G1™ Plus
Lubrication Pump 332317P
EN

For dispensing of NLGI Grades #000 to #2 greases and oil with at least 40cSt. For
Professional Use Only.

Not approved for use in explosive atmospheres or hazardous locations.

Part Nos., page 3


5100 psi (35.1 MPa, 351.6 bar) Maximum Working Pressure

Important Safety Instructions


Read all warnings and instructions in this
manual. Save these instructions.

3132066
conforms to ANSI/UL 73
certified to CAN/CSA
Std. 22.2 No 68-09
110-240VAC Pumps ONLY.
Table of Contents

Table of Contents
Grease Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Oil Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Component Identification . . . . . . . . . . . . . . . . . . 7
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . 8
Choosing an Installation Location . . . . . . . . . . . . 8
System Configuration and Wiring . . . . . . . . . . . . 9
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Pressure Relief . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connecting to Auxiliary Fittings . . . . . . . . . . . . 16
Loading Grease . . . . . . . . . . . . . . . . . . . . . . . . . 17
Filling Oil Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Plus Model Control Setup . . . . . . . . . . . . . . . . . . . 19
Control Panel Overview (FIG. 13) . . . . . . . . . . . 19
Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Advanced Programming . . . . . . . . . . . . . . . . . . . . 23
Models with Firmware 4.01 and Later . . . . . . . 24
Run Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Time Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Additional Fault/Warning Scenarios for Firmware
Versions 0402 . . . . . . . . . . . . . . . . . . . . . . . 27
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Parts: 2 Liter Models . . . . . . . . . . . . . . . . . . . . . . . 29
Parts: 4 and 8 Liter Models . . . . . . . . . . . . . . . . . . 30
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Technical Specifications . . . . . . . . . . . . . . . . . . . . 33
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
California Proposition 65 . . . . . . . . . . . . . . . . . . 33
Mounting Pattern
For correct mounting configuration, choose
either Option 1 or Option 2. See Part Number
126916 template. . . . . . . . . . . . . . . . . . . . . 34
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 36

2 332317P
Grease Models

Grease Models
Reservoir Size
Low
Model CPC DIN Wiper Follower
Level
2 Liter 4 Liter 8 Liter

94G000 X X X
94G001 X X X
94G002 X X X
94G003 X X X X
94G004 X X X X
94G005 X X X X
94G012 X X X
94G013 X X X
94G014 X X X
94G015 X X X X
94G016 X X X X
94G017 X X X X
94G024 X X X
94G025 X X X
94G026 X X X
94G027 X X X X
94G028 X X X X
94G029 X X X X
94G048 X X X X
94G049 X X X X
94G050 X X X X
94G051 X X X X X
94G052 X X X X X
94G053 X X X X X
94G054 X X X X X
94G055 X X X X X
94G056 X X X X X
94G080 X X X

332317P 3
Oil Models

Oil Models
Reservoir Size
Low
Model CPC DIN
Level
2 Liter 4 Liter 8 Liter

94G030 X X
94G031 X X
94G032 X X
94G033 X X X
94G034 X X X
94G035 X X X
94G057 X X X
94G058 X X X
94G059 X X X
94G060 X X X X
94G061 X X X X
94G062 X X X X

4 332317P
Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-spe-
cific hazard symbols and warnings not covered in this section may appear throughout the body of this manual
where applicable.

WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing or
installing equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

EQUIPMENT MISUSE HAZARD


Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
See Technical Specifications in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Specifications in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your
material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s
replacement parts only.
• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety
hazards.
• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

332317P 5
Warnings

WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
• Do not point dispensing device at anyone or at any part of the body.
• Do not put your hand over the fluid outlet.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing
equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.

PRESSURIZED EQUIPMENT HAZARD


Over-pressurization can result in equipment rupture and serious injury.
• A pressure relief valve is required at each pump outlet.
Follow Pressure Relief Procedure in this manual before servicing.

PLASTIC PARTS CLEANING SOLVENT HAZARD


Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or
property damage.
• Use only compatible water-based solvents to clean plastic structural or pressure-containing parts.
• See Technical Specifications in this and all other equipment instruction manuals. Read fluid and
solvent manufacturer’s MSDSs and recommendations.

MOVING PARTS HAZARD


Moving parts can pinch or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the
Pressure Relief Procedure in this manual. Disconnect power or air supply.

PERSONAL PROTECTIVE EQUIPMENT


You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the
equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and
burns. This equipment includes but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

6 332317P
Installation

Installation

Component Identification
K

Oil Models

Grease Models Grease Models with Follower


Plate
A

C
D
F

B
G L

FIG. 1:
Key:
A Reservoir
B Pump Element
C Pressure Relief Valve (Not included / required)
D Zerk Inlet Fill Fitting (1 included / grease models only)
E Power, DIN (if equipped)
F Power, CPC (if equipped)
G Model Number/ Serial Number
H Follower Plate (grease models only / not available on all
grease models)
J Vent Hole
K Fill cap (oil models only)
L Control Panel

332317P 7
Installation

Typical Installation

C
D

A Connected to fuse / power C Series progressive divider valves


B Pressure relief valve (required, user supplied) D To lube points

Choosing an Installation Location

AUTOMATIC SYSTEM ACTIVATION HAZARD


Unexpected activation of the system could result in serious injury, including skin injection and amputation.

This device has an automatic timer that activates the pump lubrication system when power is connected or when
exiting the programming function. Before you install or remove the lubrication pump from the system, disconnect
and isolate all power supplies and relieve all pressure.

• Select a location that will adequately support the • Use designated mounting holes and provided con-
weight of the G1 Pump and lubricant, as well as all figurations only.
plumbing and electrical connections.
• Always mount the G1 oil models upright.
• Refer to the two mounting hole layouts provided in
• If the G1 grease model is going to be operated in a
the Mounting Pattern section of this manual, page
tilted or inverted position for any period of time, you
33.
must use a model that includes a follower plate, oth-
erwise the G1 must be mounted upright.
NOTE: The two mounting hole layouts provided in
the Technical Specifications section show the only • Use the three fasteners (included) to secure the G1
correct installation patterns to use for mounting the to the mounting surface.
G1. No other installation configurations should be
used. • In high vibration environments and when using an
AC model, additional dampening at mounting point
is necessary.

8 332317P
Installation

System Configuration and Fuses


Wiring NOTICE
Fuses (user supplied) are required on all DC models.
Grounding
To avoid equipment damage:
• Never operate G1 Pump DC models without a fuse
installed.
• A fuse of the correct voltage must be installed in
Improper installation of the grounding conductor may
.

line with the power entry to the system.


result in a risk of electric shock. This product must be
installed by a qualified electrician in compliance with
all state and local codes and regulations. Fuse Kits are available from Graco. The following Table
identifies the correct fuse to use for your input voltage
If the product is permanently connected: and the corresponding Graco Kit number.
• it must be installed by a qualified electrician or ser-
viceman. Input Voltage Fuse Value Graco Kit No.
• it must be connected to a grounded, permanent 12 VDC 7.5 A 571039
wiring system.
24 VDC 4A 571040
If an attachment plug is required in the end use
application:
Recommendations for Using Pump in
• it must be rated for the product electrical specifica-
tions. Harsh Environments
• it must be an approved, 3-wire grounding type • Use pump with CPC style power cable.
attachment plug. • If using a DIN style power harness with a right angle
• it must be plugged into an outlet that is properly mating connector, make sure the connector does
installed and grounded in accordance with all local not exit the unit in the UP direction.
codes and ordinances. • Use a corrosion preventative electrical grease on all
• when repair or replacement of the power cord or contacts.
plug is required, do not connect the grounding wire • In high vibration environments, additional isolation
to either flat blade terminal. at mounting point is necessary.
AC pumps are not recommended when high vibration
or shock is present.

Part No. Description


132187 Isolator mounting kit

332317P 9
Installation

Wiring and Installation Diagrams


NOTE: Graco does not provide a power cable with the G1. Power cables are available for purchase from Graco or
the user may provide their own. See Table 1 for reference pages containing additional information related to Graco
power cables.

Table 1: Graco Power Cables

Cable Part No. Diagram Symbol Page #

Power DIN AC 11

16U790
DIN 15 ft.
Power DIN DC 12

127783
Power CPC DC 13
CPC 15 ft., 3-wire

127780
14
CPC 15 ft., 5-wire
127781
Power CPC DC 14
CPC 20 ft., 5-wire
127782
14
CPC 30 ft., 5-wire

10 332317P
Installation

Power DIN AC - 15 foot: Part No. 16U790

Din Connector Specifications


• DIN 43650 Form A, 18 mm, assembled to power cable manufacturer’s instructions
• Rated to 6 Amps minimum at 250V AC

Cable Specifications
• United States/Canada: 3 conductor 16 AWG UL62 and CSA 22.2 No. 49 listed SOOW cable with black, white,
green insulation

• Europe: 3 Class-5 conductor, 1.5 mm2 Agency Listed H07RN-F cable with blue, brown, green/yellow insulation

• Japan/Taiwan: 3 conductor, 1.25 mm2 Agency Listed 2 PNCT cable with black, white, red insulation

• SEA/India/Australia: 3 conductor, 1.5 mm2 Agency Listed H07RN-F blue, brown, green/yellow insulation

• China: 3 conductor, 1.5 mm2 Agency Listed YZW cable with blue, brown, green/yellow insulation

Pin and Related Wire Color (FIG. 2)

Wire Color
United States/ Japan/ SEA/India/
PIN Pin Name Canada Europe Taiwan Australia China
1 Line Black Brown Black Brown Brown
2 Neutral White Blue White Blue Blue
3 Not used Not used Not used Not used Not used Not used

Ground Green Green/Yellow Red Green/Yellow Green/Yellow

FIG. 2

332317P 11
Installation

Power DIN DC - 15 foot: Part No. 16U790

Din Connector Specifications


• DIN 43650 Form A, 18 mm assembled to power cable manufacturer’s instructions
• Rated to 6 Amps minimum at 250V AC

Cable Specifications
• United States/Canada: 3 conductor 16 AWG UL62 and CSA 22.2 No. 49 listed SOOW cable with black, white,
green insulation

• Europe: 3 Class-5 conductor, 1.5 mm2 Agency Listed H07RN-F cable with blue, brown, green/yellow insulation

• Japan/Taiwan: 3 conductor, 1/25 mm2 Agency Listed 2 PNCT cable with black, white, red insulation

• SEA/India/Australia: 3 conductor, 1.5 mm2 Agency Listed H07RN-F blue, brown, green/yellow insulation

• China: 3 conductor, 1.5 mm2 Agency Listed YZW cable with blue, brown, green/yellow insulation

Pin and Related Wire Color (FIG. 3)

Wire Color
United States/ Japan/ SEA/India/
PIN Pin Name Canada Europe Taiwan Australia China
1 -VDC Black Brown Black Brown Brown
2 +VDC White Blue White Blue Blue
3 Not used Not used Not used Not used Not used Not used

Not used Green Green/Yellow Red Green/Yellow Green/Yellow

FIG. 3

12 332317P
Installation

Power CPC DC - 3-Wire, 15 foot: Part No. 127783

CPC Connector Specifications • SEA/India/Australia: 3 conductor, 1.5 mm2


Agency Listed H07RN-F blue, brown, green/yellow
• One, 7-position, 1.5 mm socket connector AMP
insulation
967650-1
• Three, 16 - 14 gauge female pins AMP 962999-1 • China: 3 conductor, 1.5 mm2 Agency Listed YZW
• One, 180-degree strain relief or one, 90-degree cable with blue, brown, green/yellow insulation
strain relief AMP 965576-1 (determined by cable
exit for cable configuration)

Installation Notes
• Crimp pins to wire and install in socket connector
per manufacturer’s instructions.
• See Pin Layout shown in FIG. 4 for proper location
in the connector.
• Secure socket connector to the cable per the
desired strain relief configuration.

Cable Specifications
• United States/Canada: 3 conductor 16 AWG UL62
and CSA 22.2 No. 49 listed SOOW cable with
black, white, green insulation

• Europe: 3 Class-5 conductor, 1.5 mm2 Agency


Listed H07RN-F cable with blue, brown, green/yel-
low insulation

• Japan/Taiwan: 3 conductor, 1/25 mm2 Agency


Listed 2 PNCT cable with black, white, red insula-
tion FIG. 4

Pin and Related Wire Color (FIG. 4)

Color
Pin Pin Name United States / SEA / India /
Europe Japan / Taiwan China
Canada Australia
1 Not Used Not Used Not Used Not Used Not Used Not Used
2 ‐VDC Black Brown Black Brown Brown
3 +VDC White Blue White Blue Blue
4 Not Used Not Used Not Used Not Used Not Used Not Used
5 Not Used Not Used Not Used Not Used Not Used Not Used
6 Not Used Not Used Not Used Not Used Not Used Not Used
7 Not Used Green Green/Yellow Red Green/Yellow Green/Yellow

332317P 13
Installation

Power CPC DC - 5 wire

Installation Notes
Part No.: 127780: 15 ft (4.5 m) • Crimp pins to wire and install in socket connector
Part No.: 127781: 20 ft (6.1 m) per manufacturer’s instructions.
Part No.: 127782: 30 ft (9.1 m) • See Pin Layout shown in FIG. 5 for proper location
in the connector.
NOTE: An Illuminated Remote Run Button Kit: 571030, • Secure socket connector to the cable per the
571031 for starting a manual run cycle remotely if used desired strain relief configuration.
in conjunction with a 5-wire CPC cable, is available
from Graco. Contact your local Graco distributor or Cable Specifications
Graco Customer Service for additional information
about these kits. • United States/Canada: 5 conductor 16 AWG UL62
and CSA 22.2 No. 49 listed SOOW cable with
CPC Connector Specifications black, white, red, orange, green/yellow insulation

• One, 7-position, 1.5 mm socket connector AMP • Europe: 5 Class-5 conductor, 1.5 mm2 Agency
967650-1 Listed H07RN-F cable with blue, brown, black,
• Five, 16 - 14 gauge female pins AMP 962999-1 grey, green/yellow insulation
• One, 180-degree strain relief or one, 90-degree
strain relief AMP 965576-1 (determined by cable • Japan/Taiwan: 5 conductor, 1/25 mm2 Agency
exit for cable configuration) Listed 2 PNCT cable with black, white, red insula-
tion, green, black

• SEA/India/Australia: 5 conductor, 1.5 mm2


Agency Listed H07RN-F black, white, red insula-
tion, green, black

• China:5 conductor, 1.5 mm2 Agency Listed YZW


cable with black, white, red insulation, green, black

Pin and Related Wire Color (FIG. 5, page 15)

Color
Pin Pin Name United States / SEA / India /
Europe Japan / Taiwan China
Canada Australia
1 Not Used Not Used Not Used Not Used Not Used Not Used
2 ‐VDC Black Brown Black Brown Brown
3 +VDC Red Blue White Blue Blue
4 LIGHT White Black Green Black Black
5 MANUAL Orange Grey Not Used Grey Grey
6 Not Used Not Used Not Used Not Used Not Used Not Used
7 Not Used Green Green/Yellow Black Green/Yellow Green/Yellow

14 332317P
Installation

FIG. 5

Remote Illumination Response

Standard Remote Illumination


(via 5-wire CPC power cable)

Unit in OFF Mode Off


Unit in ON Mode On
Fault Condition Toggles On and Off once per second

332317P 15
Setup

Setup Connecting to Auxiliary Fittings

Pressure Relief
Follow the Pressure Relief Procedure when-
ever you see this symbol.
NOTICE
Do not attach unsupported equipment to auxiliary
fittings such as fill ports and pump element. Attach-
ing unsupported equipment to these fitting can
result in irreparable housing damage.
• Always use two wrenches working in opposite
This equipment stays pressurized until pressure is directions when connecting anything to pump
manually relieved. To help prevent serious injury element or auxiliary fittings. See FIG. 6 for an
from pressurized fluid, such as skin injection, example.
splashing fluid and moving parts, follow the • Torque pump element fittings to 50 in. lbs (5.6
Pressure Relief Procedure when you stop spraying N•m).
and before cleaning, checking, or servicing the
equipment. • When connecting pump element into housing
torque to 50 in. lbs (5.6 N•m).

Relieve pressure in system using two wrenches work-


ing in opposite directions on pump element and pump Pressure Relief Valves
element fitting to slowly loosen fitting only until fitting
is loose and no more lubricant or air is leaking from fit-
ting.
A pressure relief valve appropriate for the lubrication
NOTE: When loosening pump element fitting, do NOT
system must be installed close to the pump outlet to
loosen pump element. Loosening pump element will
alleviate unintended pressure rises in the system and
change the output volume.
protect the G1 pump from damage.

• Only use a pressure relief valve that is rated for no


more than the working pressure of the G1 pump it
is installed on. See Technical Specifications,
page 33.
• Install a pressure relief valve before any auxiliary
fitting.

FIG. 6

16 332317P
Setup

Loading Grease 3. Fill reservoir with NLGI grease to max fill line.
To ensure optimal performance from the G1: NOTE: Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
• Only use NLGI #000 - #2 greases appropriate for
your application, automatic dispensing, and the
equipment’s operating temperature. Consult with
machine and lube manufacturer for details.
• The reservoir can be filled using a hand operated
pump, pneumatic pump or electric transfer pump.
• Do not overfill (FIG. 8).
• Do not operate G1 without reservoir attached.

NOTICE
• Always clean fitting (37) with a clean dry cloth Max Fill
prior to filling reservoir. Dirt and/or debris can
damage pump and/or lubrication system. FIG. 8
• Care must be used when filling the reservoir 4. Remove fill hose.
using a pneumatic or electric transfer pump to
not pressurize and break the reservoir. Models with a follower plate:

Models without a follower plate: 1. Connect fill hose to inlet fitting (FIG. 7).

2. For higher viscosity fluids, press the


1. Connect fill hose to inlet fitting (37) (FIG. 7).
manual run button to start the pump
during fill to rotate the stirring paddle
and prevent air pockets from forming in
grease.

3. Fill reservoir with grease until seal of follower plate


breaches the vent hole (FIG. 9) and the majority of
air is expelled from the reservoir.

37 Vent Hole

FIG. 7

2. For higher viscosity fluids, press the


manual run button to start the pump
during fill to rotate the stirring paddle
and prevent air pockets from forming in
grease. FIG. 9
NOTE: Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
4. Remove fill hose.

332317P 17
Setup

Changing Greases Priming


When changing greases, always use compatible fluids NOTE: It is not necessary to prime pump every time
or greases. pump is filled with lubricant.

Filling Oil Unit Pump only requires priming the first time it is used or if
it is allowed to run dry.
• Only use oil appropriate for your application, auto-
matic dispensing, and the equipment’s operating 1. Loosen pump element fitting (FIG. 11).
temperature. Consult with machine and lube manu-
NOTE: When loosening pump element fitting, do NOT
facturer for details.
loosen pump element. Loosening pump element will
• The reservoir can be filled using a hand operated change the output volume
pump, pneumatic pump or electric transfer pump.
• Do not overfill (FIG. 10).
• Do not operate G1 without reservoir attached.
• Only use oils with viscosity at least 40 cSt.

FIG. 11

FIG. 10 2. Only run pump until air is no longer dispensed with


the lubricant coming out of element fitting (FIG. 12).
1. Remove fill cap (a).

2. Pour oil into reservoir to fill line (b).

3. Replace fill cap. Hand tighten cap, securely.

FIG. 12

3. Tighten pump element fitting using two wrenches


working in opposite directions (FIG. 11).

18 332317P
Plus Model Control Setup

Plus Model Control Setup


Control Panel Overview (FIG. 13)
NOTE: Programming instructions begin on page 20.
OFF TIME

ON TIME • The blinking LED below OFF indicates the


OFF Time sequence is running.
• Value is entered in HH.
• The blinking LED below ON
• Displays in HH.
indicates the ON Time LOW LEVEL FAULT
sequence is running. • Times pump rest between cycles.
• Display shows time as MM • Counts down from a set time to zero. LED next to icon lights when
(minutes). pump is out of lubricant. Pump
i.e., 02 is 2 minutes. run cycle stops.
• Times lubrication cycle.
• Counts down from a set time to ON OFF

LOCK ICON

• LED next to icon lights


MM HH indicating PIN is required
to enter setup.
• In SETUP MODE LED
lights when setting up the
PIN.

Lubrication Pump

RIGHT DIRECTION ARROW


/ MANUAL RUN / ENTER:
LEFT DIRECTION ARROW /
RESET • In SETUP MODE, saves entry,
UP and DOWN ARROW moves cursor in display one
field to the right or to the next
• In SETUP MODE, moves cursor setup step.
• Hold both the UP and DOWN ARROW but-
in display one field to the left.
tons down together for 3 seconds to enter • In RUN MODE starts a man-
• In Low Level Fault Mode: ual run cycle.
SETUP MODE.
pressing and holding for 3 sec-
onds clears fault and switches • In SETUP MODE, increases or decreases
cycle to OFF MODE. number values shown in display.

FIG. 13

332317P 19
Plus Model Control Setup

Instructions The G1 Plus model uses a timer to regulate how long a


pump cycle runs and the length of time the pump rests
between cycles.
Checking the Firmware Version
To check the firmware version installed on the pump: NOTE:
• A blinking number on the display indicates the G1 is
1. Remove power to the pump by disconnecting the in SETUP MODE.
power cable from the connection.
• In RUN MODE numbers on the display do not blink.
2. Reconnect the power cable to the power connec- • After 60 seconds of no activity, the device returns
tion. to RUN MODE in the OFF Time cycle and the OFF
Time restarts counting down the total programmed
This creates a power cycle and the firmware ver- amount of time. It does not resume the countdown
sion displays on the screen during the first few sec- from the point where the cycle was interrupted
onds of power up. See FIG. 14. when you entered SETUP MODE.

Entering Setup Mode


ON OFF Press both the UP and DOWN
ARROW buttons together for 3
seconds to enter the SETUP
MODE.

MM HH NOTE: If the lock LED is lit after entering Setup Mode


and four 0000’s are displayed, the unit has a PIN Code
lock out enabled. See Entering a PIN Code to Access
Setup Mode for instructions on entering a value.

ON OFF

Lubrication Pump

MM HH

FIG. 14 Entering a PIN Code to Access Setup Mode


The G1 controller does not require a user to provide a
Powering Units With Controllers
PIN code to access the programming features of the
By default, units with controllers are set to unit. However, Graco understands that some users may
operate in a timed mode: want to protect the program settings and therefore, an
option for adding PIN Code authorization is available.
FIRMWARE Versions 0402 or Earlier: The instructions for setting a PIN Code are provided in
1 minute of ON time and 8 hours of OFF time. the Advanced Programming section of this manual. See
page 23.
Later FIRMWARE Versions:
5 minutes of ON time and 1 hour of OFF time.

The unit should be powered up in OFF mode. If the unit


powers up in ON mode and has not been primed, hold
the reset button located on the control panel (example
shown on the right) for 1 second to move to the OFF
mode.

20 332317P
Plus Model Control Setup

To enter the PIN Code: 1. To set the ON Time use the


UP or DOWN ARROW button
1. Press both the UP and to scroll through numerals 0
DOWN ARROW buttons for 3 to 3 until the desired number
seconds. appears in the first MM (min-
utes) field.

2. The LED next to the LOCK ICON on 2. Press the ENTER button. The next MM
the display lights and the 4 zeros number field to the right flashes indicat-
appear on the display indicating the ing it is ready for programming.
system requires a PIN Code entry to access the G1
in SETUP MODE. 3. Use the UP or DOWN
ARROW button to scroll
3. The cursor is automatically through numerals 0 to 9 until
positioned to enter the first the desired number appears
character of the PIN Code. in the second MM number
Use the UP and DOWN field.
ARROW buttons to move up
and down through the numbers 0-9 until the first 4. After pressing the ENTER button to set
number in the PIN code is displayed in the field. the last MM field, all the programmed
ON Time information is saved.
4. Press the ENTER button to set the
number. The cursor automatically The G1 automatically switches to the OFF Time
moves to the next number field. SETUP MODE.

5. Repeat steps 3 and 4 for each PIN Code prompt


OFF Time
field.
• OFF Time is set in Hours (HH).
If the PIN Code you entered is correct, the first editable
character on the display will flash. • In SETUP MODE the number dis- OFF
played in the first field, on the left
NOTE: A blinking field on the display indicates the G1 is side of display blinks, indicating the
in SETUP MODE. In RUN MODE numbers on the dis- device is ready to program the OFF
play will not blink. Time hours.

• Total amount of OFF time cannot HH


ON Time exceed 24 hours.
• ON Time is set in Minutes (MM). Programming OFF Time
• In SETUP MODE, the number dis- NOTE: When programming a time of less than 10
hours you must program a leading zero in the first
ON
played in the first field, on the left
side of display blinks, indicating the number field and press the ENTER button to save the
device is ready to program the ON zero selection.
Time minutes.
1. To set the OFF Time use the
• The total amount of ON Time can- UP or DOWN ARROW button
not exceed 30 minutes. MM
to scroll through numerals 0
to 9 until the desired number
Programming ON Time appears in the first HH (hour)
NOTE: When programming a time of less than 10 min- field.
utes you must program a leading zero in the first num-
ber field and press the ENTER button to save the zero 2. Press the ENTER button to lock in the
selection. selection. The next HH number field to
the right flashes indicating it is ready for
programming.

332317P 21
Plus Model Control Setup

3. Use the UP or DOWN


ARROW button to scroll
through numerals 0 to 2 until
the desired number appears
in the second HH number
field.

4. After pressing the ENTER button to set


the last HH field, the OFF Time infor-
mation is saved.

22 332317P
Advanced Programming

Advanced Programming
Advanced
Setting Format/ Description Why Use This?
Option
Lockout
Secures setup modes with
A1 Code Prevents unauthorized users to adjusting settings.
PIN
(Optional)

Firmware 4.01 and later - Low Level with Controller Units

A10 Low Level Reset Changes low level fault upon This function changes the behavior of the low
Upon Power ON power ON. level fault upon power ON.

Default = OFF

Entering a PIN Code for the First Time 6. Repeat steps 4 and 5 for each PIN Code prompt
field.
Setting Up PIN Code
7. Press the ENTER button to save the
A PIN Code can be programmed into the G1 to protect PIN Code and exit Advanced Setup.
the settings from inadvertently being changed by unau-
thorized users.
Entering Advanced Setup
1. Press the UP ARROW button for 10
seconds. Press the UP ARROW button for 10 sec-
onds.

The LED next to the LOCK ICON on the If the G1 was previously set up to require a
display lights, indicating you have entered PIN Code, the LED next to the LOCK ICON
the PIN Mode. lights, indicating a PIN Code is required.

2. The word OFF appears in the 1. The cursor is automatically


display. Press the UP or positioned to enter the first
DOWN ARROW button to character of the PIN Code.
change this to ON. Use the UP and DOWN
ARROW buttons to move up
3. Press the ENTER button to enter the and down through the numbers 0-9 until the first
PIN Code. number in the PIN code is displayed in the field.

2. Press the ENTER button to set the


4. The cursor automatically is number. The cursor automatically
positioned to entered the first moves to the next number field.
character of the PIN Code.
Use the UP and DOWN 3. Repeat steps 1 and 2 for each PIN Code prompt
ARROW buttons to move up field.
and down through the numbers 0-9 until the first
number in the PIN code is displayed in the field. If the PIN Code you entered is correct, the G1 will be in
the Advanced Setup option used to change the PIN
5. Press the ENTER button to set the Code.
number. The cursor automatically
moves to the next number field. A1 - Changing PIN Code
To change a PIN Code, follow instructions for Entering
a PIN Code for the first time.

332317P 23
Advanced Programming

Models with Firmware 4.01 and 2. Press the UP or DOWN ARROW button to change
OFF to ON on the display to change the low level
Later reset upon power on.

3. Press the ENTER button.


A10 - Low Level Reset Upon Power On.
This function changes the behavior of the low level
upon pump power on. When A10 is on, a low level fault
clears when the pump power is cycled. The pump will
revolve 5 revolutions, checking to see if the low level
condition is still present. If not, it will self clear and con-
tinue. If a low level condition exists during the 5 revolu-
tions, it will go into a low level fault.

Low Level ON LED illuminates (FIG. 15).

ON OFF

MM HH

Lubrication Pump

FIG. 15

1. The default OFF is displayed. The


alarm output will toggle once a
second.

24 332317P
Run Mode

Run Mode Low Level


Pumps equipped with low level detection will stop
when the fluid level is sufficiently low to trigger the low
Time Control level fault.

After setup is complete, the G1 automatically begins to • The LED next to the LOW LEVEL
run the OFF Time sequence. ICON on the display flashes.

• The G1 runs the Add lubricant to the pump. See Loading Grease
programmed OFF ON OFF instructions, page 17 or Filling Oil Unit, page 18.
sequence.
• After lubricant is added, press the
(Notice the dot RESET button to clear the fault.
below OFF flashes
on the display MM HH
while the OFF Time NOTE: For higher viscosity fluids it may be
counts down. This necessary to clear the low level fault prior to
count down is in hours.) filling the pump. You can then press the
Manual Start button to start the pump
• When the OFF during the fill.
Time count ON OFF
reaches zero, the
Manual Run Cycle
G1 Automatic
Lubrication Pump To run an extra (non-programmed) lubrica-
turns the pump on tion cycle, push the Manual Start button.
and it runs for the MM HH
programmed ON NOTE: An Illuminated Remote Run Button
Time cycle. Kit: 571030, 571031 for starting a manual run cycle
remotely if used in conjunction with a 5-wire CPC
(Notice the dot below ON flashes on the display.) cable, is available from Graco. Contact your local Graco
distributor or Graco Customer Service for additional
• When the ON Time count reaches zero, the pump information about these kits.
shuts off again and the system again runs OFF
Time cycle and the OFF Time LED flashes again.

This sequence repeats itself until the device is


reprogrammed or a Low Level Fault occurs.

• If power to the pump is lost during a lubrication


cycle, when power is restored the pump will
resume the cycle with the same amount of time
remaining in the cycle as when the power was lost.

332317P 25
Troubleshooting

Troubleshooting

Problem Cause Solution


Unit does not power on Incorrect/loose wiring Refer to Installation instructions, page 7.
Tripped external fuse due to internal
Contact Graco Customer Service.
component failure

Unit does not power on (DC models Replace lubricant with pumpable lubri-
only) Tripped external fuse due to pumping cant, rated for environmental conditions
non-cold weather lubricant in cold and application.
weather -13°F (-25°C)
Replace fuse.
Tripped internal power supply fuse due
Unit does not power on (AC models only) Contact Graco Customer Service.
to power supply failure
Allowable ON time: 1-30 minutes Adhere to allowable duty cycle. Contact
Can’t set desired ON/OFF times Allowable OFF time: 1-24 hours Graco Customer Support if other duty
(in full minute or hour increments) cycles are required for application.
Verify the unit was programmed as
Unit is not operating based on the time Time entered was misinterpreted as MM
intended, referencing programming
that was programmed instead of HH (or visa versa)
instructions.
Reservoir retaining tabs are cracked or
Replace reservoir.
broken

Lubricant leaks past seal located on the Ensure vent hole is not plugged.
bottom of the reservoir Reservoir is being pressurized during fill-
If problem persists, contact Graco Cus-
ing tomer Service or your local Graco dis-
tributor for assistance.
Unit not pumping during ON cycle, but
Failed motor Replace unit.
controller lights and functions
Add grease following Loading Grease
Air is trapped in the reservoir between
Follower plate is not going down instructions, page 17. Ensure air is
the follower plate and lubricant
purged.
Increase pump on time.
Pump takes several minutes before it Pumping non-cold weather lubricant in
begins pumping cold weather -13°F (-25°C) Use grease suitable for temperature and
conditions.
Tripped internal, resettable fuse due to Verify manual run inputs have not cre-
Dim display, unit is not operating internal component failure or short cir- ated a short circuit condition. Cycle
cuit condition power.
Unit indicates a cycle or pressure alarm
Refer to programming ON Time, page
before the lubrication cycle could com- The ON Time was not entered correctly
21.
plete

26 332317P
Troubleshooting

Additional Fault/Warning Scenarios for Firmware Versions 0402

Alarm Type What it Looks Like What it Indicates Solution


Low Power If there is a voltage drop at Check voltage and avail-
Warning the power source during able current output at the
HH MM SS ##
! operation, the pump will go power source of the
into a low power warning pump.
condition.
ON OFF
The unit will continue to
MM : SS HH : MM operate for a total of 15
minutes before going into
C a Low Power Fault.
P1

Also if the pump power


C C
P2 123
C
P3
P cycles on power up for a
minimum of 3 times, the
pump will display a low
power warning.

If the warning condition


clears itself, the warning is
cleared and the unit con-
tinues operation.
Low Power There is a low voltage con- Check voltage and avail-
Fault dition at the power source. able current output at the
ON OFF power source of the
pump.

Press and hold the


RESET button to clear
fault.
MM HH

Lubrication Pump

332317P 27
Maintenance

Maintenance
Frequency Component Required Maintenance
Keep all fittings clean using a clean
dry cloth. Dirt and/or debris can
Daily and at refill Zerk Fittings
damage pump and/or lubrication
system.
Keep pump unit and reservoir clean
Daily G1 Pump Unit and Reservoir
using a clean dry cloth.
Keep display clean using a clean dry
Daily Display
cloth.
Monthly External Wiring Harness Verify external harnesses are secure.

28 332317P
Parts: 2 Liter Models

Parts: 2 Liter Models


Oil Reservoir

43

40b
44 42

Low Level Grease Models Only


45

35

41
Follower Plate Models Only

23
57 271

40a

60

15 16

13

14
67 12
3 37
1

31
66

17 3
Low Level Oil Models Only
33

1 Torque to 4 in. lbs (0.45 N.m)

2 Torque to 30 in. lbs (3.4 N.m)


34
3 Torque to 50 in. lbs (5.6 N.m)
3 4 2
30

332317P 29
Parts: 4 and 8 Liter Models

Parts: 4 and 8 Liter Models


Oil Reservoir

43
41
40b
44

Low Level Grease Models Only


41
45

42
Follower Plate Models Only 35

23
57 271
40a

61 60

16

56

62
67

13
14
12
66 3 37
1

Low Level Oil Models Only 31


17 3
33
1 Torque to 4 in. lbs (0.45 N.m)

2 Torque to 30 in. lbs (3.4 N.m)

3 Torque to 50 in. lbs (5.6 N.m) 34


30 3 4 2

30 332317P
Parts

Parts
FN Part No. Description Qty. FN Part No. Description Qty.
1 BASE, molded 1 SEAL, follower plate, 2 liter grease
278139 1
3 278142 BOTTOM, cover 1 models
4 115477 SCREW, bottom cover 9 SEAL, follower plate, 4 liter grease
41 16F472 2
RECT-RING, included in Kit 571069, models
12 127079 1 SEAL, follower plate, 8 liter grease
571179, 571042 16V763 2
O-RING, included in Kit 571042, models
13 132524 1
571044, 571045, 571069, 571179 42 PLATE, follower, grease models 1
14 PLATE, ricer 1
43 ROD, follower plate, grease models 1
15 BEARING, ball 1
SPRING, compression, grease mod-
PADDLE, stirring, 2 liter models with- 44 1
els
out follower plate, included in Kit 1
571044 24D838 BAFFLE, low level, 2 liter models 1
PADDLE, stirring, 4 and 8 liter mod-
45† 24E246 BAFFLE, low level, 4 liter models 1
els without follower plate, included in 1
16
Kit 571046
24F836 BAFFLE, low level, 8 liter models 1
PADDLE, stirring, 2 liter models with
1
follower plate, included in Kit 571045 56 127144 SEAL, oval 1
PADDLE, stirring, 4 liter models with
1
follower plate, included in Kit 571047 57 117156 BEARING, sleeve 1
17 ELEMENT, pump 1
58 196548 LABEL, shock warning 1
23‡ 278942 PADDLE, low level models 1
60 16D984 WASHER, low level models 2
27 123025 SCREW, M6 1 RESERVOIR, mid-section, 8 liter
61 1
models
24Z798 or
30‡✺ BOARD, circuit 1 ADAPTER, reservoir 4 and 8 liter
25U993 62 1
models
31 119228 SCREW, machine, flat head 2
66 126417 NUT 1
33 16A579 LABEL, safety 1
67 24N806 FLOAT, oil models 1
34 16T912 LABEL, overlay 1
Replacement Danger and Warning labels, tags and cards are
WIPER, stirring, models without fol-
available at no cost.
lower plate, included in Kit 571044, 1
571046 ‡✺Also order Ref 31 and Ref 34.
35
WIPER, stirring, models with follower
plate, included in Kit 571045, 1 † Also order Ref. 57 when ordering this part.
571047
FITTING, zerk, grease models (not
37 123741 1
included on oil models)
RESERVOIR, 2 liter, grease, included
40a 1
in Kit 571042, 571069
RESERVOIR, 2 liter, oil, included in
40b 1
Kit 571179
RESERVOIR, 4 liter, grease, included
40a 1
in Kit 571183
RESERVOIR, 4 liter, oil, included in
40b 1
Kit 571182
40a RESERVOIR, 8 liter grease 1
RESERVOIR, 8 liter, oil, included in
40b 1
Kit 571182

332317P 31
Parts

Pressure Relief Valves Fuses


Important Information regarding Pressure Relief
Valve 16C807. Part Description Qty

571039 FUSE, 12 volt DC 1


Pressure Relief Valve 16C807 can only be used on
the G1 and G3 Pumps. It is not intended for use with 571040 FUSE, 24 volt DC 1
any other products.

The pressure relief valve uses a a


pressure adjustment screw (a) to
b Installation and Repair Kits
set the pressure release point. It
Manual
is not intended as a way to
Kit No. Description Number
relieve pressure during normal
operation, but as a protective KIT, return to reservoir NPT, includes
571028
measure in the event there is an pressure relief valve 16C807
3A0525
unintended pressure increase in KIT, return to reservoir BSPP, includes
571071
the system. Do not use this pres- pressure relief valve 16C807
sure relief valve a means of 571030 KIT, remote manual run, 12 volt DC
3A0528
relieving pressure in day-to-day,
ti15644 571031 KIT, remote manual run, 24 Volt DC
normal cycle operation. 571036 KIT, cover with “G” label NA
a = adjustment KIT, pump element, includes Ref 17,
screw 571041 3A0533
The pressure adjustment screw 18, 33
will require periodic adjustments. KIT, repair, 2 liter reservoir, includes
571042
Whenever the valve is set/adjusted (after the set point is Ref 12, 13, 36, 40
found) it is important to ensure that the valve is not bot- KIT, repair, 2 liter reservoir, for models 3A0534
tomed out and there is at least 1/2 turn of adjustment 571069 with follower plate, includes Ref 12, 13,
remaining. This is determined by turning the screw (a) 36, 40
1/2 turn and then back turning it out again. KIT, replacement, paddle, 2 liter, for
571044 models without follower plate, includes
NOTE: Turning adjustment screw (a) clockwise Ref 13, 16, 35, 57
increases pressure. KIT, replacement, paddle, 2 liter, for
571045 models with follower plate, includes
Ref 13, 16, 35,40a, 42, 57
Part Description Qty 3A0535
KIT, replacement, paddle, 4-8 liter, for
VALVE, pressure relief, 500-3500 psi (3.44 571046 models without follower plate, includes
MPa, 34.4 bar - 24.1 MPa, 241 bar), Set Ref 13, 16, 35, 57
16C807 1
pressure 3000 psi + 10% (20.68 MPa, KIT, replacement, paddle, 4 liter, for
206.8 bar + 10%) Included in Kit 571028 571047 models with follower plate, includes
VALVE, pressure relief, 750 psi (5.17 MPa, Ref 13, 16, 35, 57
563156 1
51.71 bar) 571058 KIT, output adapter, NPT
VALVE, pressure relief, 1000 psi (6.89 3A0522
563157 1 571070 KIT, output, adapter, BSPP
MPa, 68.95 bar) 571060 KIT, fill, zerk, leakproof NA
VALVE, pressure relief, 1500 psi (10.34 KIT, repair, reservoir oil, 2 liter models,
563158 1 571179
MPa, 103.42 bar) includes Ref 12, 13, 36, 40b
VALVE, pressure relief, 2000 psi (13.78 KIT, repair, reservoir, oil 4 liter models,
563159 1 571182
MPa, 137.89 bar) includes Ref 12, 13, 36, 40b, 56, 62 3A0534
VALVE, pressure relief, 2500 psi (17.23 KIT, repair, reservoir, grease, 4 liter
563160 1
MPa, 172.36 bar) 571183 models, includes Ref 12, 13, 36, 40b,
VALVE, pressure relief, 3000 psi (20.68 56,62
563161 1
MPa, 206.84 bar)
127685 Fixing Ring for CPC connector NA
VALVE, pressure relief, 5500 psi (37.92
563190 1
MPa, 379.21 bar)

32 332317P
Technical Specifications

Technical Specifications
G1™ Plus Lubrication Pump
US Metric
Maximum Working Pressure 5100 psi 35.1 MPa, 351.6 bar
Power
100 - 240 VAC 88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz, Single phase,
inrush/locked rotor, max 40 A (1ms)
12 VDC 9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A
24 VDC 18 - 30 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A
Pumps 1

Pump Output 0.25 in.3 (4 cm3) / minute


Pump Outlet 1/4-18 NPSF, Mates with 1/4-18 NPT male fittings
Reservoir Size 2, 4, 8 Liters
IP Rating IP69K
Ambient Temps -40°F - 158°F -40°C - 70°C
Noise (dBa)
Sound Data <60 dB
Materials of Construction
Wetted Parts nylon 6/6 (PA), amorphous polyamide, T5004-060, zinc plated steel, carbon
steel, alloy steel, stainless steel, nitrile rubber (buna-N), bronze, nickel plated
alnico, chemically lubricated acetal, aluminum, PTFE
All trademarks or registered trademarks are the property of their respective owners.

Pump Maximum Weight lb (kg)


Model With follower plate Without follower plate
2L 12.4 (5.6) 11.4 (5.2)
4L 15.3 (6.9) 13.1 (5.9)
8L 16.8 (7.6) 14.6 (6.6)

Dimensions
Height Width Depth
Model
Inches cm Inches cm Inches cm
2L 13.25 33.65 8.00 20.32 9.00 22.86
4L 14.50 36.83 9.25 23.50 10.00 25.40
8L 18.50 47.00 9.25 23.50 10.00 25.40

California Proposition 65

WARNING: This product can expose you to chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information, go to
www.P65warnings.ca.gov.

332317P 33
Technical Specifications

Mounting Pattern
For correct mounting configuration, choose either Option 1 or Option 2. See Part Number 126916 template.

Option 1
0.367inch 7.087 inch
9.3 mm 180.0 mm

2x Ø 0.366 inch
9.3 mm 1.180 inch
30.0 mm

3.268 inch
83.0 mm

3.544 inch
90.0 mm

Option 2
0.722 inch 6.378 inch
18.3 mm 162.0 mm

2x Ø 0.366 inch
0.708 inch
9.3 mm
18.0 mm

3.740 inch
95.0 mm

3.189 inch
81.0 mm

FIG. 16

34 332317P
Notes

Notes

332317P 35
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification
of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be
returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or
workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental
or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder,
or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered
into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu
que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés,
à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.

Original instructions. This manual contains English. MM 332317

Graco Headquarters: Minneapolis


International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revision P, June 2022

You might also like