Graco G1 Autolube
Graco G1 Autolube
Graco G1 Autolube
G1™ Plus
Lubrication Pump 332317P
EN
For dispensing of NLGI Grades #000 to #2 greases and oil with at least 40cSt. For
Professional Use Only.
3132066
conforms to ANSI/UL 73
certified to CAN/CSA
Std. 22.2 No 68-09
110-240VAC Pumps ONLY.
Table of Contents
Table of Contents
Grease Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Oil Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Component Identification . . . . . . . . . . . . . . . . . . 7
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . 8
Choosing an Installation Location . . . . . . . . . . . . 8
System Configuration and Wiring . . . . . . . . . . . . 9
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Pressure Relief . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connecting to Auxiliary Fittings . . . . . . . . . . . . 16
Loading Grease . . . . . . . . . . . . . . . . . . . . . . . . . 17
Filling Oil Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Plus Model Control Setup . . . . . . . . . . . . . . . . . . . 19
Control Panel Overview (FIG. 13) . . . . . . . . . . . 19
Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Advanced Programming . . . . . . . . . . . . . . . . . . . . 23
Models with Firmware 4.01 and Later . . . . . . . 24
Run Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Time Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Additional Fault/Warning Scenarios for Firmware
Versions 0402 . . . . . . . . . . . . . . . . . . . . . . . 27
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Parts: 2 Liter Models . . . . . . . . . . . . . . . . . . . . . . . 29
Parts: 4 and 8 Liter Models . . . . . . . . . . . . . . . . . . 30
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Technical Specifications . . . . . . . . . . . . . . . . . . . . 33
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
California Proposition 65 . . . . . . . . . . . . . . . . . . 33
Mounting Pattern
For correct mounting configuration, choose
either Option 1 or Option 2. See Part Number
126916 template. . . . . . . . . . . . . . . . . . . . . 34
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 36
2 332317P
Grease Models
Grease Models
Reservoir Size
Low
Model CPC DIN Wiper Follower
Level
2 Liter 4 Liter 8 Liter
94G000 X X X
94G001 X X X
94G002 X X X
94G003 X X X X
94G004 X X X X
94G005 X X X X
94G012 X X X
94G013 X X X
94G014 X X X
94G015 X X X X
94G016 X X X X
94G017 X X X X
94G024 X X X
94G025 X X X
94G026 X X X
94G027 X X X X
94G028 X X X X
94G029 X X X X
94G048 X X X X
94G049 X X X X
94G050 X X X X
94G051 X X X X X
94G052 X X X X X
94G053 X X X X X
94G054 X X X X X
94G055 X X X X X
94G056 X X X X X
94G080 X X X
332317P 3
Oil Models
Oil Models
Reservoir Size
Low
Model CPC DIN
Level
2 Liter 4 Liter 8 Liter
94G030 X X
94G031 X X
94G032 X X
94G033 X X X
94G034 X X X
94G035 X X X
94G057 X X X
94G058 X X X
94G059 X X X
94G060 X X X X
94G061 X X X X
94G062 X X X X
4 332317P
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-spe-
cific hazard symbols and warnings not covered in this section may appear throughout the body of this manual
where applicable.
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing or
installing equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.
332317P 5
Warnings
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
• Do not point dispensing device at anyone or at any part of the body.
• Do not put your hand over the fluid outlet.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing
equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.
6 332317P
Installation
Installation
Component Identification
K
Oil Models
C
D
F
B
G L
FIG. 1:
Key:
A Reservoir
B Pump Element
C Pressure Relief Valve (Not included / required)
D Zerk Inlet Fill Fitting (1 included / grease models only)
E Power, DIN (if equipped)
F Power, CPC (if equipped)
G Model Number/ Serial Number
H Follower Plate (grease models only / not available on all
grease models)
J Vent Hole
K Fill cap (oil models only)
L Control Panel
332317P 7
Installation
Typical Installation
C
D
This device has an automatic timer that activates the pump lubrication system when power is connected or when
exiting the programming function. Before you install or remove the lubrication pump from the system, disconnect
and isolate all power supplies and relieve all pressure.
• Select a location that will adequately support the • Use designated mounting holes and provided con-
weight of the G1 Pump and lubricant, as well as all figurations only.
plumbing and electrical connections.
• Always mount the G1 oil models upright.
• Refer to the two mounting hole layouts provided in
• If the G1 grease model is going to be operated in a
the Mounting Pattern section of this manual, page
tilted or inverted position for any period of time, you
33.
must use a model that includes a follower plate, oth-
erwise the G1 must be mounted upright.
NOTE: The two mounting hole layouts provided in
the Technical Specifications section show the only • Use the three fasteners (included) to secure the G1
correct installation patterns to use for mounting the to the mounting surface.
G1. No other installation configurations should be
used. • In high vibration environments and when using an
AC model, additional dampening at mounting point
is necessary.
8 332317P
Installation
332317P 9
Installation
Power DIN AC 11
16U790
DIN 15 ft.
Power DIN DC 12
127783
Power CPC DC 13
CPC 15 ft., 3-wire
127780
14
CPC 15 ft., 5-wire
127781
Power CPC DC 14
CPC 20 ft., 5-wire
127782
14
CPC 30 ft., 5-wire
10 332317P
Installation
Cable Specifications
• United States/Canada: 3 conductor 16 AWG UL62 and CSA 22.2 No. 49 listed SOOW cable with black, white,
green insulation
• Europe: 3 Class-5 conductor, 1.5 mm2 Agency Listed H07RN-F cable with blue, brown, green/yellow insulation
• Japan/Taiwan: 3 conductor, 1.25 mm2 Agency Listed 2 PNCT cable with black, white, red insulation
• SEA/India/Australia: 3 conductor, 1.5 mm2 Agency Listed H07RN-F blue, brown, green/yellow insulation
• China: 3 conductor, 1.5 mm2 Agency Listed YZW cable with blue, brown, green/yellow insulation
Wire Color
United States/ Japan/ SEA/India/
PIN Pin Name Canada Europe Taiwan Australia China
1 Line Black Brown Black Brown Brown
2 Neutral White Blue White Blue Blue
3 Not used Not used Not used Not used Not used Not used
FIG. 2
332317P 11
Installation
Cable Specifications
• United States/Canada: 3 conductor 16 AWG UL62 and CSA 22.2 No. 49 listed SOOW cable with black, white,
green insulation
• Europe: 3 Class-5 conductor, 1.5 mm2 Agency Listed H07RN-F cable with blue, brown, green/yellow insulation
• Japan/Taiwan: 3 conductor, 1/25 mm2 Agency Listed 2 PNCT cable with black, white, red insulation
• SEA/India/Australia: 3 conductor, 1.5 mm2 Agency Listed H07RN-F blue, brown, green/yellow insulation
• China: 3 conductor, 1.5 mm2 Agency Listed YZW cable with blue, brown, green/yellow insulation
Wire Color
United States/ Japan/ SEA/India/
PIN Pin Name Canada Europe Taiwan Australia China
1 -VDC Black Brown Black Brown Brown
2 +VDC White Blue White Blue Blue
3 Not used Not used Not used Not used Not used Not used
FIG. 3
12 332317P
Installation
Installation Notes
• Crimp pins to wire and install in socket connector
per manufacturer’s instructions.
• See Pin Layout shown in FIG. 4 for proper location
in the connector.
• Secure socket connector to the cable per the
desired strain relief configuration.
Cable Specifications
• United States/Canada: 3 conductor 16 AWG UL62
and CSA 22.2 No. 49 listed SOOW cable with
black, white, green insulation
Color
Pin Pin Name United States / SEA / India /
Europe Japan / Taiwan China
Canada Australia
1 Not Used Not Used Not Used Not Used Not Used Not Used
2 ‐VDC Black Brown Black Brown Brown
3 +VDC White Blue White Blue Blue
4 Not Used Not Used Not Used Not Used Not Used Not Used
5 Not Used Not Used Not Used Not Used Not Used Not Used
6 Not Used Not Used Not Used Not Used Not Used Not Used
7 Not Used Green Green/Yellow Red Green/Yellow Green/Yellow
332317P 13
Installation
Installation Notes
Part No.: 127780: 15 ft (4.5 m) • Crimp pins to wire and install in socket connector
Part No.: 127781: 20 ft (6.1 m) per manufacturer’s instructions.
Part No.: 127782: 30 ft (9.1 m) • See Pin Layout shown in FIG. 5 for proper location
in the connector.
NOTE: An Illuminated Remote Run Button Kit: 571030, • Secure socket connector to the cable per the
571031 for starting a manual run cycle remotely if used desired strain relief configuration.
in conjunction with a 5-wire CPC cable, is available
from Graco. Contact your local Graco distributor or Cable Specifications
Graco Customer Service for additional information
about these kits. • United States/Canada: 5 conductor 16 AWG UL62
and CSA 22.2 No. 49 listed SOOW cable with
CPC Connector Specifications black, white, red, orange, green/yellow insulation
• One, 7-position, 1.5 mm socket connector AMP • Europe: 5 Class-5 conductor, 1.5 mm2 Agency
967650-1 Listed H07RN-F cable with blue, brown, black,
• Five, 16 - 14 gauge female pins AMP 962999-1 grey, green/yellow insulation
• One, 180-degree strain relief or one, 90-degree
strain relief AMP 965576-1 (determined by cable • Japan/Taiwan: 5 conductor, 1/25 mm2 Agency
exit for cable configuration) Listed 2 PNCT cable with black, white, red insula-
tion, green, black
Color
Pin Pin Name United States / SEA / India /
Europe Japan / Taiwan China
Canada Australia
1 Not Used Not Used Not Used Not Used Not Used Not Used
2 ‐VDC Black Brown Black Brown Brown
3 +VDC Red Blue White Blue Blue
4 LIGHT White Black Green Black Black
5 MANUAL Orange Grey Not Used Grey Grey
6 Not Used Not Used Not Used Not Used Not Used Not Used
7 Not Used Green Green/Yellow Black Green/Yellow Green/Yellow
14 332317P
Installation
FIG. 5
332317P 15
Setup
Pressure Relief
Follow the Pressure Relief Procedure when-
ever you see this symbol.
NOTICE
Do not attach unsupported equipment to auxiliary
fittings such as fill ports and pump element. Attach-
ing unsupported equipment to these fitting can
result in irreparable housing damage.
• Always use two wrenches working in opposite
This equipment stays pressurized until pressure is directions when connecting anything to pump
manually relieved. To help prevent serious injury element or auxiliary fittings. See FIG. 6 for an
from pressurized fluid, such as skin injection, example.
splashing fluid and moving parts, follow the • Torque pump element fittings to 50 in. lbs (5.6
Pressure Relief Procedure when you stop spraying N•m).
and before cleaning, checking, or servicing the
equipment. • When connecting pump element into housing
torque to 50 in. lbs (5.6 N•m).
FIG. 6
16 332317P
Setup
Loading Grease 3. Fill reservoir with NLGI grease to max fill line.
To ensure optimal performance from the G1: NOTE: Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
• Only use NLGI #000 - #2 greases appropriate for
your application, automatic dispensing, and the
equipment’s operating temperature. Consult with
machine and lube manufacturer for details.
• The reservoir can be filled using a hand operated
pump, pneumatic pump or electric transfer pump.
• Do not overfill (FIG. 8).
• Do not operate G1 without reservoir attached.
NOTICE
• Always clean fitting (37) with a clean dry cloth Max Fill
prior to filling reservoir. Dirt and/or debris can
damage pump and/or lubrication system. FIG. 8
• Care must be used when filling the reservoir 4. Remove fill hose.
using a pneumatic or electric transfer pump to
not pressurize and break the reservoir. Models with a follower plate:
Models without a follower plate: 1. Connect fill hose to inlet fitting (FIG. 7).
37 Vent Hole
FIG. 7
332317P 17
Setup
Filling Oil Unit Pump only requires priming the first time it is used or if
it is allowed to run dry.
• Only use oil appropriate for your application, auto-
matic dispensing, and the equipment’s operating 1. Loosen pump element fitting (FIG. 11).
temperature. Consult with machine and lube manu-
NOTE: When loosening pump element fitting, do NOT
facturer for details.
loosen pump element. Loosening pump element will
• The reservoir can be filled using a hand operated change the output volume
pump, pneumatic pump or electric transfer pump.
• Do not overfill (FIG. 10).
• Do not operate G1 without reservoir attached.
• Only use oils with viscosity at least 40 cSt.
FIG. 11
FIG. 12
18 332317P
Plus Model Control Setup
LOCK ICON
Lubrication Pump
FIG. 13
332317P 19
Plus Model Control Setup
ON OFF
Lubrication Pump
MM HH
20 332317P
Plus Model Control Setup
2. The LED next to the LOCK ICON on 2. Press the ENTER button. The next MM
the display lights and the 4 zeros number field to the right flashes indicat-
appear on the display indicating the ing it is ready for programming.
system requires a PIN Code entry to access the G1
in SETUP MODE. 3. Use the UP or DOWN
ARROW button to scroll
3. The cursor is automatically through numerals 0 to 9 until
positioned to enter the first the desired number appears
character of the PIN Code. in the second MM number
Use the UP and DOWN field.
ARROW buttons to move up
and down through the numbers 0-9 until the first 4. After pressing the ENTER button to set
number in the PIN code is displayed in the field. the last MM field, all the programmed
ON Time information is saved.
4. Press the ENTER button to set the
number. The cursor automatically The G1 automatically switches to the OFF Time
moves to the next number field. SETUP MODE.
332317P 21
Plus Model Control Setup
22 332317P
Advanced Programming
Advanced Programming
Advanced
Setting Format/ Description Why Use This?
Option
Lockout
Secures setup modes with
A1 Code Prevents unauthorized users to adjusting settings.
PIN
(Optional)
A10 Low Level Reset Changes low level fault upon This function changes the behavior of the low
Upon Power ON power ON. level fault upon power ON.
Default = OFF
Entering a PIN Code for the First Time 6. Repeat steps 4 and 5 for each PIN Code prompt
field.
Setting Up PIN Code
7. Press the ENTER button to save the
A PIN Code can be programmed into the G1 to protect PIN Code and exit Advanced Setup.
the settings from inadvertently being changed by unau-
thorized users.
Entering Advanced Setup
1. Press the UP ARROW button for 10
seconds. Press the UP ARROW button for 10 sec-
onds.
The LED next to the LOCK ICON on the If the G1 was previously set up to require a
display lights, indicating you have entered PIN Code, the LED next to the LOCK ICON
the PIN Mode. lights, indicating a PIN Code is required.
332317P 23
Advanced Programming
Models with Firmware 4.01 and 2. Press the UP or DOWN ARROW button to change
OFF to ON on the display to change the low level
Later reset upon power on.
ON OFF
MM HH
Lubrication Pump
FIG. 15
24 332317P
Run Mode
After setup is complete, the G1 automatically begins to • The LED next to the LOW LEVEL
run the OFF Time sequence. ICON on the display flashes.
• The G1 runs the Add lubricant to the pump. See Loading Grease
programmed OFF ON OFF instructions, page 17 or Filling Oil Unit, page 18.
sequence.
• After lubricant is added, press the
(Notice the dot RESET button to clear the fault.
below OFF flashes
on the display MM HH
while the OFF Time NOTE: For higher viscosity fluids it may be
counts down. This necessary to clear the low level fault prior to
count down is in hours.) filling the pump. You can then press the
Manual Start button to start the pump
• When the OFF during the fill.
Time count ON OFF
reaches zero, the
Manual Run Cycle
G1 Automatic
Lubrication Pump To run an extra (non-programmed) lubrica-
turns the pump on tion cycle, push the Manual Start button.
and it runs for the MM HH
programmed ON NOTE: An Illuminated Remote Run Button
Time cycle. Kit: 571030, 571031 for starting a manual run cycle
remotely if used in conjunction with a 5-wire CPC
(Notice the dot below ON flashes on the display.) cable, is available from Graco. Contact your local Graco
distributor or Graco Customer Service for additional
• When the ON Time count reaches zero, the pump information about these kits.
shuts off again and the system again runs OFF
Time cycle and the OFF Time LED flashes again.
332317P 25
Troubleshooting
Troubleshooting
Unit does not power on (DC models Replace lubricant with pumpable lubri-
only) Tripped external fuse due to pumping cant, rated for environmental conditions
non-cold weather lubricant in cold and application.
weather -13°F (-25°C)
Replace fuse.
Tripped internal power supply fuse due
Unit does not power on (AC models only) Contact Graco Customer Service.
to power supply failure
Allowable ON time: 1-30 minutes Adhere to allowable duty cycle. Contact
Can’t set desired ON/OFF times Allowable OFF time: 1-24 hours Graco Customer Support if other duty
(in full minute or hour increments) cycles are required for application.
Verify the unit was programmed as
Unit is not operating based on the time Time entered was misinterpreted as MM
intended, referencing programming
that was programmed instead of HH (or visa versa)
instructions.
Reservoir retaining tabs are cracked or
Replace reservoir.
broken
Lubricant leaks past seal located on the Ensure vent hole is not plugged.
bottom of the reservoir Reservoir is being pressurized during fill-
If problem persists, contact Graco Cus-
ing tomer Service or your local Graco dis-
tributor for assistance.
Unit not pumping during ON cycle, but
Failed motor Replace unit.
controller lights and functions
Add grease following Loading Grease
Air is trapped in the reservoir between
Follower plate is not going down instructions, page 17. Ensure air is
the follower plate and lubricant
purged.
Increase pump on time.
Pump takes several minutes before it Pumping non-cold weather lubricant in
begins pumping cold weather -13°F (-25°C) Use grease suitable for temperature and
conditions.
Tripped internal, resettable fuse due to Verify manual run inputs have not cre-
Dim display, unit is not operating internal component failure or short cir- ated a short circuit condition. Cycle
cuit condition power.
Unit indicates a cycle or pressure alarm
Refer to programming ON Time, page
before the lubrication cycle could com- The ON Time was not entered correctly
21.
plete
26 332317P
Troubleshooting
Lubrication Pump
332317P 27
Maintenance
Maintenance
Frequency Component Required Maintenance
Keep all fittings clean using a clean
dry cloth. Dirt and/or debris can
Daily and at refill Zerk Fittings
damage pump and/or lubrication
system.
Keep pump unit and reservoir clean
Daily G1 Pump Unit and Reservoir
using a clean dry cloth.
Keep display clean using a clean dry
Daily Display
cloth.
Monthly External Wiring Harness Verify external harnesses are secure.
28 332317P
Parts: 2 Liter Models
43
40b
44 42
35
41
Follower Plate Models Only
23
57 271
40a
60
15 16
13
14
67 12
3 37
1
31
66
17 3
Low Level Oil Models Only
33
332317P 29
Parts: 4 and 8 Liter Models
43
41
40b
44
42
Follower Plate Models Only 35
23
57 271
40a
61 60
16
56
62
67
13
14
12
66 3 37
1
30 332317P
Parts
Parts
FN Part No. Description Qty. FN Part No. Description Qty.
1 BASE, molded 1 SEAL, follower plate, 2 liter grease
278139 1
3 278142 BOTTOM, cover 1 models
4 115477 SCREW, bottom cover 9 SEAL, follower plate, 4 liter grease
41 16F472 2
RECT-RING, included in Kit 571069, models
12 127079 1 SEAL, follower plate, 8 liter grease
571179, 571042 16V763 2
O-RING, included in Kit 571042, models
13 132524 1
571044, 571045, 571069, 571179 42 PLATE, follower, grease models 1
14 PLATE, ricer 1
43 ROD, follower plate, grease models 1
15 BEARING, ball 1
SPRING, compression, grease mod-
PADDLE, stirring, 2 liter models with- 44 1
els
out follower plate, included in Kit 1
571044 24D838 BAFFLE, low level, 2 liter models 1
PADDLE, stirring, 4 and 8 liter mod-
45† 24E246 BAFFLE, low level, 4 liter models 1
els without follower plate, included in 1
16
Kit 571046
24F836 BAFFLE, low level, 8 liter models 1
PADDLE, stirring, 2 liter models with
1
follower plate, included in Kit 571045 56 127144 SEAL, oval 1
PADDLE, stirring, 4 liter models with
1
follower plate, included in Kit 571047 57 117156 BEARING, sleeve 1
17 ELEMENT, pump 1
58 196548 LABEL, shock warning 1
23‡ 278942 PADDLE, low level models 1
60 16D984 WASHER, low level models 2
27 123025 SCREW, M6 1 RESERVOIR, mid-section, 8 liter
61 1
models
24Z798 or
30‡✺ BOARD, circuit 1 ADAPTER, reservoir 4 and 8 liter
25U993 62 1
models
31 119228 SCREW, machine, flat head 2
66 126417 NUT 1
33 16A579 LABEL, safety 1
67 24N806 FLOAT, oil models 1
34 16T912 LABEL, overlay 1
Replacement Danger and Warning labels, tags and cards are
WIPER, stirring, models without fol-
available at no cost.
lower plate, included in Kit 571044, 1
571046 ‡✺Also order Ref 31 and Ref 34.
35
WIPER, stirring, models with follower
plate, included in Kit 571045, 1 † Also order Ref. 57 when ordering this part.
571047
FITTING, zerk, grease models (not
37 123741 1
included on oil models)
RESERVOIR, 2 liter, grease, included
40a 1
in Kit 571042, 571069
RESERVOIR, 2 liter, oil, included in
40b 1
Kit 571179
RESERVOIR, 4 liter, grease, included
40a 1
in Kit 571183
RESERVOIR, 4 liter, oil, included in
40b 1
Kit 571182
40a RESERVOIR, 8 liter grease 1
RESERVOIR, 8 liter, oil, included in
40b 1
Kit 571182
332317P 31
Parts
32 332317P
Technical Specifications
Technical Specifications
G1™ Plus Lubrication Pump
US Metric
Maximum Working Pressure 5100 psi 35.1 MPa, 351.6 bar
Power
100 - 240 VAC 88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz, Single phase,
inrush/locked rotor, max 40 A (1ms)
12 VDC 9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A
24 VDC 18 - 30 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A
Pumps 1
Dimensions
Height Width Depth
Model
Inches cm Inches cm Inches cm
2L 13.25 33.65 8.00 20.32 9.00 22.86
4L 14.50 36.83 9.25 23.50 10.00 25.40
8L 18.50 47.00 9.25 23.50 10.00 25.40
California Proposition 65
WARNING: This product can expose you to chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information, go to
www.P65warnings.ca.gov.
332317P 33
Technical Specifications
Mounting Pattern
For correct mounting configuration, choose either Option 1 or Option 2. See Part Number 126916 template.
Option 1
0.367inch 7.087 inch
9.3 mm 180.0 mm
2x Ø 0.366 inch
9.3 mm 1.180 inch
30.0 mm
3.268 inch
83.0 mm
3.544 inch
90.0 mm
Option 2
0.722 inch 6.378 inch
18.3 mm 162.0 mm
2x Ø 0.366 inch
0.708 inch
9.3 mm
18.0 mm
3.740 inch
95.0 mm
3.189 inch
81.0 mm
FIG. 16
34 332317P
Notes
Notes
332317P 35
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification
of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be
returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or
workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental
or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder,
or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered
into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu
que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés,
à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.