900 4350 5800
Operating Pressure Operating Pressure
22 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Performance
Curves -
Operating Data:
Typical Drain Flow from an
Open-Loop Pump Based on USgpm L/min PFX/PVX180
1500 r/min and 35cSt
16
4.0 15
14
3.5 13
USgpm L/min PFX/PVX066/090 3
12
3.0 11 3.0
11
10 2
10
2.5 2.5
9 3 9
8 1
8
2.0 7 2.0
Drain Flow
7
6 2
1.5 6
5 1.5
1 5
4 4
1.0 1.0
3 3
2 2
0.5 0.5
1 1
0 0 0 0
0 100 200 300 bar 0 100 200 300 bar
0 1000 2000 3000 4000 5000 psi 0 1000 2000 3000 4000 5000 psi
Operating Pressure Operating Pressure
USgpm L/min
USgpm L/min
4.0 PFX/PVX130 4.0
PFX/PVX250
14 14
3.5 13 3.5 13
3 3
12 12
3.0 3.0
11 11
2 2
10 10
2.5 2.5
9 9
1
8 8
2.0 2.0
7 7
1
6 6
1.5 1.5
5 5
4 4
1.0 1.0
3 3
0.5 2 0.5 2
1 1
0 0 0 0
0 100 200 300 bar 0 100 200 300 bar
0 1000 2000 3000 4000 5000 psi 0 1000 2000 3000 4000 5000 psi
Operating Pressure Operating Pressure
1 PFX and PVX models at 2 PVX in pressure cutoff 3 PVX in pressure cutoff
maximum displacement (PVX mode (flow of pilot stage is mode (flow of pilot stage is
models with type FE, HG or discharged separately) discharged in case)
ES controls i.e. no control oil
flow)
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 23
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump
Energy saving hydraulic LR The p/Q variations see the model or 6 in combination with
drives are possible with characteristic curve coding and circuit customer adjustment
pressure compensated is a hyperbola. For diagrams. The maximum specifications position
and/or power controlled constant speed the drive flow of the pump can be 40-43 for the set values).
pumps, especially in torque, i.e. the power limited mechanically to This solution is also
combination with the used, is held constant. between 50% and 100% recommended for
load-sensing option. The power hyperbola can by screw. very rough operating
DF The system pressure be continuously adjusted As an additional option conditions and the
remains constant for between Pmin and the maximum (or need of a very exact
the entire volume flow Pmax. Pmin is given by minimum) flow can also repeatability over a long
rate. System pressure the minimum set value be limited by a spacer time period. The setting
can be set either of control’s main stage inside the control must be defined before
manually, hydraulically (app. 20 bar) and power cylinder (position ordering and cannot
or electronically. The loss of the pump. number 13 in be modified during
standard Hydrokraft Both controllers can be model coding, operation.
pressure compensator combined with another options 4, 5
066/090
0
0 100 200 300 400 bar
250
130/180
Pressure compensator response times
Up Down
Outlet 066/090
pressure 50
p2
Tu
Swashplate
yoke angle Tu Tg Tg
y 0,9 y max.
0
0 100 200 300 400 bar
T u= time lag t
T g= compensating time
2000 4000 6000 psi
Operating Pressure
24 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump
DF Pressure compensator
DF000A ...
Control valve adjustable
mechanically, electrically Alternatively
or remote port only
Mechanical Electrical Remote port
X1 adjustment adjustment only
+Q
Minimum pressure
Qmax approximately 20 bar (280 psi)
A B p
Qmax
A B p
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 25
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump
p
Qmax
A B
X1 Alternatively
X2
Mechanical Electrical Remote port
adjustment adjustment only +Q
Qmax
A B p
26 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DQ Mooring
Control
“X” Series - Open loop pump
The DQ-control is a The DQ-control is only As an additional option This solution is also
pressure control with available for sizes 66, (90 the maximum (or recommended for
overcenter operation on request), 130 and 180 minimum) flow can be very rough operating
(2 quadrants). It can ccm/rev. limited by a spacer conditions and the
be used eg. for Like the standard inside the control need of a very exact
counterbalanced Hydrokraft pressure cylinder (position repeatability over a long
systems or applications compensator this control number. 13 in model time period. The setting
where reverse flow pilot operated and very coding, options 4, 5 or 6 must be defined before
from the system can stable. For performance in combination with ordering and cannot
drive the pump in data/response time customer adjustment be modified during
reverse (negative please refer to the specifications position operation.
pump angle) such DF-control. 40-43 for the set values).
as a hydraulic motor.
Alternatively
Mechanical Electrical Remote port
X1 adjustment adjustment only
Minimum pressure
approximately 20 bar (280psi)
+Q
Qmax
A B
-Q
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 27
Controls -
HG Manual
Adjustment
Displacement
Control FE
“X” Series - Open loop pump
+V
0 to + Vmax
displacement
28 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Electric Motor
Displacement
Control ES
“X” Series - Open loop pump
M
B
L
PVX Response Times ES - Control
THEORETICAL RESPONSE TIME (SEC) FOR MAX. DISPLACEMENT CHARACTER IN MODEL CODE POS. 26
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 29
Controls -
Pressure Signal
Displacement
Control DP
“X” Series - Open loop pump
The output flow of the The DP-control can be Pressure limiter or customer adjustment
pump is proportional used for steepless flow power limiter override specifications position
to the pilot pressure control with standard not available ( or such 40-43 for the set values).
A separate pilot oil requirements for and other options please This solution is also
circuit is necessary. dynamic and precision. refer to PVW-Series ). recommended for
From this the control No feedback signal As an additional option very rough operating
pressure is reduced to is needed, an optical the maximum (and/or conditions and the
the desired set value indicator recommended minimum) flow can be need of a very exact
by means of a suitable (position 22 in model limited by a spacer repeatability over a long
pressure control valve coding, option “V”). inside the control time period. The setting
(with P -T line ) and A pilot oil filter can be cylinder (position must be defined before
throttle in P - line 0.8 Ø mounted in line between number 13 in model ordering and cannot
(0.03 in). pump and control coding, options 4, 5 or 6 be modified during
(position 35 in model in combination with operation.
coding, option “V” or
“E”).
P T P T A B
M8
D1
P T A B
A pSt T P T A B
100%
Q max
Qmax
S B L
30 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Proportional Valve
Displacement
Control SP
“X” Series - Open loop pump
The SP control operates The proportional As an additional option This solution is also
a hydrostatic drive and valve and servo piston the maximum (and/or recommended for
works without throttle transform the output minimum) flow can be very rough operating
losses within electrically signal of the control card limited by a spacer conditions and the
adjustable limits. This to the desired setting. inside the control need of a very exact
is done by controlling This results in a very cylinder (position repeatability over a long
delivery flow with precise and dynamic number 13 in model time period. The setting
electrical swashplate control. Pressure limiter coding, options 4, 5 or 6 must be defined before
angle feedback (electr- override available on in combination with ordering and cannot
closed-loop control). request. Power limiter customer adjustment be modified during
All control values are override not available specifications position operation.
recorded as an electrical (for such and other 40-43 for the set values).
signal and lead back options please refer
to the control card. to PVW series).
M St
p St1
P T
Q
A B +100%
0
0 or 10 V
4 20 mA
Electric input signal
A B L1/L2
The ER9.3-10 and ER 9.4-10 ( for High Response ) digital Amplifier cards are optimized for use with the SP-Control. Please ask
for separate Documentation. Software is available for parameter setting and storing (database function). Contact Eaton to
request free of charge manual - and software CD.
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 31
Pump
Dimensions -
PFXS 066
120
246
26
0
Dimensions in mm
68
175 16 210
8 155
L5
L3 right
MB MA M14 cw
Port A
1", 6000psi
154 27.8
A
L1
57.2
68
(25)
W40x1.25x M12-20deep
Ø38 k6
10aDIN 5480 Ø125 h8 L5 Port B
10 h9
58 1 1/2", 3000psi
Center bore
DM12 DIN332 L2 B
69.8
218 56 15 Ø38
(367) M12x25deep
35.7
A System pressure port SAE 1’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 1 1/2‘’, 207 bar (3000 psi) Standard Displacement . . . . . . . . . . . . . . . . . . . . .66 ccm/rev
(L1) Drain port 7/8" – 14 UNF Reduced Displacement Available . . . . . . . . .55 or 44 ccm/rev
(L2) Ventilation port for vertical mounting M26x1.5
(L3) Ventilation port for vertical mounting G1/4 "
(shaft upwards)
(L5) Oil filling plug M26x1.5
(MA) Gauge port system pressure G1/4" DIRECTION OF ROTATION INPUT OUTPUT
32 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 090
Dimensions in mm
120
246
26
0
217.5 68
175 16 210
8 155
L5
L3 right
M10 cw
MB MA
58 4xM10-20deep 120
35 150 (180)
Port A
154 1", 6000psi
A
L1 27.8
68
57.2
W40x1.25x Ø38 k6 (25)
10aDIN 5480
L5 M12-20deep
Ø125 h8 10 h9
Center bore Port B
DM12 DIN332 58
L2 2", 3000psi
B 50
218 56 15
42.88
(367)
(372)
77.7 M12x25deep
A System pressure port SAE 1’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 2‘’, 207 bar (3000 psi) Standard Displacement . . . . . . . . . . . . . . . . . . . . .90 ccm/rev
(L1) Drain port 7/8" – 14 UNF Reduced Displacement Available . . . . . . . . . . . . . .75 ccm/rev
(L2) Ventilation port for vertical mounting M26x1.5
(L3) Ventilation port for vertical mounting G1/4 "
(shaft upwards)
(L5) Oil filling plug M26x1.5
(MA) Gauge port system pressure G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MB) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) Normally plugged Left Hand Rotation A B
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 33
Pump
Dimensions -
PFXS 130
Dimensions in mm
148
316
0
92
20
9
224
L2 L1 L1.1
right
cw
L1 B
200 53.5 -0.2 22
100
Center bore
DM16 DIN332
82
200 4xM12-20deep 150
265 40 185
Port B
50.8
35
A 88.9 Ø63
78
M12-20deep
L1.1 MA
W50x1.25x10a L2 L1 Port A
DIN 5480 Ø50 k6
Ø160 h8 27.8
14 h9
Center bore 68
DM16 DIN332
L1 57.2 Ø25
B
271 120 22
(505) M12-20deep
A System pressure port SAE 1’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 2 1/2‘’, 207 bar (3000 psi) Standard Displacement size 130 ...........................130 ccm/rev
(L1) Drain port M26x1.5 Reduced Displacement Available Size 130...115 or 94 ccm/rev
(L1.1) Oil filling plug 1 1/16”-12UNF
(L2) Ventilation port for vertical mounting G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MA) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) normally plugged Left Hand Rotation A B
34 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 180
Dimensions in mm
316
16
92 148
20
9
224
B
L2 L1 L1.1
right
cw
L1
200 53.5 -0.2 B
22
100
Center bore
DM16 DIN332
82
200 150
4xM12-20deep
265 185
40
Port B
50.8
3
A
88.9 Ø63
78
L1.1 MA
Ø160 h8 L2 L1 M12-20deep
W50x1.25x10a Ø50 k6
DIN 5480 Port A
14 h9 31.8
68
Center bore
DM16 DIN332 L1
A
B Ø32 66.7
271 120 2
(505) M14-20deep
A System pressure port SAE 1 1/4’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 2 1/2‘’, 207 bar (3000 psi) Standard Displacement Size 180 ..........................180 ccm/rev
(L1) Drain port M26x1.5 Reduced Displacement Available Size 180............160 ccm/rev
(L1.1) Oil filling plug 1 1/16”-12UNF
(L2) Ventilation port for vertical mounting G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MA) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) Normally plugged Left Hand Rotation A B
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 35
Pump
Dimensions -
PFXS 250
Dimensions in mm
187
403
0
117
25
10 280
L1
clockwise
L1
250 6 +0.2 26 250 +0.2
B
125
MB Center bore
DM20 DIN332
188 105 4xM16-32deep
330 50 230
Port B
350
69.8
A 120.7 Ø88
MA
90
M16-32deep
L1 L1.1
W62x1.25x10a L2
DIN5480 Ø65 k6 Port A
Ø200 h6 31.8
Center bore 18 h9
80
DM20 DIN332
B 66.7 Ø32
341 164 22
(644) M14-24deep
A System pressure port SAE 1 1/4’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 3 1/2‘’, 35 bar (500 psi) Standard Displacement ........................................250 ccm/rev
(L1) Drain port M26x1.5 Reduced Displacement Available.......222, 208 or 194 ccm/rev
(L1.1) Oil filling plug 1 5/16”-12UN
(L2) Ventilation port for vertical mounting G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MA) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) normally plugged Left Hand Rotation A B
36 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 37
Pump
Dimensions -
PVXS 066 - 250
DF, Two Stage
Pilot Valve
Side ports -
Pressure compensator
DF000A ...
1. Pilot valve (2nd Stage) View X
Port "A"
2. Pressure compensator 6000psi
(1st stage) L19
D11
066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —
38 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B4 L1 L17
X1
B2 L2
L18
L9 orifice
L7 inside
H9 of the
24 control
L6 valve
X1
L1 D5
L1 L1 Size 090
MA D6
H8
H7 B
D12 0 H5
H6 +Vmax
D3
H3 Center bore
DM16 DIN332 L10
L16
B9 L8 L2 L15
B8 L5 M18x1.5-12deep L20
B5 L4 L3
B12
B11
B10 Splined shaft
Dim. See page 51
1
X
2
MA
A
L1 L1
L1
cw L3
H1
D2 k6
H2 H4 +0.2 D4 D1 h8
D13
L1
B7 h9
B3 B Size 090
B6
B1
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 72.5 245.6 245.6 31
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 72.5 245.6 245.6 31
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 50 12 72.5 316 309 33
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 50 12 72.5 316 309 33
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 56 — 72.5 403 403 35
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 39
Pump
Dimensions -
PVXS 066 - 250
DF, with Load
Sensing Valve
Side ports -
Pressure compensator
with Load Sensing
DF000A1 ...
1. Pilot valve (2nd Stage) View X
Port "A"
2. Pressure compensator 6000psi L19
(1st stage)
3. Flow valve
Dimensions in mm
D10 L14
D11
X1 G1/4’’x12,5-deep; option for an additional pilot valve
and/or discharge valve of the pressure compensator
L13
X2 G1/4’’x12,5-deep; load sensing pilot port Port "B"
L1 3000/500psi L11
Two drain ports, one supplied plugged
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed L12 D8
with the shaft input end pointing upwards.
MA G1/4"x12.5-deep gauge port supplied plugged D9
066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —
40 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B4 L1 L17
B2 orifice
L2
L18 inside
of the
L9 control
L7 valves
H9
X1 Size 090
L6
X2
L1 D5
L1 L1
MA D6
H8
B
H7 D12 H5
0
H6 +Vmax
D3
H3 Center bore
DM16 DIN332
L10 L16
B9 L8 L2 D7 L15
B8 L5
M18x1.5-12deep
B5 L4 L3
B12
2 MA
A
3
L1
L1 L1 L3
D2 k6
D1 h8
cw D13
H1 L1
H4 +0.2 D4
H2
B Size 090
B7 h9
B3
B6
B1
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 67.5 245.6 245.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 67.5 245.6 245.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 50 12 67.5 316 306
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 50 12 67.5 316 306
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 56 — 70.5 403 403
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 41
Pump
Dimensions -
PVXS 066 - 250
LR, with Pressure
Limiter
B11
B10
Side ports -
Power Control LR 1
(with pressure limiter)
LR000A2 ... 2
1. Pilot valve (2nd Stage)
2. Pressure compensator
(1st stage) L1 L1
3. Constant power control
cw
Dimensions in mm H1
+0.2 D4
H2 H4
B7 h9
X1 G1/4’’x12,5-deep; option for an additional pilot valve B3
and/or discharge valve of the pressure compensator B6
L1
B1
Two drain ports, one supplied plugged
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
View X
MA G1/4"x12.5-deep gauge port supplied plugged Port "A"
6000psi L19
DIRECTION OF ROTATION CONTROL INPUT OUTPUT Port "B"
Right Hand Rotation To + Vmax B A 3000/500psi
To - Vmax A B
L11
Left Hand Rotation To + Vmax A B
To - Vmax B A
D10 L14
L12 D8
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT D11
3000(500)PSI, INLET 6000PSI, OUTLET KG 2 D9 D2
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
L13
130 2 1/2’’ 1’’ 111 D1
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —
42 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B4 L1 L20
B2 L2 L17 orifice
L18 inside
L9 of the
L7
control
H9 valves
L6
X1 D5 X1
L1
L1
MA D6
H8
B
H7 H5
H6 D12 0
+Vmax
D3 3
H3 Center bore
DM16 DIN332 L10 L16
B9 L8 D7 L15
L5 L2
B8 M18x1.5-12deep Size 090
B5 L4 L3
B12
Splined shaft
Dim. See page 51
X
MA
A
L1
L3
D2 k6
D1 h8 D13
L1
3
B Size 090
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 72.5 245.6 245.6 161
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 72.5 245.6 245.6 161
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 60 12 72.5 316 306 171
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 60 12 72.5 316 306 171
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 112 — 75.5 403 403 199.5
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 43
Pump
Dimensions -
PVXS 066 - 250
ES
Side ports -
Electric Motor
Displacement Control
ES*00A ...
Dimensions in mm
B4
L1 Two drain ports, one supplied plugged B2
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
MA G1/4"x12.5-deep gauge port supplied plugged
D14
L1
H8
DIRECTION OF ROTATION CONTROL INPUT OUTPUT H7
L1
Right Hand Rotation To + Vmax B A
To - Vmax A B D12
H6 MA D3
Left Hand Rotation To + Vmax A B
To - Vmax B A
H3 Center bore
DM16 DIN332
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 210 116 160 235 130 180 10 116 58 276.5 334.5 —
090 210 116 160 235 130 180 10 116 58 276.5 334.5 157.5
130 260 140 200 265 224 224 14 140 70 288.5 368.5 —
180 260 140 200 265 224 224 14 140 70 288.5 368.5 —
250 325 180 250 330 280 280 18 175 87.5 332.7 434.7 —
44 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L1 L16 B11
L2 L15 B10
L17
L9
L7
L6
D14
L1 D5
L1
D6
H7 L1
B cw
H5
0 H1
A D3 +Vmax
H4+0.2
H2
D4
Center bore
DM16 DIN332 L10
L8 L2 D7 B7 h9
L5 Size 090
M18x1.5-12deep B3
L4 L3 B6
Splined shaft B1
Dim. See page 51
L18
X
View X
Port "A"
6000psi
MA
A
D L
L1
D11
L3
D2 k6
D1 h8 L13
D13 Port "B" L11
3000/500psi
L1
L12 D8
B Size 090
D9
SIZE H1 H2 H3 H4 H5 H6 H7 H8
+0.2
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 78 153.5 7245.6 245.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 78 153.5 245.6 245.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 100 175.5 316 306
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 100 175.5 316 306
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 88 163.5 403 403
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 45
Pump
Dimensions -
PVXS 066 - 250
X SSt
MA
A
Side ports - L1
Pressure Signal
Displacement Control L3 PSt1 T
DP*00A ... D2 k6
1. Pressure proportional valve D1 h8
D13
2. Pressure limiter
L1
Dimensions in mm
B
Size 090 L12
T G1/2’’ Tank port
SSt G3/4’’ Suction port of pilot pump
PSt G3/4’’ Port of pilot pressure
PSt1 Port of pilot pressure Size 006/090=M14x1.5 Splined shaft
Size 130/180=M16x1.5 Dim. See page 51
Size 250=G1/2’’(M22x1.5)
B4
L1 Two drain ports, one supplied plugged B2
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed 1
with the shaft input end pointing upwards. H9
MA G1/4"x12.5-deep gauge port supplied plugged
2
46 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pilot pump View X
Port "A" B11
6000psi L19 B10
SSt
D10 L14
L1 L1
D11
T cw
L13 H1
H4 +0.2 D4
Port "B" H2
3000/500psi
L11
B7 h9
L12 B3
D8 B6
B1
Splined shaft
D9
Dim. See page 51
L15
L1 L16
L2
L22 L17
L18
L9 Cetop NG6
L7 DIN24340
PSt1
T
L6
L1 D5
D6 D14
MA
B
H5
+Vmax
PSt
D3
3
L10 H10
Center bore L8
DM16 DIN332 L5 L2 L20
Pilot pump View X
M18x1.5-12deep Size 090 L21
L4 L3 Port "A"
6000psi
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11
+0.2
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L22
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 267 104 46 245.6 245.6 73.5 122.6 230.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 267 104 46 245.6 245.6 73.5 122.6 230.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 342 128 46 316 306 73.5 122.6 336
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 342 128 46 316 306 73.5 122.6 336
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 387 150 46 403 403 73.5 122.6 437
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 47
Pump
Dimensions -
PVXS 066 - 250
B2
Side ports - 1
Proportional Valve
Displacement Control
3
SPC03A.....E...
1. Proportional valve
2. Pressure limiter 2
3. Filter L1 L1
cw
Dimensions in mm H1
D4 H2
T G1/2” H3
Pst G1/2”
Mst G1/4” B3
B6
L1 Two drain ports, one supplied plugged B1
L2 B13
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
Port "A" Port "B"
MA G1/4"x12.5-deep gauge port supplied plugged
0
L14 D10 L12 D8
D11 D9
DIRECTION OF ROTATION CONTROL INPUT OUTPUT 0
L13 L11
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
48 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L16
L15 Prop. Valve
L1 Filter with
electr.
12 L2 Contamination
130 173 Indicator
Pilot Pressure
Compensator
L1 L1 L7 L1 D6 D5
L6
H8 MA
B
H7
H6 D12 0
+Vmax
H4 D3
Center bore
DIN332
L5 M18x1.5-12deep
B8 L8 L2 D7 only Size 090
B5 L4
B4 L3
Splined shaft
Dim. See page 51
MA View X
L19
A T
X T
L1
L3
D1 D2
D5
B7 B12
L1
SIZE H1 H2 H3 H4 H5 H6 H7 H8
+0.2
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L18 L19 L20 L21
066 342 274 150 35 8 58 16 26 120 185 35.7 69.8 27.8 57.2 328 576 245.6 245.6 68 58
090 342 274 150 35 8 58 16 26 120 185 42.88 77.77 27.8 57.2 328 576 245.6 245.6 68 58
130 483 391 185 40 9 82 20 32 148 229 50.8 89 27.8 57.2 451 738 316 306 78 68
180 483 391 185 40 9 82 20 32 148 229 50.8 89 31.8 66.7 451 738 316 306 78 68
250 622 505 230 50 10 105 25 41 187 281 69.8 120.7 31.8 66.7 579 931 403 403 90 80
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 49
Pump
Dimensions - L3
PVXS Thru-Drive L2
22
Mounting, Thru-Drive Options
SAE “A” and SAE “B”
10
106.4 L1
130 O-ring supplied
M10-20deep loose with PV pump
For SAE"A", splined shaft,
16/32 DP-9 teeth
L3
L2
22
H
1 Ø82.58+0.03
For SAE"A",
splined shaft,
10 16/32 DP-9 teeth
106.4 L1
130 O-ring supplied
M10-18deep loose with PV pump
33
For SAE"B",
splined shaft,
16/32 DP-13 teeth
89.8 9
146 12
B1 O-ring supplied
loose with PV pump
50 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
Splined Shafts
For Variable Displacement
Pumps (PVXS) Only
68
Size 066 / 090
W40x1.25x10a
DIN 5480
Center bore
DM12 DIN332 58
W50x1.25x10a
DIN 5480
Center bore 68
DM16 DIN332
Size 250 90
W62x1.25x10a
DIN5480
Center bore
DM20 DIN332 80
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 51
Pump
Dimensions -
PVXS SAE 4-Bolt
Mounting Pads
0,2 bar
(3 psi)
check
Shaft
down
L3
L1
0,2 bar
(3 psi)
check
52 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Application Data -
Fluid
Recommendations
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 53
Notes
54 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Notes
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 55
Eaton Eaton Eaton
14615 Lone Oak Road 20 Rosamond Road Dr.-Reckeweg-Str. 1
Eden Prairie, MN 55344 Footscray D-76532 Baden-Baden
USA Victoria 3011 Germany
Tel: 952 937-9800 Australia Tel: (49) 07221 682-0
Fax: 952 974-7722 Tel: (61) 3 9319 8222 Fax: (49) 07221 682-788
www.hydraulics.eaton.com Fax: (61) 3 9318 5714
Vickers
Printed in USA
Document No. V-PUPI-TM004-E
March 2003